Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

8000 Dis

splay
y & Acqui
A sition
Pla
atform
m
Tech
hnical Detaills

813 Ra
ack mount
sor
Process
81
10 Signal processorr

Sys
stem des
scription
n
3 Remote Panel
803 P Disp
play
Sig
gnal proc
cessor

• Included in the 810,


8 816 an
nd 813 unitts

• Torqueetronic multipole torqquemeters generate twot sinusoidal signalss as


the shhaft rotatess. Their ph
hase differe
ence is directly propoortional to the
twist o
of the shaftt and hence
e applied to
orque.

• ation curren
Excita nt supplied to the tran
nsducer

• Zero crossings detected and sent to Master 32 bit processor for


urement.
measu

• d Master processor co
32bit high speed omputes toorque, spee
ed, power and
tempeerature and sends to 16bit
1 DAC a
and Slave processor
p

• Up to 10kHz update rate to DAC

• Slave processor handles co


ommunicattions via Etthernet, RS
S485 and U
USB
using Modbus pro
otocol.

• Shaft ttemperaturre compens


sation from
m transduce
er mounted RTD

• Stores
s multiple sets of transducer ca alibration data, switch
hed digitally
y or
by extternal datas
set select terminals

• Analogg outputs of Speed d, Torque,, Power and Shaftt temperatture


selecta
able as +/--10V or 4-2
20mA. Outp
puts isolated as standa
ard

• Digitall data available over 10mS


1 - 8Se
ec update rate
r or as blocks
b of u p to
1024 ssamples forr torsional analysis

• peed pulse outputs att signal tootth frequenc


Two sp cy

• m fault voltt free warning contactt


System
816 Fie
eld Mount
• Digitall Connectio
on to option
n modules
Processor

T
Torquemeters Limited
Ravensthorpee, Northampto
on, NN6 8ET, U
United Kingdo
om.
T
Telephone: +44 (0)1604 770232 Fax: ++44 (0)1604 770778
7
email: info@torquemeters.com www.torrquemeters.co
e om
PC Based Displays

• Included in the 803 and 813 units

• Single board PC

• Windows™ XP embedded

• 7” Touchscreen TFT display

• Installed TorqTo™ software for display, configuration and diagnostics

• Display of torsional analysis data using TorqTo™ software

• 813 with built in signal processor board

• 803 for remote connection via ethernet or RS485 to 810 or 816 signal processors

• Configurable as Modbus slave over RS485 or Ethernet

Certification

• CE marked
• EMC – meets EN61326:2-1 standard and FCC requirements
• 816 certified for use in Zone 2 / Div 2 hazardous locations
o ExnA [ia Ga] IIC T4 Gc -20≤Ta≤55◦C
o ATEX, IECEx and FM certified
• 810, 803 and 813 certified ordinary location use FM standards

PSL 09.05.140
REV A
INSTA
ALLATIO
ON DET
TAILS

810 SIG
GNAL PRO
OCESSOR
R

3
35mm DIN
N rail
m
mount

24V dc 1
15W

Ph
hoenix
ombicon Pllug
Co
onnectors
Co

81
13 RACK MOUNT
PR
ROCESSOOR
19” 3U high

24V
2 dc 30W
W

Phoeniix Combico
on
Plug Co
onnectors
s

PSL 0
09.05.140
REV A
INST
TALLAT
TION DE
ETAILS

803 REMOTE
E PANEL DISPLAY
Y
19” 3
3U high

24V
V dc 20W

Phoenix C
Combicon Plug
Connecto
ors

816 FIELD MO
OUNT PR
ROCESSO
OR

Suitable
e for Zone
2/Div 2 hazardou us
location
n installation
close to transduce er

Includees zener ba
arriers
for Exia
a transducer
connecttion

24V dc
c 15W

PSL 0
09.05.140
REV A

You might also like