SCHEDULER INFO: Normal mode

###############################################################

###############################################################
SCHEDULER INFO: Terminal mode
###############################################################

Entering configuration menus...


But the modem process is still in an active state
This can cause some unexpected behavior in the terminal

You can reset the station now to get full access to the menus, or
the modem menus will be disabled as long as the modem is active (could take some
minutes)

================================================================================
========
USER: \ MAIN MENU
================================================================================
========

(1) SYSTEM
(2) SENSORS
(3) MODEM

08/06/2023 10:52:15 >> Select...


08/06/2023 10:52:17 >> Chosen function: SENSORS

===================================================================================
=====
USER: \ MAIN MENU \ SENSORS
===================================================================================
=====

(B) BATTERY STATUS


(T) DO SENSOR TEST
(W) WIRELESS SYSTEM
(I) ACCEPT CONFIGURATION + DO RECORD
(P) PRINT LAST MEASURED DATA
(S) PRINT LIST OF SUPPORTED SENSORS
(E) PRINT ENCODED RECORDS
(C) DELETE SENSOR CONFIGURATION
(R) DELETE ALL RECORDS
(D) DELETE CONFIGURATION + RECORDS
(Y) SET ULTRASONIC ZERO WITH CURRENT HEIGHT
(Z) SET ULTRASONIC ZERO WITH 2 METERS
(0) SDI12
(1) Assign type of temperature sensors to inputs 1 to 3
(2) Select Leaf wetness or pressure switch for the LW input
(ESC) BACK

08/06/2023 10:52:18 >> Chosen function: DO SENSOR TEST

===================================================================================
=====
USER: \ MAIN MENU \ SENSORS \ DO SENSOR TEST
===================================================================================
=====
(0) MAIN + DUTY + HC2 SENSORS
(1) CHAIN AT INPUT 1
(2) CHAIN AT INPUT 2
(3) CHAIN AT INPUT 3
(4) CHAIN AT INPUT 4
(5) DEDICATED CHAIN
(6) EXTENDED INPUT A
(7) EXTENDED INPUT B
(8) WIRELESS CHAIN
(A) ALL SENSORS
(ESC) BACK

08/06/2023 10:52:19 >> Chosen function: ALL SENSORS

===================================================================================
=====
USER: \ MAIN MENU \ SENSORS \ DO SENSOR TEST \ ALL SENSORS
===================================================================================
=====

BATTR SOLPN WNDSP WSMAX PRECP


PCNT HC_SN AIRTM RELHM DEWPT VPD
DT SOLAR @SSN @SMST @SMST
@SMST @SMST @SMST @SMST @SMST
@SMST @SMST @SSDD @SSDD @SSDD
@SSDD @SSDD @SSDD @SSDD @SSDD
@SSDD @SOIT @SOIT @SOIT @SOIT
@SOIT @SOIT @SOIT @SOIT @SOIT
7 30 5 49 6 54
508 506 507 21 25 27
600 33809 19969 19969 19969
19969 19969 19969 19969 19969
19969 20228 20228 20228 20228
20228 20228 20228 20228 20228
17153 17153 17153 17153 17153
17153 17153 17153 17153
CH7/0 CH4/0 CH6/0 CH31/0 CH5/0
CH39/0 CH17/0 CH18/0 CH19/0 CH20/0
CH26/0 CH35/0 CH0/0 CH0/6 CH1/6
CH2/6 CH3/6 CH4/6 CH5/6 CH6/6
CH7/6 CH8/6 CH9/6 CH10/6 CH11/6
CH12/6 CH13/6 CH14/6 CH15/6 CH16/6
CH17/6 CH18/6 CH19/6 CH20/6 CH21/6
CH22/6 CH23/6 CH24/6 CH25/6 CH26/6
CH27/6
6.018 6.178 0.0 0.0 0.0 0
536884808 15.28 99.97 15.2 0.00 -
0.14 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.046 6.211 5.0 7.1 0.0 0
536884808 15.27 99.98 15.2 0.00 -
0.15 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.041 6.207 4.5 6.6 0.0 0
536884808 15.27 99.98 15.2 0.00 -
0.15 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.072 6.240 4.3 6.6 0.0 0
536884808 15.27 99.98 15.2 0.00 -
0.15 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.078 6.240 5.0 6.3 0.0 0
536884808 15.27 99.98 15.2 0.00 -
0.15 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.078 6.245 4.2 6.0 0.0 0
536884808 15.26 99.98 15.2 0.00 -
0.15 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.083 6.250 5.5 8.2 0.0 0
536884808 15.27 99.98 15.2 0.00 -
0.15 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.089 6.250 4.0 5.8 0.0 0
536884808 15.27 99.97 15.2 0.00 -
0.14 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.089 6.250 4.5 7.2 0.0 0
536884808 15.27 99.97 15.2 0.00 -
0.14 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.092 6.250 4.5 6.5 0.0 0
536884808 15.26 99.97 15.2 0.00 -
0.15 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.089 6.245 3.5 5.2 0.0 0
536884808 15.24 99.97 15.2 0.00 -
0.15 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.089 6.250 2.8 4.5 0.0 0
536884808 15.25 99.96 15.2 0.00 -
0.14 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.092 6.240 3.0 4.6 0.0 0
536884808 15.24 99.96 15.2 0.00 -
0.14 26 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.092 6.230 3.2 4.8 0.0 0
536884808 15.24 99.96 15.2 0.00 -
0.14 25 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.092 6.230 2.5 2.6 0.0 0
536884808 15.21 99.96 15.2 0.00 -
0.15 24 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.092 6.226 3.7 6.1 0.0 0
536884808 15.21 99.96 15.2 0.00 -
0.15 24 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.095 6.211 5.5 7.7 0.0 0
536884808 15.20 99.96 15.1 0.00 -
0.15 24 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.098 6.211 4.6 6.7 0.0 0
536884808 15.19 99.96 15.1 0.00 -
0.15 24 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.095 6.192 4.5 6.6 0.0 0
536884808 15.16 99.96 15.1 0.00 -
0.15 24 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.092 6.183 4.1 5.9 0.0 0
536884808 15.18 99.95 15.1 0.00 -
0.15 24 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.095 6.173 4.7 6.3 0.0 0
536884808 15.17 99.95 15.1 0.00 -
0.15 24 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.095 6.178 4.1 6.4 0.0 0
536884808 15.15 99.96 15.1 0.00 -
0.15 23 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.095 6.178 4.1 6.4 0.0 0
536884808 15.14 99.95 15.1 0.00 -
0.15 23 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.092 6.187 3.2 4.3 0.0 0
536884808 15.14 99.95 15.1 0.00 -
0.15 23 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.095 6.192 3.8 5.8 0.0 0
536884808 15.12 99.94 15.1 0.00 -
0.15 24 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.098 6.211 3.7 5.3 0.0 0
536884808 15.11 99.94 15.1 0.00 -
0.15 24 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.095 6.211 4.0 5.7 0.0 0
536884808 15.09 99.94 15.0 0.00 -
0.15 24 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.095 6.226 5.0 7.4 0.0 0
536884808 15.08 99.95 15.0 0.00 -
0.15 24 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
6.095 6.235 4.5 7.5 0.0 0
536884808 15.07 99.95 15.0 0.00 -
0.15 24 Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Sensor Error Sensor Error Unplugged
Unplugged Unplugged Sensor Error Sensor Error Sensor Error
Sensor Error Unplugged Unplugged Unplugged Unplugged
Unplugged Unplugged Unplugged Unplugged Unplugged

===================================================================================
=====
USER: \ MAIN MENU \ SENSORS \ DO SENSOR TEST
===================================================================================
=====

(0) MAIN + DUTY + HC2 SENSORS


(1) CHAIN AT INPUT 1
(2) CHAIN AT INPUT 2
(3) CHAIN AT INPUT 3
(4) CHAIN AT INPUT 4
(5) DEDICATED CHAIN
(6) EXTENDED INPUT A
(7) EXTENDED INPUT B
(8) WIRELESS CHAIN
(A) ALL SENSORS
(ESC) BACK

08/06/2023 10:55:29 >> MOVE TO PREVIOUS MENU

===================================================================================
=====
USER: \ MAIN MENU \ SENSORS
===================================================================================
=====

