A2 Fundamentals EN

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 75

Elevator Design

Fundamentals

A2
MAY 22, 2024, ©2024 DIGIPARA GMBH
Recommendation
ONLINE TRAINING

Are you an attendee in a DigiPara Liftdesigner online training module?


We recommend to print these out in advance so that you have a handout for your own editing
and for your notes during your training.

Page - 2 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Agenda

A2.1 Product Options


▪ Product Options

A2.2 Practical Examples: General


▪ Rail Bracket Fixing Options
▪ Shaft Door Anchor Rails
▪ Entrance Pocket
▪ Additional Sill Options
▪ Car Balustrade
▪ Scaffoldings
▪ Hall Button & Hall Display

Page - 3 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Agenda

A2.3 Practical Examples: Traction Elevator


▪ Counterweight Location
▪ Pulley Beam Settings
▪ Gear Base Construction
▪ L-shaped Car Frame

A2.4 Practical Examples: Hydraulic Elevator


▪ Rail Bracket Fixing Options
▪ Machine Room Basic Settings
▪ MRL

Page - 4 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Agenda

A2.5 Summary
▪ Custom Q&A‘s

Page - 5 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
6
Training Preparation
CREATE AN ELEVATOR WITH THE FOLLOWING SPECIFICATIONS:

Shaft Wizard Further specifications


▪ 5 floors ▪ Car size
▪ Typical floor to floor distance 3000 mm ▪ Car width : 1600 mm
▪ Car depth : 1400 mm
▪ Consider travel – no
▪ Create building floor levels - no ▪ Entrances
▪ Traction elevator 2:1 ▪ Front: all floors
▪ Rear: first and last level
▪ 13 persons / 1000 kg, 1 m/s
▪ Individual Floor to Floor Distance
▪ Machineroom ▪ Pit: 1200 mm
▪ Below / left ▪ E1: 2900 mm
▪ Car roping ▪ E2: 3000 mm
▪ 2 pulleys below ▪ E3: 3000 mm
▪ with CW safety gear ▪ E4: 3800 mm

▪ Counterweight roping ▪ Save the project under the following file name:
▪ 1 pulley on top LDTrainingSample.ld3
▪ Counterweight left
▪ Sheet Templates
▪ LD Installation Drawing
▪ LD Typical Views For Your Elevator
Page - 6 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Product Options
8
BIM Components & Product Options
A2.1 PRODUCT OPTIONS

Are available by default for some of the


DigiPara Liftdesigner BIM components E.g.
for:
▪ Rail brackets
▪ Traction machines
▪ Gear frames
▪ Car frames
▪ Etc.

Page - 8 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
9
BIM Components & Product Options
A2.1 PRODUCT OPTIONS

Enabling and disabling:


▪ Via property
▪ Selected Product Options
▪ Product Options can consist of one or more
profiles

▪ Switching off the rail bracket wall fixing profiles.

Page - 9 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
A2.2
Practical Examples:
General

MAY 22, 2024, ©2024 DIGIPARA GMBH


11
General
A2.2 PRACTICAL EXAMPLES: GENERAL

Rail Bracket Fixing Options


Entrance Pocket
Additional Sill Options
Car Balustrade
Scaffoldings
Hall Button & Hall Display

Page - 11 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Rail Bracket Fixing Options
13
Rail Bracket Fixing Options
A2.2 PRACTICAL EXAMPLES: GENERAL

Can be changed
▪ via the Rail brackets list

▪ The Rail brackets properties can be displayed


by selecting a single bracket in the drawing
and selecting the Rail brackets object via the
Breadcrumb window afterwards.

