Professional Documents
Culture Documents
Httpsdocs - Rs Online - Comba350900766b81544c72 PDF
Httpsdocs - Rs Online - Comba350900766b81544c72 PDF
With Detection of
Residual pressure
release valve
The detecting function of the main valve position detects a Safety limit switch
mismatch between the input signal and valve operation.
VP542-X536/VP742-X536
Redundant system can be When the dual residual pressure release valve is
used, if one of the valves fails to operate, the
constructed easily. other one releases residual pressure.
Category 3, 4
With Soft Start-up Function
Dual Residual Pressure Release Valve VP544-X555/VP744-X555 (0.7 MPa) Dual Residual Pressure Release Valve
VP544-X538/VP744-X538 VP544-X585/VP744-X585 (1.0 MPa) VG342-X87
Residual pressure Residual pressure
release valve w release valve w
Residual pressure
Residual pressure
release valve q
release valve q
Safety limit
switch
Soft start-up
valve
Redundant System
A system in which even if one part fails, the whole system
will fulfill its required function. This is usually achieved by
having dual channels of operation, such as dual valves, dual
wiring, dual guard switches etc.
SeriesVP/VG
CAT.EUS11-111Aa-UK
Safety Standard ISO 13849-1 Certified
3 Port Solenoid Valve/Residual Pressure Release Valve with Detection of Main Valve Position Series VP/VG
With Detection of Main Valve Position (Category 2) Redundant system can be constructed easily. (Category 3, 4)
Category 2 Safety function can be accomplished by single channel and is automatically Category 3 It has redundancy so there is no loss of safety function with a single failure.
checked. The safety function must be checked before each use. An accumulation of
undetected faults can cause loss of safety function.
Category 4 It has redundancy so there is no loss of safety function with a single failure. The
safety function must be checked before each use. An accumulation of undetected
faults does not affect the safety function. (Higher DC and MTTFd than Category 3.)
Monitoring
I Input signal L O I1 Input signal L1 O1
Logical operation Logical operation
Input equipment Output signal Output equipment Input equipment Output equipment
equipment equipment Output signal
Monitoring
Cross monitoring
Monitoring
TE OTE I2 Input signal L2 O2
Logical operation
Testing equipment Output signal Output of test result Input equipment Output equipment
equipment Output signal
The detecting function of the main valve position detects a When the dual residual pressure release valve is used, if one of the
mismatch between the input signal and valve operation. valves fails to operate, the other one releases residual pressure.
Input equipment (I) : Detection equipment (sensor) of starting event Input equipment (I1, I2): Detection equipment (sensor) of starting event
Logical operation equipment (L) : Relay sequence circuit, PLC control program Logical operation equipment (L1, L2): Relay sequence circuit, PLC control program
Output equipment (O) : Solenoid valve, Electromagnetic switch, Output relay Output equipment (O1, O2): Solenoid valve, Electromagnetic switch, Output relay
Recommended valve : VP542/742-X536 Recommended valve: VP544/744-X538, VG342-X87
1
Safety Standard ISO 13849-1 Certified
3 Port Solenoid Valve/Residual Pressure Release Valve with Detection of Main Valve Position Series VP/VG
Series Variations
Flow rate characteristics
Port C [dm3/(s·bar)]/Q [l/min (ANR)]∗ 1!2 (P!A)
Series Category Thread
size
5 10 15 20 25
Residual Pressure
Release Valve 3/8"
Rc,
8.9/2085
VP542-X536
2 G,
Residual Pressure NPT
Release Valve 1/2" 15.1/3637
VP742-X536
Dual Residual Pressure
Release Valve 3/8" 6.5/1461
VP544-X538 Rc,
G,
Dual Residual Pressure NPT
Release Valve 1/2" 10.3/2315
VP744-X538
Dual Residual Pressure Release
Valve with Soft Start-up Function 3, 4 3/8"
Rc,
5.2/1157
VP544-X555/VP544-X585
85
G,
Dual Residual Pressure Release NPT
Valve with Soft Start-up Function 1/2" 9.8/2203
VP744-X555/ VP744-X585
X585
Dual Residual Pressure
ure Rc, 2
26.6/
Release Valve 3/4" G,
VG342-X87 NPT 55864
∗ These values have been calculated according to ISO 6358 and indicate the flow rate under standard conditions with an inlet pressure of 0.6 MPa (relative pressure)
and a pressure drop of 0.1 MPa
2
Safety Standard ISO 13849-1 Certified
∗
Electrical entry
Safety limit switch/Wiring
D DIN terminal
— G 1/2 (Made by OMRON)
Y DIN (EN 175301-803) terminal
M M12 connector (Made by OMRON)
∗ Refer to page 18 for details about type Y.