(B) BATTERY STATUS


(T) DO SENSOR TEST
(W) WIRELESS SYSTEM
(I) ACCEPT CONFIGURATION + DO RECORD
(P) PRINT LAST MEASURED DATA
(S) PRINT LIST OF SUPPORTED SENSORS
(E) PRINT ENCODED RECORDS
(C) DELETE SENSOR CONFIGURATION
(R) DELETE ALL RECORDS
(D) DELETE CONFIGURATION + RECORDS
(Y) SET ULTRASONIC ZERO WITH CURRENT HEIGHT
(Z) SET ULTRASONIC ZERO WITH 2 METERS
(0) SDI12
(1) Assign type of temperature sensors to inputs 1 to 3
(2) Select Leaf wetness or pressure switch for the LW input
(ESC) BACK

08/06/2023 10:55:31 >> Chosen function: DELETE SENSOR CONFIGURATION

===================================================================================
=====
USER: \ MAIN MENU \ SENSORS \ DELETE SENSOR CONFIGURATION
===================================================================================
=====

Do You want to clear the sensor configuration permanently (Y/N)? > YES

Database operation accepted


Operation takes few minutes
PLEASE WAIT until yellow led turns off

===================================================================================
=====
USER: \ MAIN MENU \ SENSORS
===================================================================================
=====

(B) BATTERY STATUS


(T) DO SENSOR TEST
(W) WIRELESS SYSTEM
(I) ACCEPT CONFIGURATION + DO RECORD
(P) PRINT LAST MEASURED DATA
(S) PRINT LIST OF SUPPORTED SENSORS
(E) PRINT ENCODED RECORDS
(C) DELETE SENSOR CONFIGURATION
(R) DELETE ALL RECORDS
(D) DELETE CONFIGURATION + RECORDS
(Y) SET ULTRASONIC ZERO WITH CURRENT HEIGHT
(Z) SET ULTRASONIC ZERO WITH 2 METERS
(0) SDI12
(1) Assign type of temperature sensors to inputs 1 to 3
(2) Select Leaf wetness or pressure switch for the LW input
(ESC) BACK

08/06/2023 10:55:40 >> Chosen function: DO SENSOR TEST

===================================================================================
=====
USER: \ MAIN MENU \ SENSORS \ DO SENSOR TEST
===================================================================================
=====

(0) MAIN + DUTY + HC2 SENSORS


(1) CHAIN AT INPUT 1
(2) CHAIN AT INPUT 2
(3) CHAIN AT INPUT 3
(4) CHAIN AT INPUT 4
(5) DEDICATED CHAIN
(6) EXTENDED INPUT A
(7) EXTENDED INPUT B
(8) WIRELESS CHAIN
(A) ALL SENSORS
(ESC) BACK

08/06/2023 10:55:41 >> Chosen function: ALL SENSORS

===================================================================================
=====
USER: \ MAIN MENU \ SENSORS \ DO SENSOR TEST \ ALL SENSORS
===================================================================================
=====

SOLPN BATTR WNDSP WSMAX PRECP


PCNT HC_SN AIRTM RELHM DEWPT VPD
DT SOLAR
30 7 5 49 6 54
508 506 507 21 25 27
600
CH4/0 CH7/0 CH6/0 CH31/0 CH5/0
CH39/0 CH17/0 CH18/0 CH19/0 CH20/0
CH26/0 CH35/0 CH0/0
6.259 6.098 3.7 5.6 0.0 0
536884808 15.05 99.95 15.0 0.00 -
0.15 26
6.254 6.098 4.1 6.3 0.0 0
536884808 15.05 99.94 15.0 0.00 -
0.15 26
6.264 6.101 2.7 3.7 0.0 0
536884808 15.06 99.94 15.0 0.00 -
0.15 26
6.269 6.098 3.1 4.7 0.0 0
536884808 15.03 99.94 15.0 0.00 -
0.15 26
6.264 6.098 3.8 5.6 0.0 0
536884808 15.02 99.94 15.0 0.00 -
0.15 26
6.269 6.098 3.7 5.7 0.0 0
536884808 15.02 99.94 15.0 0.00 -
0.15 26
6.269 6.098 3.0 4.2 0.0 0
536884808 15.02 99.94 15.0 0.00 -
0.15 28
6.269 6.101 3.7 4.6 0.0 0
536884808 15.01 99.94 15.0 0.00 -
0.15 28
6.283 6.098 3.5 4.8 0.0 0
536884808 15.00 99.94 14.9 0.00 -
0.15 28
6.283 6.095 3.8 5.8 0.0 0
536884808 15.00 99.94 14.9 0.00 -
0.15 28
SOLPN BATTR WNDSP WSMAX PRECP
PCNT HC_SN AIRTM RELHM DEWPT VPD
DT SOLAR PAVG PMIN PMAX
30 7 5 49 6 54
508 506 507 21 25 27
600 55 57 56
CH4/0 CH7/0 CH6/0 CH31/0 CH5/0
CH39/0 CH17/0 CH18/0 CH19/0 CH20/0
CH26/0 CH35/0 CH0/0 CH40/0 CH41/0
CH42/0
6.288 6.098 2.8 5.3 1.0 5
536884808 14.99 99.94 14.9 0.00 -
0.15 28 246 163 397
6.278 6.095 3.6 4.9 1.0 5
536884808 14.98 99.94 14.9 0.00 -
0.15 28 Unplugged Unplugged Unplugged
6.283 6.095 3.6 5.7 1.0 5
536884808 14.99 99.94 14.9 0.00 -
0.15 28 Unplugged Unplugged Unplugged

===================================================================================
=====
USER: \ MAIN MENU \ SENSORS \ DO SENSOR TEST
===================================================================================
=====

(0) MAIN + DUTY + HC2 SENSORS


(1) CHAIN AT INPUT 1
(2) CHAIN AT INPUT 2
(3) CHAIN AT INPUT 3
(4) CHAIN AT INPUT 4
(5) DEDICATED CHAIN
(6) EXTENDED INPUT A
(7) EXTENDED INPUT B
(8) WIRELESS CHAIN
(A) ALL SENSORS
(ESC) BACK

08/06/2023 10:57:05 >> MOVE TO PREVIOUS MENU

===================================================================================
=====
USER: \ MAIN MENU \ SENSORS
===================================================================================
=====
(B) BATTERY STATUS
(T) DO SENSOR TEST
(W) WIRELESS SYSTEM
(I) ACCEPT CONFIGURATION + DO RECORD
(P) PRINT LAST MEASURED DATA
(S) PRINT LIST OF SUPPORTED SENSORS
(E) PRINT ENCODED RECORDS
(C) DELETE SENSOR CONFIGURATION
(R) DELETE ALL RECORDS
(D) DELETE CONFIGURATION + RECORDS
(Y) SET ULTRASONIC ZERO WITH CURRENT HEIGHT
(Z) SET ULTRASONIC ZERO WITH 2 METERS
(0) SDI12
(1) Assign type of temperature sensors to inputs 1 to 3
(2) Select Leaf wetness or pressure switch for the LW input
(ESC) BACK

08/06/2023 10:57:05 >> MOVE TO PREVIOUS MENU

===================================================================================
=====
USER: \ MAIN MENU
===================================================================================
=====

(1) SYSTEM
(2) SENSORS
(3) MODEM

08/06/2023 10:57:08 >> Chosen function: MODEM

===================================================================================
=====
USER: \ MAIN MENU \ MODEM
===================================================================================
=====

(1) MODEM SETTINGS


(3) SEND STATION DATA
(4) GET GPS
(5) GET CONF SMS
(6) Download FW
(7) Download APN list
(ESC) BACK

08/06/2023 10:57:09 >> Chosen function: SEND STATION DATA

===================================================================================
=====
USER: \ MAIN MENU \ MODEM \ SEND STATION DATA
===================================================================================
=====

