VALVE FUNCTIONALITY TEST REPORT

Po No. 23418 Product Name TRUNNION BALL VALVE Specification 3”300LB RF Body Material A350 LF2

ITEM No. 30 Contract Quantity 1 PC Test Quantity 1 PC Operator PNEUMATIC Service Temperature 15℃

Design Standard API 6D Acceptance standard API 6D

SERIAL NO. VALVE FUNCTIONALITY OPEN TIME(s) CLOSE TIME(s) LIMIT SWITCHES CONTACT PNEUMATIC CONNECTIONS REMARK

23418108 OPEN/CLOSE 5 3 OK No air leakage OK

falta colocar la PH con el actuador

Charles Anthony
Signature/Date Reviewed By/Date
2024.03.19 2024.03.19
Final Inspection Report

Po No. 23418 Item No. 30 Report No. FIR2409 -30

Valve Type TRUNNION BALL VALVE Spec. 3"300LB Quantity 1 PC

Serial No. 23418108 Inspection Result Accepted

Inspection Items Inspection Requirement Inspection Result Rating

Nameplate installation location is correct or not, the


Data Plate Accepted Accepted
contents are consistent with the physical.

There is no residual medium and impurities in the body


Cleanliness Accepted Accepted
cavity.

Both ends of the valve flange sealing surface protective


Protective cover Accepted Accepted
cover installed firmly.

Packing pressure into the stuffing box depth, should not


Cylinder number of exceed the effective height of the packing pressure of
Accepted Accepted
filler 1/3;and the same specifications of the valve should be
basically the same.

The gap between the inner hole of the gland and the shaft of
Space of gland hole Accepted Accepted
the valve stem should be uniform, no obvious difference.

The teeth number of stem all the same specifications to keep


Stem height Accepted Accepted
consistent.

Bolt Bolt with the number of teeth maintain uniform. Accepted Accepted

Cavity antirust cavity spray (coating) anti rust oil. Accepted Accepted

Mounting Brackets
falta la prueba de falla y explicar
Brackets dimension and postion is correct. Accepted
por Accepted

que no tiene redundancia en


Actuator solenoides
The actuator open andasi tambien
closed in 5 times. no se ve la
Accepted Accepted

apertura manual
Limit switch Clear Limit switch of open or closed. Accepted Accepted

Solenoid The solenoid work successfully. Accepted Accepted

Air Filter Regulator The air filter regulator work successfully. Accepted Accepted

Whether the external part of the valve is in accordance with


Surface Painting the requirement of paint, color, brightness, thickness, Accepted Accepted
strength is in line with the requirements.

Overall Rating Accepted Disposition Notes

Inspector/Date Charles / 2024.03.20 Auditor/Date Anthony / 2024.03.20