M12 connector
S1 (Made by Rockwell Automation)
Light/surge voltage suppressor
Z With light/surge voltage suppressor With check valve (Only external pilot)
Check Applicable Thread
valve tube O.D. Rc G NPT
Port size
Port size VP500 VP700 — None — ! ! !
03 3/8" ! — A Ø6 ! — —
Yes
04 1/2" — ! B Ø 1/4∗ — — !
∗ For internal pilot, the symbol is nil.
∗ Refer to “Piping for External Pilot Type” on page 4 for
selection of the check valve.
Made to Order
Valve Specifications
VP500/700
VP"42-X536 VP"42R-X536
Model VP"44-X538 VP"44R-X538 VP"44-X585 VP"44R-X585
VP"44-X555 VP"44R-X555
Fluid Air
Type of actuation N.C. (Spring return)
Operation Internal pilot External pilot Internal pilot External pilot
Operating pressure range 0.25 to 0.7 MPa 0.25 to 1.0 MPa
External pilot pressure — 0.25 to 0.7 MPa (Same as operating pressure)
Maximum operating frequency 30 times/minute
Minimum operating frequency 1 time/week
Operating and ambient temperature -10 to 50 °C (No freezing)
Symbols
Ambient humidity 20 to 90 %RH (No condensation)
Manual override None
Pilot exhaust Individual exhaust
Lubrication Not required
Mounting orientation Unrestricted
X536
Impact/Vibration resistance 150/30 m/s2
Enclosure IP65
Operating environment Indoors
10000000 times (for the safety limit switch made by OMRON)
B10d (MTTFd calculation) 1000000 times
1000000 times (for the safety limit switch made by Rockwell Automation)
X538
Internal Pilot Type Piping for External Pilot Type
Caution Caution
Valve may not operate properly when air sup- The product may not operate when the external pilot
ply to P port is not adequate and the supply pressure is insufficient due to simultaneous opera-
X555
X585
pressure to the valve is lower than 0.25 MPa, tion or restricted air piping. In this case, use the
the minimum operating pressure. Be careful check valve (AKH series) with the external pilot port,
with insufficient supply pressure. change the piping size or adjust the set pressure to
provide a constant pressure of 0.25 MPa or more.
Accessories
Flow Rate Characteristics / Weight
Optional
Flow rate characteristics
Weight
Series 1!2 (P!A) 2!3 (A!R)
∗ ∗ [g]
C [dm /(s·bar)] b
3
Cv Q [l/min (ANR)] C [dm /(s·bar)] b
3
Cv Q [l/min (ANR)]
Specific Product
Precautions
VP542-X536 8.9 0.16 2.2 2085 8.9 0.20 2.1 2132 350
VP742-X536 15.1 0.21 3.6 3637 15.3 0.22 3.7 3707 590
VP544-X538 6.5 0.08 1.3 1461 6.7 0.10 1.3 1521 930
VP744-X538 10.3 0.08 2.3 2315 9.7 0.08 2.1 2180 1510
VP544-X555
5.2 0.06 1.1 1157 6.7 0.10 1.3 1521 1105
VP544-X585
VP744-X555
9.8 0.08 2.1 2203 9.7 0.08 2.1 2180 2000
VG342
VP744-X585
∗ These values have been calculated according to ISO 6358 and indicate the flow rate under standard
conditions with an inlet pressure of 0.6 MPa (relative pressure) and a pressure drop of 0.1 MPa
500
0.7 MPa
400
0.5 MPa
300
0.25 MPa
X87
200
100
0
0 0.5 1 1.5 2 2.5 3 3.5 4
Specific Product
Precautions
Symbols
Safety limit switch
Made by
OMRON
q (11)
11 12
w (12)
r (32)
VP542(R) /742(R)-X536
Internal pilot External pilot External pilot/With check valve
w r w r w r
2(A) (12) (32) 2(A) (12) (32) 2(A) (12) (32)
1(P) 3(R) (11) (31) 1(P) 3(R) (11) (31) 1(P) 3(R) (11) (31)
q e q e q e
VP544(R) /744(R)-X538
Internal pilot External pilot External pilot/With check valve
w r w r w r
2(A) (12) (32) 2(A) (12) (32) 2(A) (12) (32)
VP544(R) /744(R)-X555
VP544(R) /744(R)-X585
Internal pilot External pilot External pilot/With check valve
2(A) 2(A) 2(A)
w r w r w r