>
> Starting modem process
>
>
>> Turning modem on
>
+WDSI: 0

+SIM: 1
>
>> Reading modem's info
>
AT+KGSN=3
+KGSN: Q4916203290710

OK

+KSUP: 0
AT+KGSN=0
+KGSN: 014711001323449

OK
AT+CGMM
HL7688

OK
AT+CGMI
Sierra Wireless

OK
ATI3
RHL7688.A.2.15.1.0.151600.201809181425.x7160_1

OK

Manufacturer of modem: Sierra Wireless


Type of modem: HL7688
Modem firmware version: RHL7688.A.2.15.1.0.151600.201809181425.x7160_1
IMEI: 014711001323449
Serial number: Q4916203290710

Modem Baudrate: 115200


>
>> Reading SIM's info
>
> Waiting for complete initialization of the modem (+PBREADY)

+PBREADY
> Waiting for complete initialization of the modem (7 seconds)
> OK
AT+CIMI
901430002221726

OK
AT+CCID
+CCID: 89883030000063898644

OK
AT+CPIN?
+CPIN: READY

OK
AT+CNUM
OK
SIM's MCC: 901
SIM's MNC: 43
SIM's CCID: 89883030000063898644
SIM's CIMI: 901430002221726
SIM's PIN: READY
>
>> Basic configuration of the modem
>
ATE1
OK
ATE1
OK
ATE1
OK
ATZ
OK
AT+KSLEEP=2
OK
AT&D0
OK
AT&K3
OK
AT+CPMS="ME","ME","ME"
+CPMS: 0,32,0,32,0,32

OK
AT+CMGF=1
OK
AT+CMEE=1
OK
AT+KAAT=1
+CME ERROR: 100
AT+WMANTSEL?
+WMANTSEL: 00

OK
AT+CGREG=1
OK
AT+CNMI=2,1,0,0,0
OK
AT+COPS=3,2
OK
AT+COPS?
+COPS: 0

OK
AT+WDSI=1023
OK
AT&W
OK
>
>> Starting bearer and testing APN
>
AT+CGDCONT=1,"IPV4V6","em"
OK
AT+CFUN=1,1
OK
> Waiting for complete initialization of the modem (+PBREADY)
+CGREG: 0

+CGREG: 2

+WDSI: 0

+CGREG: 5

+PBREADY
> Waiting for complete initialization of the modem (7 seconds)
> OK

+SIM: 1

+KSUP: 0
AT+WDSS=1,0
OK
AT+CGACT?
+CGACT: 1,1

OK
AT+CGACT=0,1
+CGREG: 0

OK
AT+CGDCONT=1,"IPV4V6","em"
OK
AT+KCNXCFG=1,"GPRS","em","",""
OK
> Waiting for registration in the network (+CGREG: 1 or +CGREG: 5)

+CGREG: 5
AT+CSQ
+CSQ: 17,3

OK
AT+COPS?
+COPS: 0,2,"73001",7

OK
AT+KBND?
+KBND: 00000800

OK
AT+WDSS?
+WDSS: 0,"em",,1
+WDSS: 1,0

OK
AT+KCNXTIMER=1,30,3
OK
AT+KCNXUP=1
OK

+KCNX_IND: 1,4,1

+KCNX_IND: 1,1,0
AT+CGDCONT?
+CGDCONT: 1,"IP","em","100.91.200.62",0,0,0,0,0,0
OK
AT+CGPADDR=1
+CGPADDR: 1,"100.91.200.62"

OK
>
>> Connecting to PI server
>
>
>>> Calculating message size
>
AT+KTCPCFG?
OK
AT+KTCPCFG=1,0,"metos.at","80"
+KTCPCFG: 1

OK
AT+KTCPSTART=1
+KTCP_IND: 1,1

CONNECT
>
>> Making request to server
>
POST /pikernel_dev/metos_upload_xml33.php?sernum=0020F7F2&r=1&ver=2 HTTP/1.0
Host: metos.at
Accept: */*
User-Agent: Imetos-3.3
Cache-Control: no-cache
Connection: Close
Content-Length: 1601
Content-type: multipart/form-data; boundary=----------------------------
1234567890123456789012

------------------------------1234567890123456789012
Content-Disposition: form-data; name='metos_weather'; filename='0020F7F2.xml'
Content-Type: application/octet-stream

<?xml version='1.0' standalone='yes'?>


<station_xml>
<station_info
time='1686221897'
fw='08.602.20220207'
programmed='2022.06.09 08:25'
apntbl='3'
ser_num='0020F7F2'
uid='24F3190361BEF6A4'
name='iMetos 3.3'
senstbl='0'
dev_id='7'
descr='iMetos 3.3'
hw='29-0347'
/>
<ext1_board type='disconnected'/>
<scheduler
rain_int='0'
wl_int='0'
fix_trans_int='30'
xminupl_int='0;0'
data_sched='16777215; 16777215; 16777215; 16777215; 16777215; 16777215; 16777215'
meas_int='0,5,15; 1,5,15; 2,5,15; 3,5,15; 4,5,15; 5,5,15; 6,5,15; 7,5,15; 8,5,15'
wl_mon=''
warning_sensors=''
/>
<telephone
numbers=''
emg_num=''
max_warn='30'
max_num='30'
/>
<gps_info
status='NotAvailable'
/>
<networking
bearer_type='LTE'
band='0x00000800'
mcc_current='730'
mnc_current='01'
mcc_sim='901'
mnc_sim='43'
sim_id='89883030000063898644'
apn_country='Chile'
apn='em'
user=''
passw=''
roaming='1'
rssi_pct='54'
/>
<modem
brand='Sierra Wireless'
type='HL7688'
fwversion='RHL7688.A.2.15.1.0.151600.201809181425.x7160_1'
imei='014711001323449'
sn='Q4916203290710'
/>
<task_info
Meas='RUNNING'
Scheduler_Handler='RUNNING'
/>
<database
start='1679662522'
end='1684419352'
records='91'
memused='18696'
memsize='6488064'
/>
<!--Debug
Format:
<IM-DEBUG-LOG val="0;<name>" />
<name>:
SDI12
APBOARD
-->
<first_upload />
</station_xml>

------------------------------1234567890123456789012--
>
>> Downloading file from server
>
HTTP/1.1 200 OK
Server: nginx/1.18.0
Date: Thu, 08 Jun 2023 18:48:10 GMT
Content-Type: text/html; charset=UTF-8
Connection: close

---->> INFO <<----


IM-Request-Type: 1
IM-Checksum: 57578
IM-Hash: 0
IM-Content-Length: 784

---->> DATA <<----


<station_config>
<IM-RTC-TIME val="1686235690" />
<IM-STATION-NAME val="iMetos 3.3" />
<IM-APNTABLE val="3" />
<IM-SENSTABLE val="0" />
<IM-MEAS-INT val0='0;5;15' val1='1;5;15' val2='2;5;15' val3='3;5;15' val4='4;5;15'
val5='5;5;15' val6='6;5;15' val7='7;5;15' val8='8;5;15' />
<IM-MODE val="0" />
<IM-FIXED-TRANSF-INT val="30" />
<IM-RAIN-INT val="0"/>
<IM-EMG-SMS />
<IM-SMS-WARN-GSM />
<IM-SMS-WARN-VAL />
<IM-DATA-SCHED val='16777215;16777215;16777215;16777215;16777215;16777215;16777215'
/>
<IM-GPS-EN val="1"/>
<IM-SENSOR-CODE val1="4;4" val2="5;40" />
<IM-DB-DATE val="1679662522;1685040490" />
<IM-DB-UPLOAD val="1" />
<IM-WEB-CONN val="Close" />
<IM-JOBID val="upload_job_0020F7F2_1686250090.7124" />
<IM-RESPONSE-TIME val="0.0052" />
</station_config>
Updated station name
Updated warning values
Updated emergency number
Updated warning numbers
Updated rain interval
Updated data transmission schedule
Updated station mode
Updated scheduler settings
Updated fixed transfer interval
Updated server database dates
Updated sensor codes
Updated GPS Config: enabled
Debug disabled
Updated RTC timestamp

NO CARRIER
> No worries, this is not really an error

+KTCP_DATA: 1,1039
+KTCP_NOTIF: 1,4
>
>> Stopping bearer
>
AT+KCNXDOWN=1,1
OK
>
>> Waiting new SMS, could take 5 minutes, press ESC to cancel
>

+KCNX_IND: 1,0,0
>
>> Checking if there is an update for the modem
>
AT+CGACT=0,1
+CGREG: 0

OK
AT+WDSS=0,"em","","",1
OK
AT+WDSC=3,0
OK
AT+WDSC=4,0
OK
> Waiting for registration in the network (+CGREG: 1 or +CGREG: 5)

+CGREG: 5
AT+WDSS=1,1
OK

+WDSI: 4

+WDSI: 7
ATI3
RHL7688.A.2.15.1.0.151600.201809181425.x7160_1

OK
AT+WDSS=1,0
OK
>
>> ---- INFO: Success. ----
Success
>
>
>> Turning modem off
>
AT+CFUN=4
+CGREG: 0

OK
AT+CPWROFF
OK

===================================================================================
=====
USER: \ MAIN MENU \ MODEM
===================================================================================
=====
(1) MODEM SETTINGS
(3) SEND STATION DATA
(4) GET GPS
(5) GET CONF SMS
(6) Download FW
(7) Download APN list
(ESC) BACK

08/06/2023 14:49:01 >> Select...