Page - 13 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
14
Rail Bracket Fixing Options
A2.2 PRACTICAL EXAMPLES: GENERAL

Different Fixing Options

1 Anchor Rail 2 Anchor Rails Separator Beam

Page - 14 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
15
Rail Bracket Fixing Options
A2.2 PRACTICAL EXAMPLES: GENERAL

Adjust anchor rail length


„Use standard lengths“
▪ YES (default) -> Select fixed length set up
via BIM Libary
▪ NO -> Set length manually

If a manual length is set


first and you reactivate
the standard lengths, the
closest fixed length will be
chosen

Page - 15 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
16
Rail Bracket Fixing Options
A2.2 PRACTICAL EXAMPLES: GENERAL

Adjust anchor rail spacing


▪ Select Anchor rail distance (AR_DIST)
-> via Breadcrumb or Datatree
Or
▪ Select Dimension in the View Frame
▪ It is also possible to set up the anchor rail
wall distance

Page - 16 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
17
Rail Bracket Fixing Options
A2.2 PRACTICAL EXAMPLES: GENERAL

Concrete Beam for Anchor Rails

Page - 17 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Shaft Door Anchor Rails
19
Shaft Door Anchor Rails
A2.2 PRACTICAL EXAMPLES: GENERAL

Can be added
▪ via the ShaftDoor using the
DoorFixingPointList Properties

Page - 19 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
20
Shaft Door Anchor Rails
A2.2 PRACTICAL EXAMPLES: GENERAL

Can be added
▪ via the ShaftDoor using the
DoorFixingPointList Properties

Page - 20 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Entrance Pocket
22
Entrance Pocket
A2.2 PRACTICAL EXAMPLES: GENERAL

Display the Pocket properties


▪ The Entry Pocket properties can be displayed
by selecting the landing door in the drawing
first and selecting the Entry Pocket object via
the Breadcrumb-Data tree window afterwards.

Page - 22 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
23
Entrance Pocket
A2.2 PRACTICAL EXAMPLES: GENERAL

Editing the entry pocket


▪ The Entry Pocket automatically gets created for
all entries on the corresponding shaft wall. It
can be added to an individual entry only by
changing the Grouping property to This pocket
is different.

Page - 23 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Additional Sill Option
25
Additional Sill Option
A2.2 PRACTICAL EXAMPLES: GENERAL

Display the Entry properties


▪ The Entry properties can be displayed by
selecting the entry concrete in a vertical view
(in Edit mode -> hatches turned off)

Page - 25 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
26
Additional Sill Option
A2.2 PRACTICAL EXAMPLES: GENERAL

Select from 3 different sill options


▪ The Add. sill option will be applied to all entries on the corresponding shaft wall

No Foundation drip lip Foundation pocket

Page - 26 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
27
Additional Sill Option
A2.2 PRACTICAL EXAMPLES: GENERAL

Set the Add. Sill option individually for just 1


entrance
▪ The Grouping property of the Sill support unit
is used to apply the Add. Sill option to a single
entrance only. The property must be set before
applying the Add. Sill option.

Page - 27 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Car Balustrade
29
Car Balustrade
A2.2 PRACTICAL EXAMPLES: GENERAL

Display the Car Balustrade properties


▪ The Car balustrade properties can be displayed
by selecting the car in the drawing first and
selecting the Car balustrade object via the
Breadcrumb window afterwards.

Page - 29 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
30
Car Balustrade
A2.2 PRACTICAL EXAMPLES: GENERAL

Activating and selecting the car balustrade

Page - 30 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
31
Car Balustrade
A2.2 PRACTICAL EXAMPLES: GENERAL

Configuring the balustrade

Page - 31 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Scaffoldings
33
Scaffoldings
A2.2 PRACTICAL EXAMPLES: GENERAL

Display the Assembly platforms

The Assembly platforms can be


activated via the corresponding
button in the Component Visibility
ribbon group

Page - 33 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
34
Scaffoldings
A2.2 PRACTICAL EXAMPLES: GENERAL

Quantity
▪ The number of armor platforms per
floor can be set via the group and Setting extension
shaft configurator.

Page - 34 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
35
Scaffoldings
A2.2 PRACTICAL EXAMPLES: GENERAL

Location
▪ The position is set above the
respective dimension in the vertical
section.
▪ Example: Set a height of 2500 mm for
the newly inserted Scaffolding to move
it into the shaft head.

