MCI-7-day-electronic-timer

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

http://waterheatertimer.org/pdf/Woods-timers-and-manuals.

html

Operating Instructions for Timer Press and hold button ‘PROG’, depress ‘HR +’ briefly and DISPLAY ON
OFF
TIMER

Programming release both buttons simultaneously to activate PROG HR +

MCI 7-Day Electronic Timer programming mode. The yellow timer indicator (3) will flash.

DAY à

Press button ‘DAY à’ to select desired day of week.


MIN +

2 1 4 ON

Press button ‘SET’ to activate time setting mode. OFF


HEATER
SET

1 Time of day / preset time display.


H P 2 Heater active indicator (green). Press button ‘HR +’ or ‘MIN +” to select heater start time. ON
OFF
DAY à

12:00
TIMER
3 Timer active indicator (yellow). If the dip switch setting is in the AM/PM mode, the red PM HR + MIN +

3 T 4 Clock AM/PM indicator (red).


5 Day of the week indicators (red). Press button ‘SET’ to end timer programming mode.
S M T W T F S 6 Function / setting buttons. If ‘SET’ button is not depressed within 15 seconds,
ON
OFF
HEATER

programming function will end automatically. SET

5
Manual To manually switch the heater on, press the ‘ON OFF
6 HEATER’ button. The green heater ‘active’ indicator (2) will
ON
OFF
Operation HEATER
SET

DISPLAY ON ON DAY à respond. Press button a second time to turn the heater off.
OFF OFF
HEATER TIMER
PROG SET HR + MIN + Timed Press the ‘ON OFF TIMER’ button to activate or deactivate ON
OFF
Operation the timed start of heater mode. Whenever the ‘ON OFF TIMER
HR +
TIMER’ button is pressed, the current timer setting will be
visible on the display for a few seconds. When the timer
General The 7-Day Electronic Timer provides full control of heater operation in mode is active, the yellow timer indicator (3) will respond.
either manual or timed modes. The heater will automatically switch on upon reaching the
The timer allows for 1 preset start time setting once within a 24 hour programmed start time.
period on any 1 day up to 7 days in advance.
Timer With the ignition off, and the heater is switched on manually or
The current time and weekday must be programmed. Duration automatically, it will stay on for a duration of 1 hour or until the ‘ON
OFF HEATER’ button is pressed.
Clock Press and hold button ‘PROG’, depress ‘MIN +’ briefly and DISPLAY DAY à With the ignition on (bus in operation), the heater will run and cycle
Programming release both buttons simultaneously to activate PROG MIN +
continuously until the ignition key is turned off.
programming mode. Day indicator (5) will flash.
Display The timer display will be visible whenever the ignition is on or any of
DAY à Stand By the timer function buttons (6) are pressed.
Press button ‘DAY à’ to select day of week. Mode If the ignition is off, the display will be visible for 30 seconds.
MIN +

ON

Press button ‘SET’ to activate time setting mode. OFF


HEATER
SET

ON

Press button ‘HR +’ to select correct hour. OFF


TIMER
HR +

DAY à
North American Headquarters
Press button ‘MIN +’ to select correct minute. 3333 John Conley Drive
MIN +
Lapeer, MI 48446
Press button ‘SET’ to end clock programming mode. ON
OFF
If ‘SET’ button is not depressed within 15 seconds, HEATER
SET

programming function will end automatically.


Technical Assistance: 1-800-667-8900
4/00 907103