Professional Documents
Culture Documents
MBCC Repair Material TDS
MBCC Repair Material TDS
High dispersion SBR Latex ensuring higher mixing efficiency with water reduction for site batched
mortars & waterproofing/bonding slurry/screed
PACKAGING
MasterEmaco SBR 2 is supplied in 1, 5, 20 Litre.
SHELF LIFE
The technical information and application advice given in this BASF Construction Chemicals publication are based
STATEMENT OF on the present state of our best scientific and practical knowledge. As the information herein is of a general nature,
RESPONSIBILITY no assumption can be made as to a product's suitability for a particular use or application and no warranty as to its
(Disclaimer) accuracy, reliability or completeness either expressed or implied is given other than those required by law. The
user is responsible for checking the suitability of products for their intended use.
® = registered trademark of BASF group in many countries
Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF
NOTE Construction Chemicals either orally or in writing may be followed, modified or rejected by the owner, engineer or
contractor since they, and not BASF Construction Chemicals, are responsible for carrying out procedures
appropriate to a specific application.
Page 1 of 2
MasterKure® 181
Stir MasterKure 181thoroughly before using. comply with ASTM C 309 Class B. The product
Apply a continuous, uniform film by low-pressure shall exhibit water loss not more then 0.55 kg/m2 in
spray, short nap roller or brush. 72 hours when tested as per ASTM C156. The
Application not recommended when surface product shall form non-degrading abrasion
temperature exceeds 40oC resistance film which shall also exhibit capability
as primer for subsequent protective coatings or
Subsequent surface finishes
bituminous overlays.
The resin in MasterKure 181 ensures that bond is
maintained with adhesives used for installing tiles, PACKAGING
and other floor coverings. MasterKure 181 will act MasterKure 181 is available in 5 & 20 litre packs.
as a primer for paint systems and will enable most
surface treatments to progress with minimal delay.
STORAGE /SHELF LIFE
Typical surface treatments that will bond to
surfaces with MasterKure 181 are: MasterKure 181 must be stored where
temperatures do not drop below +5°C. Store under
Water based emulsion paints containing PVA,
cover, out of direct sunlight and protect from
PVC and acrylic co-polymers
extremes of temperature.
Tile adhesives based on the above polymers
Bituminous emulsions and solutions. Shelf life is12 months when stored as above.
Thin section polymer modified cementitious Failure to comply with the recommended storage
systems. conditions may result in premature deterioration of
Polyurethane resin system the product or packaging. For specific storage
Polysulphide systems advice consult your local Master Builders Solutions
Epoxy resin compositions which do not rely on representative.
penetration for substrate bond. PRECAUTIONS
For further information regarding compatibility of As with all chemical products, care should be
MasterKure 181, contact your local Master taken during use and storage to avoid contact with
Builders Solutions Representative. eyes, mouth, skin and foodstuffs (which can also
be tainted with vapour until product fully cured or
Cleaning dried). Treat splashes to eyes and skin
immediately. If accidentally ingested, seek
Use CLEANING SOLVENT NO. 2 to clean rollers
immediate medical attention. Keep away from
and spray equipment before MasterKure 181
children and animals. Reseal containers after use.
become dry. Any excess cured material will have
Do not reuse containers for storage of consumable
to be mechanically removed.
item. For further information refer to the material
SUGGESTED SPECIFICATION safety data sheet.
The non-degrading membrane forming curing &
sealing compound shall be MasterKure 181, TDS Ref. no.: Masterkrxx181/02/08/2021
acrylic resin based formulation. The product shall
The technical information and application advice given in this Master Builders Solutions publication are based on the
STATEMENT OF present state of our best scientific and practical knowledge. As the information herein is of a general nature, no
RESPONSIBILITY assumption can be made as to a product's suitability for a particular use or application and no warranty as to its
(Disclaimer) accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user
is responsible for checking the suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by Master Builders
NOTE Solutions either orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since
they, and not Master Builders Solutions, are responsible for carrying out procedures appropriate to a specific
application.
MasterEmacoS488/01/0313
The technical information and application advice given in this BASF Construction Chemicals publication are based
STATEMENT OF on the present state of our best scientific and practical knowledge. As the information herein is of a general
RESPONSIBILITY nature, no assumption can be made as to a product's suitability for a particular use or application and no warranty
as to its accuracy, reliability or completeness either expressed or implied is given other than those required by law.
