CME Reg 03 - ME Work Inspection Report

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 10

MECHANICAL ELECTRICAL

INSPECTION REPORT
DOCUMENT LIST

No. DESCRIPTION INDEX NO. REMARKS

1 Grounding Works Report A


2 M/E Installation Report B
3 PLN Connection Report C

Prepared by, Approved by,


Sub Contractor
PT. Perissos Andalan Abadi PT. Smart Telecom

Name : Ariansyah Name : ……………………


Title : Project Manager Title :……………………...
Date : ……………..…… Date : ……………..……
Mechanical Electrical Works
Inspection Report
CME Regional

Inspection : Grounding System Date :


Site ID : NBTM_0079 Region : Sumbagut
Site Name : SUNGAI PANAS - BTS

1. Down Conductor
Using …….……... mm² continuous alluminum cable : OK NOT OK N/A

Connected directly to its copper plate / rod with bimetal connector : OK NOT OK N/A

Approved manufacture (big 4 manufacturer) : ……………………………………………

2. Air Terminal
Air Lightning Rod ………. mm² solid alluminum : OK NOT OK N/A

Installed with ………" galvanized pipe : OK NOT OK N/A

Length of Pipe ………………………………… : OK NOT OK N/A

Isolators are in place and in good condition : OK NOT OK N/A

3. Grounding Tower Legs / Pole Baseplate


Using type ………………. mm2 : OK Not OK N/A

Outdoor Flexible Pipe (Black Colour) : Yes No N/A

Every Tower Legs/Pole Baseplate : Yes No N/A

Connected to tower leg/pole baseplate with Scoen : Yes No N/A

4. Shelter Grounding
Ring plate Dimension 50 x 4 mm² : OK NOT OK N/A
Approved manufacture (big 4 manufacturer) : ……………………………………………

Connected Properly : OK NOT OK N/A

Main Grounding Bar to IGB : OK Not OK N/A

Connection to Grounding Perimeter :


OK Not OK N/A
Grounding Resistance : Ohm

5. Fence Grounding (for Greenfield only)


Using BC 50 mm² cable : OK NOT OK N/A

Outdoor Flexible Pipe, ………………………………………. : OK NOT OK N/A

…… points are grounded : OK NOT OK N/A


Mechanical Electrical Works
Inspection Report
CME Regional

Inspection : Grounding System Date :


Site ID : NBTM_0079 Region : Sumbagut
Site Name : SUNGAI PANAS - BTS

6. Grounding Rod
Solid copper, dia. ……….. inch, ……. m length : OK NOT OK N/A

Quantity …………………………. Pcs : OK NOT OK N/A

Distance between each rod : …… m

7. Ring Perimeter
Using BC 50 mm² cable : OK NOT OK N/A

Buried at least 0.8 m depth from finished ground level : OK NOT OK N/A

Distance from tower foundation : …… mm

9. External Grounding Bar (EGB)

Grounding Bar (Galvanize steel bar)


…… mm x ……mm x …… mm : OK NOT OK N/A

Having …… holes, dia ………… mm : OK NOT OK N/A

Installed with Isolator and


Stainless Steel Bolts and Nuts : OK NOT OK N/A

-……… m Below Antenna Level (Upper) : OK NOT OK N/A

-……… m Below Antenna Level (Middle) : OK NOT OK N/A

-……… m Below Antenna Level (Lower) : OK NOT OK N/A

Galvanize EGB closed to Inlet (FEP) : OK NOT OK N/A

10.a Collection Bar (MGB) - For Greenfield

Collection Bar made of …… mm x …… mm x …… mm solid copper plate with

…… holes, dia ………… mm : OK NOT OK N/A

Using Stainless Steel Bolts & Nuts : OK NOT OK N/A

Connection from Cooper Rod with Cad Weld : OK NOT OK N/A

Other Connection with Scoen : OK NOT OK N/A

Every cable is labeled properly : OK NOT OK N/A


Mechanical Electrical Works
Inspection Report
CME Regional

Inspection : Grounding System Date :


Site ID : NBTM_0079 Region : Sumbagut
Site Name : SUNGAI PANAS - BTS

10.b Collection Bar (MGB) - For Rooftop

Collection Bar made of …… mm x …… mm x …… mm solid copper plate with

…… holes, dia ………… mm : OK NOT OK N/A

Using Stainless Steel Bolts & Nuts : OK NOT OK N/A

Installed on Upper Control Box : OK NOT OK N/A

Installed on Lower Pit : OK NOT OK N/A

Every cable is labeled properly : OK NOT OK N/A

11. Grounding Pit


Dimension …… x …… x …… mm : OK NOT OK N/A

Cover & Position : OK NOT OK N/A

Padlock arrangement : OK NOT OK N/A

12. Grounding integration


All collecting bar integrated using stainless steel material : OK Not OK

Cad weld integration (…… points)


