Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Q-Box

Body Plethysmography

When one breath


does matter

Accuracy and simplicity for the new benchmark


in Body Plethysmography
The new generation of body-box cabin for lung volume measurement
and airway resistance with the Gold Standard method of Body Plethysmography

█ All-in-one solution for Lung Volumes,


DLCO, Spirometry, Airways
Resistance, and Respiratory Mechanics
█ DLCO module for single-breath, intra-
breath and membrane lung diffusion
capacity
█ Forced Oscillation Technique module
for respiratory system assessment at
tidal breathing
█ Large cabin provides comfort while
keeping high measurements accuracy
█ Perform tests (except TGV and sRaw)
either inside or outside the cabin
█ Powered by OMNIA, the easy-to-use
software with superior networking
capabilities

The Q-Box is the standalone body-box from


COSMED for Gold Standard measurement
Body Plethysmography (TGV/RAW) Spirometry
of Static Lung Volumes (TLC, RV, TGV) and Body plethysmography tests can be quickly The Q-Box standard configuration includes
Airway Resistance and Conductance (RAW, and easily performed in a single manoeuvre all accessories for spirometry testing (FVC,
GAW) through the body plethysmography and the test sequence (TGV, sRAW, SVC, IC) SVC, MMV, Pre/Post and Broncho Challenge).
technique. can be defined according to user preferences. ■ Choice of different flowmeter configura-
■ Large constant-volume cabin. tions (pneumotach or turbine).
Spirometry is standard in the Q-Box, together
with the Respiratory Mechanics module, ■ Quick calibration and fast stabilization ■ Innovative pediatric incentivation with
and both can be performed either inside times. user-defined effort grade on both
or outside the cabin. The optional DLCO ■ Adaptable arm with quick-release volume and flow.
module allows also to perform lung diffusing mechanism for one-hand adjustment ■ System and operator Quality Control
capacity tests by using fast-response CO-CH4 and auto-locking. assessment.
gas sensors. The optional Forced Oscillation ■ Door opens 180° with safety knobs. ■ GOLD COPD interpretation for FVC
Technique offers a method for non-invasive PostBD.
assessment of respiratory mechanics in unco- ■ Simulate TGV occlusion with open door
to comfortably coach your patients on ■ Compliance with ATS/ERS standards.
operative patients.
testing manoeuvres. ■ Broncho Challenge protocol editor to
Q-Box unique and high quality components,
■ Ultimate pressure sensor transducers create user-defined protocols.
highly accurate pneumotach and super-
ensure maximum sensitivity with severe ■ Latest Global Lung Initiative (GLI)
fast analyzers guarantee accurate results
patient’s response. predicteds (including Z-score).
and make the Q-Box stand out from the
competition. ■ Possibility to capture multiple sRaw with
one single click.
The large cabin volume and the two handles
allow comfortable and easy access for both ■ Real-time review on all performed TGV
adults and special populations. and sRaw captures.
The glass and aluminum structure provides ■ Control bar for real-time quality control
large transparent surfaces, reliable hermetic assessment.
seal. ■ Integrated, transparent Compensation
The modular design allows easy maintenance Box for external pressure changes inter-
and parts replacement on the field without ference removal.
the need of specialized technicians.
Arm with quick release mechanism for one-hand
adjustment.
Respiratory Mechanics ■ Ideal for uncooperative patients such as
children or elderly people.
Available as standard testing feature, the
respiratory mechanics module includes: ■ Recognized reference method for pre- Door opens
■ Maximal Inspiratory Pressure (MIP) and
school children assessment. 180°
Maximal Expiratory Pressure (MEP).
■ Respiratory Drive assessment (P0.1),
including measurement with enriched OMNIA Software
O2 or CO2 inspiratory mixture. Q-Box is powered by OMNIA, the software
■ Intuitive display of all maneuvers with platform developed by COSMED to help clini-
editing features. cians provide the highest standard of patient
care. Wheelchair patients can be easily tested outside the
■ Graphical representation of main
cabin.
parameters, including pictograms. OMNIA features enhanced networking capa-
■ System and operator Quality Control bilities and is compatible with the entire
assessment. COSMED product range, from spirometry to ■ SQL based database ensures data safety
■ Automatic interpretation of test results. lung function equipment and from meta- and protection.
bolic to body composition assessment.
■ Compliance with ATS/ERS guidelines. ■ Share database and user settings over
■ Seamless workflow minimizes time to a local or geographically separated
testing and human errors. network with the possibility to define
■ Innovative and easy-to-use user inter- specific users’ roles and rights.
Lung Diffusing Capacity (DLCO) face with native touch-screen design. ■ Integrate data and testing workflow
The DLCO module allows the measurement ■ Guidance tools and quality control with the Hospital Information System
of diffusing capacity of Carbon Monoxide feedback. (HIS).
(CO) in the lungs with different test options:
single-breath, intrabreath and membrane
diffusion.
■ Continuous analysis of CO and CH4
(tracer) with fast NDIR analyzer.
■ CO analyzer designed specifically for
DLCO and thus independent from
exhaled CO2.
■ Pneumatic line with minimal inspiratory
resistance for high patient comfort.
■ Test simulation (no gas delivered) to
coach subjects before testing.
■ Mouth pressure signal during DLCO
testing for real time quality control.
■ Advanced DLCO edit feature (automatic
and custom selection of washout and
alveolar gas volume).
■ Breath-hold time settings according to
various standards (Jones, Ogilvie, ESP).
Real time Body Plethysmography testing.
■ “0 wet” correction to compensate CO
backpressure and humidity interference.
■ Estimated TLC during DLCO, corrected
for obstructed patients.
■ Membrane Diffusion automatically
enabled when performing multiple
DLCOsb or DLCOib manoeuvres.
■ System and operator Quality Control
assessment.

Forced Oscillation Technique


The Forced Oscillation Technique module is a
system for the measurement of the mechan-
ical properties of the respiratory system
under tidal breathing conditions.
■ Total Respiratory Impedance measure-
ment by Pseudo Random Noise Signal.
■ Quick and easy assessment during
normal breathing. TGV capture edit.
All trademarks, registered trademarks and logos are the property of their respective owners.
Headquarters
ITALY
COSMED Srl
Rome
+39 06 931-5492
info@cosmed.com

GERMANY FRANCE THE NETHERLANDS DENMARK


COSMED Deutschland GmbH COSMED France SASU COSMED Benelux BV COSMED Nordic ApS
Werneck Brignais Nieuwegein Odense
+49 (0)9735 81390 00 +33 (0)4 478628053 +31 (0) 88 10 50 500 +45 6595 9100
DE@cosmed.com FR@cosmed.com BNL@cosmed.com DK@cosmed.com

SWITZERLAND USA AUSTRALIA HONG KONG


COSMED Switzerland GmbH COSMED USA, Inc. COSMED Asia-Pacific Pty Ltd COSMED HK Ltd
Fehraltorf Concord, Chicago Artarmon Kowloon
+41 (0)43 50 869 83 +1 800 4263763 Toll Free +61 449 971 170 +852 3708 3126
CH@cosmed.com USA@cosmed.com ANZ@cosmed.com HK@cosmed.com © 2024/03-a COSMED E & OE. Subject to alterations without prior notice. REF C09068-02-93

COSMED Q-Box is a medical device.

Distributed by

COSMED Srl To know more


Via dei Piani di Monte Savello 37
Albano Laziale - Rome 00041
Italy
+39 (06) 931-5492 Phone
+39 (06) 931-4580 Fax
cosmed.com

You might also like