408-3327
Index Strip
Figure 4
Rev F 2 of 3
408-3327
Figure 5
2.3. Workmanship Guidelines (To Help Ensure 1. Cross-connect wires are terminated in the top of
Performance of Installation) the connecting block using Impact Tool 569994-1 or
KRONE* universal wire insertion tool.
1. Strip only enough cable jacket to allow See Figure 6. Use low impact setting.
termination of pairs.
CAUTION Do NOT use 788J1 five pair impact tool to
2. Place tension on twisted pairs when bending and terminate cross-connect wires in connecting
routing in order to maintain twist and close blocks.
conductor spacing. !
3. Maintain pair twist up to point of termination in
2. The wires should be completely inserted to the
index strip. Allow no more than 13 mm [0.5 in.] to
bottom of the wire slot and the excess wire should
untwist.
be removed by the cutting edge of the impact tool.
3. TERMINATING CROSS-CONNECT WIRES 4. REVISION SUMMARY
NOTE
Only 22 through 26 AWG insulated wire should be Since the previous version of this document, the
terminated to the connecting block. (Maximum following changes were made:
diameter over insulation is 1.3 mm [.050 in.].)
i • Corrected third party trademark reference.
• Updated document to corporate requirements.
• Rebranded to CommScope
Impact Tool
569994-1
Cutoff Blade
Connecting Block
Figure 6