(12) (32) (12) (32) (12) (32)
5
3 Port Solenoid Valve/
VP-X536, X538, X555, X585
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position
Symbols
VP500/700
Safety limit switch
Made by
Rockwell Automation
Symbols
q
t
w
y
X536
e
r
X538
VP542(R)/742(R)-X536
Internal pilot External pilot External pilot/With check valve
2(A) tyr 2(A) tyr 2(A) tyr
X555
X585
1(P) 3(R) qwe 1(P) 3(R) qwe 1(P) 3(R) qwe
Accessories
Safety limit switch terminal [N.C.] X X
Optional
M12 connector pin number
VP544(R)/744(R)-X538
Specific Product
Internal pilot External pilot External pilot/With check valve
Precautions
2(A) tyr 2(A) tyr 2(A) tyr
VG342
3(R) qwe 3(R) qwe 3(R) qwe
6
VP-X536
VP542(R)-5 DY Z1-03$-$-X536
VP542(R)-5 DY Z1-03$-M$-X536
(31.5
)
Safety limit switch (Distan
ce b
etween
Made by 3/8" ports)
OMRON 32
[1(P), 3(R) port]
70.8
63.3
(With check valve)
A
31.5
45
40
(22.9)
23.5 117.4
4
3/8"
Port size: 1/8" (Without check valve)
[2(A) port]
Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
2 x Ø 4.2 31 (External pilot port)
3.5
(For mounting)
4.5
View A
26
22.1
118.9 Pin
(Max. 10) 201.8 number
VP542(R)-5 DY Z1-03$-S1$-X536
(31.5
Safety limit switch )
(Distan
ce between
Made by 3/8" ports)
Rockwell Automation [1(P), 3(R) port]
32
7
2 x Ø 4.2
(For mounting)
70.8
63.3
(With check valve)
A
31.5
45
40
25.2
(22.9)
216.7 8
3/8"
Port size: 1/8" (Without check valve)
[2(A) port]
Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
2 x Ø 4.2 31 (External pilot port)
3.5
(For mounting)
4.5
View A
M12 connector
26
22.1
133.2 Pin
(Max. 10) 216.1 number
7
3 Port Solenoid Valve/
VP-X536
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position
VP742(R)-5 DY Z1-04$-$-X536
VP500/700
VP742(R)-5 DY Z1-04$-M$-X536 (43) (D
istance
between
ports)
Safety limit switch
Made by 40
9
OMRON
Vent port 42
(Ø 6.2) 73.5 107.9
1/2"
Symbols
[1(P), 3(R) port] Applicable cable O.D.
Safety limit switch (made by OMRON)
Ø 3.5 to Ø 7
Part number: D4N-2B31 (G 1/2)
: D4N-9B31 (M12 connector)
Ø 5.2
(For mounting)
X536
G 1/2
88.8
81.3
(With check valve)
A
38.5
56.5
63
(34.7)
(22.9)
X538
(M12 connector) 31 128.9 (14)
9.4
224.8
1/2"
X555
X585
[2(A) port]
Port size: 1/8" (Without check valve)
44.5
Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
Ø 5.2 3.5 (External pilot port)
(For mounting) 7.5
Accessories
4.5
View A
Optional
For M12 connector
33
20.5 108.4
3.5
Pin
Specific Product
(Max. 10) 224.2 number
Precautions
VP742(R)-5 DY Z1-04$-S1$-X536
(43)
Safety limit switch (Distanc
e
between
Made by 1/2" ports)
[1(P), 3(R) port]
Rockwell Automation
VG342
40
9
Vent port 42
(Ø 6.2) 73.5 122.2
Applicable cable O.D.
Safety limit switch (made by Rockwell Automation) Ø 3.5 to Ø 7
Part number: 440P-CDPB03R6 Symbols
2 x Ø 5.2
(For mounting)
88.8
81.3
(With check valve)
X87
A
38.5
56.5
63
34.2
(22.9)
Specific Product
Precautions
239.1
1/2"
[2(A) port] Port size: 1/8" (Without check valve)
Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
2 x Ø 5.2 41 (External pilot port)
4.5
(For mounting)
7.5
View A
M12 connector
33
24
143.2 Pin
(Max. 10) number
238.5
8
VP-X538
VP544(R)-5 DY Z1-03$-$-X538
VP544(R)-5 DY Z1-03$-M$-X538
Safety limit switch
Made by View A
OMRON A
For M12 connector
104.8
79
Pin
34
number
Vent port
17.5
(Ø 6.2)
28.5 3/8"
(22.9) 57 [1(P) port]
(With check valve) 112 90.4 Port size: 1/8" (Without check valve)
2 x 3/8" Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
[3(R) port] (External pilot port)
47 5
G 1/2 2 x Ø 5.2 Applicable cable O.D.