###############################################################
SCHEDULER INFO: Normal mode
###############################################################
Next comm: 08/06/2023 15:00:00

0
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
1>

Next meas: > 08/06/2023 14:50:00Starting modem process

>
Next log: >
08/06/2023 15:00:00>>
Turning modem on
2>

Next meas: 08/06/2023 14:50:00


Next log: 08/06/2023 15:00:00
3
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
4
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
5
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
6
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
7
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
8
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00

###############################################################
MEASUREMENT PROCESS STARTED
08/06/2023 14:49:02
---------------------------------------------------------------
----------------- MEASUREMENT PROCESS RUNNING -----------------
AP Board ->
Main sensors:

Solar -> 6283 mV

Battery -> 6064 mV


Data collected

HygroClip A ->

HygroClip B ->
{F00rdd 001; 99.94;%rh;000; ; 14.97;°C;000; ;nc;---.- ;°C;000; ;020;V1.2-
1;0020451711;HC2A ;000;?

Digital IO 1 ->
Duty->Name: SOLAR, CH: 0, Val: 40

Digital IO 2 ->

Digital IO 3 ->

+WDSI: 0

Digital IO 4 ->

Dedicated PI Bus ->

Extension board A ->

Extension board B ->

------------------- DATABASE POST-PROCESSING ------------------


Updated sensor warning settings in RAM
Sensor Storage Finish -> No sensor warnings were generated
Record Stored for mask: 0x1 at address: 18696

---------------------------------------------------------------
MEASUREMENT PROCESS FINISHED
###############################################################
Next comm: 08/06/2023 15:00:00

0
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
1
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
2
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
3
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
4
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
5
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
6
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
7
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00
8
Next meas: 08/06/2023 14:50:00
Next log: 08/06/2023 15:00:00

###############################################################
SCHEDULER INFO: Battery under 6.3 V
###############################################################

+SIM: 1
>
>> Reading modem's info
>
AT+KGSN=3
+KGSN: Q4916203290710

OK

+KSUP: 0
AT+KGSN=0
+KGSN: 014711001323449

OK
AT+CGMM
HL7688

OK
AT+CGMI
Sierra Wireless

OK
ATI3
RHL7688.A.2.15.1.0.151600.201809181425.x7160_1

OK

Manufacturer of modem: Sierra Wireless


Type of modem: HL7688
Modem firmware version: RHL7688.A.2.15.1.0.151600.201809181425.x7160_1
IMEI: 014711001323449
Serial number: Q4916203290710

Modem Baudrate: 115200


>
>> Reading SIM's info
>
> Waiting for complete initialization of the modem (+PBREADY)

+PBREADY
> Waiting for complete initialization of the modem (7 seconds)
> OK
AT+CIMI
901430002221726

OK
AT+CCID
+CCID: 89883030000063898644
OK
AT+CPIN?
+CPIN: READY

OK
AT+CNUM
OK
SIM's MCC: 901
SIM's MNC: 43
SIM's CCID: 89883030000063898644
SIM's CIMI: 901430002221726
SIM's PIN: READY
>
>> Modem is already configured
>
AT+CFUN?
+CFUN: 4,0

OK
AT+CFUN=1
+CGREG: 2

OK
>
>> GPS started, max 10 minutes until finishing it
>
>
>> Starting bearer and testing APN
>

+CGREG: 5
AT+CGDCONT=1,"IPV4V6","em"
OK
AT+CFUN=1,1
OK
> Waiting for complete initialization of the modem (+PBREADY)

+CGREG: 0

+CGREG: 2

+WDSI: 0

+CGREG: 5

+PBREADY
> Waiting for complete initialization of the modem (7 seconds)
0
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
1
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
2
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
3
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
4
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
5
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
6
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
7
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
8
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00

###############################################################
MEASUREMENT PROCESS STARTED
08/06/2023 14:50:01
---------------------------------------------------------------
----------------- MEASUREMENT PROCESS RUNNING -----------------
AP Board ->
Main sensors:

Solar -> 6254 mV

Battery -> 6044 mV

Data collected

HygroClip A ->

HygroClip B ->
> OK

+SIM: 1

+KSUP: 0
AT+WDSS=1,0
OK
AT+CGACT?
+CGACT: 1,1

OK
{F00rdd 001; 99.93;%rh;000; ; 15.00;°C;000; ;nc;---.- ;°C;000; ;020;V1.2-
1;0020451711;HC2A ;000;/

Digital IO 1 ->

+CGREG: 0

OK
Duty->Name: SOLAR, CH: 0, Val: 42

Digital IO 2 ->
AT+CGDCONT=1,"IPV4V6","em"
OK
Digital IO 3 ->

Digital IO 4 ->
AT+KCNXCFG=1,"GPRS","em","",""
OK

Dedicated PI Bus ->

Extension board A ->

Extension board B ->

------------------- DATABASE POST-PROCESSING ------------------


Sensor Storage Finish -> No sensor warnings were generated
---------------------------------------------------------------
MEASUREMENT PROCESS FINISHED
###############################################################
> Waiting for registration in the network (+CGREG: 1 or +CGREG: 5)

+CGREG: 5
AT+CSQ
+CSQ: 16,2

OK
AT+COPS?
+COPS: 0,2,"73001",7

OK
AT+KBND?
+KBND: 00000800

OK
AT+WDSS?
+WDSS: 0,"em",,1
+WDSS: 1,0

OK
AT+KCNXTIMER=1,30,3
OK
Next comm: 08/06/2023 15:00:00

0
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
1
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
2
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
3
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
4
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
5
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
6
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
7
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00
8
Next meas: 08/06/2023 14:55:00
Next log: 08/06/2023 15:00:00

###############################################################
SCHEDULER INFO: Battery under 6.3 V
###############################################################
AT+KCNXUP=1
OK

+KCNX_IND: 1,4,1

+KCNX_IND: 1,1,0
AT+CGDCONT?
+CGDCONT: 1,"IP","em","100.91.200.62",0,0,0,0,0,0

OK
AT+CGPADDR=1
+CGPADDR: 1,"100.91.200.62"

OK
>
>> Connecting to PI server
>
>
>>> Calculating message size
>
AT+KTCPCFG?
OK
AT+KTCPCFG=1,0,"metos.at","80"
+KTCPCFG: 1

OK
AT+KTCPSTART=1
+KTCP_IND: 1,1

CONNECT
>
>> Making request to server
>
POST /pikernel_dev/metos_upload_xml33.php?sernum=0020F7F2&r=1&ver=2 HTTP/1.0
Host: metos.at
Accept: */*
User-Agent: Imetos-3.3
Cache-Control: no-cache
Connection: Close
Content-Length: 4592
Content-type: multipart/form-data; boundary=----------------------------
1234567890123456789012

------------------------------1234567890123456789012
Content-Disposition: form-data; name='metos_weather'; filename='0020F7F2.xml'
Content-Type: application/octet-stream