Page - 35 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Hall Button & Hall Display
37
Hall Button & Hall Display
A2.2 PRACTICAL EXAMPLES: GENERAL

Hall Button
▪ Type
▪ can be set individually for the
top and bottom floors and for
the intermediate floors

Page - 37 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
38
Hall Button & Hall Display
A2.2 PRACTICAL EXAMPLES: GENERAL

Hall Button
▪ Position

▪ is automatically positioned in the right


wall by default

▪ different positioning options can be


defined via the associated properties
window

Page - 38 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
39
Hall Button & Hall Display
A2.2 PRACTICAL EXAMPLES: GENERAL

Hall Button
▪ Hole
▪ The hole of the control panel can be changed
or adapted via the properties.
▪ The associated through-hole can also be
edited using the corresponding properties.

Continuous wall opening


(default setting)

Page - 39 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
40
Hall Button & Hall Display
A2.2 PRACTICAL EXAMPLES: GENERAL

Hall Display
▪ Position

▪ is positioned in automatically in
the door (default setting)

▪ can be defined via the associated


properties window

Page - 40 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
41
Hall Button & Hall Display
A2.2 PRACTICAL EXAMPLES: GENERAL

Hall Button & Hall Display


▪ can be shown and hidden via
the properties on all floors for
the elevator project

Page - 41 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
A2.3
Practical Example:
Traction Elevators

MAY 22, 2024, ©2024 DIGIPARA GMBH


43
Practical Example: Traction Elevators
A2.3 PRACTICAL EXAMPLES: TRACTION ELEVATORS

Changing the counterweight location


Changing the pulley beam settings
MRL Gear Base Construction Unit
L-shaped Car Frame

Page - 43 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Counterweight Location
45
Counterweight Location
A2.3 PRACTICAL EXAMPLES: TRACTION ELEVATORS

Changing the counterweight location via the Rope Wizard


▪ For existing projects

▪ The Rope Wizard can be activated via the traction machine, the
counterweight, the pulley or the pulley beam properties.

Page - 45 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
46
Counterweight Location
A2.3 PRACTICAL EXAMPLES: TRACTION ELEVATORS

▪ Change the counterweight location via the Rope Wizard dialog 4/5

Page - 46 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Pulley Beam Settings
48
Pulley Beam Settings
A2.3 PRACTICAL EXAMPLES: TRACTION ELEVATORS

Changing the pulley beam settings of the


Car-/ CW frame
▪ Via the pulley beam properties

▪ The Pulley Beam properties can be


activated
▪ via the Pulley Beam link in the Breadcrumb

Page - 48 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
49
Pulley Beam Settings
A2.3 PRACTICAL EXAMPLES: TRACTION ELEVATORS

Angle and location


▪ The angle and location of the car and CW
pulley beams gets set via the Angle and Pulley
Location properties

Page - 49 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
50
Pulley Beam Settings
PRACTICAL EXAMPLES: TRACTION ELEVATORS

Changing the pulley beam settings of the


additional pulley beams
▪ Via the pulley beam properties

Page - 50 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
51
Pulley Beam Settings
A2.3 PRACTICAL EXAMPLES: TRACTION ELEVATORS

Angle and location


▪ The angle and location of the add.
pulley beams can be set
▪ via the P*X- / P*Y- and the Orthogonal
properties

Page - 51 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Gear Base Construction Unit (MRL)
53
Training Preparation
CREATE AN ELEVATOR WITH THE FOLLOWING SPECIFICATIONS:

Shaft Wizard Further specifications


▪ 5 floors ▪ Car size
▪ Typical floor to floor distance 3000 mm ▪ Car width : 1600 mm
▪ Car depth : 1400 mm
▪ Consider travel – no
▪ Create building floor levels - no ▪ Entrances
▪ Traction elevator 2:1 ▪ Front: all floors
▪ Rear: first and last level
▪ 13 persons / 1000 kg, 1 m/s
▪ Individual Floor to Floor Distance
▪ Drive Location in the shaft head (MRL) ▪ Pit: 1200 mm
▪ Car roping ▪ E1: 2900 mm
▪ 2 pulleys below ▪ E2: 3000 mm
▪ with CW safety gear ▪ E3: 3000 mm
▪ E4: 3800 mm
▪ Counterweight roping
▪ Save the project under the following file name:
▪ 1 pulley top
▪ Counterweight left A2_MRL_Training.ld3
▪ Sheet Templates
▪ LD Installation Drawing
▪ LD Typical Views For Your Elevator
Page - 53 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
54
Gear Base Construction Unit (MRL)
A2.3 PRACTICAL EXAMPLES: TRACTION ELEVATORS

