Professional Documents
Culture Documents
Exactsteam V-Cone: Description Specifications
Exactsteam V-Cone: Description Specifications
MODEL
ExactSteam™ V-Cone® Europe
DESCRIPTION SPECIFICATIONS
The ExactSteam V-Cone System’s innovative design
Accuracy: ± 0.5% for primary element
delivers repeatable accuracy of +0.5% of rate with ±1% for total system
up to a 50:1 flow range under the most difficult flow
Repeatability: ±0.1% or better
conditions. The ExactSteam V-Cone System acts as its
Turn Down: Up to 50:1 with stacked configuration
own flow conditioner, fully conditioning and mixing
or 10:1 with compact
the flow prior to measurement. Readings are always
Installation Piping 0-3 diameters upstream, 0-1
precise and reliable, even under changing flow
Requirements: diameters downstream
situations.
Materials of Stainless Steel or Carbon Steel
Construction:
With this unique ability to self-condition flow, the
Line Sizes: 2” to 12” / 50 mm to 300 mm
ExactSteam V-Cone System virtually eliminates the
End Fittings: Beveled or DIN PN16 or DIN PN40
need for upstream or downstream straight pipe runs.
flanges
Thus, the ExactSteam V-Cone System can be installed
RTD: • Sensor Type: PT-100, thin film
virtually anywhere in a piping system or easily retrofit
• Range: -58° to 752° F (-50° to 400° C)
into an existing piping layout, resulting in significant
Manifold: Configuration: 3-Valve
installation flexibility and cost savings. In addition,
dP Transmitter: • Housing Material: F30 Aluminum
the ExactSteam V-Cone System has proven to provide
• Membrane Material: 316L
long-term performance with no moving parts to • Enclosure Rating: NEMA 4X/6P,
replace or maintain. IP66/67
• Electrical Connections: NPT1/2
thread
Flow Computer: • Output: 4-20 mA, Isolated Pulse
Contact vconerfq@mccrometer.com for other sizes or
KEY FEATURES configuration options.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA Printed In The U.S.A.
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078 Lit. # 30122-74 Rev. 1.1 / 4-25-17
Copyright © 2017 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published
www.mccrometer.com technical data and instructions are subject to change without notice. Contact your McCrometer representative for current technical data and
instructions. V-Cone is a registered Trademark of McCrometer, Inc.
SPECIFICATION SHEET
MODEL
ExactSteam™ V-Cone® Europe
FLOW
W L
Beveled: Overall length (A) tolerance varies with line size: ORDERING INFORMATION:
½” to 1”, ±0.01” (±0.3mm) 1. Select Nominal Pipe Size and include Maximum Flow Rate.
1½” to 4”, ±0.06” (±2mm) 2. Specify units of measurement for both the flow rate indicator and totalizer.
6” to 10”, ±0.12” (±4mm)
3. For vertical installation, specify upflow or downflow.
12”, ±0.19” (±6mm)
DIN Flanges: Overall length (L) tolerance varies with line size: Meter will be 10:1 flow range standard (i.e. 400 to 40 GPM)
½” to 1”, ±1/16” (±2mm) NOTE: Larger meter sizes, special laying lengths, other flow ranges available
1½” to 10”, ±1/8” (±4mm)
by special order.
12”, ±3/16” (±6mm)
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA Printed In The U.S.A.
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078 Lit. # 30122-74 Rev. 1.1 / 4-25-17
Copyright © 2017 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published
www.mccrometer.com technical data and instructions are subject to change without notice. Contact your McCrometer representative for current technical data and
instructions. V-Cone is a registered Trademark of McCrometer, Inc.
SPECIFICATION SHEET
MODEL
ExactSteam™ V-Cone® Europe
Primary Element
Electronics
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA Printed In The U.S.A.
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078 Lit. # 30122-74 Rev. 1.1 / 4-25-17
Copyright © 2017 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published
www.mccrometer.com technical data and instructions are subject to change without notice. Contact your McCrometer representative for current technical data and
instructions. V-Cone is a registered Trademark of McCrometer, Inc.