Totally Integrated

Automation Portal

HMI_1 [TP1200 Comfort]


HMI_1
General
Name HMI_1
Totally Integrated
Automation Portal

HMI_1 [TP1200 Comfort]


Runtime settings
General
Start screen TANQUES Load name informa‐ Enabled Default template Template_1
tion
Default style of the Enabled Style of the HMI de‐ WinCC Dark V 1.0.1 Adapt font size to Enabled
project vice style
Screen resolution 1280, 800 Color depth 32 bit Lock task switching Disabled
Project ID 0 Logging language Startup language

Services
Sm@rtAccess or serv‐ Enabled Operate as OPC serv‐ Enabled Sm@rtAccess: SIMAT‐ Enabled
ice: start Sm@rtServ‐ er IC HMI HTTP server
er
Sm@rtAccess: Web Enabled Sm@rtService: HTML Enabled Name of SMTP server
service (SOAP) pages
Port 25 Name of the SMTP SMTP authentication
sender
SMTP login Secure connection for Disabled
SMTP

Screens
Bit selection for ap‐ Off Bit selection for text Off Display limit values as Enabled
pearance analysis and graphic lists a tooltip
Show script com‐ Disabled Scrolling mode Scroll bar
ments

Keyboard
Use screen keyboard Enabled Release button on exit Disabled

Good Manufacturing Practice


Configuration conforms to GMP Disabled

Alarms
Controller alarms
Buffer overflow 10 % Acknowledgment QGR Reporting Enabled
group text
Use alarm class color Disabled Use help texts for sys‐ Enabled System event dura‐ 2 Seconds
tem diagnostics tion
S7 diagnostic alarms Disabled S7 diagnostic alarms Disabled SIMOTION diagnostic Disabled
with numbers only with numbers and alarms
texts
PersistentAlarmBuffer Enabled Connection HMI_Connection_1 Display classes 0-16

User administration
Change initial pass‐ Disabled Change logoff time Enabled Enable limit for logon Enabled
word attempts
Invalid logon at‐ 3 Logon with password Disabled Group-specific rights Disabled
tempts
Password aging Disabled Validity period 90 Warning period 7
Password generations 3 At least one special Disabled At least one number Disabled
character
Minimum password 3 SIMATIC Logon Disabled Apply user adminis‐ WinDomain
length tration from
Server name Port number 16389 Windows domain
Encrypted SIMATIC Enabled
Logon

Language & font


Preset runtime language English (United States)

English (United States)

Runtime language Enabled Fixed font 1 Tahoma Fixed font 2 Courier New
Default font Tahoma, 13 Pixel Configured font 1 Configured font 2

OPC settings
OPC UA server port 4870 OPC UA server URL opc.tcp://[HostName]:4870 No OPC UA server se‐ Enabled
number curity
No OPC UA server se‐ Enabled OPC UA server with Enabled OPC UA server with Disabled
curity 128-bit RSA crypto‐ 128-bit RSA crypto‐
graphic system graphic system with‐
out signature
OPC UA server with Disabled OPC UA server with Enabled
128-bit RSA crypto‐ 128-bit cryptographic
graphic system for system for signatures
signatures and encryption
Totally Integrated
Automation Portal

Tag settings
Replace the separa‐ Enabled Compatibility mode: Disabled Replace the '.' char‐ Enabled
tors on each sub-level Set '_' between the acter if the name of
of the path of the PLC PLC tags and the first- the HMI tag is cre‐
tag: level element. ated from the PLC tag
name
Use '_' as the replace‐ Enabled Use ';' as the replace‐ Disabled Replace the charac‐ Enabled
ment character ment character ters '[' and ']' if the
name of the HMI tag
is created from the
PLC tag name
Use '{' and '}' as re‐ Enabled Use '(' and ')' as re‐ Disabled
placement characters placement characters

Settings for the prefix 'PLC' in the HMI tag name

Connection HMI_Connection_1 PLC name as prefix in the HMI Disabled


tag name