Glazed Elements - Fenestration Performance Requirements

Plot No. IC1-LOT-07 WARSAN 1 621


Project PROPOSED BUILDING 2B+G+4+2ROOF Total Wall Area 3596.769 m2
Consultant ALGAFRY Total Glazed Area 1077.6192 m2
Building Type Residential WWR 30.0%

Version-1, Jan 2022

Total Wall Area N- Northeast 22.5° ≤ α < 67.5° Total Wall Area
Orientation of glazed element North −22.5° ≤ α < 22.5°
Orientation m2
67.17 Orientation of glazed element NE&NW 1135.00
Northwest 292.5° ≤ α < 337.5° Orientations m2

Max Percentage of glazing per Max Percentage of glazing per


building elevation
≤ 80 % Total Glazed Area per the Elevation m 2
15.25 building elevation
≤ 70 % Total Glazed Area per the Elevation m 2
456.45
81% Percentage of glazing per elevation 71% Percentage of glazing per elevation
23% 40%
Comply Comply
Thermal Thermal
Height Width Item Area Shading Coefficient - Light Transmittance - Height Width Item Area Shading Coefficient - Light Transmittance -
Transmittance - U Transmittance - U
Glazing Reference Name/No. Qty SC LT % Glazing Reference Name/No. Qty SC LT %
m m m2 W/m2 K m m m2 W/m2 K
2.1 max 0.4 max 40% min 2.1 max 0.4 max 40% min

G6 3.10 4.92 15.25 1.0 1.70 0.20 0.45 W1A 1.20 2.00 2.40 1.0 1.70 0.20 0.45
W2A 1.20 1.80 2.16 4.0 1.70 0.20 0.45
W3A 1.20 1.20 1.44 4.0 1.70 0.20 0.45
W4A 1.20 1.00 1.20 1.0 1.70 0.20 0.45
FG2A 2.30 2.50 5.75 3.0 1.70 0.20 0.45
FG3A 2.30 2.00 4.60 7.0 1.70 0.20 0.45
FG4A 2.30 1.80 4.14 1.0 1.70 0.20 0.45
FG5A 2.30 1.50 3.45 4.0 1.70 0.20 0.45
SD1 2.20 2.50 5.50 29.0 1.70 0.20 0.45
SD3A 2.20 1.80 3.96 3.0 1.70 0.20 0.45
SD5A 2.20 1.20 2.64 3.0 1.70 0.20 0.45
G1 7.80 12.55 97.89 1.0 1.70 0.20 0.45
G2 3.10 24.97 77.41 1.0 1.70 0.20 0.45
G7 3.10 5.31 16.46 1.0 1.70 0.20 0.45

Southeast 112.5° ≤ α < 157.5°


East 67.5° ≤ α < 112.5° Total Wall Area Total Wall Area
Orientation of glazed element E&W Orientations 1174.91 Orientation of glazed element South 157.5° ≤ α < 202.5° SE&S&SW 1219.69
West 247.5° ≤ α < 292.5° m2 Orientations m2
Southwest 202.5° ≤ α < 247.5°
Max Percentage of glazing per Max Percentage of glazing per
building elevation ≤ 60 % Total Glazed Area per the Elevation m 2
157.24 building elevation ≤ 40 % Total Glazed Area per the Elevation m 2
448.68
61% Percentage of glazing per elevation 41% Percentage of glazing per elevation

13% 37%
Comply Comply
Thermal Thermal
Height Width Item Area Shading Coefficient - Light Transmittance - Height Width Item Area Shading Coefficient - Light Transmittance -
Transmittance - U Transmittance - U
Glazing Reference Name/No. Qty SC LT % Glazing Reference Name/No. Qty SC LT %
m m m2 W/m2 K m m m2 W/m2 K
2.1 max 0.4 max 40% min 2.1 max 0.4 max 40% min

W1A 1.20 2.00 2.40 4.0 1.70 0.20 0.45 W1A 1.20 2.00 2.40 5.0 1.70 0.20 0.45
FG3A 2.30 2.00 4.60 1.0 1.70 0.20 0.45 FG1A 2.30 2.70 6.21 12.0 1.70 0.20 0.45
FG7A 2.30 1.60 3.68 3.0 1.70 0.20 0.45 FG4A 2.30 1.80 4.14 4.0 1.70 0.20 0.45
SD1 2.20 2.50 5.50 20.0 1.70 0.20 0.45 FG5A 2.30 1.50 3.45 4.0 1.70 0.20 0.45
SD2A 2.20 2.00 4.40 5.0 1.70 0.20 0.45 FG7A 2.30 1.60 3.68 1.0 1.70 0.20 0.45
FG8A 2.30 0.87 2.00 1.0 1.70 0.20 0.45
SD1 2.20 2.50 5.50 28.0 1.70 0.20 0.45
SD2A 2.20 2.00 4.40 10.0 1.70 0.20 0.45
G3 3.10 18.75 58.13 1.0 1.70 0.20 0.45
G4 3.10 5.38 16.67 1.0 1.70 0.20 0.45
G5 3.10 6.91 21.42 1.0 1.70 0.20 0.45
SD4A 2.20 1.60 3.52 3.0 1.70 0.20 0.45
G3a 3.10 6.88 21.34 1.0 1.70 0.20 0.45

Orientation of glazed element Horizontal (Skylight) Total Roof Area m2


Consultant Comment
Total Glazed Area per the Elevation m2

Percentage of glazing

Thermal
Height Width Item Area Shading Coefficient - Light Transmittance -
Transmittance - U
Glazing Reference Name/No. Qty SC LT %
m m m2 W/m2 K