PCB Terminal Blocks

and Connectors for Power Electronics


More Power on Your PCB
MORE POWER
ON YOUR PCB
More Power no Longer Means More Space!

The trend toward electronic minia- Every Advantage – All in One WAGO‘s lever-equipped MCS Thanks to WAGO‘s innovative spring
turization requires that both power MAXI 6 and MAXI 16 Connectors pressure connection technology,
and signal levels be integrated on WAGO combines all these criteria enable intuitive actuation without our PCB terminal blocks and
PCBs. The results: Increased power into a comprehensive and varied tools for simple, secure in-hand connectors for all applications ide-
density requiring connection tech- range of PCB terminal blocks and wiring. ally blend ergonomics and safety.
nologies suited for both compact connectors for power electronics. Push-in CAGE CLAMP® enables
and high-performance PCB terminal WAGO‘s PCB terminal blocks can be Both PCB terminal blocks and solid and ferruled conductors to be Advantages:
blocks and connectors. operated via lever or operating tool. connectors also offer a unique connected by simply pushing them • Comprehensive product range:
space-saving feature: Beyond their into the unit, while guaranteeing 0.2 … 25 mm² (24–4 AWG)
Connection technology is also a A multitude of variants are available nominal cross section, they connect secure and maintenance-free • Push-in CAGE CLAMP® termination of both
basic criterion for selecting the right in various pin spacings allowing most solid and fine-stranded connections for all conductor types. solid and ferruled conductors
terminal block/connector in deman- currents up to 101 A (IEC) or 85 A conductors up to the next larger Furthermore, our products are not • Wider conductor range and
ding applications, such as power (UL) and voltages up to 1000 V (IEC) cross section size. This saves space only simple and easy to use, but higher current carrying capacity
supplies, frequency inverters or ser- or 600 V (UL) to be transmitted in on the PCB and reduces device also offer maximum wiring flexibility. • Conductor connection and mating direction
vo drives. Additional decisive factors double-pinning configuration. connection costs. both horizontal and vertical to the PCB
include simple and easy operation, • Testing both parallel and perpendicular to
as well as wiring flexibility. Learn more at: conductor entry
www.wago.com/powerelectronics

3
2
PCB TERMINAL BLOCKS WITH PCB TERMINAL BLOCKS WITH
Push-in CAGE CLAMP® Push-in CAGE CLAMP® AND LEVER
2624, 2626, 2636 Series 2604, 2606, 2616 Series

WAGO’s PCB terminal blocks with Push-in CAGE Advantages: WAGO’s lever-equipped PCB terminal blocks offer Advantages:
CLAMP® are ideal for compact device connec- faster and easier wiring. They combine a compact
tions. They are compatible with existing industrial • Compact device connection design, high current carrying capacity and the ad- • The lever engages and keeps the clamping
solutions and can be perfectly integrated into both • Ideal for panel feedthrough and vantages of Push-in CAGE CLAMP® with the ben- point open, freeing hands for quick and easy
space-limited and panel feedthrough applications. space-restricted applications efits of intuitive lever operation. The lever permits wiring.
• Operation parallel to conductor entry 100% tool-free operation and provides a secure • The lever position clearly signals whether
Push-in CAGE CLAMP® is suitable for all conduc- • Compatibility with existing connection when the easy-to-use lever closes the the clamping point is open or closed.
tor types and enables solid and ferruled conduc- industrial solutions clamping unit. The lever also clearly locks in po- • All conductor types can be connected and
tors to be connected by simply pushing them into • For applications complying with EN and sition (open/close) with a tactile and audible click. disconnected without tools.
the unit. Tool-actuated termination is performed UL 61800-5-1 (details upon request) WAGO’s PCB terminal blocks with levers terminate • Push-in CAGE CLAMP® termination of both
parallel to conductor entry. WAGO’s PCB terminal conductors both horizontally and vertically to the solid and ferruled conductors
blocks terminate conductors both horizontally and PCB. Furthermore, they can be tested both parallel • Connection is secured when easy-to-use le-
vertically to the PCB. Furthermore, they can be and perpendicular to conductor entry. ver is quickly and simply lowered into closed
tested both parallel and perpendicular to position.
conductor entry.

Conductor Range: Conductor Range:

[mm2] 0.2 0.34 0.5 0.75 1.5 2.5 4 6 10 16 25 [mm2] [mm2] 0.2 0.34 0.5 0.75 1.5 2.5 4 6 10 16 25 [mm2]
2624 Series All conductor types “s” + “f-st” Pin spacing: 5 / 7.5 / 11.5 mm 2604 Series All conductor types “s” + “f-st” Pin spacing: 5 / 7.5 / 11.5 mm

2626 Series All conductor types “s” + “f-st” Pin spacing: 7.5 mm / 12.5 mm 2606 Series All conductor types “s” + “f-st” Pin spacing: 7.5 mm / 12.5 mm
2636 Series All conductor types “f-st” Pin spacing: 10 mm / 15 mm 2616 Series All conductor types “f-st” Pin spacing: 10 mm / 15 mm

[AWG] 24 22 20 18 16 14 12 10 8 6 4 [AWG] [AWG] 24 22 20 18 16 14 12 10 8 6 4 [AWG]

