MGC Moser-Glaser Ltd.

POWER CHINA, SEPCO 1


Lerchenweg 21 Shandong China
4303 Kaiseraugst
SWITZERLAND
Phone: +41 61 467 61 11

Date: 31.05.2024 Your Inquiry Date: 01.04.2024


Our reference: Peter Schreiner Your Reference: Mr. Muhammad Aftab Tahir
Our Phone: +41 61 467 61 61 Your Phone: +92 30 52497077
Our E-Mail: peter.schreiner@mgc.ch Your E-Mail: aftab@abduls-group.com
Agent: 7AAYS Corporation Your Customer No.: 4473

Quotation No.: OA 2024 1068301 Page: 1 of 7

Pakistan / WB-10A-2021 (500KV Nokhar Grid Substation)


Many thanks for your interest in MGC products.
As a result of your valued inquiry we are very pleased to provide the following proposal:
Quotation No.: OA 2024 1068301 Page: 2 of 7

Technical description DURESCA®

The DURESCA® busbar are fully insulated compact busbar system, type RIP (resin impregnated paper).
The insulation lays directly on the conductor and consists of wrapped paper dried under vacuum and
impregnated with epoxy resin. Conductive grading layers are embedded during the wrapping in the
insulation for the best field control. The earth layer of 50 mm2 which can take up an internal short circuit
current of 8 kA/ 1 sec. is entirely embedded in the insulation and provides a complete electrical screen.
This guarantees the highest operational and human safety.

The DURESCA® busbar system is calculated on an ambient temperature of 40°C. The temperature rise
of the conductor at rated current can be up to 50 K.

On the whole length of the bar, the surface of the insulation is covered by a corrugated protection tube in
polyamid, aluminium or stainless steel. This protection tube provides an effective barrier against moisture
ingress.

DURESCA® Busbar Main Features:


solid, separately isolated phase bus, fully earthed for human safety.
the earth layer of 50 mm2 which can take up an internal short circuit current of 8 kA/ 1 sec.
safe service conditions, even in high ambient humidity.
partial discharges free operation.
compact dimensions, tight bend radius.
suitable for complete outdoor installation.
high short-circuit capability.
custom engineered for each individual installation.
operating temperature down to -40 degrees C (upon request -50 degrees C).
factory tested.
easy installation.
maintenance free.

Note:
When installing and commissioning the DURESCA® busbar system, it is essential to ensure that the
busbar system including brackets is earthed in accordance with the specifications in our dimension
drawing and connected to a single earth potential.
Different earth potentials can lead to damage to persons and plant components.

Due to a high current circulating in main conductor, a magnetic field occurs around the system. The use
of magnetic materials like steel in the narrow of busbars should be submitted to agreement between
customer and MGC.
Quotation No.: OA 2024 1068301 Page: 3 of 7

Included in the busbar system are:

1. Calculation, engineering of the busbar ways according to the customer building drawings.
2. Layout drawings of the busbar system
3. Detailed drawings of the connection to the switchgears, transformers etc.
4. Detailed drawings of the support material
5. Partlists
6. Technical datasheets
7. Manuals in English
All documents are available in pdf format.

Standarddocumentation:
1 Set in paper
1 set PDF via Email
Multiple documentation is possible and will be charged.

Included in the scope of delivery are the standard fastening material and earth clamps. The included
standard fastening material is calculated for a busbar - wall or ceiling distance of max. 1.50m. Larger
distances or special fastening supports etc. will be charges upon needed items.

Included in the scope of delivery is the complete earthing material (copper wire cross section 50mm2).

Remark:
While mounting or taking the DURESCA® busbars into operation it is a must to connect the complete
busbar system as well as the support material according to our drawings and recommendations on one
single earth potential.
Different earth potentials may cause risks for human beings as well as for the complete system.
Quotation No.: OA 2024 1068301 Page: 4 of 7

Pos. Part No. / Drawing no. Quantity Unit Price Total Price
Description EUR EUR
10 DE52/4000/AL 1.0 set 159'000.00
214'600.00 159'000.00
214'600.00
DURESCA Busbar

Tertiary connection

One set of outdoor condenser busbars,


type DE, with DURESCA®-insulation, Um = 52 kV as per IEC.
With conductor in aluminum, for a maximum current of 4000 A.

