S710Dv19 10
S710Dv19 10
aft
This data sheet is set-up to be used in electronic format by both the purchaser/user and the supplier/manufacturer.
This data sheet provides reference back to the parent standard or the supplementary specification where relevant.
Dr
Default values (if applicable) are pre-populated in this data sheet, but may be modified as required by the user.
The Supplement sheet is provided in an open format sheet for application of specific items not covered in the main part
of the data sheet. This sheet is not intended to modify requirements defined in the supplementary requirements
specification.
iew
The data sheet includes a revision (issue) column on the right hand side for use by the purchaser/user. After the first
issue, for each subsequent revision of the data sheet that is issued to suppliers for enquiry or purchase, the
purchaser/user should use the issue column to denote that the data on a specific row has been updated since the
previous revision. This will enable the supplier to easily identify where changes have been made.
Legend Select Supplier/manufacturer completed, pick list of pre-defined values (may be pre-populated
with a default value).
ev
Input data Supplier/manufacturer completed data entry.
Select Purchaser/user completed, pick list of pre-defined values (may be pre-populated with a
default value).
cR
IOGP S-710Dv19-10
SPECIFICATION October
S-710D 2019
aft
Dr
w
v ie
Re
ic
bl
Pu
Revision history
Acknowledgements
aft
This IOGP Specification was prepared by a Joint Industry Project 33
Standardization of Equipment Specifications for Procurement organized
by IOGP with support by the World Economic Forum (WEF).
Dr
w
v ie
Re
Disclaimer
Whilst every effort has been made to ensure the accuracy of the information
contained in this publication, neither IOGP nor any of its Members past present or
ic
future warrants its accuracy or will, regardless of its or their negligence, assume
liability for any foreseeable or unforeseeable use made thereof, which liability is
hereby excluded. Consequently, such use is at the recipient’s own risk on the basis
bl
that any use by the recipient constitutes agreement to the terms of this disclaimer.
The recipient is obliged to inform any subsequent recipient of such terms.
This publication is made available for information purposes and solely for the private
Pu
use of the user. IOGP will not directly or indirectly endorse, approve or accredit the
content of any course, event or otherwise where this publication will be reproduced.
Copyright notice
The contents of these pages are © International Association of Oil & Gas Producers.
Permission is given to reproduce this report in whole or in part provided (i)
that the copyright of IOGP and (ii) the sources are acknowledged. All other rights are
reserved. Any other use requires the prior written permission of IOGP.
These Terms and Conditions shall be governed by and construed in accordance
with the laws of England and Wales. Disputes arising here from shall be exclusively
subject to the jurisdiction of the courts of England and Wales.
IOGP S-710Dv19-10
S-710D Data Sheet for
Air-cooled Heat Exchangers
Foreword
This specification was prepared under Joint Industry Programme 33 (JIP33) “Standardization of Equipment Specifications for
Procurement” organized by the International Oil & Gas Producers Association (IOGP) with the support from the World Economic
Forum (WEF). Companies from the IOGP membership participated in developing this specification to leverage and improve
industry level standardization for projects globally in the oil and gas sector. The work has developed a minimized set of
supplementary requirements for procurement, with life cycle cost in mind, resulting in a common and jointly approved
specification, building on recognized industry and/or international standards.
Recent trends in oil and gas projects have demonstrated substantial budget and schedule overruns. The Oil and Gas
aft
Community within the World Economic Forum (WEF) has implemented a Capital Project Complexity (CPC) initiative which
seeks to drive a structural reduction in upstream project costs with a focus on industry-wide, non-competitive collaboration and
standardization. The CPC vision is to standardize specifications for global procurement for equipment and packages, facilitating
improved standardization of major projects across the globe. JIP33 provides the oil and gas sector with the opportunity to move
from internally to externally focussed standardization initiatives and provide step change benefits in the sector’s capital projects
performance
Dr
This specification has been developed in consultation with a broad user and supplier base to realize benefits from
standardization and achieve significant project and schedule cost reductions.
w
The JIP33 work groups performed their activities in accordance with IOGP’s Competition Law Guidelines (November 2014).
v ie
Re
ic
bl
Pu
IOGP S-710Dv19-10
S-710D Data Sheet for
Air-cooled Heat Exchangers
Introduction
The purpose of this equipment data sheet is to define purchaser specific requirements for the supply of air-cooled heat
exchangers in accordance with API Standard 661, Petroleum, Petrochemical, and Natural Gas Industries - Air-cooled Heat
Exchangers, Seventh Edition, July 2013 - Reaffirmed, June 2018. for application in the petroleum and natural gas industries.
The data sheet provides project specific requirements where the supplementary specification and its parent standard require the
purchaser to define an application specific requirement. It also includes information required by the purchaser for technical
evaluation purposes.
aft
This data sheet shall be used in conjunction with the supplementary requirements specification (IOGP S-710), information
requirements specification (IOGP S-710L) and quality requirements specification (IOGP S-710Q) which together comprise the
full set of specification documents. The Introduction section in the supplementary requirements specification provides further
information on the purpose of each of these documents and the order of precedence for their use.
