Professional Documents
Culture Documents
Hse Inspection Checklist
Hse Inspection Checklist
Hse Inspection Checklist
Department
HSE INSPECTION CHECKLIST HSEP05-F01
REV 0(01/10/2021)
OK /
ITEM DESCRIPTION YES
NO REMARKS
1 PUBLIC AND SITE VEHICULAR TRAFFIC CONTROL
1.1 Are trained flagmen provided to control vehicular traffic? / Not provided
1.2 Are the flagmen provided with necessary PPE and equipment? /
1.3 Are traffic signage and safety equipment provided? / Not provided
1.4 Condition of signage and safety equipment’s well maintained? N/A
2 WASH TROUGH
2.1 De-silting of wash trough and silt trap carried out? / No wash trough
2.2 Washing equipment’s including standby unit in good condition? N/A
OK /
ITEM DESCRIPTION YES
NO REMARKS
7 CONSERVATION OF ENERGY
7.1 Are computers and copiers using the ‘power saving’ option? N/A
Are equipment switched off when not in use for a period of
7.2 /
time?
7.3 Are lights switched off when not needed? /
Are all doors, windows and entrances of room properly closed
7.4 N/A
when air- condition is switched on?
7.5 Are water taps properly turned off after used? /
8 WELFARES
8.1 SITE UTILITIES
a Provision of clean water from tap? /
b Sufficient toilet provided for workers at the workplace? /
c Site toilets serviced on schedule? N/A
d Site toilets in clean and working condition? / Need to clean
Worker quarters, corridors, staircases, kitchens, bathing and
e N/A
toilets area sufficiently illuminated?
f Are the essential area light fittings been abused? /
g Are worker quarters sufficiently ventilated naturally? N/A
9 HOUSEKEEPING
9.1 CLEANLINESS
a Are site surrounding and workplace in clean and tidy condition? / Need to improve
b Are debris from refuse chute cleared away on time? N/A
Are worker quarters, bathing and toilets area in clean and tidy
c N/A
condition?
d Joint housekeeping carried out? /
e Centralized refuse bin cleared on schedule? / Need to provide
f Are relevant signage posted and in good condition? /
9.2 MATERIALS STOCKS
a Are materials stocks stacked properly and promptly? / Untidy
b Are materials stocks stacked up in a safe manner? / Air-cond units
c Are materials stacked at near open edge of floor? /
Safety and Health
Department
HSE INSPECTION CHECKLIST HSEP05-F01
REV 0(01/10/2021)
OK /
ITEM DESCRIPTION YES
NO REMARKS
10 SITE PEST CONTROL
10.1 Are pest control carried out on schedule?
10.2 Are different types of chemicals used for control?
Are the usages of chemicals rotated to prevent immune of the
10.3
pest?
12 PILING
12.1 PILE DRIVING
a Are concrete pile stocks stacked in a safe manner? N/A
Are piling equipment inspected by designated person before
b N/A
every start work?
c Stability of adjacent structures checked? N/A
Ground condition inspected by designated person before
d N/A
placing or advancing of pile driver?
e Are surrounding public or structure safe from piling activities? N/A
13 HOT WORKS
a Are hot work activities controlled? /
b Are surrounding hazards removed? /
c Are the welding cables checked before start work? /
d Are gas cylinders placed up right and in safe manner? Using welding machine
14 FENCING OF MACHINERY
14.1 Are exposed rotary parts of a machine properly covered up? /
15 EXCAVATION
15.1 Affected adjoining structures stability checked?
15.2 Stability and condition of sheet piles / shoring checked?
Are open sides of the excavation guarded by adequate
15.3 N/A
barricades?
15.4 Suitable warning signage displayed and in good condition? N/A
15.5 Condition of ladders or staircases well maintained? N/A
Are water pumping equipment and standby unit well maintained
15.6 N/A
and in good working condition at all time?
15.7 Temporary surrounding earth drain well maintained? N/A
Any excavated materials or super imposed loads placed less N/A
15.8 than 610mm away from the edge of the open excavation or
trenches?
15.9 Any machinery positioned in an unsafe manner? N/A
Safety and Health
Department
HSE INSPECTION CHECKLIST HSEP05-F01
REV 0(01/10/2021)
OK /
ITEM DESCRIPTION YES
NO REMARKS
16 LADDER AND STEP LADDER
Are the ladders in a good condition and without defective
16.1 / No timber ladder used
component parts?
16.2 Are the ladder placed in a level and firm footing? /
16.3 Are the top and bottom part of the ladder securely fixed? /
Are there ladder provided as mean of access from one level of
16.4 floor to another level that a person is liable to fall more than 3 /
meters height?
16.5 If yes to item (16.4) :
a Are the ladder provided with hand railing on both of its side?
b Are the ladder prevented from sagging?
Are the ladder extended at least 1 meter from edge of the top
c
floor level with rungs omitted from this extension?
17 CONFINED SPACE
17.1 Are all the confined spaces at site clearly marked? N/A
17.2 Are all entry controlled? N/A
17.3 Are the warning signage displayed and in good condition? N/A
Are the ventilator and standby unit in good working condition at
17.4 N/A
all time?
OK /
ITEM DESCRIPTION YES
NO REMARKS
22 WASTE MANAGEMENT
22.1 GENERAL WASTE AND RECYCLEABLES
Are separate bins provided for recyclable and non-recyclable
a / Need to provide
materials and marked?
b Are leakages or spillage contained to prevent pollution? /
c Are used oil contained up to prevent pollution? /
d Are office papers recycled for use? N/A
e Are usages of office paper monitored to reduce wastage? N/A
OK /
ITEM DESCRIPTION YES
NO REMARKS
25 PASSENGER HOIST
25.1 Are the hoist PMA displayed? N/A
25.2 Are the bottom floors strengthened for loading and vibration? N/A
Are the hoist and its components serviced and checked
25.3 N/A
monthly?
25.4 Are the numbers of passenger or loading limit displayed? N/A
25.5 Are the hoist operated by a trained person? N/A
25.6 Are the hoist checked and tested before every start work? N/A
25.7 Are the hoist and power source locked up when not in use? N/A
26 CHUTE
26.1 MATERIAL CHUTE
a Are chute constructed with planking of sufficient thickness? N/A
Are the chute bottoms strong and rigidly supported throughout
b N/A
its length at where the material strikes the chute?
c Are chute not in use removed or shifted into building? N/A
26.2 REFUSE CHUTE
Are the refuse chute (more 12 meters height) constructed
a N/A
accordingly to design and drawing of Professional Engineer?
Are fence and splashboards constructed at around the outlet
b N/A
end area?
c Are entries to the outlet area controlled? N/A
d Are there warning signage posted and in good condition? N/A
Safety and Health
Department
HSE INSPECTION CHECKLIST HSEP05-F01
REV 0(01/10/2021)
OTHER OBSERVATIONS :
- Site were found satisfactory. Minor comments such as housekeeping & materials arrangement need
to implement & maintained.
- Need to provide first aid kit based on FMA 1967 Regulation 38 (2) (1) Fourth Schedule.
- Box A (1-10 workers) / Box B ( 11-50 workers) / Box C (>50 workers)
DESIGNATION :
DATE :