(Disclaimer) The user is responsible for checking the suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF
NOTE Construction Chemicals either orally or in writing may be followed, modified or rejected by the owner, engineer or
contractor since they, and not BASF Construction Chemicals, are responsible for carrying out procedures
appropriate to a specific application.
Page 1 of 2
MasterEmaco® S 466
the temperature is more than 40 0C. Better use CURING
chilled water for mixing.
MasterEmaco S 466 should be cured after
Mortar application formwork removal by MasterKure 181 or with wet
The minimum temperatures must be maintained hessian cloth.
during application and for at least 24 hours
ESTIMATING DATA
thereafter for optimum curing of the product. The
prepared substrate should be pre-soaked, Each bag of MasterEmaco S 466 when mixed with
preferably for 24 hours, but at least 2 hours before 4L of water yields 13.2L. This is near approximate
applying MasterEmaco S 466 ensure all water is value and user is requested to establish trials at site.
removed from formwork prior to installation and PACKAGING
formwork is resealed. MasterEmaco S 466 should
be pumped or poured into the prepared formwork MasterEmaco S 466 is available in 25kg bags.
until the void is filled. Pumping is recommended for SHELF LIFE
larger pours. Do not vibrate MasterEmaco S 466 MasterEmaco S 466 has a shelf life of 6 months.
as it could lead to segregation. Store out of direct sunlight, clear of the ground on
The formwork should be removed after 1-3 days pallets protected from rainfall.
and a curing compound applied. If subsequent
PRECAUTIONS
coats are to be applied the use of clear polyethene
recommended for the first three days after removal It is highly recommended to use necessary PPE
of formwork. For repairs beyond 80mm to 100mm (Gloves, mask etc.,) during installation of the
in thickness, extend MasterEmaco S 466 with up product. In case of Incidents of direct inhalation,
to 25kg of 5-12mm sized washed, saturated causing dizziness/giddiness, loss of
surface-dry (SSD), graded low absorption, high consciousness, contact with eyes etc, seek
density aggregates. Please consult your local immediate medical advice. The requirements may
Master Builders Solutions representative for advice vary depending on the application areas. Please
ensure to have proper ventilation while working in
confined areas. Contact Master Builders Solutions
Protective coatings
representative in case you need further details or
Subsequent coatings of MasterProtect anti- refer to the material safety datasheet of the product
carbonation barriers or silane impregnations should to know more.
be applied as recommend on the individual
datasheets.
The technical information and application advice given in this Master Builders Solutions publication are based on the
STATEMENT OF present state of our best scientific and practical knowledge. As the information herein is of a general nature, no
RESPONSIBILITY assumption can be made as to a product's suitability for a particular use or application and no warranty as to its
(Disclaimer) accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user is
responsible for checking the suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by Master Builders
NOTE Solutions either orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since
they, and not Master Builders Solutions, are responsible for carrying out procedures appropriate to a specific
application.
Page 1 of 2
MasterInject® 1315
PRECAUTIONS
Please refer the Material Safety Data Sheet for
handling and storage of this product.
MasterInject 1315/04/05/2022
The technical information and application advice given in this Master Builders Solutions publication are based on the
STATEMENT OF present state of our best scientific and practical knowledge. As the information herein is of a general nature, no
RESPONSIBILITY assumption can be made as to a product's suitability for a particular use or application and no warranty as to its
(Disclaimer) accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user
is responsible for checking the suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by Master Builders
NOTE Solutions either orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since
they, and not Master Builders Solutions, are responsible for carrying out procedures appropriate to a specific
application.
31 31 73 00 Tunnel Grouting
MasterRoc® MP 355 1K
One component polyurethane injection foam to stop small to
medium water ingress
Description Features
MasterRoc MP 355 1K Gets activated in moist environment
product is a solvent Good bonding to wet surfaces
free, one component
polyurethane resin which Modification of the foaming action can be achieved using an accelerator
turns into a foam when
it comes in contact with Benefits
humidity or moisture. Rapid reaction and excellent bonding feature make it more effective to stop water
ingress
Applications Adjustable reaction time with the associated accelerator provides application flexibility
To stop small to medium
water ingress in Performance Characteristics
underground structures
Technical Data
Filling of voids
containing water MasterRoc MP 355 1K Resin
A brand of
page 1 of 3
MasterRoc MP 355 1K Technical Data Sheet
www.master-builders-solutions.com/en-us page 2 of 3
MasterRoc MP 355 1K Technical Data Sheet