(M12 connector) (For mounting) Ø 3.5 to Ø 7
Channel 2
75.5
91.5
33.5
62.5
Channel 1
29
29
18
17.5 (90.4) 11.3
8
28.2 (Max. 10) 201.8 (14) 97.3
(59.7)
17.5
3/8" 28.5
[2(A) port]
Safety limit switch (made by OMRON)
Part number: D4N-2B31 (G 1/2)
: D4N-9B31 (M12 connector)
9
3 Port Solenoid Valve/
VP-X538
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position
VP544(R)-5 DY Z1-03$-S1$-X538
VP500/700
Safety limit switch
Made by
Rockwell Automation
View A
M12 connector
A
104.8
79
Symbols
34
Pin
number
Vent port
17.5
(Ø 6.2)
28.5
X536
3/8"
(22.9) 57 [1(P) port]
(With check valve) 112 104.7
Port size: 1/8" (Without check valve)
Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
(External pilot port)
X538
2 x 3/8" 47 5 (104.7) 8
2 x Ø 5.2 Applicable cable O.D.
M12 connector [3(R) port]
(For mounting) Ø 3.5 to Ø 7
Channel 2
X555
X585
75.5
91.5
33.5
62.5
Channel 1
29
29
18
Accessories
17.5 (Max. 10) 216.1 11.3
Optional
28.2 97.3
59.2
17.5
3/8" 28.5
[2(A) port]
Specific Product
Precautions
Safety limit switch (made by Rockwell Automation)
Part number: 440P-CDPB03R6
VG342Symbols
X87
Specific Product
Precautions
10
VP-X538
VP744(R)-5 DY Z1-04$-$-X538
VP744(R)-5 DY Z1-04$-M$-X538
Safety limit switch
Made by
OMRON
View A
For M12 connector
124.8 A
99
Pin
number
36
18
Vent port 1/2"
(Ø 6.2) 40 [1(P) port]
(22.9) 80 88.9
(With check valve) 224.8
Port size: 1/8" (Without check valve)
2 x 1/2" Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
[3(R) port] (External pilot port)
2 x Ø 6.2 67 6.5
(M12 connector) G 1/2 Applicable cable O.D.
(For mounting)
Ø 3.5 to Ø 7
Channel 2
113.5
94.5
41.5
77.5
Channel 1
36
36
21
9.5
18 (88.9) 16
27.2 (Max. 10) 224.2 (14) 117.3
(70.7)
1/2" 40
[2(A) port]
18
11
3 Port Solenoid Valve/
VP-X538
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position
VP744(R)-5 DY Z1-04$-S1$-X538
VP500/700
Safety limit switch
Made by
Rockwell Automation View A
M12 connector
A
124.8
99
Symbols
Pin
36
number
18
Vent port 1/2"
(Ø 6.2) 40 [1(P) port]
X536
(22.9) 80
(With check valve) 135.9 103.2
Port size: 1/8" (Without check valve)
(103.2) Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
(External pilot port)
X538
2 x 1/2" 2 x Ø 6.2 67 6.5
M12 connector [3(R) port] (For mounting) Applicable cable O.D.
Ø 3.5 to Ø 7
Channel 2
X555
X585
113.5
94.5
41.5
77.5
Channel 1
Accessories
36
36
Optional
21
9.5
18 16
27.2 (Max. 10) 238.5 8 117.3
Specific Product
70.2
Precautions
1/2" 40
[2(A) port]
18
VG342Symbols
X87
Specific Product
Precautions
12
VP-X555, X585
Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555/X585)
VP544(R)-5 DY Z1-03$-$$-X555/X585
VP544(R)-5 DY Z1-03$-M$$-X555/X585
Safety limit switch
Made by
OMRON
101.3
75.5
30.5
24.2
(15)
15
Vent port 3/8"
(Ø 6.2) [1(P) port]
(22.9) 28.5 90.4
(With check valve) 202.4
33.5
109
125
96
62.5
62.5
35
15.5 Vent port (Variable throttle type) (90.4) 15
8
3/8" 28.5
[2(A) port]
Safety limit switch (made by OMRON)
(15)
15
A
View A
For M12 connector
Pin
number
13
3 Port Solenoid Valve/
VP-X555, X585
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position
Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555/X585
VP544(R)-5 DY Z1-03$-S1$$-X555/X585/X585
VP500/700
Safety limit switch
Made by
Rockwell Automation
101.3
75.5
Symbols
30.5
24.2
(15)
15
Vent port 3/8"
(Ø 6.2) [1(P) port]
X536
(22.9) 28.5 90.4
(With check valve) 216.7
X538
M12 connector 2 x 3/8" (External pilot port)
[3(R) port] 2 x Ø 5.2 Applicable cable O.D.
