i07284244
Caterpillar Products
All
Introduction
The problem that is identified below has a known solution. Use the solution that is identified below.
Problem
The flange head on 442-5593 Coupling As may have been manufactured incorrectly. The couplings
that were manufactured incorrectly have a date code of FATR.
Solution
Use the following procedure to determine if the coupling assembly is correct:
Illustration 1 g06275152
(A) 14.25 ± 0.15 mm (0.561 ± 0.006 inch)
3. The flange thickness should have dimension (A) if the coupling is good.
Illustration 2 g06275156
(B) 10 mm (0.4 inch)
4. If the flange thickness has dimension (B), replace existing 442-5593 Coupling As with correct
442-5593 Coupling As (as referred in Illustration 1).