CATEGORY IV VISUAL & MAGNETIC PARTICLE INSPECTION REPORT 2022-12-6002

ON RIG REG#: XA 6517, POLE MAST.


CLIENT: PI CONSULTANTS LTD
ADDRESS: #159 ORANGE GROVE ROAD, TACARIGUA.

INSPECTION DATE: 2022 NOVEMBER 26TH


EXPIRY DATE: 2027 NOVEMBER 25TH

COMPONENTS: POLE MAST


LOCATION: A & V OIL, PENAL
INSPECTION STANDARDS; ASME SEC, V. ART. 7 & 25 AND ASTM E709, AWS D1.1 & API RP 08 B
DIAGNOSTIC AREA: 100% WELD AND HAZ
TEST METHOD: WET(SPRAY)/ VISUAL
MANUFACTURING PROCESS: WELDED
MATERIAL: CARBON STEEL

EQUIPMENT USED
1.MAGNET TYPE: CANDET PERMANENT MAGNET SERIAL# 95110

2. CHEMICALS: 1.) MAGNAFLUX WHITE CONSTRAST PAINT WCP 2


2.) MAGNAFLUX PREPARED BATH 7HF (SUSPENDED IN PARAFFIN)

TECHNIQUE
INITIAL DEMAGNETIZATION: N/A FINAL DEMAGNETIZATION: N/A
CONTACT SPACING: 4-6” APPLICATION: SPRAY
TEST TEMPERATURE: AMBIENT TIME: 10 SECONDS
CURRENT: N/A SURFACED: BUFFED CLEANED

COMPONENTS: REMARKS: STATUS:


POLE MAST NO RELAVANT DEFECTS FOUND ACCEPTABLE

This certificate is to certify that on 2022 NOVEMBER 26TH a thorough inspection was carried out and the above is a true representation of our
findings.

1|Page
DESCRIPTION PHOTOGRAPH PASS/FAIL
POLE MAST No discontinuities were found.