Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

Safety Standard ISO 13849-1 Certified∗2(Corresponding to Category 2 to 4) New ® ∗1

3 Port Solenoid Valve/ ∗1. Refer to page 2 for


compliant products.

Residual Pressure Release Valve RoHS


with Detection of Main Valve Position ∗2. Refer to page 2 for certified products.

With Detection of
Residual pressure
release valve

Main Valve Position


Category 2

The detecting function of the main valve position detects a Safety limit switch
mismatch between the input signal and valve operation.
VP542-X536/VP742-X536

Redundant system can be When the dual residual pressure release valve is
used, if one of the valves fails to operate, the
constructed easily. other one releases residual pressure.
Category 3, 4
With Soft Start-up Function
Dual Residual Pressure Release Valve VP544-X555/VP744-X555 (0.7 MPa) Dual Residual Pressure Release Valve
VP544-X538/VP744-X538 VP544-X585/VP744-X585 (1.0 MPa) VG342-X87
Residual pressure Residual pressure
release valve w release valve w
Residual pressure
Residual pressure
release valve q
release valve q

Safety limit
switch
Soft start-up
valve

Redundant System
A system in which even if one part fails, the whole system
will fulfill its required function. This is usually achieved by
having dual channels of operation, such as dual valves, dual
wiring, dual guard switches etc.

SeriesVP/VG
CAT.EUS11-111Aa-UK
Safety Standard ISO 13849-1 Certified
3 Port Solenoid Valve/Residual Pressure Release Valve with Detection of Main Valve Position Series VP/VG

With Detection of Main Valve Position (Category 2) Redundant system can be constructed easily. (Category 3, 4)
Category 2 Safety function can be accomplished by single channel and is automatically Category 3 It has redundancy so there is no loss of safety function with a single failure.
checked. The safety function must be checked before each use. An accumulation of
undetected faults can cause loss of safety function.
Category 4 It has redundancy so there is no loss of safety function with a single failure. The
safety function must be checked before each use. An accumulation of undetected
faults does not affect the safety function. (Higher DC and MTTFd than Category 3.)

Monitoring
I Input signal L O I1 Input signal L1 O1
Logical operation Logical operation
Input equipment Output signal Output equipment Input equipment Output equipment
equipment equipment Output signal
Monitoring
Cross monitoring
Monitoring
TE OTE I2 Input signal L2 O2
Logical operation
Testing equipment Output signal Output of test result Input equipment Output equipment
equipment Output signal

The detecting function of the main valve position detects a When the dual residual pressure release valve is used, if one of the
mismatch between the input signal and valve operation. valves fails to operate, the other one releases residual pressure.
Input equipment (I) : Detection equipment (sensor) of starting event Input equipment (I1, I2): Detection equipment (sensor) of starting event
Logical operation equipment (L) : Relay sequence circuit, PLC control program Logical operation equipment (L1, L2): Relay sequence circuit, PLC control program
Output equipment (O) : Solenoid valve, Electromagnetic switch, Output relay Output equipment (O1, O2): Solenoid valve, Electromagnetic switch, Output relay
Recommended valve : VP542/742-X536 Recommended valve: VP544/744-X538, VG342-X87

Residual pressure release valve Residual pressure release valve w

Safety limit Safety limit


switch switch
Residual pressure
release valve q
VP542-X536 VP544-X538
∗ This product is component which is a part of a safety system and safety equipment is not guaranteed by this single unit alone.

Highly reliable construction Safety limit switch can be selected.


q The main valve position is detected by transferring the
main valve movement directly to the reed safety limit switch
with the rod.

Main valve Rod


Safety limit switch

Made by OMRON Made by Rockwell Automation

Conduit (VP series only) and M12 connector with 6 pins is


M12 connector (4 pin) types available.
w Long service life: B10d: 10 million times∗
are available.
e The return spring releases the residual pressure securely
regardless of pressure level.
∗ For VP"-X536/X538/X555, safety limit switch made by OMRON

With soft start-up function (-X555/X585)


! A function to gradually increase the initial pressure Output Pressure (P2) vs Time Graph
of the pneumatic system has been added to the dual
residual pressure release valve. P1
! Fixed orifice and variable throttle are available as a throttle P2 reaches half of P1, and
then the main valve of the
for adjusting the pressure increase. (Ø 1, Ø 1.5, Ø 2) soft start-up valve turns on.
Output pressure P2

Throttle Main valve Valve 1 Valve 2


Soft start-up valve: ON
P2 Valve 1, Valve 2: ON
1/2P1
Soft start-up 1(P) Start supplying flow ad-
2(A) justed air with the throt-
valve tle by energising valve
1 and valve 2.
VP544-X555 P1 Soft start-up valve: OFF
VP544-X585 Valve 1, Valve 2: ON
Soft start-up
valve 0
Time
3(R) 3(R)

1
Safety Standard ISO 13849-1 Certified
3 Port Solenoid Valve/Residual Pressure Release Valve with Detection of Main Valve Position Series VP/VG

Standards and Enclosure


Standards
Safety limit switch Machinery Directive 2006/42/EC
Series Category
manufacturer
Enclosure
Harmonised EN ISO 13849-1: 2008 EN ISO 4414: CE cUL RoHS
standards EN ISO 13849-2: 2008 2010
Residual Pressure OMRON Corporation
Release Valve 2 IP65
VP542/742-X536 Page 3 Rockwell Automation, Inc.

Dual Residual Pressure OMRON Corporation


Release Valve 3, 4 IP65
VP544/744-X538 Page 3 Rockwell Automation, Inc.

Dual Residual Pressure Release Valve


OMRON Corporation
with Soft Start-up Function
3, 4 IP65
VP544/744-X555
Page 3 Rockwell Automation, Inc.
VP544/744-X585

Dual Residual Pressure OMRON Corporation
Release Valve 3, 4 IP40
VG342-X87 Page 19 Rockwell Automation, Inc.

∗ Only port size 3/4"

Series Variations
Flow rate characteristics
Port C [dm3/(s·bar)]/Q [l/min (ANR)]∗ 1!2 (P!A)
Series Category Thread
size
5 10 15 20 25
Residual Pressure
Release Valve 3/8"
Rc,
8.9/2085
VP542-X536
2 G,
Residual Pressure NPT
Release Valve 1/2" 15.1/3637
VP742-X536
Dual Residual Pressure
Release Valve 3/8" 6.5/1461
VP544-X538 Rc,
G,
Dual Residual Pressure NPT
Release Valve 1/2" 10.3/2315
VP744-X538
Dual Residual Pressure Release
Valve with Soft Start-up Function 3, 4 3/8"
Rc,
5.2/1157
VP544-X555/VP544-X585
85
G,
Dual Residual Pressure Release NPT
Valve with Soft Start-up Function 1/2" 9.8/2203
VP744-X555/ VP744-X585
X585
Dual Residual Pressure
ure Rc, 2
26.6/
Release Valve 3/4" G,
VG342-X87 NPT 55864
∗ These values have been calculated according to ISO 6358 and indicate the flow rate under standard conditions with an inlet pressure of 0.6 MPa (relative pressure)
and a pressure drop of 0.1 MPa

Can be connected to Modular type


For details about Safety Standard
F.R.L. units. Page 17 ISO 13849-1, refer to “machinery
Applicable models∗ directive 2006/421EC. Safety
control system standard EN ISO
#VP544/744-X538
13849-1” on the SMC website
#VP544/744-X555 ∗ Please contact SMC for the www.smc.eu.
#VP544/744-X585 VP542/742-X536.

