Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

INSPECTION REQUIREMENTS MANUAL

PSM 1-6-7
R C CHECK X 500 HOURS
O
U
SYSTEM AND
INSPECTION REQUIREMENT T
ITEM
I D
N or
E A B 1 2 3 4 5 6 7 8 9 10 11 12
Chapter 21 – Air Conditioning
1. Heater Ejector Condition and security. X X X X
(Card 22–11)

2. Heater Silencer Condition and security; installation for X X X X


condition and security.
(Card 22–12)

3.(1) Ram Air Control Valve Operating mechanism for ease of operation X X X X
PART 1 BASIC INSPECTION - 21

and security; flexible cable, clamps and


brackets for condition and security.
(Card 22–10, 23–03)

3.(2) Ram Air Control Valve Functional test. X X X X


(Card FUN–E7)

4.(1) Cabin Air Control Operating mechanism for ease of operation X X X X


Valve and security; flexible cable, clamps and
brackets for condition and security.
(Card 22–10, 23–03)

4.(2) Cabin Air Control Functional test. X X X X


Valve
(Card FUN–E8)

5. Duct Temperature Security. X X


Sensor
(Card 29–10)

6. X X

DHC-6 TWIN OTTER


Outside Air Security.
Temperature Sensor
(Card 29–04)

7. Duct Overheat Switch Security. X X


(Card 29–10)
Nov. 30/18

8.(1) Cabin Temperature Condition and security. X X X X


Page 1

Sensor
(Card 25–05)

Print Date: 2023-07-22


Nov. 30/18
Page 2
PART 1 BASIC INSPECTION - 21

DHC-6 TWIN OTTER


R C CHECK X 500 HOURS
O
U
SYSTEM AND
INSPECTION REQUIREMENT T
ITEM
I D
N or
E A B 1 2 3 4 5 6 7 8 9 10 11 12
8.(2) Cabin Temperature Operational test, sensor blower. X X X X
Sensor (Power on).
(Card FUN–E2)

9.(1) Heating System Hot Security. X X X X


Air Valves
(Card 22–15)

9.(2) Heating System Hot Operational test, travel time from open to X X X X
Air Valves close. (Power on).
(Card FUN–E3)

10. Automatic Condition and security; mounting brackets X X


Temperature for security.
Controller
(Card 32–06)

11.(1) Cabin Exhaust Outlet Vent for condition and obstructions. X X X X X X X X X X X X

INSPECTION REQUIREMENTS MANUAL


(Card 11–16)

11.(2) Cabin Exhaust Outlet Outlet scoop for condition and security. X X
Clean as required.
(Card 31–04)

12. Heating System Condition and security. Clean as required. X X


Outlets
(Card 30–04)

13. Duct Assemblies


13.a.(1) Duct Assemblies - Free from obstruction. Clean as required. X
Ram Air Inlet
(Pre Mod 6/1070) (Card RA–EXT–1)

13.a.(2) Duct Assemblies - Screens for condition. Clean as required. X X X X

PSM 1-6-7
Ram Air Inlet
(Pre Mod 6/1070) (Card 22–01)

Print Date: 2023-07-22


INSPECTION REQUIREMENTS MANUAL
PSM 1-6-7
R C CHECK X 500 HOURS
O
U
SYSTEM AND
INSPECTION REQUIREMENT T
ITEM
I D
N or
E A B 1 2 3 4 5 6 7 8 9 10 11 12
13.b.(1) Duct Assemblies - Free from obstruction. Clean as required. X
Ram Air Inlet
(Mod 6/1070) (Card RA–EXT–1)

13.b.(2) Duct Assemblies - Scoop and duct for condition. Clean as X X X X


Ram Air Inlet required.
(Mod 6/1070) (Card 22–01)

13.c. Duct Assemblies - Security. X X X X


PART 1 BASIC INSPECTION - 21

Main Duct Fan


(Card 22–13)

13.d. Duct Assemblies Condition and evidence of overheat, X X X X


- Flight/Cabin connections for security. Ducts for condition
Compartment Heating and delamination, supporting structure for
Ducts condition and security.
(Card 22–14)

13.e. Duct Assemblies Condition and security; louvers for proper X X


- Flight/Cabin operation.
Compartment
Ventilating (Card 32–04, 30–05)

