HAZARDOUS PLOT PLAN (Air Compressor Location)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

DRG NO JOB NO

8 7 6 5 4 3 2 1

NOTES
0500-STR-2-001 0500-STR-2-001 0500-STR-2-001 0500-STR-2-001 0500-STR-2-001 0500-STR-2-001 0500-STR-2-001

THIS DRAWING
1 2 3 4 3 4 3 4 1 2 3 4 1 2 3 4 1 2 3 1 2
PLANT
NORTH 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 P.N
NORTH 1750 4000 1750

E-0541S2
(FUTURE)

2E-0541
2E-0541S

2E-0546
2E-0513
3750 4250

4500 3000
4000

2500
PREVAILING 1.0M
A A A A

4500
0500-STR-2-001
1750 4000
WIND

7500

7500

7500

1000
2C-0543

7500
2C-0543 2C-0543 A’ A’

4500
2000
E A’ 1C-0543 2000 VALVE ACCESS E
VALVE ACCESS

2E-0522
2E-0544
3500

1000
PLATFORM
F.S F.S F.S PLATFORM
B B B B B B B

1000
1200 3300 F.S

7500

7500

7500

7500

7500
5500

2000 CONCRETE
TABLE TOP 1.0M
C 1.0M C C C C
1.0M 1.0M 1.0M

7500

7500
1.0M

A A
KEY PLAN
7 8 9 10 7 8 9 10 7 8 9 10

FGP-0500-STR-2-001 FGP-0500-STR-2-001 GENERAL NOTES

1. THIS DRAWING IS DEFINED IN ACCORDANCE WITH THE


INSTITUTE OF PETROLEUM MODEL CODE OF SAFE PRACTICE
FGP-0500-STR-2-001 FGP-0500-STR-2-001 FGP-0500-STR-2-001 FGP-0500-STR-2-001
FGP-0500-STR-2-001 -PART 15, 2002 (2ND EDITION)

2.FOR GENERAL GUIDANCE ON METHOD OF CALCULATION OF


INDIVIDUAL HAZARD RADII REFER TO HAZARDOUS AREA
147750
CLASSIFICATION GUIDANCE REPORT DOCUMENT No.
T-13.376.855.
0500-CS-2-001 0500-STR-2-001 0500-SR-2-002 0500-SR-2-001
3. A 1.8M ZONE 2 HAZARDOUS RADIUS IS APPLIED ALONG THE
PIPE RACK ASSUMING WELL MAINTAINED VALVES AND FLANGES
1 2 3 1 2 3 4 1 2 1 2 WILL BE PRESENT.

11250 6000 10000 21500 7500 7500 7500 26000 4000 22500 6000 18000 4.HV MOTORS IN HAZARDOUS AREAS SHALL BE CERTIFIED FOR
D D
USE WITHIN A ZONE 2 IIB T3 HAZARDOUS AREA AS A

PN= 925.500 AIR COMPRESSOR LOCATION PN= 925.500


MINIMUM.

PE=1028.500 PE=1176.250 5.ALL ELECTRICAL LV MOTORS SHALL BE CERTIFIED FOR USE


WITHIN A ZONE 2 IIC T3 HAZARDOUS AREA AS A MINIMUM.
RESTRICTED ROAD (6m WIDE)
C
L

2S-0541
6. ALL LUMINAIRES, JUNCTION BOXES & CONVENIENCE OUTLETS

2S-0542
ROAD
SHALL BE SUITABLE FOR A ZONE 1 IIC T4 HAZARDOUS AREA

2T-8267
AS A MINIMUM (REFER TO DEP 33.64.10.10-GEN).

MIN.
OTHER FIELD EQUIPMENT (E.G. CONTROL PANELS, WELDING

COMP.

OF

18000
3.0M 3.0M OUTLETS & INSTRUMENTATION) SHALL BE SUITABLE FOR A

F/D

AOC DRAIN
7250 3000 ZONE 2 IIC T4 HAZARDOUS AREA AS A MINIMUM.

15.0m
EDGE
3.0M
2000
26500

7.PIPING FLANGES & VALVES ON MAIN PIPE RACKS SHALL NOT


No.T-4.044.295

OF

OF
BE LOCATED WITHIN 3M OF UNRESTRICTED ROADS.
CRANE D.