<?xml version='1.0' standalone='yes'?>


<station_xml>
<station_info
time='1686235811'
fw='08.602.20220207'
programmed='2022.06.09 08:25'
apntbl='3'
ser_num='0020F7F2'
uid='24F3190361BEF6A4'
name='iMetos 3.3'
senstbl='0'
dev_id='7'
descr='iMetos 3.3'
hw='29-0347'
/>
<ext1_board type='disconnected'/>
<scheduler
rain_int='0'
wl_int='0'
fix_trans_int='30'
xminupl_int='0;0'
data_sched='16777215; 16777215; 16777215; 16777215; 16777215; 16777215; 16777215'
meas_int='0,5,15; 1,5,15; 2,5,15; 3,5,15; 4,5,15; 5,5,15; 6,5,15; 7,5,15; 8,5,15'
wl_mon=''
warning_sensors=''
/>
<telephone
numbers=''
emg_num=''
max_warn='30'
max_num='30'
/>
<gps_info
status='NotAvailable'
/>
<networking
bearer_type='LTE'
band='0x00000800'
mcc_current='730'
mnc_current='01'
mcc_sim='901'
mnc_sim='43'
sim_id='89883030000063898644'
apn_country='Chile'
apn='em'
user=''
passw=''
roaming='1'
rssi_pct='51'
/>
<modem
brand='Sierra Wireless'
type='HL7688'
fwversion='RHL7688.A.2.15.1.0.151600.201809181425.x7160_1'
imei='014711001323449'
sn='Q4916203290710'
/>
<task_info
Meas='RUNNING'
Scheduler_Handler='RUNNING'
/>
<database
start='1679662522'
end='1686235742'
records='92'
memused='18888'
memsize='6488064'
/>
<!--Debug
Format:
<IM-DEBUG-LOG val="0;<name>" />
<name>:
SDI12
APBOARD
-->
<events>
<event code='20' info='1125' date='1685098024' />
<event code='1121' info='0' date='1685098045' />
<event code='204' info='4' date='1685030358' />
<event code='204' info='7' date='1685030370' />
<event code='204' info='8' date='1685030371' />
<event code='204' info='9' date='1685030396' />
<event code='204' info='10' date='1685030402' />
<event code='204' info='12' date='1685030487' />
<event code='204' info='13' date='1685030492' />
<event code='204' info='14' date='1685030492' />
<event code='204' info='11' date='1685098030' />
<event code='204' info='17' date='1685098036' />
<event code='204' info='15' date='1685098036' />
<event code='204' info='2' date='1685098045' />
<event code='204' info='5' date='1685098045' />
<event code='204' info='0' date='1685098062' />
<event code='14' info='64' date='1685098065' />
<event code='10' info='1' date='1685098067' />
<event code='10' info='1' date='1685098069' />
<event code='10' info='1' date='1685098071' />
<event code='20' info='18713' date='1686221369' />
<event code='1121' info='0' date='1686221383' />
<event code='204' info='4' date='1685098080' />
<event code='204' info='7' date='1685098210' />
<event code='204' info='8' date='1685098210' />
<event code='204' info='9' date='1685098223' />
<event code='204' info='10' date='1685098240' />
<event code='204' info='12' date='1685098263' />
<event code='204' info='13' date='1685098265' />
<event code='204' info='14' date='1685098265' />
<event code='204' info='12' date='1685098276' />
<event code='204' info='10' date='1685098524' />
<event code='204' info='12' date='1685098548' />
<event code='204' info='13' date='1685098549' />
<event code='204' info='14' date='1685098550' />
<event code='204' info='11' date='1686221374' />
<event code='204' info='17' date='1686221379' />
<event code='204' info='15' date='1686221379' />
<event code='204' info='2' date='1686221383' />
<event code='204' info='5' date='1686221383' />
<event code='204' info='0' date='1686221397' />
<event code='14' info='64' date='1686221400' />
<event code='10' info='1' date='1686221402' />
<event code='210' info='0' date='1686221407' />
<event code='204' info='4' date='1686221407' />
<event code='204' info='7' date='1686221420' />
<event code='204' info='8' date='1686221420' />
<event code='204' info='9' date='1686221445' />
<event code='204' info='18' date='1686221451' />
<event code='204' info='16' date='1686221457' />
<event code='12' info='12' date='1686221459' />
<event code='2001' info='0' date='1686221747' />
<event code='20' info='229' date='1686235690' />
<event code='1121' info='0' date='1686235713' />
<event code='24' info='6300' date='1686235749' />
</events>
<weather_bin>
paX/
AVsAAADcSAAAyEkAAF7qgWQQAKQAnaADax4ABAACCIsYBwAHAAIIsBcFAAYAAgUhACkAMQAfAAIEPwAGAAU
AggAKADYAJwCLAAUAAAD8AREACwhINgAg+gESAAYH3QXZBeIF+wETAAIHCicKJwsnFQAUACYDlQCVABkAGg
ACAwAAAAAbACMABgfx//H/8f9YAgAAAgEcADcAKAALB/
YAAAD2AAAA9gAAADkAKQALAqMAAAA4ACoACwSNAQAA</weather_bin>
</station_xml>

------------------------------1234567890123456789012--
>
>> Downloading file from server
>
HTTP/1.1 200 OK
Server: nginx/1.18.0
Date: Thu, 08 Jun 2023 18:50:13 GMT
Content-Type: text/html; charset=UTF-8
Connection: close

no file ...
NO CARRIER
> No worries, this is not really an error

+KTCP_DATA: 1,148

+KTCP_NOTIF: 1,4
>
>> Connecting to PI server
>
>
>>> Calculating message size
>
AT+KTCPCFG?
+KTCPCFG: 1,0,1,0,,"metos.at",80,1944,0,0,0,0

OK
AT+KTCPSTART=1
+KTCP_NOTIF: 1,5

AT+CEER
+CEER: "No report available"

OK
AT+KCNXDOWN=1,1
OK
>
>> Starting bearer and testing APN
>

+KCNX_IND: 1,0,0
AT+CGDCONT=1,"IPV4V6","em"
OK
AT+CFUN=1,1
OK
> Waiting for complete initialization of the modem (+PBREADY)

+CGREG: 0

+CGREG: 2

+WDSI: 0

+CGREG: 5

+PBREADY
> Waiting for complete initialization of the modem (7 seconds)
> OK

+SIM: 1

+KSUP: 0
AT+WDSS=1,0
OK
AT+CGACT?
+CGACT: 1,1

OK
AT+CGACT=0,1
+CGREG: 0

OK
AT+CGDCONT=1,"IPV4V6","em"
OK
AT+KCNXCFG=1,"GPRS","em","",""
OK
> Waiting for registration in the network (+CGREG: 1 or +CGREG: 5)

+CGREG: 5
AT+CSQ
+CSQ: 16,5

OK
AT+COPS?
+COPS: 0,2,"73001",7

OK
AT+KBND?
+KBND: 00000800

OK
AT+WDSS?
+WDSS: 0,"em",,1
+WDSS: 1,0

OK
AT+KCNXTIMER=1,30,3
OK
AT+KCNXUP=1
OK

+KCNX_IND: 1,4,1

+KCNX_IND: 1,1,0
AT+CGDCONT?
+CGDCONT: 1,"IP","em","100.91.200.62",0,0,0,0,0,0

OK
AT+CGPADDR=1
+CGPADDR: 1,"100.91.200.62"

OK
>
>> Connecting to PI server
>
>
>>> Calculating message size
>
AT+KTCPCFG?
OK
AT+KTCPCFG=1,0,"metos.at","80"
+KTCPCFG: 1

OK
AT+KTCPSTART=1
+KTCP_IND: 1,1

CONNECT
>
>> Making request to server
>
POST /pikernel_dev/metos_upload_xml33.php?sernum=0020F7F2&r=1&ver=2 HTTP/1.0
Host: metos.at
Accept: */*
User-Agent: Imetos-3.3
Cache-Control: no-cache
Connection: Close
Content-Length: 4615
Content-type: multipart/form-data; boundary=----------------------------
1234567890123456789012

------------------------------1234567890123456789012
Content-Disposition: form-data; name='metos_weather'; filename='0020F7F2.xml'
Content-Type: application/octet-stream