(For mounting) (Ø 3.5 to Ø 7)
X555
X585
33.5
109
125
96
62.5
62.5
Accessories
Optional
35
15.5 Vent port (Variable throttle type) (90.4) 15
8
Specific Product
Precautions
55.7
3/8" 28.5
[2(A) port]
VG342
Safety limit switch (made by Rockwell Automation)
(15)
15
A
View A
M12 connector
Symbols
Pin
number
X87
Specific Product
Precautions
14
VP-X555, X585
Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555/X585)
VP744(R)-5 DY Z1-04$-$$-X555/X585
VP744(R)-5 DY Z1-04$-M$$-X555/X585
Safety limit switch
Made by
OMRON
124.8
99
36
27.2
18
Vent port 1/2"
(Ø 6.2) [1(P) port]
(22.9) 40 88.9
(With check valve) 224.8
41.5
136
155
119
77.5
77.5
44.4
1/2" 40
[2(A) port]
18
A
View A
For M12 connector
Pin
number
15
3 Port Solenoid Valve/
VP-X555, X585
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position
Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555/X585)
VP744(R)-5 DY Z1-04$-S1$$-X555/X585
VP500/700
Safety limit switch
Made by
Rockwell Automation
124.8
Symbols
99
36
27.2
18
X536
Vent port 1/2"
(Ø 6.2) [1(P) port]
(22.9) 40 86.3
(With check valve) 245
Port size: 1/8" (Without check valve)
X538
Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
M12 connector 2 x 1/2" (External pilot port)
2 x Ø 6.2 67 6.5
[3(R) port] Applicable cable O.D.
(For mounting)
Ø 3.5 to Ø 7
X555
X585
41.5
Accessories
136
155
Optional
119
77.5
77.5
44.4
Specific Product
Precautions
18.5 Vent port 18
9.5
VG342
1/2" 40
[2(A) port]
18
A
View A
M12 connector
X87
Pin
Specific Product
Precautions
number
16
VP500/700-X538, X555, X585
Optional Accessories
Piping Adapter: 3/8, 1/2 Spacer with Bracket
A piping adapter allows installation/removal of the component D
without removing the piping and thus makes maintenance easier. K H
J F
Port size
G
Centre of
F.R.L.
Centre of
C
body
E
F.R.L.
body
B
D A
E
Part no. Note) Port size A B D
E300-$03-A 3/8 31.8 30 30
Seal
E400-$04-A 1/2 31.8 36 36
A
Note) $ in part numbers indicates a pipe thread type. (Spacer width)
No indication is necessary for Rc; however,
indicate N for NPT, and F for G. Part no. A B C D E F G H J K
∗ Separate interfaces are required for modular unit. Y300T-A 4.2 82 41 71.5 35 14 7 19 4 41
Y400T-A 5.2 96 48 86.1 40 18 9 26 5 50
(Max. 10)
82.9
82.9
IN OUT IN OUT
201.8
201.8
a b c a b c
(14)
(14)
d d
VP500/700
How to Use DIN Terminal Connector Light/Surge Voltage Suppressor
DIN Terminal
Caution With light (DZ)
Connection (YZ)
1. Loosen the holding screw and pull the connector out of the No.1
solenoid valve terminal block. (–)(+)
Symbols
2. After removing the holding screw, insert a flat blade
screwdriver etc. into the notch on the bottom of the terminal Varistor Coil
block and pry it open, separating the terminal block and the No.2
housing. (+)(–) LED
3. Loosen the screw (slotted screws) in the terminal block. Insert There is no polarity.
the lead core wires to the terminals according to the connection
X536
method, and secure the wires by re-tightening the terminal Note) Surge voltage suppressor of varistor has residual voltage
screw. corresponding to the protective element and rated voltage;
4. Secure the cord by fastening the ground nut. therefore, protect the controller side from the surge voltage.
Caution
X538
Limit Switch Cable
When making connections, please note that using other than the
supported size (Ø 3.5 to Ø 7) heavy-duty cord will not satisfy IP65 OMRON or Rockwell Automation M12 connector limit switch ca-
(enclosure) standards. Also, be sure to tighten the ground nut ble is available.
and holding screw within their specified torque ranges. M12 Connector Cable (4 Pins) Made by OMRON
X555
X585
Changing the entry direction Part number Cable length [mm]
ZS-37-L 300
After separating the terminal block and housing, the cord entry
can be changed by attaching the housing in the desired direction ZS-37-M 500
ZS-37-N 1000
Accessories
(4 directions at 90° intervals).
