Version 4.

1 © 2002
GaLa Reinforcement ® www.alashki.com
PROFESSIONAL

Job Title PAREDES DAS BAIAIS - SECCAO A

General Loads: N, Mx
Design code: Eurocode 2 N<0 is compression !
Analysis: Failure surface

Section Data [cm]


d2 As 2
b =100
h =40
h
As2
As1 As 1
d1 =4 d1
d2 =4
b

Results Mx - N c hart
3000

2000
L1
1000
L2 L3
0

-1000
-2000
N [kN]

-3000
-4000

-5000

-6000

-7000

-8000
-700

-600

-500

-400

-300

-200

-100

100

200

300

400

500

600

700

M x [k Nm ]

Materials
Concrete: C25/30 Reinforcing steel: S500
SSR: Parabolic - linear SSR: Standard

fck = 25.00 MPa fyk = 500.00 MPa


Ec = 30471.58 MPa Es = 200000.00 MPa
ec2u = -3.500 o/oo esu = 10.000 o/oo
ec2 = -2.000 o/oo
n = 2.00

05/11/2014 page 1
Version 4.1 © 2002
GaLa Reinforcement ® www.alashki.com
PROFESSIONAL

Factors
Concrete: gama_c = 1.50
Steel: gama_s = 1.15

Reinforcement
Unsymmetic:

As1 =31.42cm2 As2 =31.42cm2

Solve data

II order moments: No

Section properties
Reinforcement :

As,tot = 62.84 cm2

Concrete section:

Ac = 4000.00 cm2
Ic,x = 533333.33 cm4

R/C section:

Ared = 4349.61 cm2


Ired,x = 622833.48 cm4
rx = 11.97 cm

05/11/2014 page 2