Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ENERGY & POWER

NMC SYSTEM
Forsee‘s Energy & Power NMC system contains high Energy & Power NMC system is composed of the
energy and high power NMC pouch cell technology, following components:
liquid cooling and superior software and electronics. • Module E&P-NMC 7kWh–18kW–90V, with an efficient
Its modular architecture facilitates easier integration, in water thermal management system which provides
both series and parallel configurations, across multiple more consistent range in hot and cold climates, constant
markets and platforms: from electric and hybrid energy, better safety and longer battery life.
transportation (city cars, buses, trucks, tramways and • Advanced electronics, which monitor the voltage and
industrial vehicles) to smart grid applications (solar temperature of each cell within the system to help prevent
integration, residential storage and community energy overheating and overcharging. Electronics are also
storage and large-scale ESS). engineered to manage cell balancing and communicate
The chemistry and design of cell technology selected with the FORSEE POWER Battery Management
by FORSEE POWER enable excellent energy density Controller (BMC), providing a reliable interface for pack
and power-to-energy ratio within the system. High cycle diagnostics.
life and improved safety are also benefits of FORSEE The Energy & Power NMC system is a standard product
POWER’s design. in serial production with a proven track record with
global customers.

An Energy & Power NMC system


made of 7 modules E&P-NMC 7kWh
– 18kW – 90V, Battery Management
Controller (BMC) and Power
Distribution Unit (PDU).

system components

Module E&P-NMC Battery Management Power Distribution


7kWh – 18kW – 90V Controller Unit
SYSTEM TECHNICAL SPECIFICATIONS & CHARACTERISTICS SYSTEM VALIDATIONS & CERTIFICATIONS

Physical 1 2 3 4 5 6 7 FORSEE POWER Quality


ISO 9001
specifications Conditionss Unit Mod Mod Mod Mod Mod Mod Mod Management System
Voltage Electrical Regulation R100
Min. - V 65 130 194 259 324 389 454 Transportation Certification
UN DOT
Nominal - V 89 178 266 355 444 533 622 (Altitude / Thermal / Vibration /
3480
Shock / External Short Circuit)
End of charge - V 98 197 295 394 492 590 689
Safety Test (Penetration /
Max. (Regen.) - V 101 202 302 403 504 605 706 Ellicert
Immersion / Drop)
Current Humidity / Thermal & Mechani-
ISO12405-2
Max continuous cal shocks / Vibration
current in @ +25°C A 200
discharge High & Low Temperature / Salt
EN 60068-2
& Spray / Corrosion Resistance
Peak current in
@ +25°C @
discharge
SOC = 50%
A 300 Thermal Cycling ISO12405-2
(30 sec.)
Immersion / High Pressure
Max. continuous ISO 20653
@ +25°C H/A 1 Hour / 80A Sealing
current in charge
Peak current in @ +25°C, IP Class Water / Dust Tightness CEI 60529
A 300
charge (10 sec.) SOC = 50% ISO6737 /
EMC
Power ISO11452-2
Max. continuous
@ +25°C,
power in
SOC = 50%
kW 18 36 53 71 89 107 124 POWER VS. SOC
discharge
10s PEAK POWER (kW)
Peak power in
@ +25°C,
discharge kW 27 53 80 107 133 160 186
SOC = 50%
(30 sec.) Charge

Max. continuous @ +25°C,


kW 18 36 53 71 89 107 124
power in charge SOC = 50%
Discharge
Peak power in @ +25°C,
kW 27 53 80 107 133 160 186
charge (10 sec.) SOC = 50% 0% SOC
100% SOC
Energy
@ +25°C,
Energy kWh 7,1 14,2 21,3 28,4 35,5 42,6 49,7
C/2, BOL
@ +25°C, Wh/
Specific energy 87,7
BOL kg
@ +25°C,
Energy density Wh/L 129,9
BOL Usable energy at 1C (kWh)
@ +25°C,
Power density W/kg 219,3
BOL CONTINUOUS POWER (kW)
@ +20°C, %/
Self discharge < 1,54%
SOC = 50% Month
System Capacity 80Ah – 2 cells of 40Ah in //

Dimensions
Height - mm 274 - - - - - - Discharge
0% SOC
Width - mm 280 - - - - - -
Length without
- mm 670 - - - - - -
connectors Charge

Length with
- mm 713 - - - - - - 100% SOC
connectors
Volume - Liter 55 - - - - - -
Weight without Usable energy at 1C (kWh)
- kg 81 162 243 324 405 486 567
water
Weight with water - kg 83 166 249 332 415 498 581

FORSEE POWER SAS


Parc du Mandinet 1-3, rue des Campanules
77185 Lognes - France
+33 (0)1 60 95 32 27 / contact@forseepower.com www.forseepower.com
The information contained herein is provided solely for the purposes of general explanation and illustration, and is subject to modification without notice. No warranty or
guarantee is given in regards to the information contained herein or the referenced products. Please contact FORSEE POWER for the most current and relevant product
information for your particular application.