All conductor types including ferruled without restriction “s” Only solid conductors “f-st” Only fine-stranded conductors All conductor types including ferruled without restriction “s” Only solid conductors “f-st” Only fine-stranded conductors

5
4
PCB TERMINAL BLOCKS PCB TERMINAL BLOCKS
2624 Series 2604 Series

• PCB terminal block with • PCB terminal block with lever and
tool-actuation and Push-in CAGE CLAMP®
Push-in CAGE CLAMP® • Connection is secured when
• Straight or angled type easy-to-use lever is quickly and
• Ideal for panel feedthrough appli- simply lowered into closed
cations via operation parallel to position.
conductor entry • Straight or angled type

Push-in termination of solid Insert fine-stranded conductors and PCB terminal block for panel feed- Push-in termination of solid Insert fine-stranded conductors PCB terminal block for power
conductors remove all conductor types via oper- through connections conductors – and remove all conductors – supplies
ating tool. via operating tool.

0.9 0.9
2624 Series 2604 Series

Pin spacing 5 mm 7.5 mm 11.5 mm Conductor Data Pin spacing 5 mm 7.5 mm 11.5 mm Conductor Data

Ratings per IEC/EN 60664-1 Connection technology Push-in CAGE CLAMP® Ratings per IEC/EN 60664-1 Connection technology Push-in CAGE CLAMP®

21.3
16.3

16.3

18.4

18.4
Conductor range: Conductor range:
Nominal voltage (III / 3) 320 V 630 V 1000 V 0.2 … 6 mm² Nominal voltage (III / 3) 320 V 630 V 1000 V 0.2 … 4 mm²
solid solid

4
Conductor range: Conductor range:

4
Rated voltage (III / 2) 400 V 630 V 1000 V 0.2 … 6 mm² 1.5 1.5 Rated voltage (III / 2) 400 V 630 V 1000 V 0.2 … 4 mm²
fine-stranded 1 1 0.8 0.8 fine-stranded 1 1 1.5 1.5 0.8 0.83.6 3.6
Pin spacingPin spacing 2.75 2.75
Conductor range: 0.25 … 2.5 mm² Conductor range: 0.25 … 2.5 mm² Pin spacing Pin spacing 8.2 8.2
Nominal voltage (II / 2) 630 V 1000 V 1000 V Nominal voltage (II / 2) 630 V 1000 V 1000 V 3.8 3.8
fine-stranded (with insulated ferrule) 4.2 4.2 8.2 8.2 fine-stranded (with insulated ferrule)
16.7 16.7
11.5 11.5 15.4 15.4 12.4 12.4 25.8 25.8
Conductor range: 0.25 … 2.5 mm² Conductor range: 0.25 … 2.5 mm²
Rated surge voltage 4 kV 6 kV 8 kV Rated surge voltage 4 kV 6 kV 8 kV
fine-stranded (with uninsulated ferrule) fine-stranded (with uninsulated ferrule)

Rated current 32 A AWG 24 … 10 Rated current 32 A AWG 24 … 12 0.9 0.9

26 A 26 A 20 A 20 A
UL 1059 / Use Group C Strip length 10 … 12 mm / 0.39 … 0.47 inch UL 1059 / Use Group C Strip length 9 … 11 mm / 0.35 … 0.43 inch
15.4

15.4

150 V 600 V 300 V 600 V

25.7

25.7
Pole No. Item No. Pole No. Item No.

16.7

16.7
<__
Pin spacing 5 mm 7.5 mm 11.5 mm 5 mm 7.5 mm 11.5 mm Pin spacing 5 mm 7.5 mm 11.5 mm 5 mm 7.5 mm 11.5 mm 0,9
4

<_
<_
1 1 1.5 1.5 0.8 0.8
Angled Straight Angled Straight

16.7 >
16.3 >

<__ 25.7
4

4
Pin spacing Pin spacing 8.2 5.6 8.2 5.6
1 1 1.5 1.5 0.8 0.8
1 2624-1101 2624-3101 16.3 16.3 1 2604-1101 2604-3101
4.2 4.2
Pin spacing Pin spacing 8.2 8.2 5.2 5.2
>

>
)

2 2624-1102 2624-1302 2624-1502 2624-3102 2624-3302 2624-3502 11.5 11.5 2 2604-1102 2604-1302 2604-1502 2604-3102 2604-3302 2604-3502 3.8 3.8 16.3 16.3
)4

1.5 0.8

>4
1
12.41 1.5 19.20.8
) <__ <___ 19.2
3 2624-1103 2624-1303 2624-1503 2624-3103 2624-3303 2624-3503 3 2604-1103 2604-1303 2604-1503 2604-3103 2604-3303 2604-3503 12.4 _____>
) <__ ) <_ <_2.75 > <___
>
>5 <___ ) 5
> <__ ) 5.2
3.8 ) 8.2 )
_____>
4.2
8.2 <
<
4 2624-1104 2624-1304 2624-1504 2624-3104 2624-3304 2624-3504 4 2604-1104 2604-1304 2604-1504 2604-3104 2604-3304 2604-3504
Footprint (top view) Footprint (top view)
> <__ >
> <___
> > < L > 16.3 >
L> 15.4 > >
19.2 >
5 2624-1105 2624-1305 2624-1505 2624-3105 2624-3305 2624-3505 5 2604-1105 2604-1305 2604-1505 2604-3105 2604-3305 2604-3505 < 2.7
2.3
__> <___
6 2624-1106 2624-1306 2624-1506 2624-3106 2624-3306 2624-3506 > 6 2604-1106 2604-1306 2604-1506 2604-3106 2604-3306 2604-3506