Optional
ZS-37-P 2000
∗ When equipped with a light, be careful not to damage the light
ZS-37-C 5000
with the cord’s lead wires.
Specific Product
Plug in and pull out the connector vertically without tilting to one Part number Cable length [mm]
Precautions
side. VP500-231-1 2000
Compatible cable
Cord O.D.: Ø 3.5 to Ø 7
(Reference) 0.5 mm2, 2-core or 3-core, equivalent to JIS C 3306 Installation
Use the external pilot type when using VP500/700-X536 or X538
with AV series. Install the AV series to the primary side.
VG342
Ground nut
Tightening torque
1.65 to 2.5 N·m
Holding screw
Tightening torque
Washer 0.4 N·m
Grommet
(Rubber) Housing
Symbols
Voltage symbol (Position for light
Type D: 24 V mounting)
Type Y: 24 VN
Terminal block
Terminal screw Notch
(3 locations)
X87
Tightening torque
0.2 to 0.25 N·m
Type “Y”
Specific Product
Precautions
18
Safety Standard ISO 13849-1 Certified
∗
How to Order
Made to Order
How to Order
Fill in according to How to Order above. Note) Electrical entry can be selected only for D type.
Check valve type is available only when the thread
Secondary battery compatible type is Rc.
19
3 Port Solenoid Valve/
VG342-X87
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position
Valve Specifications
VP500/700
Fluid Air
Type of actuation N.C. (Spring return)
Operation Internal pilot External pilot
Operating pressure range 0.25 to 0.7 MPa 0.25 to 0.7 MPa
0.25 to 0.7 MPa
External pilot pressure —
(Same as operating pressure)
Maximum operating frequency 30 times/minute
Minimum operating frequency 1 time/week
Symbols
Operating and ambient temperature −10 to 50 °C (No freezing)
Ambient humidity 95 %RH or less (No condensation)
Manual override None
Pilot exhaust Individual exhaust
X536
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance 150/50 m/s2
Enclosure IP40
Operating environment Indoors
X538
Weight 2.8 kg 2.9 kg
B10d (MTTFd calculation) 900000 times
X555
X585
Caution
Valve may not operate properly when air supply to P port is not adequate and the supply pressure
to the valve is lower than 0.25 MPa, the minimum operating pressure. Be careful with insufficient
supply pressure.
Accessories
Optional
Piping for External Pilot Type
Caution
The product may not operate when the external pilot pressure is insufficient due to simultaneous
Specific Product
operation or restricted air piping. In this case, use the check valve (AKH series) with the external
Precautions
pilot port, change the piping size or adjust the set pressure to provide a constant pressure of 0.25
MPa or more.
