Professional Documents
Culture Documents
5.2.4 Report On Flatness of Glass After Tempering
5.2.4 Report On Flatness of Glass After Tempering
5.2.4 Report On Flatness of Glass After Tempering
2023
163 ltr
1 Overall Bow mm upper GDEL 671*516 0.50 Passed
213 ltr
2 Overall Bow mm lower 653*524.5 0.60 Passed
GDEL
Upto 1.2m
163 ltr length 4mm
3 Overall Bow mm lower 745.5*516 maximum 0.70 Passed
GDEL
213 ltr
4 Overall Bow mm lower 653*524.5 0.70 Passed
GDEL
126 ltr
5 Overall Bow mm 518*516 0.60 Passed
upper GDEL
Comments:
Prepared By Reviewed Approved By-1 Approved By-2 WALTON HI- TECH INDUSTRIES PLC.
Md. Al-Amin Chandra,Kaliakoir,Gazipur
ID: 37830 Dept Name Refrigerator R&I
Sr. Deputy Director
Section Chemical R&I
PAGE NO. 01 OF 03 Ref. No. RHRrRCHrAA01157 Sub Section
REPORT NAME Report on Flatness of Glass after Tempering DATE ISSUED 10.12.2023
213 ltr
1 Roller Wave mm lower GDEL 674*550 0.24 Passed
213 ltr.
2 Roller Wave mm Lower 653*524.5 0.22 Passed
GDXX
144 ltr
4 Roller Wave mm lower 745.5*516 0.26 Passed
GDEL
163 Ltr
5 Roller Wave mm 745.5*516 0.12 Passed
lower GDEL
Comments:
Prepared By Reviewed Approved By-1 Approved By-2 WALTON HI- TECH INDUSTRIES PLC.
Md. Al-Amin Chandra,Kaliakoir,Gazipur
ID: 37830 Dept Name Refrigerator R&I
Sr. Deputy Director
Section Chemical R&I
PAGE NO. 02 OF 03 Ref. No. RHRrRCHrAA01157 Sub Section
REPORT NAME Report on Flatness of Glass after Tempering DATE ISSUED 10.12.2023
213 ltr
1 Edge Lift mm lower GDEL 674*550 0.30 Passed
213 ltr.
2 Edge Lift mm Lower 653*524.5 0.32 Passed
GDXX
144 ltr
4 Edge Lift mm lower 745.5*516 0.26 Passed
GDEL
163 Ltr
5 Edge Lift mm 745.5*516 0.40 Passed
lower GDEL
Comments:
Prepared By Reviewed Approved By-1 Approved By-2 WALTON HI- TECH INDUSTRIES PLC.
Md. Al-Amin Chandra,Kaliakoir,Gazipur
ID: 37830 Dept Name Refrigerator R&I
Sr. Deputy Director
Section Chemical R&I
PAGE NO. 03 OF 03 Ref. No. RHRrRCHrAA01157 Sub Section