) <__

<
8.2 <
> <___
>

7 2624-1107 2624-1307 2624-1507 2624-3107 2624-3307 2624-3507 7 2604-1107 2604-1307 2604-1507 2604-3107 2604-3307 2604-3507

<_____
2.7
> <__

2.9
Ø 1.3
> 8.2

Ø 1.3
8 2624-1108 2624-1308 2624-1508 2624-3108 2624-3308 2624-3508 8 2604-1108 2604-1308 2604-1508 2604-3108 2604-3308 2604-3508

<
>
9 2624-1109 2624-1309 2624-1509 2624-3109 2624-3309 2624-3509 > 5 9 2604-1109 2604-1309 2604-1509 2604-3109 2604-3309 2604-3509
5 <
<
10 2624-1110 2624-1310 2624-1510 2624-3110 2624-3310 2624-3510 10 2604-1110 2604-1310 2604-1510 2604-3110 2604-3310 2604-3510

11 2624-1111 2624-1311 2624-1511 2624-3111 2624-3311 2624-3511 Learn more at: 11 2604-1111 2604-1311 2604-1511 2604-3111 2604-3311 2604-3511 Learn more at:
12 2624-1112 2624-1312 2624-1512 2624-3112 2624-3312 2624-3512 www.wago.com/2624 12 2604-1112 2604-1312 2604-1512 2604-3112 2604-3312 2604-3512 www.wago.com/2604
7
6
PCB TERMINAL BLOCKS PCB TERMINAL BLOCKS
2626 Series 2606 Series

• PCB terminal block with • PCB terminal block with lever and
tool operation and Push-in CAGE CLAMP®
Push-in CAGE CLAMP® • Connection is secured when
• Straight or angled type easy-to-use lever is quickly and
• Ideal for panel feedthrough appli- simply lowered into closed
cations via operation parallel to position.
conductor entry • Straight or angled type

Push-in termination of solid Insert fine-stranded conductors and PCB terminal block for panel feed- Push-in termination of solid Insert fine-stranded conductors PCB terminal block for power sup-
conductors remove all conductor types via oper- through connections conductors – and remove all conductors – plies
ating tool. via operating tool.

1.8
1.35 1.5

2626 Series 2606 Series

Pin spacing 7.5 mm 12.5 mm Conductor Data Pin spacing 7.5 mm 12.5 mm Conductor Data

27
24.15

23.7
Ratings per IEC/EN 60664-1 Connection technology Push-in CAGE CLAMP® Ratings per IEC/EN 60664-1 Connection technology Push-in CAGE CLAMP®

Conductor range: Conductor range:


Nominal voltage (III / 3) 800 V 1000 V 0.2 … 10 mm² Nominal voltage (III / 3) 800 V 800 V 0.2 … 10 mm²
solid solid

4
4
1.5 3.45 1.2 3.8
Conductor range: 1.5 2.8 1 Conductor range: T 12.5
Rated voltage (III / 2) 1000 V 1000 V 0.2 … 10 mm² Rated voltage (III / 2) 1000 V 1000 V 0.2 … 10 mm²
fine-stranded T 2.6 14 fine-stranded L 24
L 18.5 36.7

Conductor range: 0.25 … 6 mm² Conductor range: 0.25 … 6 mm²


Nominal voltage (II / 2) 1000 V 1000 V Nominal voltage (II / 2) 1000 V 1000 V
fine-stranded (with insulated ferrule)
1.8 fine-stranded (with insulated ferrule)
1.35 1.5
Conductor range: 0.25 … 6 mm² Conductor range: 0.25 … 6 mm²
Rated surge voltage 8 kV 8 kV Rated surge voltage 8 kV 8 kV
fine-stranded (with uninsulated ferrule) fine-stranded (with uninsulated ferrule)

36.7
19.6

Rated current 41 A 41 A AWG 24 … 8 Rated current 41 A 41 A AWG 24 … 8

24
38 A 38 A 31 A
UL 1059 / Use Group C Strip length 13 … 15 mm / 0.51 … 0.59 inch UL 1059 / Use Group C Strip length 11 … 13 mm / 0.43 … 0.51 inch
4

600 V 600 V 1 600 V


1.5 2.8

4
13.2 9.05
Pole No. Item No. T
Pole No. Item No. 1.5 3.45
1.2

<_____
L 24.15 12.5 6.5
1.8 T
7.5 mm 12.5 mm 7.5 mm 12.5 mm 7.5 mm 12.5 mm 7.5 mm 12.5 mm 1,35
<__ <_ 1,5 1.35 21 1.5
< 1.8 <_L <__ 24.3