<?xml version='1.0' standalone='yes'?>


<station_xml>
<station_info
time='1686236097'
fw='08.602.20220207'
programmed='2022.06.09 08:25'
apntbl='3'
ser_num='0020F7F2'
uid='24F3190361BEF6A4'
name='iMetos 3.3'
senstbl='0'
dev_id='7'
descr='iMetos 3.3'
hw='29-0347'
/>
<ext1_board type='disconnected'/>
<scheduler
rain_int='0'
wl_int='0'
fix_trans_int='30'
xminupl_int='0;0'
data_sched='16777215; 16777215; 16777215; 16777215; 16777215; 16777215; 16777215'
meas_int='0,5,15; 1,5,15; 2,5,15; 3,5,15; 4,5,15; 5,5,15; 6,5,15; 7,5,15; 8,5,15'
wl_mon=''
warning_sensors=''
/>
<telephone
numbers=''
emg_num=''
max_warn='30'
max_num='30'
/>
<gps_info
status='NotAvailable'
/>
<networking
bearer_type='LTE'
band='0x00000800'
mcc_current='730'
mnc_current='01'
mcc_sim='901'
mnc_sim='43'
sim_id='89883030000063898644'
apn_country='Chile'
apn='em'
user=''
passw=''
roaming='1'
rssi_pct='51'
/>
<modem
brand='Sierra Wireless'
type='HL7688'
fwversion='RHL7688.A.2.15.1.0.151600.201809181425.x7160_1'
imei='014711001323449'
sn='Q4916203290710'
/>
<task_info
Meas='RUNNING'
Scheduler_Handler='RUNNING'
/>
<database
start='1679662522'
end='1686235742'
records='92'
memused='18888'
memsize='6488064'
/>
<!--Debug
Format:
<IM-DEBUG-LOG val="0;<name>" />
<name>:
SDI12
APBOARD
-->
<events>
<event code='20' info='1125' date='1685098024' />
<event code='1121' info='0' date='1685098045' />
<event code='204' info='4' date='1685030358' />
<event code='204' info='7' date='1685030370' />
<event code='204' info='8' date='1685030371' />
<event code='204' info='9' date='1685030396' />
<event code='204' info='10' date='1685030402' />
<event code='204' info='12' date='1685030487' />
<event code='204' info='13' date='1685030492' />
<event code='204' info='14' date='1685030492' />
<event code='204' info='11' date='1685098030' />
<event code='204' info='17' date='1685098036' />
<event code='204' info='15' date='1685098036' />
<event code='204' info='2' date='1685098045' />
<event code='204' info='5' date='1685098045' />
<event code='204' info='0' date='1685098062' />
<event code='14' info='64' date='1685098065' />
<event code='10' info='1' date='1685098067' />
<event code='10' info='1' date='1685098069' />
<event code='10' info='1' date='1685098071' />
<event code='20' info='18713' date='1686221369' />
<event code='1121' info='0' date='1686221383' />
<event code='204' info='4' date='1685098080' />
<event code='204' info='7' date='1685098210' />
<event code='204' info='8' date='1685098210' />
<event code='204' info='9' date='1685098223' />
<event code='204' info='10' date='1685098240' />
<event code='204' info='12' date='1685098263' />
<event code='204' info='13' date='1685098265' />
<event code='204' info='14' date='1685098265' />
<event code='204' info='12' date='1685098276' />
<event code='204' info='10' date='1685098524' />
<event code='204' info='12' date='1685098548' />
<event code='204' info='13' date='1685098549' />
<event code='204' info='14' date='1685098550' />
<event code='204' info='11' date='1686221374' />
<event code='204' info='17' date='1686221379' />
<event code='204' info='15' date='1686221379' />
<event code='204' info='2' date='1686221383' />
<event code='204' info='5' date='1686221383' />
<event code='204' info='0' date='1686221397' />
<event code='14' info='64' date='1686221400' />
<event code='10' info='1' date='1686221402' />
<event code='210' info='0' date='1686221407' />
<event code='204' info='4' date='1686221407' />
<event code='204' info='7' date='1686221420' />
<event code='204' info='8' date='1686221420' />
<event code='204' info='9' date='1686221445' />
<event code='204' info='18' date='1686221451' />
<event code='204' info='16' date='1686221457' />
<event code='12' info='12' date='1686221459' />
<event code='2001' info='0' date='1686221747' />
<event code='20' info='229' date='1686235690' />
<event code='1121' info='0' date='1686235713' />
<event code='24' info='6300' date='1686235749' />
</events>
<weather_bin>
paX/
AVsAAADcSAAAyEkAAF7qgWQQAKQAnaADax4ABAACCIsYBwAHAAIIsBcFAAYAAgUhACkAMQAfAAIEPwAGAAU
AggAKADYAJwCLAAUAAAD8AREACwhINgAg+gESAAYH3QXZBeIF+wETAAIHCicKJwsnFQAUACYDlQCVABkAGg
ACAwAAAAAbACMABgfx//H/8f9YAgAAAgEcADcAKAALB/
YAAAD2AAAA9gAAADkAKQALAqMAAAA4ACoACwSNAQAA</weather_bin>
</station_xml>

------------------------------1234567890123456789012--
>
>> Downloading file from server
>
HTTP/1.1 200 OK
Server: nginx/1.18.0
Date: Thu, 08 Jun 2023 18:54:58 GMT
Content-Type: text/html; charset=UTF-8
Connection: close

---->> INFO <<----


IM-Request-Type: 1
IM-Checksum: 1902
IM-Hash: 0
IM-Content-Length: 784

---->> DATA <<----


<station_config>
<IM-RTC-TIME val="1686236098" />
<IM-STATION-NAME val="iMetos 3.3" />
<IM-APNTABLE val="3" />
<IM-SENSTABLE val="0" />
<IM-MEAS-INT val0='0;5;15' val1='1;5;15' val2='2;5;15' val3='3;5;15' val4='4;5;15'
val5='5;5;15' val6='6;5;15' val7='7;5;15' val8='8;5;15' />
<IM-MODE val="0" />
<IM-FIXED-TRANSF-INT val="30" />
<IM-RAIN-INT val="0"/>
<IM-EMG-SMS />
<IM-SMS-WARN-GSM />
<IM-SMS-WARN-VAL />
<IM-DATA-SCHED val='16777215;16777215;16777215;16777215;16777215;16777215;16777215'
/>
<IM-GPS-EN val="1"/>
<IM-SENSOR-CODE val1="4;4" val2="5;40" />
<IM-DB-DATE val="1679662522;1685040898" />
<IM-DB-UPLOAD val="1" />
<IM-WEB-CONN val="Close" />
<IM-JOBID val="upload_job_0020F7F2_1686250498.8098" />
<IM-RESPONSE-TIME val="0.0061" />
</station_config>
Updated station name
Updated warning values
Updated emergency number
Updated warning numbers
Updated rain interval
Updated data transmission schedule
Updated station mode
Updated scheduler settings
Updated fixed transfer interval
Updated server database dates
Updated sensor codes
Updated GPS Config: enabled
Updating internal measurement settings
Debug disabled
Updated RTC timestamp

NO CARRIER
> No worries, this is not really an error

+KTCP_DATA: 1,1038

+KTCP_NOTIF: 1,4
0
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
1
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
2
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
3
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
4
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
5
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
6
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
7
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
8
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00

###############################################################
MEASUREMENT PROCESS STARTED
08/06/2023 14:55:01
---------------------------------------------------------------
----------------- MEASUREMENT PROCESS RUNNING -----------------
AP Board ->
Main sensors:

Solar -> 6230 mV

Battery -> 6024 mV

Data collected
HygroClip A ->
>
>> Stopping bearer
>
AT+KCNXDOWN=1,1
OK

HygroClip B ->
{F00rdd 001; 99.91;%rh;000; ; 14.89;°C;000; ;nc;---.- ;°C;000; ;020;V1.2-
1;0020451711;HC2A ;000;=

Digital IO 1 ->
Duty->Name: SOLAR, CH: 0, Val: 30

Digital IO 2 ->

Digital IO 3 ->

Digital IO 4 ->

Dedicated PI Bus ->

Extension board A ->

Extension board B ->

------------------- DATABASE POST-PROCESSING ------------------


Updated sensor warning settings in RAM
Sensor Storage Finish -> No sensor warnings were generated
---------------------------------------------------------------
MEASUREMENT PROCESS FINISHED
###############################################################
Next comm: 08/06/2023 15:00:00