- …… points for driven rod : OK Not OK

- …… points at buried perimeter to tower grounding : OK Not OK

- …… point for bonding ground bar on inspection pit to perimeter : OK Not OK

- …… point for bonding driven rod of down conductor


to perimeter : OK Not OK

13. Grounding Measurement

Equipment Manufacturer (accredited manufacturer) : ……………………………………………………

Type : Analog Digital

Grounding Test and Position Lay-out : OK Not OK

Grounding Resistance ( < 1 Ohm ) : OK Not OK

14. Notes :

Prepared by, Reviewed & Supervised by, Approved by,


Sub Contractor Site Supervisor CME Manager
PT. Perissos Andalan Abadi PT. Smart Telecom PT. Smart Telecom

Name : Ariansyah Name : …………………… Name : ……………………


Title : Project Manager Title : ………………….. Title : …………………..
Date : ……………..…… Date : ……………..…… Date :……………………
Mechanical Electrical Works
Inspection Report
CME Regional

Inspection : M/E Installation Date :

Site ID : NBTM_0079 Region : Sumbagut

Site Name : SUNGAI PANAS - BTS

1. Power Distribution Box (ACPDB)


Approved Manufacture : ………………………………………………
(based on DSS approved vendors)

- Panel Box Dimension : x x mm

- Bolt on Ground Connector


Inside Box : OK Not OK

- Typewritten Directory Label : OK Not OK

- Acrylic for Inside Cover : OK Not OK

- Arrange Busbar in Distributed Phase (R, S, T, N & G)


: OK Not OK

- Branch Circuit Wires Are Arranged in Each Duct Cable/Gutter


: OK Not OK

- Branch Circuit Wires Are Arranged with Tie Wrap


: OK Not OK

- Wiring Diagram Available Not available

2. Component are installed and working properly

- Circuit Breaker : OK Not OK

- Terminal Block : OK Not OK

- Indicator Lamp (R, S, T phase) : OK Not OK

- Cable (big 4 manufacturer) : OK Not OK

- Relay : OK Not OK

- Timer : OK Not OK

- Magnetic Contactor : OK Not OK

- Fuses : OK Not OK

- ELCB : OK Not OK

- Arrester : OK Not OK

- Cable Gland : OK Not OK

- Cable Duct : OK Not OK N/A

- Thermostat : OK Not OK N/A


Mechanical Electrical Works
Inspection Report
CME Regional

Inspection : M/E Installation Date :

Site ID : NBTM_0079 Region : Sumbagut

Site Name : SUNGAI PANAS - BTS

- DC Fan : OK Not OK N/A

- Lighting Switch : OK Not OK

- AC Outlet : OK Not OK

- Indoor /Outdoor Lighting : OK Not OK

- Junction Box : OK Not OK

3. Circuit Breakers

Circuit Breakers …… A : pcs

Circuit Breakers …… A : pcs

Circuit Breakers …… A : pcs

Circuit Breakers …… A : pcs

4. Power Cable (For AC Power)


- Red Color For R Phase : OK Not OK

- Yellow Color For S Phase : OK Not OK

- Black Color For T Phase : OK Not OK

- Blue Color For Neutral : OK Not OK

- Green Yellow Color For Ground : OK Not OK

5. Power Cable (For DC Power)


- Red Color For Positive : OK Not OK

- Blue Color For Negative : OK Not OK

6. Cable Installation
- Cable Conduit : OK Not OK

- Cable Duct : OK Not OK N/A

7. Smoke Detector (if ordered by DSS)

- Manufacturer :

- Properly Working : OK Not OK N/A

8. Heat Detector (if ordered by DSS)

- Manufacture :

- Properly Working : OK Not OK N/A


Mechanical Electrical Works
Inspection Report
CME Regional

Inspection : M/E Installation Date :

Site ID : NBTM_0079 Region : Sumbagut

Site Name : SUNGAI PANAS - BTS

9. Fire Extinguisher
Manufacture :

Media/Gas Content : N/A

Fire Extinguisher - Portable : OK Not OK N/A

Type :

Fire Extinguisher - Thermatic : OK Not OK N/A

Type :

Indicator Validity (green area) : OK Not OK N/A

10. Air Conditioning

- Manufacturer :

- Inverter type : OK Not OK N/A

- Model : Indoor - Outdoor -

- Serial Number Indoor Unit 1 :

