: GP230780DAB_REF
Software Basic Data
OTIS SCN: GP230780DAB
GCS - GECB
Reference List
Revision History
Date Rev Author Comment
2004-08-26 G1530780AAA A. Pfeffer first document based on TCBC Software
GAA30084AAF
2005-01-27 G2130780AAA H.-K. Spielbauer Number update only prior shipping
2005-03-03 G2230780AAA A. Pfeffer conditions for EFO inputs added
2005-03-29 G2430780AAA A. Pfeffer blink messages "DOL alw. on", "No 110VAC",
"OmuPresent" added
Event "0307 RDOL alw.on" added
2005-04-06 GAA30780AAA A. Pfeffer Release
2005-07-21 GAA30780AAB A. Pfeffer HPB added for Compass
2005-10-25 GAA30780AAC A. Pfeffer no changes
2006-10-26 GAA30780BAA B. Braasch Op. Mode: CBP; EAR; added
Mo. State: SD->SR; renamed., ES; EF; EW;
RL; added
Mo.Command: Relevel; added
System inputs: GDS; L30; L50; GSM; DHB;
SDB; ^GSM; ^DHB; ^SDB; ADB; EDB;1EF;
2EF; DDS; DES; EQ1; EQ2; EQ3; EQW;EQR;
ISP; FAN; ^FAN; CTC; CTO; PKG; CFB; IST;
ROT; ACC; ACH; GSI; HCH; GCO; CHC;
GCB; ^GCB; LDS; MAS; HCR; ATK; ^RB;
GRT; DPC; UPC; DUP; SRO; AD1; AD2; AD3;
BPZ; ELZ; GFB; WCO; SG1-SG7; CS1-CS6;
CSC; CSK; GSK; CLR; DFO; ^DFO; LEV;
DCD; CCB; CCT; PC1-PC8; SHC SHT; AMC;
LPT; SMB; added
System outputs: UD; added
Blink message: MRO active; added
Event logging: 16; 17; 19; 109; 110; 213-217;
224; 225; 308-315; 319; 505-507; 604; 605;
added
Table of Contents
1 Operational Modes...........................................................................4
2 Motion States ...................................................................................5
3 System Inputs...................................................................................6
4 System Outputs..............................................................................10
5 Info Messages ................................................................................11
6 Blinking Event Messages ..............................................................12
7 Event Logging ................................................................................15
8 Diagnostic Parameters ..................................................................20
9 Commands .....................................................................................21
No.: GP230780DAB_REF
Software Basic Data
OTIS SCN: GP230780DAB
1 Operational Modes
2 Motion States
3 System Inputs
The following list shows all available inputs and the condition under which these inputs are
displayed (set DISP-ALL=1 to view all available inputs).
BY Drive BY-Relay
BRK BR-Relay
4 System Outputs
NUD Emergency
NUG
5 Info Messages
The following messages are accessible in the Main Menu GECB – Menu.
Please use Shift Key UP.
# RSL's: 1 > Number of RSL links. "3" is displayed if the GECB-IO board
3 > physically supports 3 links and the parameter RSL-TYP=1 is
set. Otherwise "1" is displayed.
No.: GP230780DAB_REF
Software Basic Data
OTIS SCN: GP230780DAB
The following messages are blinking in each status display of the Service Tool:
Note:
This message has been renamed in AAE.
LBG/CSP-2 Light Beam Gate has been active. LBG
(967, 968)
SPB: HTS Hall Temperature Sensor from Service Panel Board is SPB-Temp
activated. Car is shutdown at next committable floor and
taken out of service until the temperature is lower than
parameter SPB-Temp.
SPB-Comm. CAN-Communication to SPB is not working.
Æ check CAN-wiring
Æ check CAN-LEDs
MRO active The SPB requests to ignore the inputs at Manual Res-
cue Run.
No.: GP230780DAB_REF
Software Basic Data
OTIS SCN: GP230780DAB
7 Event Logging
The table below lists all possible event logging messages of the Service Tool. The events
are devided into the following classes:
I Info
W Warning
F Fault
Operating System
0000 Task Timing W Dummy task has not been called within -
timeout. Software has been restarted.
0001 S/W Reset W watchdog circuit on GECB was triggered. -
Software has been restarted.
0002 Illegal Int W illegal interupt was executed -
0003 CanTxFull W CAN messages cannot be sent -
0004 CanBusOff W CAN communication has been restarted -
0006 StackCheck F Stack Violation was detected. Software -
has been restarted.
0007 SCN Error F Wrong Software. -
Æ order a new software with correct part-
number.
0008 TimerSync F Internal software timers have not been -
updated correctly. Software has been
restarted.
0009 Task Fail F Application software doesn't run properly. -
Software has been restarted.
0010 McbCommErr F No CAN connection to the drive -
0011 SpbCommErr W No CAN connection to the SPB -
0012 Power On I Board has been powered on. -
0013 Event Fail W -
0014 PowerOffOn I Short Failure of PowerSupply. -
0016 S/W Restart W Reset with unknown reason -
0017 Trace Error F bad value in the eventTraceControl buffer -
0019 MissedLvInt F lv1 and lv2 edge was missed -
Group
0500 RNG1 msg W data error on Duplex/Triplex ring -
0501 RNG1 time W no ring messages received from other car GROUP
for a specific time
0502 RNG1 sio W framing error on Duplex/Triplex ring -
0503 RNG1 tx W ring messages couldn't be sent in an ap- -
propriate time
0504 RNG1 rxOff W No messages are received within a time- -
out, and NO BREAK is detected.
0505 RNG1 reset W Reinitializing RING Service (stm_ring_run -
expired)
0506 DES offline F DES is not present -
0507 GCB offline F no GCB is present -
System
0600 SPB-Alert W The Service Panel Board detected a mal- -
function which hinders a manual rescue
operation with SPB and SDI. Possible rea-
sons are:
- defective speed encoders for SDI
- defective E2PROM on SPB
- Missing battery for SPB
Press the SPB-buttons REB + DDO simul-
taneously to locate the error.
0601 SPB:TempHTS W The Service Panel Board detected an SPB-Temp
overtemperature.
0602 LwssService W The LWSS requested “Request For Ser- -
vice” (REM). See LWSS event logging for
reason.
0604 S/W Changed I Informational event that new software was -
installed. The events are automatically
cleared. No action necessary.
0605 Update S/W! W New subsytem software was installed that -
requires new GECB software.
0606 SpbService W The SPB requested “Request For Service” -
(REM). See SPB event logging for reason.
No.: GP230780DAB_REF
Software Basic Data
OTIS SCN: GP230780DAB
8 Diagnostic Parameters
These diagnosis parameters are stored in non-volatile memory and are kept even if the
power is switched off. They can only be reset manually via Service Tool, except ACT-T and
REC-OK which are refreshed after each power-on.
9 Commands
These internal commands are used for the on-board DCSS and MCSS.
Type Display Description
Door Commands OPEN open door
DEEN deenergize door
CLD1 close door; no DOB, no LRD, no EDP
CLD2 close door; full DOB, full LRD, full EDP
CLD3 close door; full DOB, full LRD, lim EDP
CLD4 close door; full DOB, lim LRD, lim EDP
CLD5 close door; full DOB, no LRD, no EDP
CLD6 close door; full DOB, no LRD, lim EDP
CLD7 close door; lim DOB, no LRD, lim EDP
CLD8 close door; lim DOB, no LRD, no EDP
CLD9 close door; full SGS, nothing else