Dr
w
v ie
Re
Data Sheet
bl
Pu
IOGP S-710Dv19-10
S-710D Data Sheet for
Issue
Row
aft
10 Conformity assessment system (CAS) level : D
11 Thermal and hydraulic design scope : Select
12 Case : Input Data
13 Heat exchanged : Input Data Select
14 Type draught : Select
15 Bay size width : Input Data Select
16 Bay size length : Input Data Select
17 Number of bays per item : Input Data
18 Surface area - finned tubes : Input Data Select
19 Surface area - bare tubes : Input Data Select
Dr
20 Mean temperature difference (MTD.) - effective : Input Data Select
21 Transfer rate-finned (service) : Input Data Select
22 Transfer rate-Bare tube (service) : Input Data Select
23 Transfer rate- bare tube (clean) : Input Data Select
24 9.1.1.1 Purchaser documents : Input Data Select
25 Basic design data
26 Pressure design code : Input Data
27 Applicable local regulation : Input Data
28 Tube bundle code stamped : Select
29 Heating coil code stamped : Select
30 7.3.1.1 Structural code : Input Data
31
32
33
34
iew
Flammable service :
Lethal service :
Toxic service :
Cyclic service :
Select
Select
Select
Select
35 4.6 Sour service : Select
36 Hydrogen service : Select
37 7.3.3.7 Wind load : Input Data
38 7.3.3.8 Earthquake load : Input Data
39 Blast load : Input Data
40 Motion load : Input Data
41 Snow load : Input Data
42 Performance data - tube side
43 Fluid name : Input Data
ev
44 Inside fouling resistance : Input Data Select
45 Total fluid entering : Input Data Select
46 Total flow rate (liquid) - IN : Input Data Select
47 Total flow rate (vapour.) - IN : Input Data Select
48 Total flow rate (liquid) - OUT : Input Data Select
49 Total flow rate (vapour.) - OUT : Input Data Select
50 Water- IN : Input Data Select
51 Water- OUT : Input Data Select
cR
Issue
Row
aftft
99 Design, materials and construction
100 Design pressure : Input Data Select
101 Test pressure : Input Data Select
102 10.2.1 Test pressure basis : Input Data
103 Maximum design temperature : Input Data Select
104 Minimum design metal temperature : Input Data Select
Dr ra
105 Steam out design temperature : Input Data Select
106 Steam out design pressure : Input Data
107 Personnel protection : Select
108 Shop run in test : Select
109 Hail screen : Select
110 Insect screen : Select
111 Lint screen : Select
D
112 Post weld heat treatment : Select
113 Tube-to-tubesheet joint type : Input Data
114 Tube-to-tubesheet joint – mock up : Select
115 Header purging method : Select
116 10.1.1, 10.1.2 RT and/or UT extent : Select
117 MT or PT extent : Input Data
118 Tube bundle
119 Size (width x length) : Input Data Select
120
121
122
123
124
125
ieww Number of bundles/bay :
Number of tube rows :
Bundles in parallel :
Bundles In series :
Structure mounting :
Pipe-rack beams (distance C-C) :
Input Data
Input Data
Input Data
Input Data
Select
Input Data
ev vie
126 Ladders, walkways, platforms : Select
127 Structure surface preparation /coating : Input Data
128 Header surface preparation /coating : Input Data
129 Tube
130 Material : Input Data
131 Tube type : Select
132 Outside diameter : Input Data Select
133 Minimum wall thickness : Input Data Select
134 Number of tube /bundle : Input Data
135 Length : Input Data Select
136 Pitch : Input Data Select
c RRe
Issue
Row
aft
Drraft
188 Pressure drop (allowable) : Input Data Select
189 Pressure drop (calculated) : Input Data Select
190 Design tempurature : Input Data Select
191 Design pressure : Input Data Select
192 Inlet nozzle size : Input Data Select
193 Outlet nozzle size : Input Data Select
194 Mechanical equipment
195 Maximum design exposure temperatures for mechanical components and instruments : Input Data Select
196 Fan
197 Manufacturer : Input Data
198 Number of fans /bay : Input Data
199 Speed : Input Data rpm
200 Diameter : Input Data Select
wD
201 Number of blades : Input Data
202 Angle : Input Data degree
203 Pitch adjustment : Select
204 Blade material : Input Data
205 Hub material : Input Data
206 Fan absorbed power at design temperature : Input Data Select
207 Fan absorbed power at minimum ambient temperature : Input Data Select
208 vieew Maximum allowable tip speed : Input Data Select
209 Calculated tip speed : Input Data Select
210 7.2.3.17 Fan ring inlet : Select
211 7.3.4.6 Plenum thickness : Input Data Select
212 Driver
213 Type : Input Data
214 Manufacturer : Input Data
215 Number of motors/bay : Input Data
216 Driver shaft orientation : Select
217 Driver rating : Input Data Select
218 Speed : Input Data rpm
219 Service factor : Input Data
Reevi
220 Enclosure : Input Data
221 Volt : Input Data
222 Phase : Input Data
223 Cycle : Input Data Hz
224 Fan noise level (allowable) : Input Data dB(A)
225 Fan noise level (calculated) : Input Data dB(A)
226 Extent of VSD : Input Data
227 Speed reducer
229 Manufacturer : Input Data
230 Model : Input Data
licc R
Issue
Row
aft
10
11
12
13
14
15
16
17
18
19
Dr
20
21
22
23
24
25
26
27
28
29
30 iew
31
32
33
34
35
36
37
38
39
40
41
42
43
ev
44
45
46
47
48
49
50
51
cR
52
53
54
55
56
57
58
59
60
61
62
bli
63
64
65
66
67
68
69
70
71
Pu
72
73
74
75
76
77
78
79
80
81
82
83
84
85