Filter regulator Dual residual pressure


(Optional release valve with soft
accessory) start-up function

2
Safety Standard ISO 13849-1 Certified

3 Port Solenoid Valve/Residual Pressure Release ∗ Refer to page 2 for


compliant products.

Valve with Detection of Main Valve Position


VP-X536, X538, X555, X585
How to Order

Residual pressure release valve VP 5 4 2 R 5 D Z 1 03 F M X536

Dual residual pressure release valve VP 5 4 4 R 5 D Z 1 03 F M X538

Dual residual pressure release


valve with soft start-up function VP 5 4 4 5 D Z 1 03 F M X555
Maximum operating
Series
pressure
5 VP500
Body Thread X555 0.7 MPa
7 VP700
2 Body ported — Rc X585 1.0 MPa
4 Base mounted F G
Throttle
N NPT
— Variable throttle
Pilot 10 Ø 1 fixed orifice
Internal pilot 15 Ø 1.5 fixed orifice
Voltage
R External pilot 20∗ Ø 2 fixed orifice
5 24 V DC
∗ VP700 only

Electrical entry
Safety limit switch/Wiring
D DIN terminal
— G 1/2 (Made by OMRON)
Y DIN (EN 175301-803) terminal
M M12 connector (Made by OMRON)
∗ Refer to page 18 for details about type Y.
M12 connector
S1 (Made by Rockwell Automation)
Light/surge voltage suppressor
Z With light/surge voltage suppressor With check valve (Only external pilot)
Check Applicable Thread
valve tube O.D. Rc G NPT
Port size
Port size VP500 VP700 — None — ! ! !
03 3/8" ! — A Ø6 ! — —
Yes
04 1/2" — ! B Ø 1/4∗ — — !
∗ For internal pilot, the symbol is nil.
∗ Refer to “Piping for External Pilot Type” on page 4 for
selection of the check valve.
Made to Order

1 Series Compatible with Secondary Batteries


For details about 25A-, please consult SMC.

How to Order X536


25A–VP" 4 "" – 5DZ1 – """ – """ – X538
X555
Fill in according to How to Order above. Note) Electrical entry can be selected only for D type.
Check valve type is available only when the thread
Secondary battery compatible type is Rc.
3
3 Port Solenoid Valve/
VP-X536, X538, X555, X585
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position

Valve Specifications

VP500/700
VP"42-X536 VP"42R-X536
Model VP"44-X538 VP"44R-X538 VP"44-X585 VP"44R-X585
VP"44-X555 VP"44R-X555
Fluid Air
Type of actuation N.C. (Spring return)
Operation Internal pilot External pilot Internal pilot External pilot
Operating pressure range 0.25 to 0.7 MPa 0.25 to 1.0 MPa
External pilot pressure — 0.25 to 0.7 MPa (Same as operating pressure)
Maximum operating frequency 30 times/minute
Minimum operating frequency 1 time/week
Operating and ambient temperature -10 to 50 °C (No freezing)

Symbols
Ambient humidity 20 to 90 %RH (No condensation)
Manual override None
Pilot exhaust Individual exhaust
Lubrication Not required
Mounting orientation Unrestricted

X536
Impact/Vibration resistance 150/30 m/s2
Enclosure IP65
Operating environment Indoors
10000000 times (for the safety limit switch made by OMRON)
B10d (MTTFd calculation) 1000000 times
1000000 times (for the safety limit switch made by Rockwell Automation)

X538
Internal Pilot Type Piping for External Pilot Type
Caution Caution
Valve may not operate properly when air sup- The product may not operate when the external pilot
ply to P port is not adequate and the supply pressure is insufficient due to simultaneous opera-

X555
X585
pressure to the valve is lower than 0.25 MPa, tion or restricted air piping. In this case, use the
the minimum operating pressure. Be careful check valve (AKH series) with the external pilot port,
with insufficient supply pressure. change the piping size or adjust the set pressure to
provide a constant pressure of 0.25 MPa or more.

Accessories
Flow Rate Characteristics / Weight

Optional
Flow rate characteristics
Weight
Series 1!2 (P!A) 2!3 (A!R)
∗ ∗ [g]
C [dm /(s·bar)] b
3
Cv Q [l/min (ANR)] C [dm /(s·bar)] b
3
Cv Q [l/min (ANR)]

Specific Product
Precautions
VP542-X536 8.9 0.16 2.2 2085 8.9 0.20 2.1 2132 350
VP742-X536 15.1 0.21 3.6 3637 15.3 0.22 3.7 3707 590
VP544-X538 6.5 0.08 1.3 1461 6.7 0.10 1.3 1521 930
VP744-X538 10.3 0.08 2.3 2315 9.7 0.08 2.1 2180 1510
VP544-X555
5.2 0.06 1.1 1157 6.7 0.10 1.3 1521 1105
VP544-X585
VP744-X555
9.8 0.08 2.1 2203 9.7 0.08 2.1 2180 2000

VG342
VP744-X585
∗ These values have been calculated according to ISO 6358 and indicate the flow rate under standard
conditions with an inlet pressure of 0.6 MPa (relative pressure) and a pressure drop of 0.1 MPa

Needle Valve / Flow Rate Characteristics (VP544/744-X555)


600
Ø 1 Ø 1.5 Ø2 Symbols
Flow rate [l/min (ANR)]

500
0.7 MPa
400
0.5 MPa
300
0.25 MPa
X87

200

100

0
0 0.5 1 1.5 2 2.5 3 3.5 4
Specific Product
Precautions

Number of needle rotations (Turns)

Solenoid Specifications Safety Limit Switch Specifications


Electrical entry DIN terminal Manufacturer OMRON Rockwell Automation
Rated voltage 24 V DC Electrical wiring G 1/2, M12 connector M12 connector
Allowable voltage fluctuation ±10 % Contact resistance 25 mΩ or less 50 mΩ or less
Power consumption 0.45 W Min. applicable load 5 V DC, 1 mA (Load resistance) 5 V DC, 5 mA (Load resistance)
Surge voltage suppressor Varistor Max. voltage 24 V DC
Indicator LED Max. load current 50 mA
Max. load inductance 0.5 H
Insulation voltage 300 V 600 V
Protection against electric shock Class II (EN60947-5-1: 2004)
4
VP-X536, X538, X555, X585

Symbols
Safety limit switch
Made by
OMRON

Symbol Terminal/Pin Numbers (Built-in switch 2N.C.)