VG342
Flow rate characteristics
1!2 (P!A) 2!3 (A!R)
Series
C Q C Q
b Cv b Cv
[dm3/(s·bar)] [l/min (ANR)]∗ [dm3/(s·bar)] [l/min (ANR)]∗
VG342-X87 26.6 0.04 5.5 5864 28.6 0.03 5.6 6278
∗ These values have been calculated according to ISO 6358 and indicate the flow rate under standard Symbols
conditions with an inlet pressure of 0.6 MPa (relative pressure) and a pressure drop of 0.1 MPa
–15 % to +10 % of
Precautions
fluctuation rated voltage Min. applicable load 5 V DC, 1 mA (Load resistance) 5 V DC, 5 mA (Load resistance)
Power consumption 2.2 W Max. voltage 24 V DC
Suppressor Diode Max. load current 50 mA
Indicator LED Max. load inductance 0.5 H
Insulation voltage 300 V 600 V
Protection against electric shock Class II (EN 60947-5-1: 2004)
20
VG342-X87
Symbols
Safety limit switch
Made by
OMRON
VG342(R)-X87
Internal pilot External pilot External pilot/With check valve
2(A) 2(A) 2(A)
VG342(R)-X87
Internal pilot External pilot External pilot/With check valve
2(A) 2(A) 2(A)
21
3 Port Solenoid Valve/
VG342-X87
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position
VP500/700
VG342(R)-5DZ-06$-M$-X87
Safety limit switch
Made by
OMRON
Symbols
(External pilot port)
Channel 2 Channel 1 64.5
Safety limit switch (made by OMRON)
A 34
Part number: D4N-9B31
M12 x 1
Applicable cable O.D. Pg9
X536
Ø 4.5 to Ø 7
X538
(190.9: For external pilot)
Vent port (75) (48.2)
214.1
175.9
3 x Ø 8.5
(Mounting hole)
X555
X585
3 3 (Max. 3)
(106.6)
(27.7)
57.6
41.5
(69.5)
2 1
56
43.8
43.8
Accessories
(11.4)
Optional
28
21
37.5 73 73 10 37.5
3/4" 75 45.5 77
[1(P) port]
Specific Product
2 x 3/4" [3(R) port] 164.5 3/4"
Precautions
Should be normally open. [2(A) port]
75 42.3
34
VG342
74
View A
M12 connector
Symbols
Pin
number
X87
Specific Product
Precautions
22
VG342-X87
VG342(R)-5DZ-10$-M$-X87
Safety limit switch
Made by
OMRON
16.6
175.9
3 x Ø 8.5
(Mounting hole)
3 3 (Max. 3)
(106.6)
(27.7)
41.5
(69.5)
2 1
56
43.8
43.8
28
18.6
1" 75 43.5 30 (5) 77
[1(P) port] 2 x 1" [3(R) port] 30 160.5 1"
Should be normally open. 220.5 [2(A) port]
230.5
75 75.3
View A
M12 connector
34
74
Pin
number
23
3 Port Solenoid Valve/
VG342-X87
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position
VP500/700
VG342(R)-5DZ-06$-S1$-X87
Safety limit switch
Made by
Rockwell Automation
Symbols
(External pilot port)
Safety limit switch Channel 2 Channel 1 64.5
(made by Rockwell Automation) A 34
Part number: 440P-CDPB03R6 M12 x 1
Applicable cable O.D. Pg9
X536
Ø 4.5 to Ø 7
X538
(190.9: For external pilot)
Vent port (75) (48.2)
218.7
175.9
3 x Ø 8.5
X555
X585
(Mounting hole)
3 3 (Max. 3)
(106.6)
(27.7)
57.6
41.5
(69.5)
2 1
Accessories
56
43.8
43.8
Optional
(11.4)
28
21
37.5 73 73 10 37.5
3/4" 75 45.5 77
Specific Product
[1(P) port] 2 x 3/4" [3(R) port] 164.5
Precautions
3/4"
Should be normally open. [2(A) port]
75 42.3
34
VG342
74
View A
M12 connector
Symbols
Pin
number
X87
Specific Product
Precautions
24
VG342-X87
VG342(R)-5DZ-10$-S1$-X87
Safety limit switch
Made by
Rockwell Automation
(13.4)
190.9
3 x Ø 8.5
(Mounting hole)
3 3 (Max. 3)
(106.6)
(27.7)
41.5
(69.5)
N
2 1
56
43.8
43.8
28
37.5 73 73 38 37.5
18.6
1" 75 43.5 30 (5) 77
[1(P) port] 2 x 1" [3(R) port] 30 160.5 1"
Should be normally open. 220.5 [2(A) port]
230.5
75 75.3
View A
M12 connector
34
74
Pin
number
25
VG342-X87
Specific Product Precautions
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to the Operation Manual on the SMC
website, http://www.smc.eu
VP500/700
How to Use DIN Terminal Connector Light/Surge Voltage Suppressor
Symbols
2. After removing the holding screw, insert a flat blade (–)
screwdriver etc. into the notch on the bottom of the terminal
block and pry it open, separating the terminal block and the
housing.
3. Loosen the screw in the terminal block. Insert the lead core Limit Switch Cable
wires to the terminals, and secure the wires by re-tightening
X536
OMRON or Rockwell Automation M12 connector limit switch ca-
the terminal screw. ble is available.