T = Pin spacing T = Pin spacing

<__
Angled Straight <___ Angled Straight

<_____ 36,7
<

36.7
19.6

1 2626-1101 2626-3101 L = T x P + 1.8 1 2606-1101 2606-3101 L = T x P + 1.5


< 19.6

<__ 24

24
2 2626-1102/0020-0000 2626-1352 2626-3102/0020-0000 2626-3352 2 2606-1102/0020-0000 2606-1352 2606-3102/0020-0000 2606-3352

4 <_
4<

1.5 (2.7) 1
3 2626-1103/0020-0000 2626-1353 2626-3103/0020-0000 2626-3353 1.5 (2.7) 1 3 2606-1103/0020-0000 2606-1353 2606-3103/0020-0000 2606-3353 1,2 <__
<

<____ < <__


1,5 3,45

<
< <___ < <
<
7.5 < 13.2 ) 12.5
) 13.2 <
1.5
<
12,5)
)
<___ (3.5) 1.2
4 2626-1104/0020-0000 2626-1354 2626-3104/0020-0000 2626-3354 4 2606-1104/0020-0000 2606-1354 2606-3104/0020-0000 2606-3354
< <__
Footprint (top view) Footprint (top
7,5 <
view) 6,5
<
L 24.2 21
<___ L <_ 24.2
<___ <_ <_
<___ L
<___
<_
<_12.5
<_
5 2626-1105/0020-0000 2626-1355 2626-3105/0020-0000 2626-3355 Ø2 5 2606-1105/0020-0000 2606-1355 2606-3105/0020-0000 2606-3355 24,3
6.6 Ø2 6.6 5.6
< <__ L
<_ ) <__ 7.5 < Ø 2
6 2626-1106/0020-0000 2626-1356 2626-3106/0020-0000 2626-3356 6 2606-1106/0020-0000 2606-1356 2606-3106/0020-0000 2606-3356
) <
) <__

<__
)

2
2
13.2

13.2

12.5)
7 2626-1107/0020-0000 2626-1357 2626-3107/0020-0000 2626-3357 7 2606-1107/0020-0000 2606-1357 2606-3107/0020-0000 2606-3357
1.9
1.9

12.5
8 2626-1108/0020-0000 2626-1358 2626-3108/0020-0000 2626-3358 8 2606-1108/0020-0000 2606-1358 2606-3108/0020-0000 2606-3358
<

)
9 2626-1109/0020-0000 2626-1359 2626-3109/0020-0000 2626-3359 9 2606-1109/0020-0000 2606-1359 2606-3109/0020-0000 2606-3359
<
7.5< 12.5 Ø2
12.5
10 2626-1110/0020-0000 2626-1360 2626-3110/0020-0000 2626-3360 10 2606-1110/0020-0000 2606-1360 2606-3110/0020-0000 2606-3360 5.5

11 2626-1111/0020-0000 2626-1361 2626-3111/0020-0000 2626-3361 Learn more at: 11 2606-1111/0020-0000 2606-1361 2606-3111/0020-0000 2606-3361 Learn more at:
12 2626-1112/0020-0000 2626-1362 2626-3112/0020-0000 2626-3362 www.wago.com/2626 12 2606-1112/0020-0000 2606-1362 2606-3112/0020-0000 2606-3362 www.wago.com/2606
9
8
PCB TERMINAL BLOCKS PCB TERMINAL BLOCKS
2636 Series 2616 Series

• PCB terminal block with • PCB terminal block with lever and
tool operation and Push-in CAGE CLAMP®
Push-in CAGE CLAMP® • Connection is secured when
• Straight or angled type easy-to-use lever is quickly and
• Ideal for panel feedthrough appli- simply lowered into closed
cations via operation parallel to position.
conductor entry • Straight or angled type

Push-in termination of solid Insert fine-stranded conductors and PCB terminal block for panel feed- Push-in termination of solid Insert fine-stranded conductors PCB terminal block for power
conductors remove all conductor types via oper- through connections conductors – and remove all conductors – supplies
ating tool. via operating tool.
1.3 1.3 1.5 1.5

2636 Series 2616 Series

Pin spacing 10 mm 15 mm Conductor Data Pin spacing 10 mm 15 mm Conductor Data

34.2

34.2
30

30
31.3
Ratings per IEC/EN 60664-1 Connection technology Push-in CAGE CLAMP® Ratings per IEC/EN 60664-1 Connection technology Push-in CAGE CLAMP®

Conductor range: Conductor range:


Nominal voltage (III / 3) 1000 V 800 V 0.75 … 16 mm² Nominal voltage (III / 3) 1000 V 1000 V 0.75 … 16 mm²
solid solid

4
1.2 1.2 2.5 2.5 2.1 2.1 1.2 1.2 4 4
Conductor range: 1.2 2.5 2.33 1 3.95 Conductor range: 15 15
Rated voltage (III / 2) 1000 V 1000 V 0.75 … 25 mm² Rated voltage (III / 2) 1000 V 1000 V 0.75 … 25 mm² T 5T 5
fine-stranded T 5 15 fine-stranded 29.4 29.4
L 24.8 L L 46 46