M12 connector G 1/2
(12) (32) Wiring specification Wiring specification
pin number terminal number

q (11)
11 12
w (12)

(11) (31) e (31) 31 32

r (32)

VP542(R) /742(R)-X536
Internal pilot External pilot External pilot/With check valve
w r w r w r
2(A) (12) (32) 2(A) (12) (32) 2(A) (12) (32)

1(P) 3(R) (11) (31) 1(P) 3(R) (11) (31) 1(P) 3(R) (11) (31)
q e q e q e

Safety limit switch terminal [N.C.] X X


M12 connector pin number
G 1/2 terminal number

VP544(R) /744(R)-X538
Internal pilot External pilot External pilot/With check valve
w r w r w r
2(A) (12) (32) 2(A) (12) (32) 2(A) (12) (32)

3(R) (11) (31) 3(R) (11) (31) 3(R) (11) (31)


q e q e q e
w r w r w r
(12) (32) (12) (32) (12) (32)

3(R) (11) (31) 3(R) (11) (31) 3(R) (11) (31)


q e q e q e

1(P) X 1(P) 1(P)


X

VP544(R) /744(R)-X555
VP544(R) /744(R)-X585
Internal pilot External pilot External pilot/With check valve
2(A) 2(A) 2(A)

w r w r w r
(12) (32) (12) (32) (12) (32)

(11) (31) (11) (31) (11) (31)


q e q e q e
3(R) 3(R) 3(R)
w r w r w r
(12) (32) (12) (32) (12) (32)

(11) (31) (11) (31) (11) (31)


q e q e q e
3(R) 3(R) 3(R)

1(P) X 1(P) X 1(P)

5
3 Port Solenoid Valve/
VP-X536, X538, X555, X585
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position

Symbols

VP500/700
Safety limit switch
Made by
Rockwell Automation

Symbol Pin Numbers (Built-in switch 3N.C.)


M12 connector
Wiring specification
pin number

Symbols
q
t
w
y

X536
e
r

X538
VP542(R)/742(R)-X536
Internal pilot External pilot External pilot/With check valve
2(A) tyr 2(A) tyr 2(A) tyr

X555
X585
1(P) 3(R) qwe 1(P) 3(R) qwe 1(P) 3(R) qwe

Accessories
Safety limit switch terminal [N.C.] X X

Optional
M12 connector pin number

VP544(R)/744(R)-X538

Specific Product
Internal pilot External pilot External pilot/With check valve

Precautions
2(A) tyr 2(A) tyr 2(A) tyr

3(R) qwe 3(R) qwe 3(R) qwe

tyr tyr tyr

VG342
3(R) qwe 3(R) qwe 3(R) qwe

1(P) X 1(P) X 1(P)

VP544(R) /744(R)-X555 Symbols


VP544(R) /744(R)-X585
Internal pilot External pilot External pilot/With check valve
2(A) 2(A) 2(A)

tyr tyr tyr


X87

qwe qwe qwe


3(R) 3(R) 3(R)
Specific Product

tyr tyr tyr


Precautions

qwe qwe qwe


3(R) 3(R) 3(R)

1(P) X 1(P) X 1(P)

6
VP-X536

Dimensions Residual Pressure Release Valve (-X536)

VP542(R)-5 DY Z1-03$-$-X536
VP542(R)-5 DY Z1-03$-M$-X536
(31.5
)
Safety limit switch (Distan
ce b
etween
Made by 3/8" ports)
OMRON 32
[1(P), 3(R) port]

Vent port 30.7


(Ø 6.2) 54.9 103.4
Applicable cable O.D.
Safety limit switch (made by OMRON) Ø 3.5 to Ø 7
Part number: D4N-2B31 (G 1/2)
: D4N-9B31 (M12 connector)
2 x Ø 4.2
(25.7)

G 1/2 (For mounting)

70.8
63.3
(With check valve)
A
31.5

45
40

(22.9)
23.5 117.4
4

(M12 connector) 202.4 (14)

3/8"
Port size: 1/8" (Without check valve)
[2(A) port]
Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
2 x Ø 4.2 31 (External pilot port)
3.5

(For mounting)
4.5

View A
26

For M12 connector

22.1
118.9 Pin
(Max. 10) 201.8 number

VP542(R)-5 DY Z1-03$-S1$-X536
(31.5
Safety limit switch )
(Distan
ce between
Made by 3/8" ports)
Rockwell Automation [1(P), 3(R) port]
32
7

Vent port 30.7


(Ø 6.2) 54.9 117.7
Applicable cable O.D.
Safety limit switch (made by Rockwell Automation) Ø 3.5 to Ø 7
Part number: 440P-CDPB03R6

2 x Ø 4.2
(For mounting)
70.8
63.3
(With check valve)

A
31.5

45
40
25.2

(22.9)

M12 connector 23.5 131.7


4

216.7 8

3/8"
Port size: 1/8" (Without check valve)
[2(A) port]
Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
2 x Ø 4.2 31 (External pilot port)
3.5

(For mounting)
4.5

View A
M12 connector
26

22.1
133.2 Pin
(Max. 10) 216.1 number

7
3 Port Solenoid Valve/
VP-X536
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position

Dimensions Residual Pressure Release Valve (-X536)

VP742(R)-5 DY Z1-04$-$-X536

VP500/700
VP742(R)-5 DY Z1-04$-M$-X536 (43) (D
istance
between
ports)
Safety limit switch
Made by 40
9
OMRON
Vent port 42
(Ø 6.2) 73.5 107.9
1/2"

Symbols
[1(P), 3(R) port] Applicable cable O.D.
Safety limit switch (made by OMRON)
Ø 3.5 to Ø 7
Part number: D4N-2B31 (G 1/2)
: D4N-9B31 (M12 connector)
Ø 5.2
(For mounting)

X536
G 1/2

88.8
81.3
(With check valve)
A
38.5

56.5
63
(34.7)

(22.9)

X538
(M12 connector) 31 128.9 (14)
9.4

224.8

1/2"

X555
X585
[2(A) port]
Port size: 1/8" (Without check valve)
44.5
Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
Ø 5.2 3.5 (External pilot port)
(For mounting) 7.5

Accessories
4.5

View A

Optional
For M12 connector
33

20.5 108.4
3.5

Pin

Specific Product
(Max. 10) 224.2 number

Precautions
VP742(R)-5 DY Z1-04$-S1$-X536
(43)
Safety limit switch (Distanc
e
between
Made by 1/2" ports)
[1(P), 3(R) port]
Rockwell Automation

