Download as pdf or txt
Download as pdf or txt
You are on page 1of 76

Product Bulletin

61.1:657
D100087X012
August 2009 657 and 667 Actuators

Fisherr 657 and 667 Diaphragm Actuators


Fisher 657 and 667 spring-opposed diaphragm
actuators (figure 1) position the valve plug in the
valve in response to varying controller or valve
positioner pneumatic output signals applied to the
actuator diaphragm. Zero setting of the actuator is
determined by the compression of the actuator
spring. Span is set by both the actuator spring rate
and the number of springs available. The 657
actuator is direct-acting; the 667 is reverse-acting.
These actuators are designed to provide dependable
on-off or throttling operation of automatic control
valves.

Features
D Application Versatility—Five actuator types in
eleven sizes are available for an extensive variety of
applications. Spring rates, travel stops, and manual
operators are available for nearly any control valve
application. W2174-2/IL
W1916-3/IL

D Excellent Linearity Between Loading 667 ACTUATOR


657 ACTUATOR
Pressure and Travel—A molded diaphragm travels
in a deep diaphragm casing, minimizing area change
throughout the travel. Figure 1. Fisher 657 and 667 Actuators Mounted on
easy-er Valves
D High Degree of Dynamic Stability and
Frequency Response—A shallow casing on the D Cold Service Applications—Enhanced
pressure side means reduced volume on that side, product specifications for all sizes of 657 and 667
thereby minimizing response time. diaphragm actuators allow performance to -50_C
(-58_F). Use of a positioner is recommended to
D High Thrust Capability—The molded ensure responsiveness in applications operating
diaphragm allows maximum thrust for given below -40_C (-40_F).
diaphragm size.
D Positive Connections—A split block stem
D Long Service Life—Rugged thick-walled cast connection provides a solid transfer of motion while
iron and steel construction provides increased allowing easy mounting. The absence of linkages
stability, corrosion protection, and protection from helps to avoid lost motion and inaccurate valve
deformation should over-pressurization occur. positioning.

www.Fisher.com
Product Bulletin
61.1:657
657 and 667 Actuators August 2009

Contents Reverse Action


Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 All 667 actuators are reverse acting. Applying air
Available Configurations . . . . . . . . . . . . . . . . . . . . 2 pressure to the lower diaphragm casing forces the
Direct Action . . . . . . . . . . . . . . . . . . . . . . . . . 2 actuator stem upward against the opposing spring
Reverse Action . . . . . . . . . . . . . . . . . . . . . . 2 force. When this loading pressure is reduced, the
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 spring moves the actuator stem downward. Should
Handwheels . . . . . . . . . . . . . . . . . . . . . . . . . 2 the loading pressure fail, the spring forces the stem
Adjustable Travel Stops . . . . . . . . . . . . . . . 6 to the extreme downward position. These actuators
Other . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 provide fail-closed action for push-down-to-close
Ordering Information . . . . . . . . . . . . . . . . . . . . . . 13 valves and fail-open action for push-down-to-open
Tables valves.
Additional Specifications . . . . . . . . . . . . . . . 4
Volumetric Casing Displacement . . . . . . . 5 667—A reverse-acting actuator used on sliding-stem
Approximate Actuator Weights valves. Available in sizes 30 through 100 and 76.
(without handwheel) . . . . . . . . . . . . . . . . 5 See figures 1, 2, 3, and 8.
Thrust Capabilities . . . . . . . . . . . . . . . . . . . . 6
Handwheel Specifications . . . . . . . . . . . . . 9 667-4—A 667 actuator in sizes 70 and 87, designed
Adjustable Travel Stop Styles . . . . . . . . . 10 with 102 mm (4-inch) travel.
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Accessories
Handwheels
Handwheels for diaphragm actuators are often used
Available Configurations as adjustable travel stops. They also provide a ready
means of positioning the control valve in an
emergency. The specifications in tables 5 and 6
apply to handwheels on both 657 and 667 Series
Direct Action actuators. For repeated or daily manual operation,
the unit should be equipped with a side-mounted
All 657 actuators are direct acting. Applying air handwheel actuator.
pressure to the upper diaphragm casing forces the
actuator stem downward. When this pressure is Top-Mounted Handwheels—Typical 657 and 667
reduced, the opposing spring force moves the actuators with handwheels mounted on the
actuator stem upward. Should the loading pressure diaphragm case are shown in figure 3 (not available
fail, the spring forces the stem to the extreme on a 667 actuator, size 80). On the 657 actuator, the
upward position. This provides fail-open action for handwheel can be set to limit the travel in the
push-down-to-close valves and fail-closed action for upward direction; on the 667 actuator, travel in the
push-down-to-open valves. downward direction can be restricted. A P-2 travel
stop (figure 5) is available for a 667 actuator, sizes
657—A direct-acting actuator used on sliding-stem 45-60 to limit travel in either the upward or
valves. Available in sizes 30 through 100. See downward directions. An actuator with a P-2 travel
figures 1, 2, 3, 6, and 7. stop is limited to a maximum travel of 19 mm (0.75
inch). The handwheel on the size 100 is similar in
function to those on the smaller sizes, but it uses a
657-4—A 657 actuator in sizes 70 and 87, designed gear drive similar to the drive employed on the
with 102 mm (4-inch) travel. integral side-mounted handwheels (see figure 3).

