After Interpolating, Net ultimate bearing capacity=
= 1.461 Kg/cm2 SBC considering factor of safety of 2.5 = = 0.730 Kg/cm2 = 7.30 T/m2 CALCULATION OF SAFE BEARING CAPACITY (SBC) OF FOUNDATION SOIL COLLECTED DURING BORING FROM BH NO:-…….. AT R.L (+) …….M DEPTH FOR THE CONSTRUCTION OF PROPOSED ………………………………………………………………..
Cohesion=C = 0.31 Kg/cm2
Angle of shearing resistance f = 5 Degree f' = 3 Degree Bulk Density= 1.875 gms/cc Field moisture content= 24.2 % Dry density= g d= 1.510 gms/cc Specific gravity=Gs= 2.69 Void ratio=e = 0.78 (Loose) Saturated density= g s = 1.949 Submersible density =g sub = 0.949 gms/cc Depth Df = 1.5 m Width of footing= B= 2.0 m(Assumed) Over burden pressure q = (Df x gsub) /1000= 0.142 Kg/cm2 Bg =( Bxgsub)/1000= 0.190 Kg/cm2 Bearing capacity factors f & f' Nc &N'c Nq &N'q Ng & N'g 5 6.49 1.57 0.45 3 5.95 1.342 0.27 Sc = 1 Sq = 1 Sg = 1
dc = 1+0.2x(Df/B)x Tan (45+f/2) = 1.164
dq = dg = 1.000 ic = iq =ig = 1 w' = 0.5 In case of Local shear failure
= 0.739 Kg/cm2 = 7.39 T/m2 CALCULATION OF SAFE BEARING CAPACITY (SBC) OF FOUNDATION SOIL OF BORE HOLE NO-1 AT 4.5M DEPTH CONSTRUCTION OF BRIDGE OVER INDRABATI AT 18TH KM ON KODINGA CHIRIMA NATIGHAT ROAD
Field SPT value = 50
Depth Df = 6.0 m Corrected SPT value = 30.75 Corrected SPT value = 32.50 (As per IS-2131) Cohesion=C = 0.00 Kg/cm2 Angle of shearing resistance f = 34 Degree (As per IS 6403 1981) f' = 24 Degree Condition of the strata as per fig-1 of IS 6403-1981 = ---- (Loose) Submersible density =g sub = 0.877 gms/cc Depth Df = 6.00 m Width of footing= B= 2.0 m(Assumed) Over burden pressure q = (Df x gsub) /1000= 0.526 Kg/cm2 Bg =( Bxgsub)/1000= 0.175 Kg/cm2 Bearing capacity factors f Nc &N'c Nq &N'q Ng & N'g 34 42.924 30.32 42.9 24 19.542 9.808 9.782 Sc = 1 Sq = 1 Sg = 1
Calculation of Safe Bearing Capacity (SBC) of Foundation Soil Collected During Boring From BH No: - .. at R.L (+) .M Depth For The Construction of Proposed .
Amendment No. 2 November 2020 TO Is 13920: 2016 Ductile Design and Detailing of Reinforced Concrete Structures Subjected To Seismic Forces - Code of Practice