AC Ba r Ion

DC Ionizer with Integral Power Supply Explosion Proof Ionizer



H
D

-
C
DC Voltage Ionizer EXPLOSION PROOF IONIZER A
C
ELIMINOSTAT DC-ESR-C 8804 System (Manufacture: YDK Technologies Co., Ltd.) 型

i zer/D C ion i zer


Static Elimination
Electrode JT8853
Adaptor Specification (Option)
Two electordes : AD-02
Six electrodes : AD-06
Connection Joint JT8880

Ion Alarm LED JT8880-T


Power Device JT8823
Main Features AC Adaptor (Option)
JT8880-L JT8880-4
The DC-ESR-C is a corona discharge bar type ionizer. As the
compact-size DC power supply builts in the bar electrode, it
requires only a low-voltage cables and low-voltage wiring for
safety features.
● Good ion balance by DC corona discharge JT8880-P
(manual ion balance feature is also available) Main Features
● Less dust produced by Tungsten emitter needle.
● Multiple electrodes can be connected to the connector on two This is a static elimination system with a special exlosion-proof
ends of the bar. (it is possible to connect 2 electrodes, upto 6 structure(s1G4). The design of this system emphasizes on providing
electrodes by changing adaptor.) maximum safety level, such as by using non-flammable V0 as the
insulation material of the electrode.
● Certified by explosion proof structure inspection (certified as # T55243 etc)
● Connection cable is made of pressure-proof and explosion-proof
Downward Flow Velocity 0.3m/sec structure.
1000
400mm
● Effective electrode length is 120 to 2925 mm (pitch: 15mm). One
600mm
800mm
power supply can use up to 5 static elimination electrodes.
750 1000mm
● High-voltage cables can be connected up to 50 m in length, and various
charging voltage(V)

cable connectors (round branch, small branch, L-shaped connector,


500 plug) can be used in various installation environments.
● The integrated electrode tube blower type eliminates more static
250
electricity area than ion blower type.
0 *This anti-explosive regulation is only approved in Japanese Goverment. In case its
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 6 7 8 10 12 14 ▲Connector installation, need to submit "Customer(User) name", "User address", "User
Decay Time(sec) installation purpose and location", "The kind of solvent or gas for application", and
Principle of DC Voltage +7KV "Sales channel".
Static Elimination
DC Voltage -7KV
Dimension Diagram
■ Electrode JT8853
L+36 Accessories
200
φ4.5
R1/8 53
78
47

85
32 10
Fixing Hole Ground terminal Discharge Electrode
45 40 15
Dimension 10
L(120~2925)
(Needle)
20 77
Diagram Ion Balance Adjust dial
Electrode Length (15mm pitch)
16
Emitter needle cover Main Unit 0.3m ~ 92 28
- Output Indicator
20 + Output Indicator
10 32 ■ High Voltage Cable JT8891 50m
50

Expl
4


1 9

P100×n 200 P100×n 16 (unit: mm)


L-40 H
- osi on proof Ionize r

Emitter needle
L-20 Power Supply/
Electrode JT-8853 A
D
Output Terminal Electrode Length 120~2925mm(15mm interval)
L
Number of Electrodes 1 ~ 5 unit/1 power supply device
C
C
Standard size: 600/1000/1400mm, Maximum size: 2000mm AC Adaptor
Ion Blower Pipe Available for with or without 型
Number of emitter needles
L= 600/800mm 4 needles HV output: (+) x 2, (-) x 2
Power Supply Input Terminal
Air Pressure 50 ~ 200kPa ﹈
L= 1000/1200mm 8 needles HV output: (+) x 4, (-) x 4 Accessories Electrode length above 1155mm is standard spec
L= 1400/1600mm 12 needles HV output: (+) x 12, (-) x 12 1800±50
(unit: mm) Power unit JT-8823
Power Voltage Only AC100V 50/60Hz
Model DC-ESR-C Current Consumption Maximum 2.7A
Input Power DC24V(Option AC Adaptor AC100~240V Available) Secondary Voltage AC6600V 50/60Hz
Current Consumption 0.1A Heavy/Light Fault Output Each 1C Contact Output AC125V 0.4A
High Voltage DC High Voltage Power Suply Paint Color 2.5Y9/1(standard)
Output Voltage Minimum DC4kV MaximumDC7kV Weight around 14kg
Dimensions(D×H×L) 32×50×600/800/1000/1200/1400/1600/1800mm HV Cable JT-8891
Weight 0.37kg(L=600) Structure Silicon rubber insulated, Chloroprene sheath coaxial cable
Ion Balance Ion Balance Adjust Feature Total Cable Length 4~50m per 1 Power Unit
Decay time 2.1sec*1
Ozone Level Ozone Below 0.05ppm*2 System Model 8804(includes static elimination electrode, power unit and cable)
Emitter Needle Material Tungsten(option: single-crystal silicon) Explosion-Proof Special Explosion-Proof Structure (s1G4)
Environment Temperture: 10 ~ 40°C, Humidity: 5 ~ 70%RH(No Condensation) Specifications Cable Installation Location: Non-Dangerous(Flamable) Spot
Connection Features AC Adaptor AD-02(Optional): upto 2 cables, Other Device Spot: Dngerous Spot(under explosion-proof environment)
AC Adaptor AD-06(Optional): upto 6 cables. Certification Number: Based on Electrode Length T55243, T55561~T55566
Total length of all cables must be less than 12m. (Different combinations of certification number are not allowed)
Optional AC Adaptor(AD-02, AD-06), Power Cable: PWC-DC(2m) Efficient Current Over 0.4μA/cm (charged voltage -5kV, installation distance 2cm)
Connectinn Cable EC-DC500(0.5m), EC-DC1500(1.5m), EC-DC2500(2.5m) Environment Temperture: -10°C ~ +40°C, Humidity: Under 80%RH(No Condensation)
*1: CPM Tester (corresponding to ESD STM3.1-2000) ion balanced condition, Static elimination from + 1000V to +
100V decay time、reference distance 300mm.
*2 Distance from the main unit air outlet at 150mm to measure ozone density