0
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
1
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
2
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
3
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
4
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
5
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
6
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
7
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
8
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00

###############################################################
SCHEDULER INFO: Battery under 6.3 V
###############################################################
>
>> Reading GPS, press ESC to cancel
>
$PUBX,40,GSA,0,1,0,0,0,0*4F
$PUBX,40,GGA,0,1,0,0,0,0*5B
7,58,351,28,68,57,230,13,69,10,207,*63
$GLGSV,3,2,10,77,36,148,28,78,56,239,44,79,16,286,34,86,05,144,37*6F
$GLGSV,3,3,10,87,11,093,19,88,01,047,*6B
$GNGLL,3424.77258,S,07118.62264,W,185510.00,A,D*70
$GNRMC,185511.00,A,3424.77261,S,07118.62264,W,0.044,,080623,,,D*6D
$GNVTG,,T,,M,0.044,N,0.081,K,D*31
$GNGGA,185511.00,3424.77261,S,07118.62264,W,2,12,0.71,141.9,M,27.8,M,,0000*4D
$GNGSA,A,3,17,13,14,15,12,30,19,24,05,46,48,,1.33,0.71,1.13*18
$GNGSA,A,3,78,66,67,77,79,,,,,,,,1.33,0.71,1.13*18
$GPGSV,3,1,12,05,22,326,39,12,15,314,36,13,84,083,39,14,34,135,34*79
$GPGSV,3,2,12,15,59,239,37,17,39,077,39,19,35,051,33,23,,,34*45
$GPGSV,3,3,12,24,28,245,37,30,16,097,37,46,18,290,39,48,21,293,41*77
$GLGSV,3,1,10,66,10,016,35,67,58,351,28,68,57,230,12,69,10,207,*62
$GLGSV,3,2,10,77,36,148,28,78,56,239,45,79,16,286,34,86,05,144,38*61
$GLGSV,3,3,10,87,11,093,,88,01,047,*63
$GNGLL,3424.77261,S,07118.62264,W,185511.00,A,D*7B
$GNRMC,185512.00,A,3424.77262,S,07118.62264,W,0.021,,080623,,,D*6E
$GNVTG,,T,,M,0.021,N,0.038,K,D*30
$GNGGA,185512.00,3424.77262,S,07118.62264,W,2,12,0.71,141.9,M,27.8,M,,0000*4D
1,32,23,,,34*44
$GPGSV,3,3,12,24,28,245,37,30,16,097,37,46,18,290,40,48,21,293,41*79
$GLGSV,3,1,10,66,10,016,34,67,58,351,28,68,57,230,11,69,10,207,19*68
$GLGSV,3,2,10,77,36,148,28,78,56,239,45,79,16,286,34,86,05,144,39*60
$GLGSV,3,3,10,87,11,093,,88,01,047,*63
$GNGLL,3424.77263,S,07118.62264,W,185514.00,A,D*7C
$GNRMC,185515.00,A,3424.77268,S,07118.62266,W,0.028,,080623,,,D*68
$GNVTG,,T,,M,0.028,N,0.051,K,D*36
$GNGGA,185515.00,3424.77268,S,07118.62266,W,2,12,0.71,141.7,M,27.8,M,,0000*4C
$GNGSA,A,3,17,13,14,15,12,30,19,24,05,46,48,,1.33,0.71,1.13*18
$GNGSA,A,3,78,66,67,69,77,79,,,,,,,1.33,0.71,1.13*17
$GPGSV,3,1,12,05,22,326,43,12,15,314,42,13,84,083,45,14,34,135,40*7F
$GPGSV,3,2,12,15,59,239,42,17,39,077,45,19,35,051,39,23,,,40*45
$GPGSV,3,3,12,24,28,245,42,30,16,097,42,46,18,290,45,48,21,293,47*7A
$GLGSV,3,1,10,66,10,016,34,67,58,351,32,68,57,230,11,69,10,207,20*69
$GLGSV,3,2,10,77,36,148,31,78,56,239,46,79,16,286,38,86,05,144,41*68
$GLGSV,3,3,10,87,11,093,,88,01,047,*63
$GNGLL,3424.77268,S,07118.62266,W,185515.00,A,D*74
$GNRMC,185516.00,A,3424.77267,S,07118.62266,W,0.020,,080623,,,D*6C
$GNVTG,,T,,M,0.020,N,0.037,K,D*3E
$GNGGA,185516.00,3424.77267,S,07118.62266,W,2,12,0.62,141.9,M,27.8,M,,0000*4C
19,35,051,37,23,,,39*47
$GPGSV,3,3,12,24,28,245,42,30,16,097,42,46,18,290,45,48,21,293,46*7B
$GLGSV,3,1,10,66,10,016,35,67,58,351,32,68,57,230,,69,10,207,23*6B
$GLGSV,3,2,10,77,36,148,31,78,56,239,47,79,16,286,39,86,05,144,40*69
$GLGSV,3,3,10,87,11,093,26,88,01,047,*67
$GNGLL,3424.77269,S,07118.62267,W,185518.00,A,D*79
$GNRMC,185519.00,A,3424.77270,S,07118.62267,W,0.044,,080623,,,D*66
$GNVTG,,T,,M,0.044,N,0.081,K,D*31
$GNGGA,185519.00,3424.77270,S,07118.62267,W,2,12,0.62,142.2,M,27.8,M,,0000*4C
$GNGSA,A,3,17,13,14,15,12,30,19,24,05,46,48,,1.18,0.62,1.00*11
$GNGSA,A,3,78,66,67,69,77,79,,,,,,,1.18,0.62,1.00*1E
$GPGSV,3,1,12,05,22,326,44,12,15,314,41,13,84,083,44,14,34,135,40*7A
$GPGSV,3,2,12,15,59,239,41,17,39,077,44,19,35,051,37,23,,,39*47
$GPGSV,3,3,12,24,28,245,42,30,16,097,42,46,18,290,45,48,21,293,46*7B
$GLGSV,3,1,10,66,09,016,35,67,58,351,32,68,57,230,,69,10,207,24*64
$GLGSV,3,2,10,77,36,148,30,78,56,239,47,79,16,286,38,86,05,144,40*69
$GLGSV,3,3,10,87,11,093,26,88,01,047,*67
$GNGLL,3424.77270,S,07118.62267,W,185519.00,A,D*70
$GNRMC,185520.00,A,3424.77272,S,07118.62267,W,0.028,,080623,,,D*64
$GNVTG,,T,,M,0.028,N,0.051,K,D*36
$GNGGA,185520.00,3424.77272,S,07118.62267,W,2,12,0.62,142.2,M,27.8,M,,0000*44
,35,051,36,23,,,39*46
$GPGSV,3,3,12,24,28,245,42,30,16,097,41,46,18,290,45,48,21,293,46*78
$GLGSV,3,1,10,66,09,016,34,67,57,351,32,68,57,231,,69,10,208,23*63
$GLGSV,3,2,10,77,36,148,29,78,56,239,47,79,16,286,38,86,05,144,40*61
$GLGSV,3,3,10,87,11,093,26,88,01,047,*67
$GNGLL,3424.77276,S,07118.62267,W,185522.00,A,D*7E
$GNRMC,185523.00,A,3424.77277,S,07118.62268,W,0.018,,080623,,,D*6E
$GNVTG,,T,,M,0.018,N,0.033,K,D*31
$GNGGA,185523.00,3424.77277,S,07118.62268,W,2,12,0.62,142.3,M,27.8,M,,0000*4C
$GNGSA,A,3,17,13,14,15,12,30,19,24,05,46,48,,1.18,0.62,1.00*11
$GNGSA,A,3,78,66,67,69,77,79,,,,,,,1.18,0.62,1.00*1E
$GPGSV,3,1,12,05,22,326,44,12,15,314,41,13,84,083,44,14,34,135,41*7B
$GPGSV,3,2,12,15,59,239,41,17,39,077,44,19,35,051,37,23,,,39*47