VG342
40
9

Vent port 42
(Ø 6.2) 73.5 122.2
Applicable cable O.D.
Safety limit switch (made by Rockwell Automation) Ø 3.5 to Ø 7
Part number: 440P-CDPB03R6 Symbols
2 x Ø 5.2
(For mounting)
88.8
81.3
(With check valve)

X87

A
38.5

56.5
63
34.2

(22.9)

M12 connector 31 143.2 8


9.4

Specific Product
Precautions

239.1

1/2"
[2(A) port] Port size: 1/8" (Without check valve)
Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
2 x Ø 5.2 41 (External pilot port)
4.5

(For mounting)
7.5

View A
M12 connector
33

24
143.2 Pin
(Max. 10) number
238.5

8
VP-X538

Dimensions Dual Residual Pressure Release Valve (-X538)

VP544(R)-5 DY Z1-03$-$-X538
VP544(R)-5 DY Z1-03$-M$-X538
Safety limit switch
Made by View A
OMRON A
For M12 connector

104.8
79
Pin

34
number

Vent port

17.5
(Ø 6.2)
28.5 3/8"
(22.9) 57 [1(P) port]
(With check valve) 112 90.4 Port size: 1/8" (Without check valve)
2 x 3/8" Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
[3(R) port] (External pilot port)
47 5
G 1/2 2 x Ø 5.2 Applicable cable O.D.
(M12 connector) (For mounting) Ø 3.5 to Ø 7

Channel 2

75.5
91.5

33.5
62.5

Channel 1
29

29
18
17.5 (90.4) 11.3

8
28.2 (Max. 10) 201.8 (14) 97.3
(59.7)
17.5

3/8" 28.5
[2(A) port]
Safety limit switch (made by OMRON)
Part number: D4N-2B31 (G 1/2)
: D4N-9B31 (M12 connector)

9
3 Port Solenoid Valve/
VP-X538
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position

Dimensions Dual Residual Pressure Release Valve (-X538)

VP544(R)-5 DY Z1-03$-S1$-X538

VP500/700
Safety limit switch
Made by
Rockwell Automation
View A
M12 connector
A
104.8
79

Symbols
34
Pin
number
Vent port

17.5
(Ø 6.2)
28.5

X536
3/8"
(22.9) 57 [1(P) port]
(With check valve) 112 104.7
Port size: 1/8" (Without check valve)
Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
(External pilot port)

X538
2 x 3/8" 47 5 (104.7) 8
2 x Ø 5.2 Applicable cable O.D.
M12 connector [3(R) port]
(For mounting) Ø 3.5 to Ø 7

Channel 2

X555
X585
75.5
91.5

33.5
62.5

Channel 1
29

29
18

Accessories
17.5 (Max. 10) 216.1 11.3

Optional
28.2 97.3
59.2
17.5

3/8" 28.5
[2(A) port]

Specific Product
Precautions
Safety limit switch (made by Rockwell Automation)
Part number: 440P-CDPB03R6

VG342Symbols
X87
Specific Product
Precautions

10
VP-X538

Dimensions Dual Residual Pressure Release Valve (-X538)

VP744(R)-5 DY Z1-04$-$-X538
VP744(R)-5 DY Z1-04$-M$-X538
Safety limit switch
Made by
OMRON
View A
For M12 connector
124.8 A

99
Pin
number

36
18
Vent port 1/2"
(Ø 6.2) 40 [1(P) port]
(22.9) 80 88.9
(With check valve) 224.8
Port size: 1/8" (Without check valve)
2 x 1/2" Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
[3(R) port] (External pilot port)
2 x Ø 6.2 67 6.5
(M12 connector) G 1/2 Applicable cable O.D.
(For mounting)
Ø 3.5 to Ø 7

Channel 2

113.5
94.5

41.5
77.5

Channel 1
36

36
21
9.5

18 (88.9) 16
27.2 (Max. 10) 224.2 (14) 117.3
(70.7)
1/2" 40
[2(A) port]
18

Safety limit switch (made by OMRON)


Part number: D4N-2B31 (G 1/2)
: D4N-9B31 (M12 connector)

11
3 Port Solenoid Valve/
VP-X538
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position

Dimensions Dual Residual Pressure Release Valve (-X538)

VP744(R)-5 DY Z1-04$-S1$-X538

VP500/700
Safety limit switch
Made by
Rockwell Automation View A
M12 connector
A

124.8

99

Symbols
Pin

36
number

18
Vent port 1/2"
(Ø 6.2) 40 [1(P) port]

X536
(22.9) 80
(With check valve) 135.9 103.2
Port size: 1/8" (Without check valve)
(103.2) Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
(External pilot port)

X538
2 x 1/2" 2 x Ø 6.2 67 6.5
M12 connector [3(R) port] (For mounting) Applicable cable O.D.
Ø 3.5 to Ø 7

Channel 2

X555
X585
113.5
94.5

41.5
77.5

Channel 1

Accessories
36

36

Optional
21
9.5
18 16
27.2 (Max. 10) 238.5 8 117.3

Specific Product
70.2

Precautions
1/2" 40
[2(A) port]
18

Safety limit switch (made by Rockwell Automation)


Part number: 440P-CDPB03R6

VG342Symbols
X87
Specific Product
Precautions

12
VP-X555, X585

Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555/X585)

VP544(R)-5 DY Z1-03$-$$-X555/X585
VP544(R)-5 DY Z1-03$-M$$-X555/X585
Safety limit switch
Made by
OMRON
101.3
75.5

30.5
24.2
(15)

15
Vent port 3/8"
(Ø 6.2) [1(P) port]
(22.9) 28.5 90.4
(With check valve) 202.4

Port size: 1/8" (Without check valve)


(M12 connector) 2 x 3/8" Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
[3(R) port] (External pilot port)
47 5
G 12 2 x Ø 5.2 Applicable cable O.D.
(For mounting) (Ø 3.5 to Ø 7)

33.5
109
125
96
62.5

62.5
35
15.5 Vent port (Variable throttle type) (90.4) 15
8

24.2 (Ø 6.4) (Max. 10) 201.8 (14) 93.8


56.2

3/8" 28.5
[2(A) port]
Safety limit switch (made by OMRON)
(15)

15

Part number: D4N-2B31 (G 1/2)


: D4N-9B31 (M12 connector)

A
View A
For M12 connector

Pin
number

13
3 Port Solenoid Valve/
VP-X555, X585
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position

Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555/X585

VP544(R)-5 DY Z1-03$-S1$$-X555/X585/X585

VP500/700
Safety limit switch
Made by
Rockwell Automation

101.3
75.5

Symbols
30.5
24.2
(15)

15
Vent port 3/8"
(Ø 6.2) [1(P) port]

X536
(22.9) 28.5 90.4
(With check valve) 216.7

Port size: 1/8" (Without check valve)


Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)

