Lifeis in the

details.

Trunking
Headwalls

Envirom Bedhead Trunking


Envirom Bedh the ward ambience less clinical, Luminaires can be fitted with DALI
Envirom Bedhead Trunking
Improving the patient environment more inviting, home like and relax- or DSI compatible ballasts, offer-
is the key driver behind the design ing. ing the hospital a high degree of
of the Envirom bedhead trunking functional control, whilst minimis-
system. The use of integral lighting Front and side panel fascia plates ing energy consumption - helping
and coloured fascia panels opens are pre cut before being sent away saving our environment.
up new possibilities to enhance for powder coated painting. This
ward decor. enables the panels to be installed Totally Configurable
next to each other with no gaps, Each trunking unit is custom
illiminating a potential dust trap manufactured to your specific
Superior Aesthetics and problem for cross infection.
There is a strong emphasis on requirements. Our team of de-
Flush mounted electrical com- signers provide expert advice and
improving the patient environ-
ponents also provide an easy to support, and will even help you
ment in modern hospital design.
clean work surface. develop specifications for your
The way a patient feels is affected
by many factors, including the project.
environment they are in. Careful Integral Lighting
selection of colour, textures and Integral high efficiency fluorescent Hospitals all over the World
lighting schemes within the patient luminaires provide a cost effective have benefited from the Envirom
environment have been proven to method of achieving general ward bedhead trunking system. It is
aid the recovery process. illumination and patient reading possible to fit medical gas termi-
lighting. nal units and electrical sockets
Envirom Bedhead Trunking is sup- to many national standards, as
plied with coloured plates, so the The Envirom Bedhead Trunking well as equipment rail, nursecall,
bedhead system can compliment system is designed to be used with data sockets, telephone jacks,
any chosen decor, enhancing the T8, T5 or PLL fluorescent tubes, light switches, earth sockets, LED
patient environment. This makes with high frequency electronic examination and reading lamps.
fixed output or dimmable ballasts.
RAL9010 RAL9001 RAL7035 RAL6019 RAL5024 RAL3015
Pure White Cream Light Grey Pastel Green Pastel Blue Light Pink

Optional
downdrop

1 x 54W T5 Indirect Room Light


170
1095
Relay

90
108

86
130

1800mm
to floor

O2 MA 4 Va c
M E D AE S
M E D AE S

M E D AE S
G e m 10

G e m 10

G e m 10

0 0 86 0 0 86 0 0 86

85 135 135 150 2 x 24W T5 Reading Light 130 160 160 131
Feed

200 Equipment rail 545mm 670

1240

1900
Downlight switch/dimmer
Uplight switch/dimmer

Twin unswitched 13A

Twin unswitched 13A

Twin unswitched 13A


Gem 10 Medical Air

Nursecall Provision

Telephone socket

(essential circuit)
Gem 10 Vacuum
Gem 10 Oxygen

(normal circuit)

(normal circuit)
Equipment Rail

(secondary)
RJ45 cat. 5e

Cross-Section
O2 MA 4 Va c
M E D AE S
M E D AE S

M ED A E S
G e m 10

G e m 10

G e m 10

0 0 86 0 0 86 0 0 86
head Trunking
Envirom Vertical Headwalls A Range of Options A Solution for Every Area
Improving the patient environ- There are two standard widths Envirom headwalls are ideally
ment is the key driver behind the of headwall, called V Sys (wid- suited for general and interme-
design of the Envirom headwall est) and NV Sys (narrow). Due diate acuity care areas in the
systems. The use of coloured to the substantial service car- hospital, especially those requir-
fascia panels opens up new rying capacity of the V Sys, it is ing a large number of services to
possibilities to enhance ward possible for a single headwall to be close to the patient bed. For
decor. Envirom headwalls also supply two patient bedspaces, high acuity areas of the hospital
provide a cost effective method one either side of the unit. please see our brochure detail-
of installing a wide range of ser- ing Atlas and Coronus Ceiling
vices in a single factory built and In addition to the headwall sys- Pendant Systems.
tested unit. tem, luminaires can be provided
for general illumination, reading
and examination lighting.

In addition to pure white, a range of 5 standard coulours is available. Colours printed here are for indication purposes only
as limitations in the printing process do not allow an exact representation. Colour swatches are available on request.

RAL9010 RAL9001 RAL7035 RAL6019 RAL5024 RAL3015


Pure White Cream Light Grey Pastel Green Pastel Blue Light Pink

Examination Lamp
Medical Equipment
Rail 30mm x 10mm Nursecall Provision

RJ45 cat. 5e

Wall Seals
Telephone socket
(secondary)
O2 O2 O2 MA 4
M E D AE S
M ED AE S

M ED AE S

M ED AE S
Ge m 10

Ge m 10

Ge m 10

Ge m 10

0 0 86 0 0 86 0 0 86 0 0 86

Gem 10 Oxygen
200

Gem 10 Medical Air


MA 4
M ED AE S

Ge m 10

0 0 86

MA 4 Va c Va c
M E D AE S
M ED AE S

M ED AE S
Ge m 10

Ge m 10

Ge m 10

Gem 10 Vacuum 0 0 86 0 0 86 0 0 86

Medical Equipment
Rail 30mm x 10mm
Va c
M ED AE S

Ge m 10

0 0 86

Unswitched 13A sockets


(normal circuit)
100

Unswitched 13A sockets


(essential circuit)
100

438 125
Twin unswitched 13A sockets
(normal circuit) 715

452

Envirom NV Sys Envirom V Sys Side


View
PB7/5-100112

5
5

7 7

6 5

Key Features Benefits


1. Superior aesthetics • Enhances the patient environment
2. Supplied factory pre-piped and • Ensured quality and speed of installation on site
pre-wired
3. Flush mounted components • Easy to wipe clean and elimination of dust traps
4. Wall mounted luminaire • Compliments the vertical headwalls
5. Incorporating Gem 10 medical gas • The World’s most reliable terminal unit, now with anti-microbial
terminal units additive to help minimise cross infection
6. Painted fascia plates • Easy to clean with no panel gaps provides a seemless finish
7. Integral and retrofit equipment rail • Allows for mounting of accessories such as baskets, IV poles etc
8. Exam and reading lamps • Trunking mounted brackets provide seamless connection of
lighting accessories
9. Fully configurable • A wide range of electrical, ELV and medical gas components
enable endless options of connectivity
10. Robust extruded aluminium sections • Superior quality and strength

BeaconMedæs
Part of the Atlas Copco Group
Telford Crescent, Staveley,
Derbyshire, S43 3PF, England
Tel: +44 (0) 1246 474 242
www.beaconmedaes.com

You might also like