$GPGSV,3,3,12,24,28,245,42,30,16,097,41,46,18,290,45,48,21,293,46*78
$GLGSV,3,1,10,66,09,016,34,67,57,351,32,68,57,231,,69,10,208,23*63
$GLGSV,3,2,10,77,36,148,29,78,56,239,47,79,16,286,38,86,05,144,39*6F
$GLGSV,3,3,10,87,11,093,26,88,01,047,*67
$GNGLL,3424.77277,S,07118.62268,W,185523.00,A,D*71
$GNRMC,185524.00,A,3424.77279,S,07118.62268,W,0.028,,080623,,,D*64
$GNVTG,,T,,M,0.028,N,0.051,K,D*36
$GNGGA,185524.00,3424.77279,S,07118.62268,W,2,12,0.62,142.3,M,27.8,M,,0000*45
,051,37,23,13,228,39*7D
$GPGSV,3,3,12,24,28,245,42,30,16,097,42,46,18,290,45,48,21,293,46*7B
$GLGSV,3,1,10,66,09,016,33,67,57,351,32,68,57,231,,69,10,208,22*65
$GLGSV,3,2,10,77,36,148,30,78,56,239,47,79,16,286,38,86,05,144,41*68
$GLGSV,3,3,10,87,11,093,26,88,01,047,*67
$GNGLL,3424.77284,S,07118.62269,W,185526.00,A,D*79
$GNRMC,185527.00,A,3424.77285,S,07118.62269,W,0.051,,080623,,,D*6B
$GNVTG,,T,,M,0.051,N,0.094,K,D*31
$GNGGA,185527.00,3424.77285,S,07118.62269,W,2,12,0.59,142.2,M,27.8,M,,0000*4D
$GNGSA,A,3,17,13,14,15,12,30,19,24,05,46,48,23,1.13,0.59,0.97*1C
$GNGSA,A,3,78,66,67,69,77,79,,,,,,,1.13,0.59,0.97*12
$GPGSV,3,1,12,05,22,326,40,12,15,314,36,13,84,083,40,14,34,135,36*7B
$GPGSV,3,2,12,15,59,239,37,17,39,077,40,19,35,051,33,23,13,228,35*70
$GPGSV,3,3,12,24,28,245,38,30,16,097,37,46,18,290,41,48,21,293,42*74
$GLGSV,3,1,10,66,09,016,30,67,57,351,29,68,57,231,,69,10,208,23*6D
$GLGSV,3,2,10,77,36,148,27,78,56,239,44,79,16,286,36,86,05,144,38*6D
$GLGSV,3,3,10,87,11,093,27,88,01,047,*66
$GNGLL,3424.77285,S,07118.62269,W,185527.00,A,D*79
$GNRMC,185528.00,A,3424.77287,S,07118.62269,W,0.050,,080623,,,D*67
$GNVTG,,T,,M,0.050,N,0.092,K,D*36
$GNGGA,185528.00,3424.77287,S,07118.62269,W,2,12,0.59,142.2,M,27.8,M,,0000*40
9,19,35,051,32,23,13,228,34*7E
$GPGSV,3,3,12,24,28,245,37,30,16,097,37,46,18,290,40,48,21,293,41*79
$GLGSV,3,1,10,66,09,016,32,67,57,351,28,68,57,231,,69,10,208,22*6F
$GLGSV,3,2,10,77,36,148,26,78,56,239,45,79,16,286,35,86,05,144,40*61
$GLGSV,3,3,10,87,11,093,22,88,01,047,*63
$GNGLL,3424.77286,S,07118.62269,W,185530.00,A,D*7C
$GNRMC,185531.00,A,3424.77289,S,07118.62269,W,0.015,,080623,,,D*60
$GNVTG,,T,,M,0.015,N,0.028,K,D*36
$GNGGA,185531.00,3424.77289,S,07118.62269,W,2,12,0.59,142.0,M,27.8,M,,0000*44
$GNGSA,A,3,17,13,14,15,12,30,19,24,05,46,48,23,1.13,0.59,0.97*1C
$GNGSA,A,3,78,66,67,69,77,79,,,,,,,1.13,0.59,0.97*12
$GPGSV,3,1,12,05,22,326,45,12,15,314,41,13,84,083,46,14,34,135,44*7D
$GPGSV,3,2,12,15,59,239,41,17,39,077,46,19,35,051,37,23,13,228,40*71
$GPGSV,3,3,12,24,28,245,42,30,16,097,42,46,18,290,46,48,21,293,48*76
$GLGSV,3,1,10,66,09,016,35,67,57,351,32,68,57,231,,69,10,208,22*63
$GLGSV,3,2,10,77,36,148,30,78,56,238,47,79,16,286,38,86,05,144,37*68
$GLGSV,3,3,10,87,11,093,24,88,01,047,*65
$GNGLL,3424.77289,S,07118.62269,W,185531.00,A,D*72
$GNRMC,185532.00,A,3424.77288,S,07118.62268,W,0.023,,080623,,,D*66
$GNVTG,,T,,M,0.023,N,0.042,K,D*3F
$GNGGA,185532.00,3424.77288,S,07118.62268,W,2,12,0.59,142.0,M,27.8,M,,0000*47
,39,077,45,19,35,051,39,20,,,31*44
$GPGSV,4,3,13,23,13,228,39,24,28,245,42,30,16,097,40,46,18,290,45*7B
$GPGSV,4,4,13,48,21,293,46*4E
$GLGSV,3,1,10,66,09,016,33,67,57,351,32,68,57,231,,69,10,208,25*62
$GLGSV,3,2,10,77,36,148,31,78,56,238,47,79,17,285,37,86,05,144,42*66
$GLGSV,3,3,10,87,11,093,26,88,01,047,*67
$GNGLL,3424.77287,S,07118.62265,W,185534.00,A,D*75
$GNRMC,185535.00,A,3424.77288,S,07118.62267,W,0.029,,080623,,,D*64
$GNVTG,,T,,M,0.029,N,0.053,K,D*35
$GNGGA,185535.00,3424.77288,S,07118.62267,W,2,12,0.59,142.0,M,27.8,M,,0000*4F
$GNGSA,A,3,17,13,14,15,12,30,19,24,05,46,48,23,1.13,0.59,0.97*1C
$GNGSA,A,3,78,66,67,69,77,79,,,,,,,1.13,0.59,0.97*12
$GPGSV,4,1,13,05,22,326,44,12,15,314,40,13,84,083,44,14,34,135,40*7D
$GPGSV,4,2,13,15,59,239,42,17,39,077,45,19,35,051,37,20,,,31*48
$GPGSV,4,3,13,23,13,228,39,24,28,245,41,30,16,097,41,46,18,290,45*79
$GPGSV,4,4,13,48,21,293,46*4E
$GLGSV,3,1,10,66,09,016,35,67,57,351,33,68,57,231,,69,10,208,27*67
$GLGSV,3,2,10,77,36,148,31,78,56,238,47,79,17,285,38,86,05,144,42*69
$GLGSV,3,3,10,87,11,093,26,88,01,047,*67
$GNGLL,3424.77288,S,07118.62267,W,185535.00,A,D*79
$GNRMC,185536.00,A,3424.77288,S,07118.62267,W,0.003,,080623,,,D*6F
$GNVTG,,T,,M,0.003,N,0.005,K,D*3E
$GNGGA,185536.00,3424.77288,S,07118.62267,W,2,12,0.59,142.0,M,27.8,M,,0000*4C
$PUBX,40,GGA,0,0,0,0,0,0*5A
$PUBX,40,GSA,0,0,0,0,0,0*4E
>
>> Waiting new SMS, could take 5 minutes, press ESC to cancel
>
>
>> Attempting to send SMS
>
>
>> Waiting new SMS, could take 5 minutes, press ESC to cancel
>
>
>> Success
>
>
>> Turning modem off
>
AT+CFUN=4
+CGREG: 0

OK
AT+CPWROFF
OK
Next comm: 08/06/2023 15:00:00

0
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
1
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
2
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
3
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
4
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
5
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
6
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
7
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00
8
Next meas: 08/06/2023 15:00:00
Next log: 08/06/2023 15:00:00