Conductor range: 0.75 … 16 mm² Conductor range: 0.75 … 16 mm²


Nominal voltage (II / 2) 1000 V 1000 V Nominal voltage (II / 2) 1000 V 1000 V
fine-stranded (with insulated ferrule) fine-stranded (with insulated ferrule)

Conductor range: 0.75 … 16 mm² Conductor range: 0.75 … 16 mm² 1.3 1.3 1.5 1.5
Rated surge voltage 8 kV 8 kV Rated surge voltage 8 kV 8 kV
fine-stranded (with uninsulated ferrule) fine-stranded (with uninsulated ferrule)
28.6

49.8

49.8
Rated current 76 A 76 A AWG 18 … 4 Rated current 76 A 76 A AWG 18 … 4

33.2

33.2
66 A 66 A 1,35 1,5
UL 1059 / Use Group C Strip length 18 … 20 mm / 0.71 … 0.79 inch UL 1059 / Use Group C Strip length 18 … 20 mm / 0.71 … 0.79 inch
600 V 600 V
4

1.2 2.5 1.6 1

Pole No. Item No. Pole No. Item No.

49,8
T 5 2.33 15 11.5

L 29.1

4
10 mm 15 mm 10 mm 15 mm 10 mm 15 mm 10 mm 15 mm 1,3 1.2 1.2
<__ 2.5
<_ 1,5
2.5 2.1 2.1 1.2 1.2
<_T <__
28,6

15 15 10.2 10.2

T = Pin spacing
T
5 5
<_

<__
Angled Straight Angled Straight 27.8 27.8

<__
L L
32 32

L = T x P + 1.6
<_ 28.6

1 2636-1101 2636-3101 1 2616-1101 2616-3101


T = Pin spacing

<__ 34,2
) 4 <__ 30
4

2 2636-1102/0020-0000 2636-1352 2636-3102/0020-0000 2636-3352 2 2616-1102/0020-0000 2616-1352 2616-3102/0020-0000 2616-3352


L = T x P + 1.5
4<

1,2 1,6 1 1,2 2,5


3 2636-1103/0020-0000 2636-1353 2636-3103/0020-0000 2636-3353 1.2
<___ < 1.6 1 < 2,5 3 2616-1103/0020-0000 2616-1353 2616-3103/0020-0000 2616-3353 2,1
<

< <__ < 15 11,5 15 5


2.5 2,33 1,2 2,5 2,1 1,2
4<
< <_
<_
1515
) 5<
) 11.5 29,1 <___
4 2636-1104/0020-0000 2636-1354 2636-3104/0020-0000 2636-3354 4 2616-1104/0020-0000 2616-1354 2616-3104/0020-0000 2616-3354 15 ) L
Footprint
) 10 5(top <___
view) Footprint
10 5 <_(top view) <_ 29,4
<
2.33 <
<) < <_ ) <__ )
<_ 29.1 L
<_ < <_

<____ L
<____
<____ L <______ 46
<____ <_____
5 2636-1105/0020-0000 2636-1355 2636-3105/0020-0000 2636-3355 4,3 Ø 1,7 5 2616-1105/0020-0000 2616-1355 2616-3105/0020-0000 2616-3355 4,4 Ø 1,7
4.3 Ø 1.7 < Ø 1.7 <
6 2636-1106/0020-0000 2636-1356 2636-3106/0020-0000 2636-3356 6 2616-1106/0020-0000 2616-1356 2616-3106/0020-0000 2616-3356
<____
15 <
) <__

) <__ <____
2,6
2.6

15

2,6
7 2636-1107/0020-0000 2636-1357 2636-3107/0020-0000 2636-3357 7 2616-1107/0020-0000 2616-1357 2616-3107/0020-0000 2616-3357

15
15 )
<

8 2636-1108/0020-0000 2636-1358 2636-3108/0020-0000 2636-3358 8 2616-1108/0020-0000 2616-1358 2616-3108/0020-0000 2616-3358

)
<
9 2636-1109/0020-0000 2636-3109/0020-0000 2,5 9 2616-1109/0020-0000 2616-3109/0020-0000
<_ <
2.5
<
10 5 <
<__
2.5 2,5
15 5 <
10 5 <
10 2636-1110/0020-0000 2636-3110/0020-0000 10 2616-1110/0020-0000 2616-3110/0020-0000
15 5
11 2636-1111/0020-0000 2636-3111/0020-0000 Learn more at: 11 2616-1111/0020-0000 2616-3111/0020-0000 Learn more at:
12 2636-1112/0020-0000 2636-3112/0020-0000 www.wago.com/2636 12 2616-1112/0020-0000 2616-3112/0000-0020 www.wago.com/2616
11
10
LEVERAGE
CONVENIENCE
Pluggable PCB Connectors with Levers –
Connect Conductors up to 25 mm² (4 AWG)