STAIRWELL
A

E-0543S2
ACCESSWAY
LGT 1500
LGT 5000 APRON LGT LGT R

TO
8.WHERE THE HAZARDOUS AREA EXTEDS OVER ROAD, THOSE
L

L
AOC DRAIN

2E-0543
0m
C

C
4000 4000 3500

40003500 4000 2200


275 MH
. ROADS SHALL BE DESIGNATED AS ’RESTRICTED ACCESS’
BATTERY LIMIT AOC DRAINAGE TRENCH 15

3900

500

6000 4000
& SUITABLE BARRIES & SIGNS SHALL BE PROVIDED TO

2P-0544A/B

4400
(A) 2V-0542
PREVENT UNAUTHORISED TRAFFIC FROM USING THE ROADS.
CRANE

4500
APRON KERB CRANE 9.AOC & COC IS TREATED CONSERVATIVELY AS ELONGATED SUMPS.

FGP-0500-SR-2-002
KERB

1800
CRANE 1750 3800 1950 3500 2750 APRON (REFER TO T-13.376.855 PARA 4.3.10)

2500

2P-0541A/B
(A)

2750
APRON 2F-0511
A (B)
4650 5000
0500-STR-2-001

A NOTE-4

WIDE)
538 LEGENDS

4000 3500 4000 2000 6000


DRAWING

2C-0544 A

2V-8265
3000 5000

2P-8265

BATTERY LIMIT
7500

2KM-0562

3250
2C-0543 A

1500
1000 9000 1000

7000
2V-0543

2V-0544
7000

FGP-0500-SR-2-001
OIL CONSOLE

B KERB (B) ZONE 1, Gas Gr IIA & IIB, T3

1500
2P-0573
F.S.2P-0572

B’ C 1500

2750
L OF 4500 3500 3500
4000 KERB

(6m
2S-0571
B DISC. 2P-0545
2K-0562

3500
DIS. SUC.
C
7500

B ZONE 2, Gas Gr IIA & IIB, T3


SEE

2V-0512
2500
(A)

7000
FGP-0500- 2000
4500
6350

C C

2500

7000
DISC.

PIT

ROAD
CRANE
3640

DIS. SUC. STR-2-001 2S-0521

1500
F.S. F.S.
A/B

APRON
(B)
4500 3000

CONTINUATION

KERB 2C-0541 2P-0542 F.S.

2E-0514
C’
C A/B

SUMP
D 750 C
C

RESTRICTED
FGP-0500-CS-2-001
7500

2V-0545 F.S.
7000

7000
1.0M 2V-0521

8800
6000
3750

5000

5000
4000
2V-0541NOTE-2 SUMP PIT SPECIFIC NOTE
2000 4000 (A) (B)
2V-0572
0500-PR-2-001

1300 4500 1. ANALYZER SYSTEMS RETURN SAMPLES TO PROCESS OR FLARE

66000
A LINES. INSTRUMENT HIGH VENTS WILL NOT BE APPLIED.
3000
VALVE ACCESS 15.0m MIN.
102000

10000

4000 2.THE COMPRESSOR SHELTER FOR 2K-0562 SHALL BE ADEQUATELY


TO EDGE OF ROAD
2E-0512 2E-0521 2E-0545 2E-0542 VENTILATED WITH 12 AIR CHANGES PER HOUR AND SHALL BE
FOR

C
STAIRWELL CLASSIFIED AS A ZONE 2 HAZARDOUS AREA.
FGP-0500-PR-2-001 (REFER TO IP15 TABLE 6.1).
FOR DETAIL OF COMPRESSOR SHELTER REFER TO STUDY-REPORT
MATCHLINE

3400

B
COMPRESSOR SHELTERS DOCUMENT
3400

7000
9100

9100

10500

10500
4000

3700 4200 4000

3. DURING CLEANING HYDROCARBONS ON THE FILTER MAY BE


AH-22 NOTE-1

1.8M
1.8M EXPOSED TO ATM FOR >10 HRS/YEAR.
CRANE 2S-0511,2S-0531
CRANE CRANE
3700 4200

APRON APRON CRANE


APRON APRON 4. HAZARDOUS SOURCES OF RELEASE ARE FLANGES AND
400

2V-0501
400

INTERCONNECTING PIPEWORK BETWEEN FURNACE AND FUEL


13000

1.0M CRANE FEED LINES & PROCESS LINE ONLY.


2V-0531 APRON
1.0M 1.0M 1.0M 2F-0511
EQUIPMENT LIST (A) (B) (C) (D) (E) (F)
2S-0511
2S-0531

NOTE-3
NOTE-3

2V-0511A/B 2V-0511C/D 2V-0511E/F 5. A 1.8M ZONE 2 HAZARDOUS RADIUS IS APPLIED ALONG THE
NAME DESCRIPTION

AOC DRAIN
43000

3.0M FOLLOWING STRUCTURE ASSUMING WELL MAINTAINED VALVES


15.0m MIN.
AND FLANGES WILL BE PRESENT.
2C-0541 SULFINOL MAIN ABSORBER TO EDGE OF ROAD
2C-0543 SULFINOL RECONTACTOR 3200 2800 2800 3200 2800
2C-0544 SULFINOL REGENERATOR
ROAD

AOC DRAINAGE TRENCH


B 2175 BATTERY LIMIT B
MIN.