X538
M12 connector 2 x 3/8" (External pilot port)
[3(R) port] 2 x Ø 5.2 Applicable cable O.D.
(For mounting) (Ø 3.5 to Ø 7)

X555
X585
33.5
109
125
96
62.5

62.5

Accessories
Optional
35
15.5 Vent port (Variable throttle type) (90.4) 15
8

24.2 (Ø 6.4) (Max. 10) 216.1 8 93.8

Specific Product
Precautions
55.7

3/8" 28.5
[2(A) port]

VG342
Safety limit switch (made by Rockwell Automation)
(15)

15

Part number: 440P-CDPB03R6

A
View A
M12 connector
Symbols

Pin
number
X87
Specific Product
Precautions

14
VP-X555, X585

Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555/X585)

VP744(R)-5 DY Z1-04$-$$-X555/X585
VP744(R)-5 DY Z1-04$-M$$-X555/X585
Safety limit switch
Made by
OMRON
124.8
99

36
27.2
18
Vent port 1/2"
(Ø 6.2) [1(P) port]
(22.9) 40 88.9
(With check valve) 224.8

Port size: 1/8" (Without check valve)


2 x 1/2" Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
(M12 connector)
[3(R) port] 67 6.5 (External pilot port)
2 x Ø 6.2
G 1/2 (For mounting) Applicable cable O.D.
Ø 3.5 to Ø 7

41.5
136
155
119
77.5

77.5
44.4

18.5 Vent port 18


9.5

27.2 (Ø 6.4) (Variable throttle type) (88.9) 117.3


70.7 (Max. 10) 224.2 (14)

1/2" 40
[2(A) port]
18

Safety limit switch (made by OMRON)


Part number: D4N-2B31 (G 1/2)
: D4N-9B31 (M12 connector)

A
View A
For M12 connector

Pin
number

15
3 Port Solenoid Valve/
VP-X555, X585
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position

Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555/X585)

VP744(R)-5 DY Z1-04$-S1$$-X555/X585

VP500/700
Safety limit switch
Made by
Rockwell Automation
124.8

Symbols
99

36
27.2
18

X536
Vent port 1/2"
(Ø 6.2) [1(P) port]
(22.9) 40 86.3
(With check valve) 245
Port size: 1/8" (Without check valve)

X538
Applicable tube O.D.: Ø 6, Ø 1/4" (With check valve)
M12 connector 2 x 1/2" (External pilot port)
2 x Ø 6.2 67 6.5
[3(R) port] Applicable cable O.D.
(For mounting)
Ø 3.5 to Ø 7

X555
X585
41.5

Accessories
136
155

Optional
119
77.5

77.5
44.4

Specific Product
Precautions
18.5 Vent port 18
9.5

27.2 (Ø 6.4) (Variable throttle type) (86.3) 117.3


70.2 (Max. 10) 236.4 8

VG342
1/2" 40
[2(A) port]
18

Safety limit switch (made by Rockwell Automation)


Part number: 440P-CDPB03R6
Symbols

A
View A
M12 connector
X87

Pin
Specific Product
Precautions

number

16
VP500/700-X538, X555, X585
Optional Accessories
Piping Adapter: 3/8, 1/2 Spacer with Bracket
A piping adapter allows installation/removal of the component D
without removing the piping and thus makes maintenance easier. K H
J F
Port size

G
Centre of
F.R.L.
Centre of

C
body

E
F.R.L.
body

B
D A

E
Part no. Note) Port size A B D
E300-$03-A 3/8 31.8 30 30
Seal
E400-$04-A 1/2 31.8 36 36
A
Note) $ in part numbers indicates a pipe thread type. (Spacer width)
No indication is necessary for Rc; however,
indicate N for NPT, and F for G. Part no. A B C D E F G H J K
∗ Separate interfaces are required for modular unit. Y300T-A 4.2 82 41 71.5 35 14 7 19 4 41
Y400T-A 5.2 96 48 86.1 40 18 9 26 5 50

Ordering Example∗ Dual residual pressure release valve


with soft start-up function
VP544-5DZ1-03-X538 ······· 1 pc.
Filter regulator
AW30-03G-B ····················· 1 pc.
Spacer with bracket
Spacer with bracket
Y300T-A ···························· 3 pcs.
Piping adapter
E300-03-A ························· 2 pcs.

∗ Each product is not assembled.


Piping
adapter

Spacer with Bracket Mounting Position


Dual residual pressure release valve (-X538) Dual residual pressure release valve with soft start-up
function (-X555/X585)
(Max. 10)

(Max. 10)
82.9

82.9

IN OUT IN OUT
201.8

201.8

a b c a b c
(14)

(14)

d d

Model a b c d Note Model a b c d Note


AW30-03G-B AW30-03G-B
VP544-5DZ1-03-X555
VP544-5DZ1-03-X538 33.9 57.2 95.7 220.7 Y300T-A 33.9 57.2 129.2 254.2 Y300T-A
E300-03-A VP544-5DZ1-03-X585 E300-03-A
AW40-04G-B AW40-04G-B
VP744-5DZ1-04-X555
VP744-5DZ1-04-X538 34.4 75.2 118.7 262.7 Y400T-A 34.4 75.2 160.2 304.2 Y400T-A
E400-04-A VP744-5DZ1-04-X585 E400-04-A
17
VP500/700-X536, X538, X555, X585
Specific Product Precautions
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to the Operation Manual on the SMC
website, http://www.smc.eu

VP500/700
How to Use DIN Terminal Connector Light/Surge Voltage Suppressor
DIN Terminal
Caution With light (DZ)
Connection (YZ)
1. Loosen the holding screw and pull the connector out of the No.1
solenoid valve terminal block. (–)(+)

Symbols
2. After removing the holding screw, insert a flat blade
screwdriver etc. into the notch on the bottom of the terminal Varistor Coil
block and pry it open, separating the terminal block and the No.2
housing. (+)(–) LED
3. Loosen the screw (slotted screws) in the terminal block. Insert There is no polarity.
the lead core wires to the terminals according to the connection

X536
method, and secure the wires by re-tightening the terminal Note) Surge voltage suppressor of varistor has residual voltage
screw. corresponding to the protective element and rated voltage;
4. Secure the cord by fastening the ground nut. therefore, protect the controller side from the surge voltage.

Caution

X538
Limit Switch Cable
When making connections, please note that using other than the
supported size (Ø 3.5 to Ø 7) heavy-duty cord will not satisfy IP65 OMRON or Rockwell Automation M12 connector limit switch ca-
(enclosure) standards. Also, be sure to tighten the ground nut ble is available.
and holding screw within their specified torque ranges. M12 Connector Cable (4 Pins) Made by OMRON

X555
X585
Changing the entry direction Part number Cable length [mm]
ZS-37-L 300
After separating the terminal block and housing, the cord entry
can be changed by attaching the housing in the desired direction ZS-37-M 500
ZS-37-N 1000

Accessories
(4 directions at 90° intervals).