For wiring assemblies in the a premium: Beyond their specific the enclosure. Complicated adjust- 100% Safety
field, highly accessible and sim- nominal cross-section, the PCB ments to the enclosure cutout are
ple-to-operate connection points connectors connect fine-stranded no longer required. Another unique As with all MCS products, the
are essential. WAGO is literally conductors up to 10 or 25 mm² (8 feature is the ability to quickly pluggable connectors also provide Advantages:
leveraging its expertise with the or 4 AWG). Connection with Push-in and easily recode when plugged 100% protection against mismating
• The lever engages and keeps the clamping point open,
MCS MAXI 6 and MCS MAXI 16 to CAGE CLAMP® is suitable for all in. To keep installation simple and to ensure maximum safety for field
freeing hands for quick and easy wiring.
offer the world’s first pluggable conductor types and enables solid minimize the number of assemblies, wiring. The integrated protective
• All conductor types can be connected and disconnected
connectors with levers for intuitive, and fine-stranded conductors with both male headers and female contact caps within the interface
without tools.
tool-free usage. With this feature, ferrules to be connected by simply connectors feature the same sym- of the MCS MAXI 16 Male Headers
• Product range: 0.2 … 25 mm²
connectors can be wired in-hand pushing them into the unit. metrically formed coding fingers. ensure additional user safety when
• Push-in CAGE CLAMP® termination of both solid and
easily and quickly. Furthermore, unplugged.
ferruled conductors
simply lowering the lever always Flexible Coding – MCS MAXI 6 Connectors are also
• Wider conductor range and
ensures a reliable contact. Ready to Adapt easy to code. Depending on the Yet another highlight: An optional
higher current carrying capacity
version, separate coding pins are interlock enables fast, reliable con-
• 100% protected against mismating
Both wire-to-wire and wire-to- The coding of the new MCS available or the coding pins can be nection and also prevents accidental
• Coding and locking options available
board versions of pluggable PCB MAXI 16 Connectors brings ad- broken off directly from the female disconnection.
connectors are available and de- ditional benefits: They are coded connector and inserted into the
signed for a nominal cross-section internally, simplifying individual corresponding male header.
of 6 or 16 mm² (10 or 6 AWG). The coding changes – even when the Learn more at:
top advantage where space is at connector is already installed in www.wago.com/powerelectronics

13
12
MCS MAXI 6 MCS MAXI 6
1-Conductor Female Connectors with Levers 1-Conductor Male Connectors with Levers

• Female connectors with levers • Male connectors with levers


and Push-in CAGE CLAMP® and Push-in CAGE CLAMP®
• Variants with and without locking • For wire-to-wire applications
• Push-in CAGE CLAMP® termination of both solid • Push-in CAGE CLAMP® termination of both solid
and ferruled conductors and ferruled conductors
• Test slot 0° and 90° to conductor entry • Test slot 0° and 90° to conductor entry
• Connection is secured when easy-to-use lever is • Connection is secured when easy-to-use lever is
quickly and simply lowered into closed position. quickly and simply lowered into closed position.

831-110x Series 831-120x Series

Pin spacing 7.62 mm Conductor Data Pin spacing 7.62 mm Conductor Data

Ratings per IEC/EN 60664-1 Connection technology Push-in CAGE CLAMP® Ratings per IEC/EN 60664-1 Connection technology Push-in CAGE CLAMP®

Conductor range: Conductor range:


Nominal voltage (III / 3) 800 V 0.2 … 10 mm² Nominal voltage (III / 3) 800 V 0.2 … 10 mm²
solid solid
<___ 45.7
<___
<____ 45.7
<____
Conductor range: Conductor range: <
<23.7
<
Rated voltage (III / 2) 1000 V 0.2 … 10 mm² <23.7 Rated voltage (III / 2) 1000 V 0.2 … 10 mm²
fine-stranded fine-stranded

<__
<__

Conductor range: 0.25 … 6 mm² Conductor range: 0.25 … 6 mm²


Nominal voltage (II / 2) 1000 V Nominal voltage (II / 2) 1000 V

<
<__ 37.5
fine-stranded (with insulated ferrule) fine-stranded (with insulated ferrule)
<

<__ 37.6

< 25
Conductor range: 0.25 … 6 mm² Conductor range: 0.25 … 6 mm²
< 25

Rated surge voltage 8 kV Rated surge voltage 8 kV


fine-stranded (with uninsulated ferrule) fine-stranded (with uninsulated ferrule)
<
< 27.2
<
< < T <
Rated current 41 A AWG 24 … 8 < 27.2 Rated current 41 A AWG 24 … 8 <___ 46
<___
T <
<__ 42.5
<__
Strip length 11 … 13 mm / 0.43 … 0.51 inch Strip length 11 … 13 mm / 0.43 … 0.51 inch

Pole No. Item No. Pole No. Item No.

