VIJAYAWADA-DHARMAPURI PIPELINE

PROJECT
DESIGN DOCUMENT FOR TEMPORARY CATHODIC PROTECTION SYSTEM

Mg
Avg Resistivity anode Mg anode
Zinc anode for
Sr. Normal Chainage in (Ohm-meter) TLP 2.5 kg 10 kg For Solid State Surge Pol
Location Grounding 20
No. Type (Km) at depth of 2 & Name For Carrier Decoupler diverter Coupon
kg for HT line
5 meter Carrier Pipe
Pipe
Cart Track Road
54 A+1 34.546 15.290 TS-54 1
Crossing
55 A 35.550 Open Field 19.970 TS-55

56 A+1 36.550 Open field 23.680 TS-56 1


400 KV HT 2
57 H 37.492 31.020 TS-57 1
LINE P
400KV HT Line
58 H 38.005 14.600 TS-58 2 1
Crossing
400KV HT Line
59 H+1 38.542 14.600 TS-59 1 2 1
Crossing
Muneru River
60 B 38.924 13.090 TS-60 1 1
Crossing (HDD)
Muneru River
61 B 39.705 11.710 TS-61 1
Crossing (HDD)
Metalled Road
62 A 40.864 7.250 TS-62
Crossing
63 A+1 41.850 Open field 8.010 TS-63 1

64 A 42.850 Open field 8.410 TS-64

65 A+1 43.826 Nala Crossing 8.250 TS-65 1

DOCUMENT NO : HPCL-VDPL-TCP-DD-001 PAGE 47 OF 67