Optional
ZS-37-P 2000
∗ When equipped with a light, be careful not to damage the light
ZS-37-C 5000
with the cord’s lead wires.

Precautions M12 Connector Cable (6 Pins) Made by Rockwell Automation

Specific Product
Plug in and pull out the connector vertically without tilting to one Part number Cable length [mm]

Precautions
side. VP500-231-1 2000

Compatible cable
Cord O.D.: Ø 3.5 to Ø 7
(Reference) 0.5 mm2, 2-core or 3-core, equivalent to JIS C 3306 Installation
Use the external pilot type when using VP500/700-X536 or X538
with AV series. Install the AV series to the primary side.

VG342
Ground nut
Tightening torque
1.65 to 2.5 N·m
Holding screw
Tightening torque
Washer 0.4 N·m

Grommet
(Rubber) Housing
Symbols
Voltage symbol (Position for light
Type D: 24 V mounting)
Type Y: 24 VN
Terminal block
Terminal screw Notch
(3 locations)
X87

Tightening torque
0.2 to 0.25 N·m

Type “Y”
Specific Product
Precautions

DIN connector type Y is a DIN connector that confirms to the DIN


pitch 8-mm standard.
• D type DIN connector with 9.4 mm pitch between terminals is
not interchangeable.
• To distinguish from the D type DIN connector, “N” is listed at the
end of voltage symbol.
• Dimensions are completely the same as D type DIN connector.

18
Safety Standard ISO 13849-1 Certified

3 Port Solenoid Valve/Residual Pressure Release ∗ Refer to page 2 for


compliant products.

Valve with Detection of Main Valve Position


VG342-X87

How to Order

Dual residual pressure release valve VG342 R 5 D Z 06 F M X87

Pilot Safety limit switch/Wiring


— Internal pilot M12 connector
M (Made by OMRON)
R External pilot
M12 connector
S1 (Made by Rockwell Automation)
Voltage
5 24 V DC
Thread
Electrical entry — Rc
D DIN terminal F G
N NPT

Light/surge voltage suppressor


Z With light/surge voltage suppressor With check valve (Only external pilot)
Check Applicable Thread
valve tube O.D. Rc G NPT
Port size
06 3/4" — None — ! ! !
10 1" A Ø8 ! — —
Yes
B Ø 5/16" — — !
∗ For internal pilot, the symbol is nil.
∗ Refer to “Piping for External Pilot Type” on page 20 for
selection of the check valve.

Made to Order

1 Series Compatible with Secondary Batteries


For details about 25A-, please contact SMC.

How to Order

25A–VG342" – 5DZ – "" – M" – X87

Fill in according to How to Order above. Note) Electrical entry can be selected only for D type.
Check valve type is available only when the thread
Secondary battery compatible type is Rc.

19
3 Port Solenoid Valve/
VG342-X87
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position

Valve Specifications

VP500/700
Fluid Air
Type of actuation N.C. (Spring return)
Operation Internal pilot External pilot
Operating pressure range 0.25 to 0.7 MPa 0.25 to 0.7 MPa
0.25 to 0.7 MPa
External pilot pressure —
(Same as operating pressure)
Maximum operating frequency 30 times/minute
Minimum operating frequency 1 time/week

Symbols
Operating and ambient temperature −10 to 50 °C (No freezing)
Ambient humidity 95 %RH or less (No condensation)
Manual override None
Pilot exhaust Individual exhaust

X536
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance 150/50 m/s2
Enclosure IP40
Operating environment Indoors

X538
Weight 2.8 kg 2.9 kg
B10d (MTTFd calculation) 900000 times

Internal Pilot Type

X555
X585
Caution
Valve may not operate properly when air supply to P port is not adequate and the supply pressure
to the valve is lower than 0.25 MPa, the minimum operating pressure. Be careful with insufficient
supply pressure.

Accessories
Optional
Piping for External Pilot Type
Caution
The product may not operate when the external pilot pressure is insufficient due to simultaneous

Specific Product
operation or restricted air piping. In this case, use the check valve (AKH series) with the external

Precautions
pilot port, change the piping size or adjust the set pressure to provide a constant pressure of 0.25
MPa or more.

Flow Rate Characteristics

VG342
Flow rate characteristics
1!2 (P!A) 2!3 (A!R)
Series
C Q C Q
b Cv b Cv
[dm3/(s·bar)] [l/min (ANR)]∗ [dm3/(s·bar)] [l/min (ANR)]∗
VG342-X87 26.6 0.04 5.5 5864 28.6 0.03 5.6 6278
∗ These values have been calculated according to ISO 6358 and indicate the flow rate under standard Symbols
conditions with an inlet pressure of 0.6 MPa (relative pressure) and a pressure drop of 0.1 MPa

Solenoid Specifications Safety Limit Switch Specifications


X87

Electrical entry DIN terminal Manufacturer OMRON Rockwell Automation


Rated voltage 24 V DC Electrical wiring M12 connector
Allowable voltage Contact resistance 25 mΩ or less 50 mΩ or less
Specific Product

–15 % to +10 % of
Precautions

fluctuation rated voltage Min. applicable load 5 V DC, 1 mA (Load resistance) 5 V DC, 5 mA (Load resistance)
Power consumption 2.2 W Max. voltage 24 V DC
Suppressor Diode Max. load current 50 mA
Indicator LED Max. load inductance 0.5 H
Insulation voltage 300 V 600 V
Protection against electric shock Class II (EN 60947-5-1: 2004)

20
VG342-X87

Symbols
Safety limit switch
Made by
OMRON

Symbol Pin Numbers (Built-in switch 2N.C.)


M12 connector
Wiring specification
pin number

VG342(R)-X87
Internal pilot External pilot External pilot/With check valve
2(A) 2(A) 2(A)

3(R) 3(R) 3(R)

3(R) 3(R) 3(R)

1(P) Safety limit switch terminal [N.C.] X 1(P) 1(P)


M12 connector pin number X

Safety limit switch


Made by
Rockwell Automation

Symbol Pin Numbers (Built-in switch 3N.C.)


M12 connector
Wiring specification
pin number
q
t
w
y
e
r

VG342(R)-X87
Internal pilot External pilot External pilot/With check valve
2(A) 2(A) 2(A)

3(R) 3(R) 3(R)

3(R) 3(R) 3(R)

1(P) X 1(P) X 1(P)

21
3 Port Solenoid Valve/
VG342-X87
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position

Dimensions Dual Residual Pressure Release Valve (-X87)

VP500/700
VG342(R)-5DZ-06$-M$-X87
Safety limit switch
Made by
OMRON

Port size: 1/8" (Without check valve)


Applicable tube O.D.: Ø 8, Ø 5/16" (With check valve)

Symbols
(External pilot port)
Channel 2 Channel 1 64.5
Safety limit switch (made by OMRON)
A 34
Part number: D4N-9B31
M12 x 1
Applicable cable O.D. Pg9

X536
Ø 4.5 to Ø 7

X538
(190.9: For external pilot)
Vent port (75) (48.2)
214.1

Should be normally open.