1-conductor female connector;


1-conductor female connector; light gray
with locking levers; light gray P = Number of poles 1-conductor male connector; light gray P = Number of poles
2 831-1102 831-1102/037-000 T = Pin spacing 2 831-1202 T = Pin spacing
3 831-1103 831-1103/037-000 L = T x P + 1.88 3 831-1203
<___ L
<___ L = T x P + 2.88
<___ L
<___
4 831-1104 831-1104/037-000 4 831-1204

5 831-1105 831-1105/037-000 5 831-1205

6 831-1106 831-1106/037-000 6 831-1206

7 831-1107 831-1107/037-000 7 831-1207

8 831-1108 831-1108/037-000 8 831-1208


Learn more at: Learn more at:
9 831-1109 831-1109/037-000 9 831-1209
www.wago.com/831 www.wago.com/831

15
14
MCS MAXI 6
THT Male Headers

• Soldered male headers


may be mounted horizontally
or vertically via straight or angled solder pins
• Three solder pins per pole provide high electrical
and mechanical stability
• 100% protected against mismating
• Coding options available

5.25 > 5.2 >


> <___

>14.8 >
(_14.8 _)

4 ) 12.8 )
(_12.8_)
1 0.4
> )
>< 0.4 >>
1.2
1 __> <
1.2 > 7.62 6.5 > >)

>
5.08 5.08
5.08
_> <
5.08 <_______ L _______> > >

4
<
___> <___

____________

>____ 29 ____>
29
__________
Easy coding via coding star Coding star (Item No. 831-500)

>_
L
<_______ _______>

831-36xx Series
L = (pole no. – 1) x pin spacing + 10.5 mm L = (pole no. – 1) x pin spacing + 10.5 mm
Pin spacing 7.62 mm Solder Pin Data

Ratings per IEC/EN 60664-1 Solder pin length 4 mm

Nominal voltage (III / 3) 500 V Solder pin dimensions 1 x 1.2 mm


Footprint (top view) Footprint (top view)
Drilled hole diameter
Rated voltage (III / 2) 630 V 1.7+0.1 mm
with tolerance

Ø 1.7+0.1
<_______
Nominal voltage (II / 2) 1000 V

<_
1
Ø 1.7+0.1
<_______
2.32
<____
Rated surge voltage 6 kV

(
5.08
Rated current 41 A

(
(

<
(

(
<
508
(
(
(

Pole No. Item No. 3.96


< <____ 7.62
< <____
THT male header;
THT male header; 7.62 6.52
with solder pins angled downwards; <____ <
with straight solder pins; light gray < <_____
light gray

2 831-3602 831-3622

3 831-3603 831-3623

4 831-3604 831-3624

5 831-3605 831-3625

6 831-3606 831-3626

7 831-3607 831-3627

8 831-3608 831-3628
Learn more at:
9 831-3609 831-3629 www.wago.com/831

17
16
MCS MAXI 16 MCS MAXI 16
1-Conductor Female Connectors with Levers 1-Conductor Male Connectors with Levers

• Female connectors with levers • Male connectors with levers


and Push-in CAGE CLAMP® and Push-in CAGE CLAMP®
• Variants with and without locking • For wire-to-wire applications
• Push-in CAGE CLAMP® termination of both solid • Push-in CAGE CLAMP® termination of both solid
and ferruled conductors and ferruled conductors
• Test slot 0° and 90° to conductor entry • Test slot 0° and 90° to conductor entry
• Connection is secured when easy-to-use lever is • Connection is secured when easy-to-use lever is
quickly and simply lowered into closed position. quickly and simply lowered into closed position.

832-110x Series 832-120x Series

Pin spacing 10.16 mm Conductor Data Pin spacing 10.16 mm Conductor Data

Ratings per IEC/EN 60664-1 Connection technology Push-in CAGE CLAMP® Ratings per IEC/EN 60664-1 Connection technology Push-in CAGE CLAMP®

Conductor range: <___ 49.9


<___ Conductor range:
Nominal voltage (III / 3) 1000 V 0.75 … 16 mm² Nominal voltage (III / 3) 1000 V 0.75 … 16 mm² <__ 50.2
<__
solid solid
<
<27.7
<27.7
<

Conductor range: Conductor range:

<__
<__

Rated voltage (III / 2) 1000 V 0.75 … 25 mm² Rated voltage (III / 2) 1000 V 0.75 … 25 mm²
fine-stranded fine-stranded

<__ 45.2
<
<

<__ 45.2

16.5 <
Conductor range: 0.75 … 16 mm² Conductor range: 0.75 … 16 mm²

< 29.1
< 29.1

Nominal voltage (II / 2) 1000 V Nominal voltage (II / 2) 1000 V


fine-stranded (with insulated ferrule) fine-stranded (with insulated ferrule)

Conductor range: Conductor range: 5.7

<
0.75 … 16 mm² 0.75 … 16 mm²
<
< 30.7
<
T <
( <__
Rated surge voltage 8 kV Rated surge voltage 8 kV (T <
fine-stranded (with uninsulated ferrule) fine-stranded (with uninsulated ferrule)
<__ 46.5
<__
<__ 45.7
<__
1
<_
<
< 1
<_
Rated current 76 A AWG 18 … 4 Rated current 76 A AWG 18 … 4

66 A 66 A
UL 1059 / Use Group C Strip length 18 … 20 mm / 0.71 … 0.79 inch UL 1059 / Use Group C Strip length 18 … 20 mm / 0.71 … 0.79 inch
600 V 600 V
P = Number of poles P = Number of poles
Pole No. Item No. Pole No. Item No.
T = Pin spacing T = Pin spacing
1-conductor female connector;
1-conductor female connector; light gray <___ L L = T x P + 1.3 1-conductor male connector; light gray L = T x P + 1.3
<___
with locking levers; light gray <__ L
<__

