Professional Documents
Culture Documents
Qbit Command-V1.4
Qbit Command-V1.4
POSITION
7 Check position
ASETAPN, [X]#
2 Set automatic APN
2 Set automatic APN
ASETAPN#
ASETGMT,[X]#
3 Set automatic GMT
ASETGMT#
SERVER,mode,domainName/IP,
4 Set server parameters port,protocol#
SERVER#
GMT,[A],[b],[C]#
5 Set GMT parameter
GMT#
6 Restore to factory FACTORY#
EURL,network links#
7 Edit URL
EURL#
8 LANG,[A]#
set language
LANG#
GPRSON,X#
9 GPRS switch
GPRSON#
10 Reboot RESET#
SOS,A,[phone number 1][,phone
number 2][,phone number 3]#
SOS,D,[sequence number 1][,
11 SOS setting sequence number 2][,sequence
SOS,[D],[phone number]#
SOS#
HBT,[T2]#
12 Heartbeat interval setting
HBT#
13 Clear the backup data CLEAR#
BATALM, [A][, M]#
15 Set the low battery alarm
BATALM,OFF#
BATALM#
16 Boot remind BOOTALM, [A][, M]#
BOOTALM,OFF#
BATCH,[A][,N]#
17 Set the GPS data sending batch
BATCH#
SENDS,[A]#
19 Set the GPS controlled time by sensor
SENDS#
20 Clear the backup data CLEAR#
SF,[A][,B]#
21 Set the static data filtering
SF#
22 Set delay time of voice monitor DELAY,<A>#
23 Monitoring setting MONITOR#
GFENCE,[N],[B],0,[D],[E],[F],[X],[
M]#
GFENCE,[N],[B],1,[D],[E],[F],[G][,
X][,M]#
GFENCE#
BATALM, [A][, M]#
26 Set the low battery alarm
BATALM,OFF#
BATALM#
SOSALM,[A],[M]#
27 Set the SOS alarm
SOSALM,OFF#
SOSALM#
28 Call settings JC,<A>#
CALL,N#
29 Set the dialing times
CALL#
30 LS,<A>#
Set ring mode
LS#
31 Set sensitivity of SENSOR LEVEL,<A>#
PWDSW,[A]#
32 Set the instruction password
PWDSW,[password],[B]#
BOOTALM,<A>[,M]#
35 set boot alarm
BOOTALM,OFF#
BOOTALM#
MODE,N,T#
MODE#
39 Set WIFI
WF[,A][,T1][,T2]#
WF#
it COMMANDS LIST
Reply Explanation
[VERSION]:GT350_10_61A_LG10_
WM
[BRANCH]:11CW1352MP
GXQ61D_GPS_11C
IMEI:864799998888777;TIMER:10
,10;SENDS:3;SOS:,,;CENTER:;Senso
rset:10,3,5,1;TimeZone:E,8,0;
GPRS:ON;APN:cmnet,,;Server:1,gt
350.gpsluckly.com,8827,0;URL:htt
p://ditu.google.cn/maps?q=;
Charging.Battery:4.17v.GPRS:Link
Up;GSM Signal
Level:strong;GPS:Successful
Positioning,SVS used in fix:6.GPS
Signal
level:41,39,37,21,23,28.GPS_Mod
e:GPS_SAVE_MOD2;Defense:OFF;
Current position!
Lat:N22.57776,Lon:E113.91667,Co
urse:334,Speed:0Km/h,DateTime:
2015-12-28 09:15:12
e.g.<01-08
17:36>http://maps.google.com/m
aps?q=N22.577156,E113.916748
e.g.
GPS located: <01-08
17:36>http://maps.google.com/m
aps?q=N22.577156,E113.916748
A:E or W;"E" means eastern time zone, "W" means western time
zone;default:E
B:0~12;time zone default:8
C:0/15/30/45;half time zone;default:0
A=ON/OFF, default:ON;
M=0/1, way of alarming, 0: GPRS only, 1: SMS+GPRS, default:0;
Close the low battery alarm.