13.f. Duct Assemblies - Condition and security. X X


Recirculated Air Flap
Mechanism (Card 29–11)

14. Bleed Air Systems


14.a. Bleed Air Systems - Condition and security. Clamps and brackets X X

DHC-6 TWIN OTTER


Bleed Air Pipes below for condition and security. Insulation for
cockpit floor condition.
(Card 29–12)

14.b. Bleed Air Systems Condition and security. Clamps and brackets X X
Nov. 30/18

- Bleed Air Pipes in for condition and security. Insulation for


Cabin Ceiling area condition.
Page 3

(Card 32–22)

Print Date: 2023-07-22


Nov. 30/18
Page 4
PART 1 BASIC INSPECTION - 21

DHC-6 TWIN OTTER


R C CHECK X 500 HOURS
O
U
SYSTEM AND
INSPECTION REQUIREMENT T
ITEM
I D
N or
E A B 1 2 3 4 5 6 7 8 9 10 11 12
14.c.(1) Bleed Air Systems Condition and security. X X X X
- Bleed Air Shut Off
Valve in Nacelle (Card 42–08, 43–08)

14.c.(2) Bleed Air Systems Operational test. (Power on). X X X X X X


- Bleed Air Shut Off
Valve in Nacelle (Card FUN–D3)

15. Wing De-Vore Bleed


Air Ducts
15.a. Wing De-Vore Bleed Condition and security. Inspect for cracks. X
Air Ducts
Note Refer to S/B No. 6/355 and De Vore
(Pre Mod 6/1614)
S/B DAS1000SB instructions.
(Card 06–06, 07–06)

15.b. Wing De-Vore Bleed Condition and security, bellows (root rib end) X X X X

INSPECTION REQUIREMENTS MANUAL


Air Ducts for condition.
(Mod 6/1614) (Card 27–08, 28–09)

16. Electrical Wires and Condition and security, insulation for X X X X


Connections condition; bonding wire for condition.
(Card 22–08, 22–16)

17. Heating (Bleed Air) Functional test. (Power on). X X


System
(Card FUN–G2)

18.(1) Cooling and Condition and security, mounting brackets X X


Demisting Fans for security.
(Pre Mod 6/2014)
(SOO 6322) (Card 30–06)

PSM 1-6-7
18.(2) Cooling and Operational test. (Power on). X X X X
Demisting Fans
(Pre Mod 6/2014)
(SOO 6322) (Card FUN–E1)

Print Date: 2023-07-22


INSPECTION REQUIREMENTS MANUAL
PSM 1-6-7
R C CHECK X 500 HOURS
O
U
SYSTEM AND
INSPECTION REQUIREMENT T
ITEM
I D
N or
E A B 1 2 3 4 5 6 7 8 9 10 11 12
19. JB Air Conditioner
System
19.a. JB Air Conditioner Free from obstruction. Clean as required. X
System - Intakes and
Exhaust Outlets
(Pre Mod 6/2014) (Card RA–EXT–2)

19.b. JB Air Conditioner Condition and free from obstruction. X


System - Cabin Floor
PART 1 BASIC INSPECTION - 21

Return Air Grill Filter


(Pre Mod 6/2014) (Card 04–02)

19.c. JB Air Conditioner Condition and security; freedom from X X X X X X X X X X X X


System - Ducts obstruction.
(Pre Mod 6/2014) (Card 09–14)

19.d. JB Air Conditioner Condition, security and leakage. Check X X X X X X X X X X X X


System - Compressor belts for tension.
and Motor
(Pre Mod 6/2014) (Card 09–14)

19.e. JB Air Conditioner Condition, security and leakage. Clean as X X X X X X X X X X X X


System - Evaporator required.
and Fan
(Pre Mod 6/2014) (Card 09–14)

19.f. JB Air Conditioner Condition, security and leakage. Clean as X X X X X X X X X X X X


System - Condenser required.

DHC-6 TWIN OTTER


and Fan
(Pre Mod 6/2014) (Card 09–14)

19.g. JB Air Conditioner Condition, security and leakage. Clean as X X X X X X X X X X X X


Nov. 30/18

System - Receiver required.


