PL-101 Specification

The PL-101 module offers additional isolation for the BOA2 camera and simplifies
wiring at the control panel. The PL-101 is connected to the camera through a single
M12 cordset.
The I/O and RS-232 connections of BOA2 are available through the Pl-101.
Specification for these signals are as follows:

Specification Definition

Voltage Load 24 V maximum


Current GPO[0-2] 200 mA max @ 20°C
Protection Fuse PTC fuses to 200 mA at 20°C or 150 mA at 70°C
Common ICMN/OCMN PWR or GND as wired on respective OPTOs
Switch Time GPO[0-2] 800 Microseconds (ON or OFF, includes camera switch time)

PL-101 Connections

I/O Status LEDs


Control Panel
I/O connections

Strobe/Output0 O0/Strb 0
Output1 O1 1 I/O connection to
Output2 O2 2
OutCommon BOA Spot
OC

Trigger/Input0 I0/Trig 0
Input1 I1 1
Input2 I2 2
InCommon IC
9 pin DSUB for
GND serial connection
PWR
ERTH

Manual Trigger for


debugging

PL-101 Specification 1 Version 1.0; 2020-8-10


PL-101 Mechanical Dimensions

Note: All dimensions in mm

Top View

Side View