175.9
3 x Ø 8.5
(Mounting hole)

X555
X585
3 3 (Max. 3)

(106.6)
(27.7)

57.6
41.5
(69.5)

2 1
56
43.8

43.8

Accessories
(11.4)

Optional
28

21
37.5 73 73 10 37.5
3/4" 75 45.5 77
[1(P) port]

Specific Product
2 x 3/4" [3(R) port] 164.5 3/4"

Precautions
Should be normally open. [2(A) port]

75 42.3
34

VG342
74

View A
M12 connector

Symbols
Pin
number
X87
Specific Product
Precautions

22
VG342-X87

Dimensions Dual Residual Pressure Release Valve (-X87)

VG342(R)-5DZ-10$-M$-X87
Safety limit switch
Made by
OMRON

Port size: 1/8" (Without check valve)


Applicable tube O.D.: Ø 8, Ø 5/16" (With check valve)
(External pilot port)
Channel 2 Channel 1 64.5
Safety limit switch (made by OMRON)
A 34
Part number: D4N-9B31
M12 x 1
Applicable cable O.D. Pg9
Ø 4.5 to Ø 7

16.6

(190.9: For external pilot)


Vent port (75) (76.2)
Should be normally open.
214.1

175.9
3 x Ø 8.5
(Mounting hole)
3 3 (Max. 3)

(106.6)
(27.7)
41.5
(69.5)

2 1
56
43.8

43.8
28

37.5 Adapter 73 73 38 37.5

18.6
1" 75 43.5 30 (5) 77
[1(P) port] 2 x 1" [3(R) port] 30 160.5 1"
Should be normally open. 220.5 [2(A) port]
230.5

75 75.3
View A
M12 connector
34
74

Pin
number

23
3 Port Solenoid Valve/
VG342-X87
Safety Standard ISO 13849-1 Certified
Residual Pressure Release Valve with Detection of Main Valve Position

Dimensions Dual Residual Pressure Release Valve (-X87)

VP500/700
VG342(R)-5DZ-06$-S1$-X87
Safety limit switch
Made by
Rockwell Automation

Port size: 1/8" (Without check valve)


Applicable tube O.D.: Ø 8, Ø 5/16" (With check valve)

Symbols
(External pilot port)
Safety limit switch Channel 2 Channel 1 64.5
(made by Rockwell Automation) A 34
Part number: 440P-CDPB03R6 M12 x 1
Applicable cable O.D. Pg9

X536
Ø 4.5 to Ø 7

X538
(190.9: For external pilot)
Vent port (75) (48.2)
218.7

Should be normally open.

175.9
3 x Ø 8.5

X555
X585
(Mounting hole)
3 3 (Max. 3)

(106.6)
(27.7)

57.6
41.5
(69.5)

2 1

Accessories
56
43.8

43.8

Optional
(11.4)
28

21
37.5 73 73 10 37.5
3/4" 75 45.5 77

Specific Product
[1(P) port] 2 x 3/4" [3(R) port] 164.5

Precautions
3/4"
Should be normally open. [2(A) port]

75 42.3
34

VG342
74

View A
M12 connector

Symbols
Pin
number
X87
Specific Product
Precautions

24
VG342-X87

Dimensions Dual Residual Pressure Release Valve (-X87)

VG342(R)-5DZ-10$-S1$-X87
Safety limit switch
Made by
Rockwell Automation

Safety limit switch Port size: 1/8" (Without check valve)


(made by Rockwell Automation) Applicable tube O.D.: Ø 8, Ø 5/16" (With check valve)
Part number: 440P-CDPB03R6 (External pilot port)

Applicable cable O.D. Channel 2 Channel 1


64.5
Ø 4.5 to Ø 7 A
34
M12 x 1
Pg9

(13.4)

175.9: For internal pilot


Vent port (75) (76.2)
218.7

Should be normally open.

190.9
3 x Ø 8.5
(Mounting hole)
3 3 (Max. 3)

(106.6)
(27.7)
41.5
(69.5)

N
2 1
56
43.8

43.8
28

37.5 73 73 38 37.5

18.6
1" 75 43.5 30 (5) 77
[1(P) port] 2 x 1" [3(R) port] 30 160.5 1"
Should be normally open. 220.5 [2(A) port]
230.5

75 75.3

View A
M12 connector
34
74

Pin
number

25
VG342-X87
Specific Product Precautions
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to the Operation Manual on the SMC
website, http://www.smc.eu

VP500/700
How to Use DIN Terminal Connector Light/Surge Voltage Suppressor

Caution Terminal number 1


(+)
Connection Coil
1. Loosen the holding screw and pull the connector out of the
solenoid valve terminal block. Terminal number 2

Symbols
2. After removing the holding screw, insert a flat blade (–)
screwdriver etc. into the notch on the bottom of the terminal
block and pry it open, separating the terminal block and the
housing.
3. Loosen the screw in the terminal block. Insert the lead core Limit Switch Cable
wires to the terminals, and secure the wires by re-tightening

X536
OMRON or Rockwell Automation M12 connector limit switch ca-
the terminal screw. ble is available.
As the product has polarity, referring to the electric circuit
diagram, wire the product correctly as per the symbol of the M12 Connector Cable (4 Pins) Made by OMRON
terminal No. of the terminal block. Part number Cable length [mm]
4. Secure the cord by fastening the ground nut.

X538
ZS-37-L 300
Tighten the ground nut and holding screw within the specified ZS-37-M 500
range of torque. ZS-37-N 1000
Changing the entry direction ZS-37-P 2000
ZS-37-C 5000
After separating the terminal block and housing, the cord entry

X555
X585
can be changed by attaching the housing in the opposite direction
180°. M12 Connector Cable (6 Pins) Made by Rockwell Automation
∗ Be careful not to damage the element etc. with the cord’s lead Part number Cable length [mm]
wires. VP500-231-1 2000

Accessories
Optional
Precautions
Plug in and pull out the connector vertically without tilting to one
side.

