Construction Manual

Sep. 17, 2009


社外秘
CONFIDENTIAL C C-7-C3450.51 英
Aug. 3, 2008
*5 Function of clock setting

Depending
MON0 on the value10
の値に応じて of MON0, it indicates data by decimal figure.
進データを表示
MON0=0~F

LED indicator *1
MON1 MON0 Function
7SEG3 7SEG2 7SEG1
0 Indication and setting of last 2 digits of RTC “year”. 0 Year
1 Indication and setting of RTC “month”. 1 Month
2 Indication and setting of RTC “date”. 2 Date
Day of the
3 Indication and setting of RTC “day of the week”. 3 -
week
4 Indication and setting of RTC “hour”. 4 Hour
5 Indication and setting of RTC “minute”. 5 Minute
6 - - - -

6 7 - - - -
8 - - - -
9 - - - -
A - - - -
B - - - -
C - - - -
D - - - -
E - - - -
F - - - -
“Note 1”: The indication data is indicated by decimal figure. The method of setting data is referred to item 7).
“Note 2”: The indication day of the week is 0:Sun. , 1:Mon. , 2:Tue. , 3:Wed. , 4:Thu. , 5:Fri. , 6:Sat.

Y.KARIYA
MITSUBISHI ELECTRIC CORPORATION 2014/01/14 - N
Construction Manual
社外秘
CONFIDENTIAL C C-7-C3450.52 英
Aug. 3, 2008
*6 Related function of the variable traveling speed elevator and installed completion flag setting

Refer to the table


下表参照。

LED indicator
MON1 MON0 Function
7SEG3 7SEG2 7SEG1
0 **1 Release of compulsory setting of speed
1 **1
Compulsory setting of the rated speed Run:Indication of the state of elevator
and the floor No.
2 **1 Compulsory setting of the rated speed at middle load 2 Stop:The peak holding value of speed
Compulsory setting of the rated speed at middle load 1
3 **1
(maximum speed)
Indication of BL weighing NL weighing
Clearness of load weighing device adjustment
4 **2 the state of device writing device writing
completion flag
elevator condition condition
Run:Indication of the state of elevator
5**1 Compulsory setting of the rated speed at middle load 3 and the floor No.
Stop:The peak holding value of speed
6 - - - -
8
7 - - - -
8**4 SETS-L inspection data confirmation Indication of the SETS-L inspection data *
9 - - - -
A - - - -
B - - - -
C - - - -
D - - - -
E - - - -
While installing:”oF”
F **3 Release of installing recognition flag A
After release:”on"
**1 It is effective only to apply the variable traveling speed elevator. After setting MON1/0, SW1 and SW2 are knocked down downward
at the same time (about 2 seconds). When the mode is fixed, 7 Seg indicator flickers.
**2 After setting MON1/0, SW1 is knocked down downward and SW2 is knocked down upward at the same time
(about 2 seconds). When 7SEG2 and 7SEG1 both indicates “F”, the setting is completed.
**3 After setting MON1/0, SW1 and SW2 are knocked down downward at the same time (about 2 seconds).
When it indicates ”oF”→”on" , the setting is completed.
**4 When SW2 are knocked down upward or downward after setting MON1/0, the indication data is changed to the other one. *

Y.KARIYA
MITSUBISHI ELECTRIC CORPORATION 2014/01/14 - N
Construction Manual
社外秘
CONFIDENTIAL C C-7-C3450.53 英
Aug. 3, 2008
*7. Data setting

Data
MON0 = 0 to F

LED indicator In case of


MON1 MON0 Function
7SEG3 7SEG2 7SEG1 *1 LHH-32XA

0 Setting for MG 0 - MG
1 Setting for DG 1 - DG
2 - - - -
3 Setting for BLSH 3 - BLSH
4 - - - -
5 Setting for LTB 5 - LTB
6 - - - -
7 - - - -
9 not applicable
8 - - - -
9 - - - -
A - - - -
B - - - -
C - - - -
D - - - -
E - - - -
F - - - -
“Note 1”: Set value of 7SEG1 is from 0 to F.
The method of setting data is referred to item 7).

Y.KARIYA
MITSUBISHI ELECTRIC CORPORATION 2014/01/14 - N
Feb. 20, 2012 Nov.29,2013 Construction Manual
Mar. 31,2011 Aug 30, 2013
社外秘
CONFIDENTIAL C C-7-C3450.54 英
Aug. 3, 2008 Dec. 10, 2012
*8 Indication for S/W version

Version code
“o” means order, “d” means date of assembly,
“r” means the name of ROM.

LED indicator *1 In case of


MON1 MON0 Function
7SEG3 7SEG2 7SEG1 LHH-32XA

0 Supervision-1 applicable

1 Supervision-2
2 Group Control o:order
Indicates the version code of
d:date
3 Control each S/W sequentially
r:ROM
4 Drive
5 Maintenance
6 - 0 0 0
7 Parameter
Supervision-Order o:order
Indicates the version code of
F (for NEXIEZ-MRL and d:date
8 each S/W sequentially
NOTE2
ELENESSA (S/W TYPE CODE r:ROM
“VFGLC2” and GQ4W2)) *
9 -
A - 0 0 0
B -
o:order
Indicates the version code of
C Converter d:date
each S/W sequentially
r:ROM
D -
E - 0 0 0
F -
“Note 1”: Refer to in the next page about the detail of data.
“Note 2”: Change of a display cycle only NEXIEZ-MRL. (12/12C production or later, Control S/W GLCC113-AF~) and *
ELENESSA(S/W TYPE CODE “VFGLC2” (13/8C production or later, Control S/W GLCC113-AI ~ ) and
ELENESSA(GQ4W2 (14/2C production or later, Control S/W GLCC113-AL~))
Before change : Each display time is “2.4sec disply” and “1.2sec non-display” (~GLCC113-AE)
After change : Each display time is “4.7sec disply” and “0.1sec non-display” (GLCC113-AF~)
(Each display is displayed 2 times respectively at Hall position indicator and LHH-32XX )