Can be activated
▪ via the Properties docking window

▪ Selecting the Gear Base Construction


▪ via the properties of the category [0020] items

Page - 54 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
55
Gear Base Construction Unit (MRL)
A2.3 PRACTICAL EXAMPLES: TRACTION ELEVATORS

Selecting the common gear base construction


▪ And enabling / disabling component profiles
▪ via the Product Options

Page - 55 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
56
Gear Base Construction Unit (MRL)
A2.3 PRACTICAL EXAMPLES: TRACTION ELEVATORS

After customizing the corresponding component properties and dimensions


▪ Profile position, length, height, etc.

Page - 56 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
L-shaped Car Frame
58
L-shaped Car Frame
A2.3 PRACTICAL EXAMPLES: TRACTION ELEVATORS

Must be selected manually


▪ For non MRL elevators after the shaft wizard has been finished
▪ Via the Component Navigator

Page - 58 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
59
L-shaped Car Frame
A2.3 PRACTICAL EXAMPLES: TRACTION ELEVATORS

Possible result after exchanging the car frame and the following, additional changes
▪ Changing the car frame location
▪ Modifying the rail brackets
▪ Defining the distance between guides

Page - 59 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
A2.4
Practical Examples:
Hydraulic Elevators

MAY 22, 2024, ©2024 DIGIPARA GMBH


61
General
A2.4 PRACTICAL EXAMPLES: HYDRAULIC ELEVATORS

Rail Bracket Fixing Options


MRL

Page - 61 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Rail Bracket Fixing Options
63
Rail Bracket Fixing Options
A2.4 PRACTICAL EXAMPLES: HYDRAULIC ELEVATORS

Can be configured manually


▪ via the corresponding component properties

A rail bracket can consist of one or more


predefined fixing profile groups (similar to
Product Options), e.g.
▪ Standard profiles
▪ Cylinder fixing profiles
▪ Guide rail fixing profiles
▪ etc.

Page - 63 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
64
Rail Bracket Fixing Options
A2.4 PRACTICAL EXAMPLES: HYDRAULIC ELEVATORS

Switching off the Jack fixing profiles of the selected rail bracket

Page - 64 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
Machine Room Basic Settings
66
Machine Room Basic Settings: Dimensions
A2.4 PRACTICAL EXAMPLES: HYDRAULIC ELEVATORS

The machine room dimensions can be set individually


▪ In the properties window under [0250] Dimensions

Page - 66 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
67
Machine Room Basic Settings: Positioning
A2.4 PRACTICAL EXAMPLES: HYDRAULIC ELEVATORS

The machine room can be positioned individually in height (z-direction)


▪ Example: POS_DZ = 13150

Page - 67 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
68
Machine Room Basic Settings: Positioning
A2.4 PRACTICAL EXAMPLES: HYDRAULIC ELEVATORS

The machine room can be positioned in the same way in x and y direction
▪ In the properties window under [0251] Position
▪ Example: POS_DX0 = -5000 & POS_DYO = 2000

Page - 68 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
MRL
70
MRL
A2.4 PRACTICAL EXAMPLES: HYDRAULIC ELEVATORS

Hydraulic elevators can be created manually


▪ Via the machine room Machine room-less mode property

Page - 70 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
71
MRL
A2.4 PRACTICAL EXAMPLES: HYDRAULIC ELEVATORS

Machine room components are placed in the shaft pit automatically


▪ They can be deleted, moved
▪ via the corresponding dimensions and component properties

Page - 71 - May 22, 2024 DigiPara® Liftdesigner Online Training – A2 Elevator Design Fundamentals| © 2024, DigiPara GmbH
A2.5
Summary & custom
Q&A‘s

MAY 22, 2024, ©2024 DIGIPARA GMBH


Congratulations
You reached the next level

© 2024 DigiPara GmbH, www.digipara.com


Your instructor will be
available for individual
questions after the module
training.

training@digipara.com
training@digipara.com

MAY 22, 2024, ©2024 DIGIPARA GMBH


© 2024 DigiPara GmbH
www.digipara.com

You might also like