Product data sheet XCKJ105217H29

Characteristics Limit switches - Osisense XC Standard - type XCKJ


Metal with specific Head and Rod lever

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing o f the products with respect to the relevant specific application or use thereof.
Main characteristics
Range of product OsiSence XC
Sensor type Limit switche
Sensor name XCKJ
Body type Fixed
Head material Zamak
Body Material Metal
PC UV medium flow BLACK - LEXAN

The information provided in this documentation contains general descriptions and/or technical characteristics of the performa nce of the products contained herein.
Rod lever material

This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of th ese products for specific user applications.
143R + Steel
Fixing mode By the body

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Number of poles 2
Contacts operation Snap action
Belt speed / rod lever Max 4m/s

Complementary characteristics
Conforming to IEC 60947-5-1 Appendix C
Utilisation Categories AC-15 and DC-13
Electrical durability Maximum operating rate : 3600 operating cycles / hour
load factor : 0,5

Cable entry ISO M20 x 1,5


AC-15 A300 ( Ue = 240 V , Ie = 3A ) Ithe = 10 A conforming to IEC 60947-5-1
Rated operational characteristics appendix A
DC-13 Q300 ( Ue = 250 V, Ie = 0,27 A ) conforming EN 60947-5-1

resistance across terminals < 25mohms conforming to IEC 60255-7 category 3


Ui = 500V degree of pollution 3 conforming to EN 60947-1
[Ui] rated insulation voltage
Ui = 300V conforming to UL508, CSA C22-2 N° 14

[Uimp] rated impulse withstand voltage U imp = 6 KV conforming to IEC60947-1, IEC 60664
Short circuit protection 10 A cartridge fuse type gG (gl)

Environment characteristics
IP degree of protection IP66 conforming to IEC 60529
IK degree of protection IK07 conforming to EN 50102
Ambient air temperature for operation -40°C to 70°C
Ambient air temperature for storage -40°C to 70°C
Protective treatment TC
Product certifications CE, UL, CSA
IEC 60947-5-1, EN 60947-5-1,UL508, CSA C22-2 n°14
Standards IEC 60204-1, EN 60204-1

1/4
Product data sheet XCKJ105217H29
Dimensions Drawings

Ø25

200

2/4
Product data sheet XCKJ105217H29
Contact diagram

3/4
Product data sheet XCKJ105217H29
Connections and Scheme

4/4