2
Product Bulletin
61.1:657
August 2009 657 and 667 Actuators

DIAPHRAGM CASINGS

DIAPHRAGM

DIAPHRAGM PLATE

ACTUATOR SPRING

ACTUATOR STEM

SPRING SEAT

SPRING ADJUSTOR

STEM CONNECTOR

YOKE

TRAVEL INDICATOR DISK

INDICATOR SCALE
W0364-2/IL W0363-2/IL

667 SIZES 30-87 657 SIZES 30-87

657 SIZE 100

W0366-1/IL

Figure 2. Typical Actuators

3
Product Bulletin
61.1:657
657 and 667 Actuators August 2009

Table 1. Additional Specifications for Fisher 657 and 667 Series Actuators
EFFECTIVE YOKE MAXIMUM
STEM MAXIMUM
ACTUATOR DIAPHRAGM BOSS ALLOWABLE
DIA TRAVEL
SIZE AREA DIAMETER THRUST(1)
cm2 mm N
30 297 54 9.5 19 10,231
34 445 54 9.5 29 10,231
40 445 71 12.7 38 12,010
45 677 71 12.7 51 25,132
46 1006 71 12.7 51 33,584
50 677 90 19.1 51 25,131
60 1006 90 19.1 51 30,246
76
70(2) 1419 90 19.1 39,142
102(3)
76(667) 1006 90 19.1 51 30,246
25.4 63,392
80 1761 127 76
31.8 88,075(4)
76
87(2) 1419 127 25.4 39,142
102(3)
127H(5) 31.8
100 2902 102 200,160
178 50.8
Inch2 Inch Lb
30 46 2-1/8 3/8 0.75 2300
34 69 2-1/8 3/8 1.125 2300
40 69 2-13/16 1/2 1.5 2700
45 105 2-13/16 1/2 2 5650
46 156 2-13/16 1/2 2 7550
50 105 3-9/16 3/4 2 5650
60 156 3-9/16 3/4 2 6800
3
70(2) 220 3-9/16 3/4 8800
4(3)
76(667) 156 3-9/16 3/4 2 6800
1 14,150
80 273 5 3
1-1/4 19,800(4)
3
87(2) 220 5 1 8800
4(3)
5H(5) 1-1/4
100 450 4 45,000
7 2
1. These values are based on material limitations such as yoke, stem connection, diaphragm plate, and travel stop strengths.
2. Values also apply to 657-4 and 667-4 actuators.
3. For 657-4 and 667-4 actuator constructions.
4. Steel construction.
5. H=Heavy actuator-to-valve bolting.

4
Product Bulletin
61.1:657
August 2009 657 and 667 Actuators
Table 2. Volumetric Casing Displacement for Fisher 657 and 667 Series Actuators
ACTUATOR
CLEARANCE TRAVEL, mm
SIZE
VOLUME(1)
11 16 19 29 38 51 76 102
cm3 Casing Volume(2), cm3
30 540 918 1080 1180 --- --- --- --- ---
34 and 40 934 1470 1700 1850 2330 2790 --- --- ---
45 and 50 1560 --- 2790 3000 3720 4420 5410 --- ---
46, 60, and 76 2180 --- 3880 4210 5280 6340 7740 --- ---
70 and 87 3490 5240 5950 6420 7830 9240 11,110 14,880 18,570
80 4820 --- --- --- 10,490 12,450 14,860 19,340 ---
657 10,880 --- --- 16,400 19,170 21,940 25,630 33,000 40,380
100
667 12,780 --- --- 18,320 21,070 23,840 27,530 34,900 42,280
TRAVEL, INCH
Inch3 0.4375 0.625 0.75 1.125 1.5 2 3 4
Casing Volume(2), Inch3
30 33 56 66 72 --- --- --- --- ---
34 and 40 57 90 104 113 142 170 --- --- ---
45 and 50 95 --- 170 183 227 270 330 --- ---
46, 60, and 76 133 --- 237 257 322 387 472 --- ---
70 and 87 213 320 363 392 478 564 678 980 1133
80 294 --- --- --- 640 760 907 1180 ---
657 664 --- --- 1002 1170 1339 1564 2014 2464
100
667 780 --- --- 1118 1286 1455 1680 2130 2580
1. Clearance volume indicates casing volume at zero travel.
2. Includes clearance volume.

