Pump House

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Plant Actual Notes

4 7.6
North 6° North 1. All dimensions are in millimeters and levels are in meters,
unless otherwise specified.
P-04038-A21A-10"

P-04045-A21A-10"

P-04052-A21A-10"

P-04059-A21A-10"

P-05010-A21A-10"

P-05017-A21A-10"
P-04066-A1M-10"

P-05003-A1M-10"

2. Structural details if shown like rack, stairs, supports etc., are


COP+12.327

COP+12.327

COP+12.327

COP+12.327

COP+12.327

COP+12.327

COP+12.327

COP+12.327

indicative. refer structural/civil drawings for the same.


3. Refer respective (Ele/Inst) drawing for detail information.
4. Check and Verify dimension/elevation at field before
Match Line-K fabrication/construction.
Ref.Dwg.No:
405796-MMD-00-XX-DR-PI-0115
A V
P-17001-A1M-6"
COP+11.148
A1M A21A A1M A21A A1M A21A A1M A21A A1M A21A A1M A21A P-04045-A21A-10"
P-04045-A21A-10"
COP+ 12.327
D COP+ 12.327
D
A1M A21A
P-17002-A1M-6" Key Plan
COP+11.148 SS Export Pump Suction Header
A1M A21A A1M A21A A1M A21A A1M A21A A1M A21A A1M A21A A1M A21A A1M A21A
P-06068-A21A-12"
P-06065-A1M-16"
N
P-06061-A21A-4" COP+ 11.282
COP+ 11.239
COP+11.120
P-06062-A21A-4"
COP+11.120 FFL+10.800
FFL+10.800
P-06063-A1M-4"
COP+11.120
P-06064-A1M-4" Section B Section C
COP+11.120
1:33 - 1:33 -
P-06077-A1M-8"
COP+11.185
P-04045-A21A-10"
COP+ 12.327
P-06065-A1M-16"
COP+11.282 A1M A21A
A1M A21A C A1M A21A C A1M A21A A1M A21A A1M A21A A1M A21A
Abbreviations
P-17001-A1M-6"
COP+ 11.148
FGL Finished Ground Level Existing Area D Drain V Vent
FFL Finished Floor Level Paved Area IP Insulation Protection
TOF Top of foundation Structural work IH Insulation Hot
TULF Pump Discharge Line
TOS Top of Steel work Pipe rack
FFL+10.800 IC Insulation Cold
BOP Bottom of Pipe
P-06066-A1M-10" COP Center of Pipe Pipe Up ▼ = Center of Pipe
COP+11.214
Section ℄ Center Line Pipe Dn. Ñ = Top of Steel
D Lvl Level FOF Face of Flange work/Bottom of
A1M A21A A1M A21A A1M A21A A1M A21A A1M A21A A1M A21A FSU Flat Side Up FTA Float Trap Assembly Pipe/Top of foundation/
1:33 - FSD Flat Side Down Finished Floor
PS-xx Pipe Support
Typ Typical Level/Face of Flange
RC-xx Rack column
Rest Axial Stop
Guide
Barred Tee
COP+11.570
Pigged Oil Pipe Line
P-06067-A21A-12" COP+11.120 Referance drawings
COP+11.239
A21A A1M A21A A1M
P-06077-A1M-8" Pigged Oil Pipe Line Recirculation Line 1) 405796-MMD-00-XX-DR-PR-006 xxx.11 Pump House P & I Diagram
COP+ 11.185
COP+ 11.120 10.982 COP+11.120 2) 405796-MMD-00-XX-DR-PR-007 xxx.11 Pump House P & I Diagram
FFL+10.800 FFL+10.800 FFL+10.800 FFL+10.800 3) 405796-MMD-00-XX-DR-PI-0003 Layout and Sections of Equipment
Pump House Area xxx
4) 405796-MMD-00-XX-DR-DR-001 Plot Plan
4" Tapping Detail of 4" Tapping Detail of 2" Drain Detail of 4" Tapping Detail of 5) 405796-MMD-08-XX-DR-PI-0005 Layout and Sections of Equipment
SS Inter Tank Transfer Line Pigged Oil Pipe Line Pigged Oil Pipe Line Recirculation Line TLF Area xxx
P-06068-A21A-12"
COP+11.239
V
B V
B V V V V V V
B
P-07065-A21A-4"
COP+11.120
P-07066-A1M-4" V
COP+11.120 Hold List
P-07067-A21A-4"
COP+11.120
P-07068-A1M-4"
COP+11.120
FFL+10.800
P-175 P-04038-A21A-10"
COP+ 11.848
FFL+10.800
A

FFL+10.800
D
Section A
1:33 -
V V V V V V V V
P-175

P-176

P-177

P-178

P-179

P-180

P-181

P-182
D
D D D D D
D D
CL Lvl. of Valve
EL.+11.886 CL Lvl. of Valve
CL Lvl. of Valve EL.+11.689
EL.+11.847
C
3 1 Match Line-'C-C'
A Ref.Dwg.No:
405796-MMD-00-XX-DR-PI-0118
4 5 Dist. From Grid-6 6 7
Sr.No. Line No. COP Dist.
1 N2-26110-A21A-2" +14.952 745
Match Line-'B-B' Match Line-'M'
2 PA-22047-A25A-2" +14.952 185
Ref.Dwg.No: 3 RW-20049-A25A-1 1/2"-IP25 +15.057 185
Ref.Dwg.No:
405796-MMD-00-XX-DR-PI-0116 405796-MMD-00-XX-DR-PI-0402

You might also like