SPREADSHEET - BASE PLATE DESIGN

FOR CALCULATION OF PRESSURE BELOW BASE PLATE & TENSION IN BOLTS

INPUT: PROJECT: JOJOBERA POWER PLANT MILL AND BUNKER BUILDING


1. Pc-AXIAL LOAD IN TONNES JOB NO.: 3037 MAIN FRAME FOUNDATIONS
2. M- MOMENT IN TONNE METER
3. SF- SHEAR FORCE IN TONNES
4 .D- LENGTH OF BASE PLATE IN MAJOR DIRECTION IN MM
5. B- WIDTH OF BASE PLATE IN MM
6. F- DISTANCE OF C.L OF BOLTS FROM C.L OF COLUMN IN MM
7. BD - DIAMETER OF BOLTS
8. N - NUMBER OF BOLTS ON TENSION SIDE
9. Fck - CHARACTERISTIC STRENGTH OF CONCRETE IN N/MM 2

INSTRUCTION : CHANGE THE VALUE OF 'Y' TILL RHS BECOMES ZERO

NO.OF
GRADE
BOLTS MODU
BOLT OF F.O.S
Pc M SF Ecc D B F ON Ast Ass LAR K1 K2 K3 Y RHS Pt sc FOS (Pt) FOS (SF)
DIA(MM) CONC (TS)
TENSION RATIO
RETE
SIDE

67.5 4 10 59.2592593 900 600 400 36 3 2450.1 6107.3 30 9.6092 0 0 0 131.94844 0 0.00 17.44 0.000 0.201 0.201
-47.5 4 10 -84.2105263 900 600 400 36 3 2450.1 6107.3 30 9.6092 0 0 0 74.3266581 0 0.00 -3.86 0.000 0.201 0.201
Sheet2

NO.OF TENSILE TOTAL


DIA OF
BOLTS ON SHEAR AREA ARAE OF TENSION
BOLT
EACH SIDE ONE BOLT AREA
16 1 402.1238656 156.7 156.7
20 1 628.31854 244.8 244.8
22 1 760.2654334 303.4 303.4
25 1 981.74771875 352.5 352.5
28 1 1231.5043384 459.4 459.4
32 1 1608.4954624 560.5 560.5
36 1 2035.7520696 816.7 816.7
40 1 2513.27416 949.9 949.9
45 1 3180.86260875 1306 1306
50 1 3926.990875 1473 1473
56 1 4926.0173536 2030 2030
60 1 5654.86686 2362 2362
63 1 6234.49071315 2525 2525
72 1 8143.0082784 3459.6 3459.6
80 1 10053.09664 4343.8 4343.8
100 1 15707.9635 6994.6 6994.6

Page 2