2 832-1102 832-1102/037-000 2 832-1202

3 832-1103 832-1103/037-000 3 832-1203

4 832-1104 832-1104/037-000 4 832-1204

5 832-1105 832-1105/037-000 Learn more at: 5 832-1205 Learn more at:


6 832-1106 832-1106/037-000 www.wago.com/832 6 832-1206 www.wago.com/832

19
18
MCS MAXI 16
THT Male Headers

• Soldered male headers may be mounted


horizontally or vertically via straight
or angled solder pins
• Three solder pins per pole provide high
electrical and mechanical stability
• 100% protected against mismating
• Coding options available

< 10.16
<_____
5.08
<____
5.7 □ 1.2 <
) T<
) <___ <
<___ 2.24
<___
< 10.16
< <_____
1 2 3 4

16.5 < 16.5 <


16.5 <
16.5 <
5.08
<____
5.7 □ 1.2 <
) T<
) <___ <
<___ 2.24
<___
<
1 2 3 4
1 2 3 4

<
<
<

4<
5.7 □ 1.2
T<

<
) <___ <
) <___ 2.24
<___

4
<

<
5.08

<
<___
5 .7 □ 1.2
<____

<_
< <
) T< 5.08
) <___ <
<___ <____ < 10.16
< 10.16 <_____
1 2 3 4 3.17

<_ 32 <_ 32
<
<_____

<_
<_

<_
1 1 T = Pin spacing

<_ 32

<_ 32
<___ L
<_ <___
<_
L = T x P + 1.3
1 1 1 1 1 1
<___ L
<_ <___
<___ L <___ L
<_ <___ <_ <___
<_ <_ <_

MCS MAXI 16 is ideal for enclo- Easy coding thanks to symmetrical Coding star (Item No. 832-500)
sure cutouts. coding keys in both male and female
connectors Footprint (top view) Footprint (top view) Footprint (top view)

2.24
2.24
<____
3.17

<____
<____

5.08
5.08
5.08

<____
<____
<____

Ø 1.7+0.1
Ø 1.7+0.1

<_______
<_______
1 2 n 1 2 n 1 2 n

<
<
832-36xx Series

<

<
<
<

<
<
Pin spacing 10.16 mm Solder Pin Data

<

<_____
<_____
<_____

<
<

10.16
10.16
10.16
Ratings per IEC/EN 60664-1 Solder pin length 4 mm 5.7
<_ ) T < ) Ø 1.7+0.1
) <_______
Nominal voltage (III / 3) 800 V Solder pin dimensions 1.2 x 1.2 mm
5.7
<_ ) T 5.7 <_ ) T
) < ) <
Drilled hole diameter
Rated voltage (III / 2) 1000 V 1.7
+0.1
mm
with tolerance

Nominal voltage (II / 2) 1000 V


Pole
Rated surge voltage 8 kV Cutouts for male headers Cutouts for male headers No.
X

Rated current 76 A with solder pins with solder pins (with locking levers) 2 24.1

3 34.2

4 44.4

(16.9 ± 0.1(
5 54.6

>___<
(16.9 ± 0.1(

± 0.1
13.5
Pole No. Item No. 6 64.7

THT male header; THT male header; with sol- THT male header; with sol- 2.3± 0.1
___< <____ X ± 0.1 ____<
with straight solder pins; der pins angled downwards der pins angled upwards <____ X ± 0.1 ____<
light gray light gray light gray

2 832-3602 832-3622 832-3642

3 832-3603 832-3623 832-3643

4 832-3604 832-3624 832-3644

5 832-3605 832-3625 832-3645


Learn more at:
6 832-3606 832-3626 832-3646
www.wago.com/832

21
20
Easy and intuitive
disconnection via inno-
vative locking levers

Coding

Easy coding thanks to


symmetrical coding
keys in both male and
female connectors

SYSTEM HIGHLIGHTS
Lever Actuation

Easy in-hand wiring via


lever actuation

Quick and simple Recoding even when


in-hand wiring plugged in

Locking Levers

Easy and secure plug-


ging with automatic
locking; optional lock-
ing levers prevent acci-
dental disconnection.

23
22
0888-0156/0103-6901 – POWER ELECTRONICS PCB 1.3 US – 02/2019 – Printed in Germany – Subject to design changes

WAGO Kontakttechnik GmbH & Co. KG


Postfach 2880 · 32385 Minden Headquarters +49 571/ 887 - 0
Hansastrasse 27 · 32423 Minden Sales +49 571/ 887 - 222
info@wago.com Orders +49 571/ 887 - 44333
www.wago.com Fax +49 571/ 887 - 8 44169

WAGO is a registered trademark of WAGO Verwaltungsgesellschaft mbH.


“Copyright – WAGO Kontakttechnik GmbH & Co. KG – All rights reserved. The content and structure of the WAGO websites, catalogs, videos and other WAGO media are subject to copy-
right. Distribution or modification to the contents of these pages and videos is prohibited. Furthermore, the content may neither be copied nor made available to third parties for commer-
cial purposes. Also subject to copyright are the images and videos that were made available to WAGO Kontakttechnik GmbH & Co. KG by third parties.”

You might also like