REFERENCE DRAWING
14550 7400 7500 7500 26700 8200 18050 8200 18050 8200 5400
2F-0511 REGENERATION GAS HEATER AOC DRAIN AOC DRAIN AOC DRAIN
LGT LGT LGT LGT MH HAZARDOUS SOURCE LIST ( PHASE-2 ) T-4.226.549
OF

1 2 1 2

18000
15.0m

2K-0562 REGENERATION GAS COMPRESSOR 3.0M TYPICAL DETAIL DRAWING FOR HAZARDOUS AREA T-4.043.562
CLASSIFICATION
EDGE

2KM-0562 REGENERATION GAS COMPRESSOR


MOTOR 0500-STR-2-002 0500-STR-2-003
HAZARDOUS AREA CLASSIFICATION LAYOUT T-4.043.563
PN= 823.500 KEY PLAN
PE=1055.750
TO

MATCHLINE FOR CONTINUATION


UNRESTRICTED ROAD (6m WIDE)
CL
SEE DRAWING No.T-4.044.297 MATCHLINE FOR CONTINUATION SEE DRAWING No.T-4.044.298

3750 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 6000
PN= 823.500 PN= 823.500 B 15/09/11 H.H M.F H.N ISSUED FOR AS BUILT
PE=1028.500 PE=1176.250
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 A 30/06/09 H.H M.F H.N ISSUED FOR CONSTRUCTION

O 24/12/08 H.H M.F H.N ISSUED FOR COMPANY COMMENT


0500-PR-2-001
ISSUE DATE MADE CHECK’D APPR’D DESCRIPTION
129750 18000

Pearl GTL Project - Qatar YOKOHAMA JAPAN

This document is confidential. Neither the whole nor any part of this document may be disclosed to any
EQUIPMENT LIST EQUIPMENT LIST EQUIPMENT LIST EQUIPMENT LIST third party without the prior written consent of CHIYODA-HHI CONSORTIUM (CHC).
Title in respect of this document is vested in Qatar Shell GTL Limited. Neither the whole nor any part of
this document may be reproduced, stored in any retrieval system or transmitted in any form or by any means
NAME DESCRIPTION NAME DESCRIPTION NAME DESCRIPTION NAME DESCRIPTION (electronic, mechanical, reprographic, recording or otherwise) without the prior consent of CHC.

HAZARDOUS AREA LAYOUT


2E-0512 REGENERATION GAS FEED AIR COOLER 2P-0541A/B HP SULFINOL PUMP 2S-0511 DRIED GAS FILTER 2V-0501 WET GAS SEPARATOR
A 2E-0513 REGENERATION GAS FEED WATER COOLER 2P-0542A/B WASH WATER CIRCULATION PUMP 2S-0521 KO WATER FILTER 2V-0511A to F WET GAS DRIER SWEETENING VESSEL DMR UNIT (PHASE 2) A

2E-0514 REGENERATION GAS PRE-HEATER 2P-0544A/B LP SULFINOL PUMP 2S-0531 TREATED GAS STRAINER 2V-0512 REGEN GAS HEATER FUEL GAS KO DRUM
2E-0521 REGENERATION GAS COOLER 2P-0545A/B REGENERATOR REFLUX PUMP 2S-0541 LEAN SULFINOL FILTER 2V-0521 REGENERATION GAS SEPARATOR
2E-0522 REGENERATION GAS TRIM COOLER 2P-0572 SULFINOL MAKE UP PUMP 2S-0542 RECIRCULATION SULFINOL FILTER 2V-0531 MERCURY ADSORBER VESSEL PROJECT/GROUP/LOCATION HP-3000-QAT CONTRACTOR PROJECT No 5887
2E-0541 LEAN SULFINOL TRIM COOLER 2P-0573 DRAIN VESSEL HYDOCARBON PUMP 2S-0571 SULFINOL FILTER 2V-0541 COMPRESSOR SUCTION KO DRUM CONTRACTOR CONTRACT No PI-096 ORIGINATING ORGANISATION CHC
E-0541S2 LEAN SULFINOL TRIM COOLER (SPARE) 2P-8265 SOUR COC SUMP VESSEL PUMP 2V-0542 ACTIVATED CARBON FILTER
2T-8267 DMR COC SUMP NO.2 CONTRACTOR NAME CHIYODA - HHI CONSORTIUM
2E-0542 LEAN SULFINOL AIR COOLER 2V-0543 PEAK RICH SULFINOL FLASH DRUM
2E-0543 LEAN/RICH EXCHANGER 2V-0544 RICH SULFINOL FLASH DRUM
UNIT 2-0500
E-0543S2 LEAN/RICH EXCHANGER (SPARE) 2V-0545 REGENERATOR REFLUX DRUM
2E-0544 SULFINOL REGENERATOR REBOILER 2V-0572 SULFINOL DRAIN VESSEL AS BUILT CONTRACTOR
2E-0545 REGENERATOR OVERHEAD CONDENSER 2V-8265 SOUR COC SUMP VESSEL PCWBS KA NA (QPG JOB No 51505)
DRG No
2E-0546 REGENERATOR OVERHEAD TRIM COOLER
AH-22 ANALYZER HOUSE NO.22
SCALE 1:300 PROJECT DRG No T-4.044.296 REV B

BDR SIZE ; A0
A0 1189X841 8 7 6 5 4 3 2 1
FILENAME
T4044296REVB_F002.DGN