Factory Automation Cable

KDF-L
KURAMO Bending Resistant Cable (FTFE Insulated/Layer Stranded Type)

UL AWM 2103/2517
Characteristics Radar Chart
Heat resistance
5

4
Cable carrier Oil resistance
resistance
3

2 Features
1 ■ Cable designed to UL, cUL standards
0 ■ Oil resistance/Bending resistance
left/right
Noise
bending ■ Mat sheath
resistance
resistance

45°left/right vibration
resistance Twist resistance Application
■ Cable carrier wiring
KDF-L General VCTF
※The characteristics of the cable indicated on the radar chart are intended for
use as a general guide for selecting the cable meeting your requirements.
Certification

Technical Data
UL, cUL
Size 4 cores or less×0.2-0.5Ý 5-10 cores×0.2-0.5Ý 2-10 cores×0.75-2Ý
Voltage Rating 300V
Temperature Rating 105℃
Test Voltage AC 2000V・1min
Flame Resistance FT2 VW-1, FT1
UL AWM Style 2103 UL AWM Style 2517
Applicable Standard
CAN/CSA-C22.2 No.210 CAN/CSA-C22.2 No.210
The KDF-SBL, when applied in compliance with the standards in Japan, can be used for cable connection to signal and communication circuits
and other weak current electrical circuits.

Electrical Characteristics
Nominal Cross-Sectional Number of Cores Allowable Current(A)
Item
Area(Ý)(AWG) 2∼10 2 3 4 5 6 7 8 10
0.2 (25) 105 − 5 5 4 4 4 4 4
0.3 (23) 71.5 − 8 7 6 6 5 5 5
Conductor Resistance 0.5 (21) 43.4 − 9 9 8 8 7 7 7
(20℃)
Ω/Ü or below 0.75(19) 27.5 14 12 11 11 10 10 9 9
1.25(16) 14.1 21 18 17 16 15 14 14 13
2 (14) 9.89 25 22 20 19 18 17 17 16
Insulation Resistance
0.2(25)∼2(14) 1500
MΩÜ or above
●Allowable Current (A) for the cable is based on calculation under aerial one-cable
Test Voltage V・min 2000
installation at ambient temperature of 30℃, not representing a guaranteed value.
Allowable current for the cable at ambient temperature above 30℃ is to be determined
by multiplying the current value by the appropriate current reduction factor specified in
the following table for the ambient temperature.

■ Current Reduction Factor Table


Ambient Temperature(℃) 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
Current Reduction Factor 1.00 0.97 0.93 0.89 0.86 0.82 0.77 0.73 0.68 0.63 0.58 0.52 0.45 0.36 0.26

73
Cable Construction Core Identification
Item 0.2Ý 0.3Ý∼2Ý Core identification
Tin-plated soft annealed Tin-plated soft annealed Identification by color
Conductor

Insulator
stranded copper stranded copper composite
Fluorocarbon resin (ETFE)
( in order of black, white, red, green, yellow,
brown, blue, gray, orange and purple
)
Conductor stranding Circular
Core wrapping tape Tape wrap around cores
Sheath Heat resistant PVC (black)

KDF-L
■ Example: 3 core (1.25Ý) cable
Sheath
Conductor

KDF KURAMO 耐久性ケーブル(耐屈曲 耐熱 耐油型)1.25Ý LF


KURAMO E162205-K AWM STYLE 2517 Ⅰ A/B 105C 300V VW-1 FT1 16AWG

Tape
Insulator

Cable Outside Diameter/Weight


Nominal cross-sectional area〈AWG〉 Number of cores
Conductor count/wire diameter 2 3 4 5 6 7 8 10
0.2 (40/0.08) 3.7 ※4.9 ※5.2 ※5.5 ※5.8 ※6.1 ※6.7
<25> − 20 30 35 40 45 50 60
0.3 (3/20/0.08) 4.3 ※5.6 ※6.0 ※6.4 ※6.8 ※7.2 ※8.0
<23> − 25 40 50 55 65 70 85
0.5 (3/33/0.08) 5.0 ※6.3 ※6.8 ※7.3 ※7.8 ※8.3 ※9.3
<21> − 35 55 65 75 85 95 115
0.75(7/22/0.08) ※6.1 ※6.4 ※7.0 ※7.6 ※8.2 ※8.8 ※9.3 ※11.0
<19> 45 60 75 90 105 120 135 165
1.25(7/43/0.08) ※7.1 ※7.5 ※8.1 ※9.0 ※9.9 ※10.5 ※11.5 ※13.5
<16> 70 90 115 140 170 195 225 280
2 (7/61/0.08) ※7.7 ※8.1 ※8.8 ※10.0 ※11.0 ※12.0 ※12.5 ※14.5
<14> 90 115 150 185 220 260 295 365
KDF-L cable, which is exempt from the application of the Electrical Appliance and Upper: Standard cable outside diameter(Approx.Ù)
Material Safety Law, can be used for cable connection to signal and communication Lower: Approximate weight(è/Ü)
<PS>E

circuits and other weak current electrical circuits in Japan. ※ indicates specifications for custom order production.
UL AWM
NFPA79
NFPA70
CE
CCCcUL/CSA
GOST-R