- Serial Number Indoor Unit 2 :

- Serial Number Outdoor Unit 1 :

- Serial Number Outdoor Unit 2 :

- Manual Operation Book : OK Not OK N/A

- Remote Control : OK Not OK N/A

- Galvanized Steel Cage/Bracket For Outdoor Unit


: OK Not OK N/A

- Piping Are Covered With Isolation Tape


: OK Not OK N/A

- Drain Water using PVC Pipe : OK Not OK N/A

- Freon Pressure …… psi : OK Not OK N/A

- Current level …… A : OK Not OK N/A

- Installation : OK Not OK N/A


Mechanical Electrical Works
Inspection Report
CME Regional

Inspection : M/E Installation Date :

Site ID : NBTM_0079 Region : Sumbagut

Site Name : SUNGAI PANAS - BTS

11 Lighting, 4 Pcs x 18 Watt : OK Not OK N/A

Lighting, 2 Pcs x 10 Watt : OK Not OK N/A

Lighting, 2 Pcs x 18 Watt : OK Not OK N/A


Emergency Lamp : OK Not OK N/A

Over Head/Bulk Lamp : OK Not OK N/A

Switch : OK Not OK N/A

12 Power Outlet Socket : OK Not OK N/A

13 DC Fan : OK Not OK N/A

Power ……x……… VDC : OK Not OK N/A

Relay Control : OK Not OK N/A

14 Air Intake (inlet) : OK Not OK N/A

Air Intake (inlet) Cage : OK Not OK N/A

15 Feeder Inlet - FEP : OK Not OK N/A


16 Notes

Prepared by, Reviewed & Supervised by, Approved by,


Sub Contractor Site Supervisor CME Manager
PT. Smart Telecom PT. Smart Telecom
PT. Perissos Andalan Abadi

Name : Ariansyah Name : …………………… Name : ……………………


Title : Project Manager Title : ………………….. Title : …………………..
Date : ……………..…… Date : ……………..…… Date :……………………
Mechanical Electrical Works
Inspection Report
CME Regional

Inspection : Power Connection Date :

Site ID : NBTM_0079 Region : Sumbagut

Site Name : SUNGAI PANAS - BTS

1. KWH Pole Position : OK Not OK N/A

2. KWH Pole Foundation

Depth : OK Not OK N/A

Dimension,….… x…..…x……. mm : OK Not OK N/A

Concrete : OK Not OK N/A

3. KWH Pole Condition

Hot Dipped Galvanized : OK Not OK N/A

Dimension, Dia……… x L……… : OK Not OK N/A

Using pipe cup : OK Not OK N/A

4. KWH Panel

Approved Manufacture : ……………………………………………………………………

Panel Box Dimension : ………………..x………………….x………………….mm

Proper installed on pole : OK Not OK N/A

Wiring Diagram : OK Not OK N/A

Lock Operation/Key : OK Not OK N/A

KWH Meter Condition

(Subject to PLN Supply) : OK Not OK N/A

KWH Meter MCB Capacity……..A : Yes No N/A

MCB of OBL and Site Lamp : Yes No N/A

Arrester of OBL : Yes No N/A

Ground Connected to KWH Box : Yes No N/A

KWH Ground BC type …… mm2 : Yes No N/A

KWH Ground Flexible Pipe : Yes No N/A

Change Over Switch : OK Not OK N/A

Receptacle : OK Not OK N/A

5 Photo Cell

Manufacturer :

Current load capacity, ……….. A : Yes No N/A

Proper Installation : Yes No N/A

6 Grounding Measurement Value


Mechanical Electrical Works
Inspection Report
CME Regional

Inspection : Power Connection Date :

Site ID : NBTM_0079 Region : Sumbagut

Site Name : SUNGAI PANAS - BTS

< 1 Ohm : Yes No

7 Cable Power

NYFGBY / NYY 4 x 16 mm2 : Yes No N/A

Brand of cable: …………………. : Yes No N/A

Connected to COS : Yes No N/A

Laid -……m underground (if any) : Yes No N/A

8 Bolts, Nuts and Clamp

Hot Dipped Galvanize : Yes No N/A

Power cable protector on KWH pole, ………………………………………………

: Yes No N/A

9 Notes

Prepared by, Reviewed & Supervised by, Approved by,


Sub Contractor Site Supervisor CME Manager
PT. Perissos Andalan Abadi PT. Smart Telecom PT. Smart Telecom

Name : Ariansyah Name : …………………… Name : ……………………


Title : Project Manager Title : ………………….. Title : …………………..
Date : ……………..…… Date : ……………..…… Date :……………………