Service Information

Document Title: Function Group: Information Type: Date:


Bleeding air 993 Service Information 1/25/2022
Profile:
WLO, L180H, L250H, L150H, L180H HL, L220H [GB]

Bleeding air
Op nbr

Total procedure time (hr): 0.40

Pump unit, bleeding air

1. Make sure that the lubricant reservoir is full of grease.


For filling, see: Filling lubricant

2. Remove both hose connections from the pump unit's ports.

Figure 1

1. Hose connections, 2 pcs.

3. Turn the start key to ignition position


4. Press in the test button on the pump unit for at least 6 seconds.

Figure 2

1. Test button

5. Turn off the ignition when clean grease has been pressed out from the nipple.

Figure 3
1. Grease

6. Turn the start key to ignition position and press in the test button again for at least 6 seconds. Now grease will be
pressed out from the other port on the pump unit.

7. Turn off the ignition when clean grease has been pressed out from the port.

8. Reinstall the hose connections on the pump unit.

Central lubrication system, bleeding air

9. Remove one of the plugs from the distribution block that is located farthest away in the system.

Figure 4

1. Distribution block

10. Turn the start key to ignition position

11. Press in the test button on the pump unit for at least 6 seconds. Now grease will be pressed out from the port.

12. Turn off the ignition when clean grease has been pressed out from the nipple.
Figure 5

1. Grease

13. Turn the start key to ignition position and press in the test button again for at least 6 seconds. Now grease will be
pressed out from the other port on the pump unit.
Turn off the ignition when clean grease has been pressed out from the nipple.

14. Reinstall the plugs on the distribution block

15. Restore the machine.

You might also like