Dryer
Page 5

(Pre Mod 6/2014) (Card 09–14)

Print Date: 2023-07-22


Nov. 30/18
Page 6
PART 1 BASIC INSPECTION - 21

DHC-6 TWIN OTTER


R C CHECK X 500 HOURS
O
U
SYSTEM AND
INSPECTION REQUIREMENT T
ITEM
I D
N or
E A B 1 2 3 4 5 6 7 8 9 10 11 12
19.h. JB Air Conditioner Condition, security and leakage. X X X X X X X X X X X X
System - Expansion
Valve
(Pre Mod 6/2014) (Card 09–14)

19.i. JB Air Conditioner Condition, security and leakage. X X X X X X X X X X X X


System - Pressure
Switch
(Pre Mod 6/2014) (Card 09–14)

19.j. JB Air Conditioner Condition, security and leakage. X X X X X X X X X X X X


System - Thermostat
Switch
(Pre Mod 6/2014) (Card 09–14)

19.k. JB Air Conditioner Condition, security and leakage. Panel relay X X X X X X X X X X X X

INSPECTION REQUIREMENTS MANUAL


System - Relay Panel components for condition and security.
(Pre Mod 6/2014) (Card 09–14)

19.l. JB Air Conditioner Condition, security and leakage. Insulation X X X X X X X X X X X X


System - Electrical for condition and clipping for security;
Wiring and connections for security.
Connections
(Card 09–14)
(Pre Mod 6/2014)
19.m. JB Air Conditioner Condition, security and leakage. X X X X X X X X X X X X
System - Pipelines Connections for security and insulation for
and Connections condition.
(Pre Mod 6/2014) (Card 09–14)

19.n. JB Air Conditioner Operational test. (Power on). X X X X X X


System - Air

PSM 1-6-7
Conditioner System
(Pre Mod 6/2014) (Card FUN–D4)

Print Date: 2023-07-22


INSPECTION REQUIREMENTS MANUAL
PSM 1-6-7
R C CHECK X 500 HOURS
O
U
SYSTEM AND
INSPECTION REQUIREMENT T
ITEM
I D
N or
E A B 1 2 3 4 5 6 7 8 9 10 11 12
20.(1) Fwd Avionics Cooling Condition, security and free of obstruction; X X X X X X
Fans bonding wires for condition and security of
attachment. Clean as required.
(Mod 6/2049)
(Card 15–19)

20.(2) Fwd Avionics Cooling Function test. (Power on). X


Fans
(Mod 6/2049) (Card FUN–A6)
PART 1 BASIC INSPECTION - 21

21.(1) DAU Cooling Fans Condition and security; bonding wires for X X X X X X
condition and security of attachment.
(Mod 6/2049)
(Card 18–23c)

21.(2) DAU Cooling Fans Function test. (Power on). X


(Mod 6/2049) (Card FUN–A7)

22. Fwd Avionics Condition, security and free of obstruction. X X X X X X


Compartment Air Clean as required.
Filter
(Mod 6/2014) (Cards 15–19A, SP1–G8)

23.(1) STA 111 Cabin Fans Condition and security; standoff mounting X X X X X X X X X X X X
brackets for security.
(SOO 6378)
(Card 11–25)

23.(2) STA 111 Cabin Fans Operational Test (Power on) X X X X X X


(SOO 6378) (Card FUN–D9)

DHC-6 TWIN OTTER


23.(3) STA 111 Cabin Fans Electrical EMI noise filter for condition, X X X X
EMI Filter security and signs of overheating. Wiring
for condition, overheating or arcing; ground
(SOO 6378)
post for tightness and corrosion.
Nov. 30/18

(Card 30–12)
Page 7

Print Date: 2023-07-22


Nov. 30/18
Page 8
PART 1 BASIC INSPECTION - 21

DHC-6 TWIN OTTER


R C CHECK X 500 HOURS
O
U
SYSTEM AND
INSPECTION REQUIREMENT T
ITEM
I D
N or
E A B 1 2 3 4 5 6 7 8 9 10 11 12
24.(1) STA 332 Blower Condition and security; mounting tray for X X X X X X X X X X X X
security; outlet screen for debris. Clean as
(SOO 6379)
required.
(Card 11–26)

24.(2) STA 332 Blower Operational Test (Power on) X X X X X X


(SOO 6379) (Card FUN–D10)