in Body Plethysmography The new generation of body-box cabin for lung volume measurement and airway resistance with the Gold Standard method of Body Plethysmography
█ All-in-one solution for Lung Volumes,
DLCO, Spirometry, Airways Resistance, and Respiratory Mechanics █ DLCO module for single-breath, intra- breath and membrane lung diffusion capacity █ Forced Oscillation Technique module for respiratory system assessment at tidal breathing █ Large cabin provides comfort while keeping high measurements accuracy █ Perform tests (except TGV and sRaw) either inside or outside the cabin █ Powered by OMNIA, the easy-to-use software with superior networking capabilities
The Q-Box is the standalone body-box from
COSMED for Gold Standard measurement Body Plethysmography (TGV/RAW) Spirometry of Static Lung Volumes (TLC, RV, TGV) and Body plethysmography tests can be quickly The Q-Box standard configuration includes Airway Resistance and Conductance (RAW, and easily performed in a single manoeuvre all accessories for spirometry testing (FVC, GAW) through the body plethysmography and the test sequence (TGV, sRAW, SVC, IC) SVC, MMV, Pre/Post and Broncho Challenge). technique. can be defined according to user preferences. ■ Choice of different flowmeter configura- ■ Large constant-volume cabin. tions (pneumotach or turbine). Spirometry is standard in the Q-Box, together with the Respiratory Mechanics module, ■ Quick calibration and fast stabilization ■ Innovative pediatric incentivation with and both can be performed either inside times. user-defined effort grade on both or outside the cabin. The optional DLCO ■ Adaptable arm with quick-release volume and flow. module allows also to perform lung diffusing mechanism for one-hand adjustment ■ System and operator Quality Control capacity tests by using fast-response CO-CH4 and auto-locking. assessment. gas sensors. The optional Forced Oscillation ■ Door opens 180° with safety knobs. ■ GOLD COPD interpretation for FVC Technique offers a method for non-invasive PostBD. assessment of respiratory mechanics in unco- ■ Simulate TGV occlusion with open door to comfortably coach your patients on ■ Compliance with ATS/ERS standards. operative patients. testing manoeuvres. ■ Broncho Challenge protocol editor to Q-Box unique and high quality components, ■ Ultimate pressure sensor transducers create user-defined protocols. highly accurate pneumotach and super- ensure maximum sensitivity with severe ■ Latest Global Lung Initiative (GLI) fast analyzers guarantee accurate results patient’s response. predicteds (including Z-score). and make the Q-Box stand out from the competition. ■ Possibility to capture multiple sRaw with one single click. The large cabin volume and the two handles allow comfortable and easy access for both ■ Real-time review on all performed TGV adults and special populations. and sRaw captures. The glass and aluminum structure provides ■ Control bar for real-time quality control large transparent surfaces, reliable hermetic assessment. seal. ■ Integrated, transparent Compensation The modular design allows easy maintenance Box for external pressure changes inter- and parts replacement on the field without ference removal. the need of specialized technicians. Arm with quick release mechanism for one-hand adjustment. Respiratory Mechanics ■ Ideal for uncooperative patients such as children or elderly people. Available as standard testing feature, the respiratory mechanics module includes: ■ Recognized reference method for pre- Door opens ■ Maximal Inspiratory Pressure (MIP) and school children assessment. 180° Maximal Expiratory Pressure (MEP). ■ Respiratory Drive assessment (P0.1), including measurement with enriched OMNIA Software O2 or CO2 inspiratory mixture. Q-Box is powered by OMNIA, the software ■ Intuitive display of all maneuvers with platform developed by COSMED to help clini- editing features. cians provide the highest standard of patient care. Wheelchair patients can be easily tested outside the ■ Graphical representation of main cabin. parameters, including pictograms. OMNIA features enhanced networking capa- ■ System and operator Quality Control bilities and is compatible with the entire assessment. COSMED product range, from spirometry to ■ SQL based database ensures data safety ■ Automatic interpretation of test results. lung function equipment and from meta- and protection. bolic to body composition assessment. ■ Compliance with ATS/ERS guidelines. ■ Share database and user settings over ■ Seamless workflow minimizes time to a local or geographically separated testing and human errors. network with the possibility to define ■ Innovative and easy-to-use user inter- specific users’ roles and rights. Lung Diffusing Capacity (DLCO) face with native touch-screen design. ■ Integrate data and testing workflow The DLCO module allows the measurement ■ Guidance tools and quality control with the Hospital Information System of diffusing capacity of Carbon Monoxide feedback. (HIS). (CO) in the lungs with different test options: single-breath, intrabreath and membrane diffusion. ■ Continuous analysis of CO and CH4 (tracer) with fast NDIR analyzer. ■ CO analyzer designed specifically for DLCO and thus independent from exhaled CO2. ■ Pneumatic line with minimal inspiratory resistance for high patient comfort. ■ Test simulation (no gas delivered) to coach subjects before testing. ■ Mouth pressure signal during DLCO testing for real time quality control. ■ Advanced DLCO edit feature (automatic and custom selection of washout and alveolar gas volume). ■ Breath-hold time settings according to various standards (Jones, Ogilvie, ESP). Real time Body Plethysmography testing. ■ “0 wet” correction to compensate CO backpressure and humidity interference. ■ Estimated TLC during DLCO, corrected for obstructed patients. ■ Membrane Diffusion automatically enabled when performing multiple DLCOsb or DLCOib manoeuvres. ■ System and operator Quality Control assessment.
Forced Oscillation Technique
The Forced Oscillation Technique module is a system for the measurement of the mechan- ical properties of the respiratory system under tidal breathing conditions. ■ Total Respiratory Impedance measure- ment by Pseudo Random Noise Signal. ■ Quick and easy assessment during normal breathing. TGV capture edit. All trademarks, registered trademarks and logos are the property of their respective owners. Headquarters ITALY COSMED Srl Rome +39 06 931-5492 info@cosmed.com