Table 3. Approximate Actuator Weights (without


handwheel)
ACTUATOR
ACTUATOR
657 667 657 667
SIZE
Kg Lb
30 16 15 36 34
34 22 22 48 48
40 23 23 51 50
45 37 41 82 90
46 49 55 107 121
50 42 43 92 94
60 53 55 116 122
70 107 115 235 254
76 --- 86 --- 190
80 234 284 515 626
87 116 118 255 260
100 346 544 762 1200

5
Product Bulletin
61.1:657
657 and 667 Actuators August 2009

Table 4. Thrust Capabilities(1) by Input Signal Range Clockwise rotation of the handwheel on the 657
PRESSURE RANGE THRUST actuator moves the actuator stem downward,
TRAVEL ACTUATOR TO ACTUATOR CAPABILITIES compressing the spring. Spring action returns the
SIZE DIAPHRAGM(2) 657 667 stem as the handwheel is turned counterclockwise.
mm Bar N With the 667 actuator, counterclockwise rotation
0.2-1 2250 1840 moves the stem upward, and spring action returns
30
0.4-2 3890 3270 the stem on clockwise rotation.
19
0.2-1 3380 3380
34
0.4-2 5830 5530
0.2-1 3380 2760
40
0.4-2 5530 3680
Side-Mounted Handwheels—Figure 4 shows the
0.2-1 4670 4670
side-mounted handwheels (designated by the letters
29 45
0.4-2 8410 8870
MO) applicable to sizes 34 through 87, 657 and 667
0.2-1 6940 6250 actuators. Size 30 actuators do not have a
46 side-mounted handwheel available.
0.4-2 13,190 11,800
0.2-1 5140 3740
50
0.4-2 8410 7010
38
0.2-1 6940 4860
60 All side-mounted handwheels can be used to stroke
0.4-2 13,190 8330
the valve in either direction at any point in the
0.2-1 7830 7830
70 actuator stem travel. Unlike the top-mounted
0.4-2 18,590 13,700
handwheel, the side-mounted handwheel can be
0.2-1 10,110 11,250
51 80 positioned to limit travel in either direction, but not
0.4-2 18,950 19,680
0.2-1 6850 7830
both at the same time. With the handwheel in the
87
0.4-2 18,590 13,700
neutral position, automatic operation is possible
0.2-1 16,010 8010
throughout full valve travel. In any other position,
76
0.4-2 32,030 36,030 valve travel will be restricted. The handwheel is
100
0.2-1 12,010 --- furnished with a spring-loaded ball detent which
102 prevents vibration from changing the setting.
0.4-2 22,019 28,024
Inch Psig Lb
3-15 506 414
30
6-30 874 736
0.75
3-15 759 759
34
6-30 1311 1242
3-15 759 621 Adjustable Travel Stops
40
6-30 1242 828
3-15 1050 1050 Top-mounted adjustable travel stops are available
1.125 45
6-30 1890 1995 for 657 and 667 Series actuators. They are used to
3-15 1560 1404
46 limit travel in the up, down, or up and down
6-30 2964 2652
directions. Figure 5 illustrates the different
3-15 1155 840
50 constructions. Table 7 locates the different style
6-30 1890 1575
1.5 constructions with actuator type and use.
3-15 1560 1092
60
6-30 2964 1872
3-15 1760 1760
70
6-30 4180 3080
3-15 2272 2528
2 80
6-30 4260 4424
3-15 1540 1760 Other
87
6-30 4180 3080
3-15 3600 1800 Accessories such as transducers, positioners,
3
100
6-30 7200 8100 position transmitters, air relays, volume boosters,
4
3-15 2700 --- switching valves, lockup valves, limit switches, and
6-30 4950 6300 solenoid valves are also available for actuator
1. For Size 76 667 actuators, contact your Emerson Process Management sales
office.
mounting. They are described in separate
2. Consult Fisher 657 and 667 instruction manuals (D100306X012,
D100307X012, D100310X012, and D100311X012) for additional information on
publications. Contact your Emerson Process
maximum pressure limitations. Management sales office for details.

