Professional Documents
Culture Documents
A330 TSM Pitot Probe Fault
A330 TSM Pitot Probe Fault
-PHC-3 (6DA3)
2. Job Set-up Information
A. Referenced Information
REFERENCE DESIGNATION
Ref. AMM 30-31-00-710-801 Operational Test of the Probe Ice Protection
Ref. AMM 30-31-34-000-801 Removal of the Probe Heat Computer (PHC)
Ref. AMM 30-31-34-400-801 Installation of the Probe Heat Computer (PHC)
3. Fault Confirmation
SUBTASK 30-31-00-860-080-A
A. Job Set-Up
Get access to the avionics compartment.
SUBTASK 30-31-00-710-080-A
B. Test
Do the operational test of the probe ice protection 3 Ref. AMM 30-31-00-710-801.
4. Fault Isolation
SUBTASK 30-31-00-810-069-A
A. If the test gives the maintenance message:
PHC3(6DA3)
Do the test given in Para. 3 to confirm the fault.
NOTE: If the test gives the maintenance message AOA SENSOR 3 (3FP3)/PHC3 (6DA3) and no
STBY AOA HEAT warning has been displayed, do not take into account this maintenance
message.
(1) Replace the PHC-3 (6DA3), Ref. AMM 30-31-34-000-801 Ref. AMM 30-31-34-400-801.
5. Close-up
SUBTASK 30-31-00-860-081-A
A. Close Access