Check the parameters of the alarm.
A=ON/OFF,default: OFF
M=0~1, way of alarming, 0: GPRS only,1: SMS+GPRS, default:0
Close the boot remind
A= A=ON/OFF, data sending batch function on or off, default:OFF
N=1~50, N means the number of messages in the batch, default:
30;
Check the number of messages in a batch.
A=10-300 seconds,detecting time. Default: 10 seconds
B-10-300 seconds, alert delay. Deault:10 seconds
C=1-300 minutes, vibration alert interval. Default: 5 minutes
SENSOR# Check the parameter of the status
A=0-300(minute), time duration for GPS to work once vibration
detected, 0 means GPS always on work, default: 3(minute)
Check the parameters of the time.
circle area;
N=1-5;Fence sequnce number
B=ON/OFF, open or close fence alarm, default:close;
D=the latitude of the circle center;
E=the longitude of the circle center;
F=1~9999, the fence radius, unit:100 meters;
X=IN/OUT;IN: alarming when get in the fence, OUT: alarming when
get out the fence, blank means both alarming when get in or get out
the fence, default: blank.
M=0/1;way of alarming, 0:GPRS only, 1:SMS+GPRS, default:1
rectangle area
N=1-5;Fence sequnce number
B=ON/OFF, open or close fence alarm, default:close;
D=the latitude of the position 1;range:-90 ~90(degree);
E=the longitude of the position 1;range:-180 ~180(degree);
F=the latitude of the position 2;range:-90 ~90(degree);
G=the longitude of the position 2;range:-180 ~180(degree);
the latitude supports "N/S" or "+/- " coming before it's value;
the longitude supports "E/W" or "+/- " coming before it's value;;
Check the parameters of the fence.
A=ON/OFF, default:ON;
M=0/1, way of alarming, 0: GPRS only, 1: SMS+GPRS, default:1;
Close the low battery alarm.
Check the parameters of the alarm.
A=ON/OFF, default:ON;
M=0/1/2/3, way of alarming, 0 :GPRS only, 1: SMS+GPRS, 2 :
GPRS+SMS+phone call, 3: GPRS+phone call; default:3;
Close the SOS alarm.
Check the parameters of the alarm.
A=0-1, 0: two-way communication;1:monitor;default: 0
N=1~3, default:1, times to dial all numbers;
Check the parameters of the dialing.
A=0-2, 0: Flash + Sound ;1:flash;2:No flash and sound
;default:0
Check current statue
A=1-5: sensiticity range; default:2
LEVEL# check the current sensitivity of sensor
A= ON, enable the instruction password.
Numbers and letters mix inputs supported for instruction password, at
least 1 character, no more than 19 characters, default:666666;
B=OFF, disable the instruction password.
A=old password, numbers and letters mix inputs supported, at least
1 character, no more than 19 characters, default:666666;
B=new password, numbers and letters mix inputs supported, at least
1 character, no more than 19 characters.
A=phone number, phone number to send;
B=SMS content, content to forward.
Only SOS can use this command.
A=ON/OFF, default: OFF
M=0/1 default: 1
turn off boot alarm
Check current statue.
N=1/2, 1: WIFI timing and positioning mode 2: gps timing and
positioning mode , default: 1
N=1,T means wifi upload interval in fixed time(10~65535
seconds)
N=2,T means if vibration detected and the device is motional, the
GPS data will be uploaded in T; If device is motionless, the GPS will
sleep.
(5~18000 seconds) default: 180
T=5~300(minutes)
GPS works for 5 minutes.
A=ON/OFF,default: ON
T1=1~60(second); means scanning hot time after open wifi;
default:10
T2=10~65535(second); means Device automatically turns on WIFI
search every T seconds and uploads hotspot to platform。Default:
Check current statue.