Y.KARIYA
MITSUBISHI ELECTRIC CORPORATION 2014/01/14 - N
Construction Manual
Feb. 20, 2012
社外秘
CONFIDENTIAL C C-7-C3450.55 英
Aug. 3, 2008
*About S/W VERSION INDICATION DATA
Each software has the information below on the ROM and is capable of indicating this hexadecimal code by 7 segment in order.
Inazawa Works order (ASCII code 8 byte)…EAG45901 → 45H,41H,47H,34H,35H,39H,30H,31H
Assemble date (BCD code 4 byte)…1997-08-28 → 19H,97H,08H,28H
Standard ROM name(ASCII code 8 byte)…CCG01S-A → 43H,43H,47H,30H,31H,53H,2DH,41H
*The order and the date are set only when the construction manipulation is conducted. For the standard ROM, FFH is used.

[Indication example]
1) With order
o45→o41→o47→o34→o35→o39→o30→o31 …Indicates the order of Inazawa Works

d19→d97→d08→d28 …Indicates the date of assembly

r43→r43→r47→r30→r31→r53→r2d→r41 …Indicates the ROM name

(Repeat from indication of order of Inazawa Works)

2) Without order
r43→r43→r47→r30→r31→r53→r2d→r41 …Indicates the ROM name

(Repeat from indicates the ROM name)

*The indication order is refreshed every 2 seconds and it is no indication at the moment when it is refreshed. If there is no ROM
information, the condition of no indication is held.

*9 Display function of Supervision


When MON SW is set as MON1=C/D/E, it displays about Supervisory S/W.

Y.KARIYA
MITSUBISHI ELECTRIC CORPORATION 2014/01/14 - N
Construction Manual
社外秘
CONFIDENTIAL C C-7-C3450.56 英
Aug. 3, 2008
7) Setting method of numerical data
The method of increment the selected 7SEG with toggle switch SW2△.
(Toggle switches SW2▽ is used for setting indication value.)
MON1··········· selects to request mode
MON0··········· selects to request mode
7SEG3·········· Indicates the selected mode
7SEG2·········· Blank
7SEG1·········· Indicates the indication by toggle switch SW2 below.
SW2△ ········· Increases the 7SEG1 indicator (… 0→1→2→ … →E→F→0→ …)
SW2▽ ········· enters the displayed value 7SEG1, to revise RAM setting.

8)Function of the check pins

PCB Jumper Function

IU Checks the phase-U of motor DC-CT feedback signal.

P1-Card IV Checks the phase-V of motor DC-CT feedback signal.

VCHR Checks the reset circuit output signal

Y.KARIYA
MITSUBISHI ELECTRIC CORPORATION 2014/01/14 - N
Feb. 20, 2012 Construction Manual
Oct. 11, 2011
社外秘
CONFIDENTIAL C C-7-C3450.57 英
Aug. 3, 2008
9) Function of HIP (Hall Inspection Panel)

Hall indication box

Label Confirmation window for the governor rope


There may be no confirmation window
only NEXIEZ-MRL. In HAND operation by HIP, the
display to the Hall position indicator is changed to the
Car move direction and Car speed. (refer to 1-9)

Indication PCB (LHH-32XA)


7SEG
SW3
MON0 SW2
MON1 SET0
SW1
5(UP) SET1
29(SPD)
LED 41DG(DN)
DZ EMERGENCY STOP
420
MAIN SWITCH
(Main power supply ON/OFF) RUN
DOOR
ED SW UP Buttons for hand operation
(Short circuit the safety circuit. and emergency electrical operation.
According to EN81-1.14.2.1.4) (Use ED SW; according to EN81-1.14.2.1.4)
AUTO/HAND DN
RSQ
(Switch for release the brake) BKD
(Button for release the brake)
LIGHT(EMR/HIP)

Light in HIP

LIGHT SWITCH WELL LIGHT

Connectors for test box.


(HTA,HTB)

Y.KARIYA
MITSUBISHI ELECTRIC CORPORATION 2014/01/14 - N
Construction Manual
Feb. 20, 2012
社外秘
CONFIDENTIAL C C-7-C3450.58 英
Aug. 3, 2008
10) Function of HMC (Hall Manual Controller)

Hall manual controller box


Label

Indication PCB (LHH-32XA)


7SEG
SW3
MON0 SW2
MON1 SET0
SW1
5 SET1
29
LED 41DG EMERGENCY STOP
DZ
420

RUN
DOOR
UP Buttons for hand operation
and emergency electrical operation.
(Use ED SW; according to EN81-1.14.2.1.4)
DN
AUTO/HAND

WELL LIGHT

Y.KARIYA
MITSUBISHI ELECTRIC CORPORATION 2014/01/14 - N