MEGHA ENGINEERING AND INFRASTRUCTURE LTD

POLAVARAM HYDRO ELECTIC PROJECT


WELDER PERFORMANCE QUALIFICATION RECORD

WELDER NAME : DHANANJAY KUMAR

WELDER NO : PHEP/WPQ-087

TEST DESCRIPTION
WPS FOLLOWED : MEIL/PHEP/WPS/02
SPECIFICATION OF BASE METALS (S) : IS 2062 E 300 BR
TESTED DATE : 9/15/2023
DIA OF PIPE : 9 mtr
TEST THICKNESS : 25 MM

TESTING CONDITION & QUALIFICATION LIMITS


RANGE QUALIFICATION AS
WELDING VARIABLES ACTUAL VALUE
IX

WELDING PROCESS SAW SAW


TYPE (MANNUAL/SEMI AUTO) USED SEMI AUTO SEMI AUTO
BACKING (METAL, WELDED, DOUBLE WELDED, ETC) : WITHOUT BACKING WITH & WEITH OUT
PLATE : √ PIPE (DIAMETER IF PIPE OR TUBE) : - 25MM PLATE 25 MM to 73 M
BASE METAL (P or S.NO TO P or S.NO) : P.NO -1 to P.NO -1 P.NO -1 to P.NO
FILLER METAL or ELECTRODE SPECIFICATION (S) : SFA/AWS A 5.17E M12K …………..
ALL F6 WITH OR WITH o
FILLER METAL F-Nos : F6
BACKKING
FILLET TYPE (SOLID/METAL or FLUX CORED/POWER) : SOLID SOLID
CONSUMABLE INSERT (GTAW or PAW) : NIL NIL
WELD DEPOSITE THICKNESS FOR EACH PROCESS …………. …………
GROOVE : 1G 1G
POSITION QUALIFIED
FILLET : ………… …………
BEVEL ANGLE : 35°-40° 35°-40°
VERTICAL PROGRESSION (UPHILL/DOWNHILL) : …………. ………….
INSERT GAS BACKING (GTAW/PA/GMAW) ; NA NA
CURRENT TYPE/POLARITY : DCEP DCEP

RESULT
VISUAL INSPECTION OF COMPLETE WELD : SATISFACTORY
ALTERNATIVE VOLUMETRIC RADIOGRAPHYVREPORT NO : SUES/RT/474
FILLET WELD FRACTURE TEST : NA
MACRO EXAMINATION : NA FILLET SIZE : x CONCAVITY/CONVEXITY : NA OTHER TEST : NA

WE CLARIFY THAT THE STATEMENTS IN THIS RECORD ARE CORRECT AND THE TEST COUPONS WERE PREPARED, WELDED AN
CONFORMANCE WITH THE REQUIREMENTS OF SECTION IX ASME BOILERS AND PRESSURE VESSEL CODE.

QUALITY INSPECTOR NAME & SIGN


TEST COUPON √
PRODUCTION WELD -

S
RANGE QUALIFICATION AS PER ASME SEC
IX

SAW
SEMI AUTO
WITH & WEITH OUT BACKING
25 MM to 73 MM
P.NO -1 to P.NO -1
…………..
ALL F6 WITH OR WITH or WITH OUT
BACKKING
SOLID
NIL
…………
1G
…………
35°-40°
………….
NA
DCEP

Y : NA OTHER TEST : NA

WERE PREPARED, WELDED AND TESTED IN


D PRESSURE VESSEL CODE.