UF 8046 MEMBRANE SPECIFICATION

Brand-new Flowrate(T/H) 8
Designed Flowrate(T/H) 1.5-2.5
Designed Standard(L/m².h)25°C 60-160
Performace Water Output (SDI) <1
Output Turbidity <0.1NTU
SS removal 99.99%
Bacteria&Virus removal 99.99%
Product Size(mm) ф200x1475
Type Inside-out Hollow Fiber
Material Alloy PVC
Hollow fiber I/O diameter 1.0/1.66
Spec. NWCO(Dalton) 100.000
2 28
Filter Area (m )
Fiber Qty 8000pcs
Housing Material UPVC
Seal material of fiber Epoxy Resin
Recommended TMP(Mpa) 0.04-0.08
Max.operating Pressure (Mpa) 0,3
Max.TMP(Mpa) 0,2
Max.backwash TMP(Mpa) 0,15
Operation
Temp. 5-45℃
Condition
PH range 2-13
Continuous Chlorine Resistance 100PPm
Discontinuous Chlorine Resistance 200PPm
Piping Type Cross-Flow or Dead End
Backward Flushing Flowrate(L/m².h) 2-3 times of output flowrate
Backward Flushing TMP (Mpa) 0.08-0.15
Backward Flushing Time 20-180s
Backward Flushing Cycle 20-60min.
Forward Flushing Flowrate(L/m².h) 1.5-2 times of output flowrate
Maintanance
Forward Flushing Time 10-30s
Forward Flushing Cycle 10-60min
Chemicals Flushing Cycle 60-180days
Chemicals Flushing Time 15-120min
Suitable Cleaning Chemicals Citric Acid、NaOH / NaClO、H2O2