Professional Documents
Culture Documents
Data Sheet LP2 Modular Probe System For Tool Setting and Workpiece Inspection
Data Sheet LP2 Modular Probe System For Tool Setting and Workpiece Inspection
2
Trigger force, which is critical in some applications, is the force exerted on the component by the stylus when the probe triggers. The maximum
force applied will occur after the trigger point (overtravel). The force value depends on related variables including measuring speed, machine
deceleration and latency.
3
These are the factory settings, manual adjustment of the LP2/LP2DD is possible, but not possible on LP2H/LP2HDD.
For further information and the best possible application and performance support, contact Renishaw or visit
www.renishaw.com/lp2
www.renishaw.com/lp2 #renishaw
LP2 dimensions
20 (0.79)
LP2/LP2H
7.5 (0.30)
7 (0.27)
12.5°
Ø25 (0.98)
M16 × 1
12.5°
M4 stylus 6.5 (0.26)
40.8 (1.61)
20 (0.79)
4.8 (0.19)
LP2DD/LP2HDD
7 (0.27)
15°
Ø25 (0.98)
M16 × 1
15°
M4 stylus
6.5 (0.26)
40.8 (1.61)
Dimensions in mm (in)
2 www.renishaw.com/lp2
LP2 modular system
Shank
Hard-wired transmission
FS3 probe
socket
Radio or FS2 probe FS1 probe
socket socket Shank adaptor
optical MA2 probe
receiver holder
LP2 M4 styli
LP2H
Stylus weak link
LPE extension bar
Transmission
LP2DD
modules
MA 4 adaptor
LP2HDD
Swarf
deflector
www.renishaw.com/lp2 #renishaw