6
Product Bulletin
61.1:657
August 2009 657 and 667 Actuators

W0368-2/IL W0369-2/IL

657 ACTUATOR 667 ACTUATOR


(EXCEPT SIZE 100) (EXCEPT SIZES 80 AND 100)

W0370-1/IL

TOP VIEW
W0370-1/IL

657 ACTUATOR SIZE 100


(GEAR DRIVEN)

Figure 3. Typical Top-Mounted Handwheels

7
Product Bulletin
61.1:657
657 and 667 Actuators August 2009

SECTION A-A

W0371-1/IL W0372-1/IL

SIZES 34 THROUGH 60 SIZES 70, 76, 80, AND 87

Figure 4. Typical Side-Mounted Handwheels for Fisher 657 and 667 Series Actuators

STYLE 1 STYLE 2 STYLE 10 STYLE 11


657 AND 657-4 657 AND 657-4 667 DOWN STOP 667 UP
UP STOP DOWN STOP AND DOWN STOP

40A38A1211-E
40A8764-E

STYLE 12 STYLE 13 STYLE 14 STYLE P2


667 UP STOP 667 UP STOP 667 UP STOP 667 UP AND
DOWN STOP

Figure 5. Adjustable Travel Stops

8
Product Bulletin
61.1:657
August 2009 657 and 667 Actuators

Table 5. Fisher 657 Handwheel Specifications


TOP-MOUNTED HANDWHEEL SIDE-MOUNTED HANDWHEEL
Maximum Maximum
657 Handwheel Handwheel Handwheel Handwheel
ACTUATOR Turns Per Rim Force(1) Turns Per Rim Force(1)
Diameter Output Diameter Output
SIZE mm Travel Force(3) mm Travel Force(3)
mm N N mm N N
30 171 0.3 190 6670 --- --- --- ---
34 and 40 222 0.3 210 10,010 304 0.2 230 10,010
45 and 50 222 0.3 420 15,080 355 0.3 360 15,080
46 and 60 222 0.3 490 22,690 355 0.3 540 22,690
70 and 87 355 0.3 590 29,360 432 0.8 160 29,360
80 355 0.3 770 37,770 432 0.4 240 37,770
100(2) 406 6 270 160,000 --- --- --- ---
Turns Per Turns Per
Inch Lb Lb Inch Lb Lb
Inch Travel Inch Travel
30 6.75 8 42 1500 --- --- --- ---
34 and 40 8.75 8 48 2250 12 5.14 52 2250
45 and 50 8.75 8 95 3390 14 6.65 81 3390
46 and 60 8.75 8 110 5100 14 6.65 122 5100
70 and 87 14 8 132 6600 17 20 36 6600
80 14 8 173 8490 17 10 53 8490
100(2) 16 144 60 36,000 --- --- --- ---
1. Tangential handwheel force required to produce the handwheel output force shown. (Proportional to handwheel output force).
2. Top-mounted with gear drive.
3. Maximum force available to compress the actuator spring and close the valve.