Bill of material see scope sheet OA 2024 10683.

20 MGC Supervision 1.0 Pcs


20 MGC-FAT 1 pcs 3'750.00 3'750.00
Supervision is included in above prices.
FAT-Tests
Performed at MGC factory, CH-Kaiseraugst, according to the IEC 60137, clause 9.2, 9.4 and 9.5.
Based on our technical Specification.
Without Factory training (The training of the client's workers is part of the Position "Supervision"):
1 day in our factory.
0.5 day for preparation.
Each additional day will be charged according to the daily rate.
Included for up to 2 persons from the customer.

Note: The Travel Tickets, Hotel, daily expenses... for the client's inspector(s) are excluded.

FAT Test are carried out on pre-selected items up to max. 10% of the to be delivered parts.

40 MGC-SPECIALS 1 pcs 15'000.00 15'000.00


MGC-SPECIALS
Estimated cost for L/C

Invoiced at actual cost


Quotation No.: OA 2024 1068301 Page: 6 of 7

Pos. Part No. / Drawing no. Quantity Unit Price Total Price
Description EUR EUR
- The assembly date must be confirmed by the customer at the latest 6 weeks before the start
of assembly.
- In the event of postponements < 4 weeks, we reserve the right to claim costs for
cancellations, rebookings and for the loss of personnel.

local taxes are not included!


Price basis: excl. value added tax
The quoted price is based on a pure estimate, as details of the location, accessibility, storage location
of the material, etc. were not available at the time of the offer.

fix price X invoiced at actual cost

Total Amount (EUR) 214'600.00

Routine tests:
Routine test according to IEC 60137, 2017-06 performed on each individual sleeve (Um > 12kV) and
busbar.

Clause 9.2 Measurement of dielectric dissipation factor (tan delta) and capacitance
Clause 9.4 Dry power-frequency voltage withstand test
Clause 9.5 Measurement of partial discharge quantity
Highest partial discharge values at 1.50 Um/V3: <= 10 pC

Increase/ decrease in price:


Our prices are based on the information are available to us, upon preparation of our proposal and as per
the terms contained herein. Deviations leading to additional effort or supplies due to inconsistencies
between design and actual dimensions will be changed on a cost plus basis. Prices can also decrease if
parts which are included in this quotation are not needed.
Bill of material according to scope sheet of this quotation.

Commercial Terms
Terms of delivery:
FCA, free carrier 4303 Kaiseraugst, according to Incoterms 2020

Method of shipment:
by seafreight
Quotation No.: OA 2024 1068301 Page: 7 of 7

Terms of payment:
100
50%%atthrough
Order conf. and irrevoc. L/C
The
50%contract comes into force when the accepted (by client and MGC) letter of credit is available.
before Delivery
All dates guaranteed under the condition that the payments are on time.
The manufacturing will only be started after the receipt of the payment.
When the payments take place at a later time the date of delivery has to be mutually agreed upon.

Delivery time:
30 weeks (ex works) after approval of drawings.
The confirmed delivery date can only be guaranteed if the drawings are approved by the customer on
time.

Warranty:
24 months after taking into operation, but latest 30 months after information ready for shipment.
The warranty only refers to contractual deliveries by MGC, any further liability is excluded. The liability of
the Company to the Purchaser shall not in any case exceed the cost of the defective part. Seller shall not
be liable for damage due to act of ordinary negligence nor for consequential damages or damages for
economic losses, or claims against Buyer resulting from third-party.

Validity of quotation:
1 month

We thank you for this inquiry and submit you the required quotation.
We would be please to execute that project for you.
Do not hesitate to contact us for any further information’s.

Please always mention the delivery and billing address in your order.

This quotation is based upon the General Conditions of Sale published on www.mgc.ch. All other
conditions do not apply unless otherwise written agreed by MGC Moser - Glaser AG.

Our offer is based on daily updated raw material prices. Due to the current situation on the raw
materials market, we reserve the right to adjust our offer prices to the current prices. Should the
raw material prices change extraordinarily during the project execution phase, we reserve the
right to make a price adjustment.

Kind regards