BHUBANESWAR - 751025 CELL: 9937344440,7894468743 MRS/N.D.T /2024/CRANE/VEDANT/TC / 1 11-Mar-2024 ULTRASONIC EXAMINATION REPORT Procedure : ASME Sec -V 1 Name of Occupier or the Factory M/s VEDANT ALMUNIUM LIMITED 2 Address of the Factory M/s VEDANT ALMUNIUM LIMITED, LANJIGARH, ODISHA. 3 Name of the Equipment: HYDRAULIC MOBILE CRANE Reg. No HR 85 F 3324 Year of manufacturing 2015 Name of the Owner M/s. SARENS HEAVY LIFT INDIA PVT. 4 Present Configuration of at Site: NDT Machine Deails Model-DS702. SR NO-S7037KWA. Test Type NDT of metallic structure of equipment by using ultrasonic Instrument Used Ultrasonic Flaw Detector, Probe Used – Normal & Angle - 450 Calibration block IIW-V-I,V-II & Reference block Surface Condition Smooth Acceptance Standard ASME SEC VIII Couplant GREASE/SAFE20-40 Calibrated to 100 & 200mm screen with DAC sensitivity set at 80% full screen height from referance SDH 16mm calibration block 5 DETAILS OF EXAMINATIONS / TESTS CONDUCTED S.NO Name of the Parts Inspected No. of Points Observation Remarks
1 LIFTING HOOK-1 2 No Recordable Flaw Acceptable
Observed 2 BOOM PIN-1 2 No Recordable Flaw Acceptable Observed 3 BOOM PIN-2 2 No Recordable Flaw Acceptable Observed 4 BOOM PIN-3 2 No Recordable Flaw Acceptable Observed 5 BOOM PIN-4 2 No Recordable Flaw Acceptable Observed 6 OUT TRIGER LHS 1 2 No Recordable Flaw Acceptable Observed 7 OUT TRIGER LHS 2 2 No Recordable Flaw Acceptable Observed 8 OUT TRIGER RHS 1 2 No Recordable Flaw Acceptable Observed 9 OUT TRIGER RHS 2 2 No Recordable Flaw Acceptable Observed 10 CONNECTING PIN-1 4 No Recordable Flaw Acceptable Observed 11 CONNECTING PIN-2 4 No Recordable Flaw Acceptable Observed 6 Particulars of any defects affecting the safe working load found at any such thorough examination or after annealing and of the Nil at the time of examination, steps taken to remedy such defects: 7 Next Due date for testing 11-Mar-2025 Signature: Scanned with AnyScanner