As the product has polarity, referring to the electric circuit
diagram, wire the product correctly as per the symbol of the M12 Connector Cable (4 Pins) Made by OMRON
terminal No. of the terminal block. Part number Cable length [mm]
4. Secure the cord by fastening the ground nut.
X538
ZS-37-L 300
Tighten the ground nut and holding screw within the specified ZS-37-M 500
range of torque. ZS-37-N 1000
Changing the entry direction ZS-37-P 2000
ZS-37-C 5000
After separating the terminal block and housing, the cord entry
X555
X585
can be changed by attaching the housing in the opposite direction
180°. M12 Connector Cable (6 Pins) Made by Rockwell Automation
∗ Be careful not to damage the element etc. with the cord’s lead Part number Cable length [mm]
wires. VP500-231-1 2000
Accessories
Optional
Precautions
Plug in and pull out the connector vertically without tilting to one
side.
Specific Product
Compatible cable
Precautions
Cord O.D.: Ø 4.5 to Ø 7 (Reference) 0.5 to 1.5 mm2, 2-core or
3-core, equivalent to JIS C 3306
VG342
Ground nut
Holding screw
Tightening torque
2.5 to 3.75 N·m Tightening torque
0.5 to 0.6 N·m
Washer Housing
Grommet
(Rubber)
Symbols
Terminal block
Terminal number
Terminal screw
3 locations
X87
Tightening torque
0.4 to 0.5 N·m
Specific Product
Precautions
26
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with the
labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety
and must be followed in addition to International Standards (ISO/IEC)∗1), and other
safety regulations.
Caution indicates a hazard with a low level of risk ∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution: which, if not avoided, could result in minor or moderate
injury.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
Warning indicates a hazard with a medium level of risk (Part 1: General requirements)
Warning: which, if not avoided, could result in death or serious
injury.
ISO 10218-1: Manipulating industrial robots - Safety.
etc.
Danger indicates a hazard with a high level of risk
Danger : which, if not avoided, will result in death or serious injury.
Caution Caution
1. The product is provided for use in manufacturing industries. SMC products are not intended for use as instruments for legal
The product herein described is basically provided for peaceful use in manufacturing metrology.
industries. Measurement instruments that SMC manufactures or sells have not been qualified by
If considering using the product in other industries, consult SMC beforehand and exchange type approval tests relevant to the metrology (measurement) laws of each country.
specifications or a contract if necessary. Therefore, SMC products cannot be used for business or certification ordained by the
If anything is unclear, contact your nearest sales branch. metrology (measurement) laws of each country.
Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.
SMC Corporation (Europe)
Austria +43 (0)2262622800 www.smc.at office@smc.at Lithuania +370 5 2308118 www.smclt.lt info@smclt.lt
Belgium +32 (0)33551464 www.smcpneumatics.be info@smcpneumatics.be Netherlands +31 (0)205318888 www.smcpneumatics.nl info@smcpneumatics.nl
Bulgaria +359 (0)2807670 www.smc.bg office@smc.bg Norway +47 67129020 www.smc-norge.no post@smc-norge.no
Croatia +385 (0)13707288 www.smc.hr office@smc.hr Poland +48 222119600 www.smc.pl office@smc.pl
Czech Republic +420 541424611 www.smc.cz office@smc.cz Portugal +351 226166570 www.smc.eu postpt@smc.smces.es
Denmark +45 70252900 www.smcdk.com smc@smcdk.com Romania +40 213205111 www.smcromania.ro smcromania@smcromania.ro
Estonia +372 6510370 www.smcpneumatics.ee smc@smcpneumatics.ee Russia +7 8127185445 www.smc-pneumatik.ru info@smc-pneumatik.ru
Finland +358 207513513 www.smc.fi smcfi@smc.fi Slovakia +421 (0)413213212 www.smc.sk office@smc.sk
France +33 (0)164761000 www.smc-france.fr info@smc-france.fr Slovenia +386 (0)73885412 www.smc.si office@smc.si
Germany +49 (0)61034020 www.smc.de info@smc.de Spain +34 902184100 www.smc.eu post@smc.smces.es
Greece +30 210 2717265 www.smchellas.gr sales@smchellas.gr Sweden +46 (0)86031200 www.smc.nu post@smc.nu
Hungary +36 23511390 www.smc.hu office@smc.hu Switzerland +41 (0)523963131 www.smc.ch info@smc.ch
Ireland +353 (0)14039000 www.smcpneumatics.ie sales@smcpneumatics.ie Turkey +90 212 489 0 440 www.smcpnomatik.com.tr info@smcpnomatik.com.tr
Italy +39 0292711 www.smcitalia.it mailbox@smcitalia.it UK +44 (0)845 121 5122 www.smcpneumatics.co.uk sales@smcpneumatics.co.uk
Latvia +371 67817700 www.smclv.lv info@smclv.lv
SMC CORPORATION Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362
1st printing TT printing TU 00 Printed in Spain Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.