Specific Product
Compatible cable

Precautions
Cord O.D.: Ø 4.5 to Ø 7 (Reference) 0.5 to 1.5 mm2, 2-core or
3-core, equivalent to JIS C 3306

Applicable crimped terminals


O-terminals: Equivalent to R1.25-4M defined in the JIS C 2805
Y-terminals: Equivalent to 1.25-3L made by J.S.T. Mfg. Co., Ltd.
Rod-terminals: Up to size 1.5

VG342
Ground nut
Holding screw
Tightening torque
2.5 to 3.75 N·m Tightening torque
0.5 to 0.6 N·m

Washer Housing
Grommet
(Rubber)
Symbols

Terminal block
Terminal number
Terminal screw
3 locations
X87

Tightening torque
0.4 to 0.5 N·m
Specific Product
Precautions

26
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with the
labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety
and must be followed in addition to International Standards (ISO/IEC)∗1), and other
safety regulations.
Caution indicates a hazard with a low level of risk ∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution: which, if not avoided, could result in minor or moderate
injury.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
Warning indicates a hazard with a medium level of risk (Part 1: General requirements)
Warning: which, if not avoided, could result in death or serious
injury.
ISO 10218-1: Manipulating industrial robots - Safety.
etc.
Danger indicates a hazard with a high level of risk
Danger : which, if not avoided, will result in death or serious injury.

Warning Limited warranty and Disclaimer/


1. The compatibility of the product is the responsibility of the person Compliance Requirements
who designs the equipment or decides its specifications.
Since the product specified here is used under various operating conditions, its
The product used is subject to the following “Limited warranty and
compatibility with specific equipment must be decided by the person who designs the Disclaimer” and “Compliance Requirements”.
equipment or decides its specifications based on necessary analysis and test results. Read and accept them before using the product.
The expected performance and safety assurance of the equipment will be the
responsibility of the person who has determined its compatibility with the product. This
person should also continuously review all specifications of the product referring to its
latest catalogue information, with a view to giving due consideration to any possibility of
Limited warranty and Disclaimer
equipment failure when configuring the equipment. 1. The warranty period of the product is 1 year in service or 1.5 years
2. Only personnel with appropriate training should operate machinery after the product is delivered, wichever is first.∗2)
and equipment. Also, the product may have specified durability, running distance or
The product specified here may become unsafe if handled incorrectly. The assembly,
replacement parts. Please consult your nearest sales branch.
operation and maintenance of machines or equipment including our products must be
performed by an operator who is appropriately trained and experienced. 2. For any failure or damage reported within the warranty period which is clearly
3. Do
. not service or attempt to remove product and our responsibility, a replacement product or necessary parts will be provided.
machinery/equipment until safety is confirmed. This limited warranty applies only to our product independently, and not to any
1. The inspection and maintenance of machinery/equipment should only be performed other damage incurred due to the failure of the product.
after measures to prevent falling or runaway of the driven objects have been
confirmed. 3. Prior to using SMC products, please read and understand the warranty
2. When the product is to be removed, confirm that the safety measures as mentioned terms and disclaimers noted in the specified catalogue for the particular
above are implemented and the power from any appropriate source is cut, and read
products.
and understand the specific product precautions of all relevant products carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected ∗2) Vacuum pads are excluded from this 1 year warranty.
operation and malfunction. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum
4. Contact SMC beforehand and take special consideration of safety pad or failure due to the deterioration of rubber material are not covered by the limited
measures if the product is to be used in any of the following warranty.
conditions.
1. Conditions and environments outside of the given specifications, or use outdoors or in
a place exposed to direct sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air navigation, Compliance Requirements
space, shipping, vehicles, military, medical treatment, combustion and recreation, or 1. The use of SMC products with production equipment for the manufacture of
equipment in contact with food and beverages, emergency stop circuits, clutch and
brake circuits in press applications, safety equipment or other applications unsuitable weapons of mass destruction (WMD) or any other weapon is strictly
for the standard specifications described in the product catalogue. prohibited.
3. An application which could have negative effects on people, property, or animals
2. The exports of SMC products or technology from one country to another are
requiring special safety analysis.
4. Use in an interlock circuit, which requires the provision of double interlock for possible governed by the relevant security laws and regulations of the countries
failure by using a mechanical protective function, and periodical checks to confirm involved in the transaction. Prior to the shipment of a SMC product to
proper operation. another country, assure that all local rules governing that export are known
and followed.

Caution Caution
1. The product is provided for use in manufacturing industries. SMC products are not intended for use as instruments for legal
The product herein described is basically provided for peaceful use in manufacturing metrology.
industries. Measurement instruments that SMC manufactures or sells have not been qualified by
If considering using the product in other industries, consult SMC beforehand and exchange type approval tests relevant to the metrology (measurement) laws of each country.
specifications or a contract if necessary. Therefore, SMC products cannot be used for business or certification ordained by the
If anything is unclear, contact your nearest sales branch. metrology (measurement) laws of each country.

Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.
SMC Corporation (Europe)
Austria +43 (0)2262622800 www.smc.at office@smc.at Lithuania +370 5 2308118 www.smclt.lt info@smclt.lt
Belgium +32 (0)33551464 www.smcpneumatics.be info@smcpneumatics.be Netherlands +31 (0)205318888 www.smcpneumatics.nl info@smcpneumatics.nl
Bulgaria +359 (0)2807670 www.smc.bg office@smc.bg Norway +47 67129020 www.smc-norge.no post@smc-norge.no
Croatia +385 (0)13707288 www.smc.hr office@smc.hr Poland +48 222119600 www.smc.pl office@smc.pl
Czech Republic +420 541424611 www.smc.cz office@smc.cz Portugal +351 226166570 www.smc.eu postpt@smc.smces.es
Denmark +45 70252900 www.smcdk.com smc@smcdk.com Romania +40 213205111 www.smcromania.ro smcromania@smcromania.ro
Estonia +372 6510370 www.smcpneumatics.ee smc@smcpneumatics.ee Russia +7 8127185445 www.smc-pneumatik.ru info@smc-pneumatik.ru
Finland +358 207513513 www.smc.fi smcfi@smc.fi Slovakia +421 (0)413213212 www.smc.sk office@smc.sk
France +33 (0)164761000 www.smc-france.fr info@smc-france.fr Slovenia +386 (0)73885412 www.smc.si office@smc.si
Germany +49 (0)61034020 www.smc.de info@smc.de Spain +34 902184100 www.smc.eu post@smc.smces.es
Greece +30 210 2717265 www.smchellas.gr sales@smchellas.gr Sweden +46 (0)86031200 www.smc.nu post@smc.nu
Hungary +36 23511390 www.smc.hu office@smc.hu Switzerland +41 (0)523963131 www.smc.ch info@smc.ch
Ireland +353 (0)14039000 www.smcpneumatics.ie sales@smcpneumatics.ie Turkey +90 212 489 0 440 www.smcpnomatik.com.tr info@smcpnomatik.com.tr
Italy +39 0292711 www.smcitalia.it mailbox@smcitalia.it UK +44 (0)845 121 5122 www.smcpneumatics.co.uk sales@smcpneumatics.co.uk
Latvia +371 67817700 www.smclv.lv info@smclv.lv
SMC CORPORATION Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362
1st printing TT printing TU 00 Printed in Spain Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

You might also like