Professional Documents
Culture Documents
Vapour & Liquid Flow Rates: Note 1
Vapour & Liquid Flow Rates: Note 1
Vapour & Liquid Flow Rates: Note 1
Separator Sizing
Vertical Horizontal
Allowable Vap Velocity m/s = 0.5 Allow Vapour Velocity m/s = 0.7
Vapour Flow Area m² = 0.0 Vapour Flow Area m² = 0.0
Min Dia m = 0.0
Vessel Diameter, D m = 0.0 2.1 Selected Dia m = 12.0
Vessel X Area m² = 0.00 3.46 0.3
Liquid LAHH D m 12.0 12.3 12.6 12.9 13.2
For Liquid Hold up m = ##### 0.0 L m 0.0 0.0 0.0 0.0 0.0
For Level Gaps m = 0.6 0.6 L/D 0.0 0.0 0.0 0.0 0.0
Vapour Space m = 1.5 1.5
Suggested Height, L m = ##### 2.0 Try # 1 Smaller Dia x Longer Drum
L/D = ##### 1.0 Assume Liquid X Secn %= 17% Note 1
Vessel Diameter, D m = 12.00
Vessel X Secn m² = 113.1
Liquid X Secn m² = 19.5
Min LAHH m
= 1.8
α= 0.80
Calculated Liquid X Secn % = 0.09
Ratio: assumed/ calculated = 0.5
This quick-Sing calculation ignores liquid level Note 1: Goal seek on W24 to make W32 as 1
settings. Do, a proper detailed analysis after Length - Liquid Holdup m = 0.0
checking the likely size Suggested Length, L m = 0.0
L/D = 0.0