9
Product Bulletin
61.1:657
657 and 667 Actuators August 2009

Table 6. Fisher 667 Handwheel Specifications


TOP-MOUNTED HANDWHEEL SIDE-MOUNTED HANDWHEEL
Maximum Maximum
667 Handwheel Turns Rim Handwheel Handwheel Handwheel
ACTUATOR 667 Rim Force(1)
Diameter Per Force(1) Output Diameter Turns Per Output
SIZE ACTUATOR
mm Force(3) mm Travel Force(3)
SIZE
Travel
mm N N mm N N
30 171 0.3 200 6670 30 --- --- --- ---
34 and 40 222 0.3 230 10,010 34 and 40 304 0.2 230 10,010
222 0.2 460 17,790
45 and 50 45 and 50 355 0.3 360 15,080
355 0.2 430 26,690
46, 60, and 222 0.2 460 17,790
46 and 60 355 0.3 540 22,690
76 355 0.2 430 26,690
355 0.2 520 26,690 70, 76, and
70 and 87 432 0.8 160 29,360
762 mm Bar 0.2 410 44,480 87
100(2) 406 6 270 160,000 80 432 0.4 240 37,770
Turns
667 667
Per Turns Per
ACTUATOR Inch Lb Lb ACTUATOR Inch Lb Lb
Inch Inch Travel
SIZE SIZE
Travel
30 6.75 8 45 1500 30 --- --- --- ---
34 and 40 8.75 8 51 2250 34 and 40 12 5.14 52 2250
8.75 6 103 4000
45 and 50 45 and 50 14 6.65 81 3390
14 6 97 6000
46, 60, and 8.75 6 103 4000
46 and 60 14 6.65 122 5100
76 14 6 97 6000
14 6 118 6000 70, 76, and
70 and 87 17 20 36 6600
30 Inch Bar 6 92 10000 87
100(2) 16 144 60 36,000 80 17 10 53 8490
1. Tangential handwheel force required to produce the handwheel output force shown. (Proportional to handwheel output force).
2. Top-mounted with gear drive.
3. Maximum force available to compress actuator spring.

Table 7. Adjustable Travel Stop Styles (1)


60 and
Actuator Size 30 34 40 45 46 50 70 87 80 100
667 Size 76
657 Up Stop 1 1 1 1 1 1 1 1 1 NOTE 2 NOTE 2
657 Down Stop 2 2 2 2 2 2 2 2 2 --- ---
12, 13(3), 12, 13(3), 12, 13(3), 12, 13(3), 12, 13(3), 12, 13(3), 12, 13(3),
667 Up Stop 12 12 13(3) ---
14 14 14 14 14 14 14
667 Down Stop 10 10 10 10 10 10 10 10 10 --- NOTE 2
667 Up and
--- 11 11 11(4), P2(5) 11(4), P2(5) 11(4), P2(5) 11(4), P2(5) --- --- --- ---
Down Stop
1. See figure 5.
2. Top-mounted handwheel, see figure 3.
3. Adjustable handwheel up stop.
4. 38 mm (1.5 inch) maximum travel.
5. Adjustable handwheel up and down stop, 19 mm (0.75 inch) maximum travel.

10
Product Bulletin
61.1:657
August 2009 657 and 667 Actuators

W4917-1/IL
W4273-1/IL

Figure 6. Fisher 646 Electro-Pneumatic Transducer on Figure 8. Fisher 4200 Position Transmitter on
657 Actuator 667 Actuator

W4930/IL

Figure 7. Fisher 3582i Valve Positioner on


657 Actuator

11
Product Bulletin
61.1:657
657 and 667 Actuators August 2009

Table 8. Dimensions
DIMENSION
ACTUATOR SIZE
REFERENCE
30 34 40 45 46 47 50 60 70 76 80 87 100
mm
657, -4 0 25 25 38 38 38 38 38 38 --- --- 38 ---
B
667, -4 38 38 38 38 38 38 38 38 38 38 --- 38 ---
C 289 333 333 406 473 536 406 473 536 473 635 536 729
D 54 54 71 71 71 71 90 90 90 90 127 127 127(2)
657 440 498 548 659 656 --- 722 722 840 --- 1075 938 NOTE 3
657-4 --- --- --- --- --- --- --- --- 994 --- --- 1089 ---
657MO(1) 440 498 548 659 656 --- 722 722 976 --- 1183 1057 NOTE 4
E
667 478 573 594 768 748 --- 784 784 933 881 1257 1003 1857
667-4 --- --- --- --- --- --- --- --- 1070 --- --- 1143 ---
667MO 478 573 594 768 748 --- 784 784 1164 1112 1392 1245 2346
657 121 164 164 202 202 --- 202 202 313 --- 227 313 ---
Hc
667 119 121 137 159 159 --- 159 159 286 159 --- 286 ---
Hs --- 284 286 375 375 --- 378 378 292 222 303 292 401
Jc 171 222 222 222 222 356 222 222 356 356 356 356 ---
Js --- 305 305 356 356 --- 356 356 432 432 432 432 406
657, -4 213 222 272 291 291 395 354 354 406 --- 435 780 451
K
667, -4 194 224 244 310 310 --- 325 325 375 375 432 419 451
657, -4 --- 226 248 306 306 --- 370 370 446 --- 503 527 NOTE 5
M
667, -4 --- 214 248 362 362 --- 378 378 446 446 503 527 2105
657 --- --- --- --- --- --- --- --- --- --- 254 --- ---
657MO --- --- --- --- --- --- --- --- 219 --- 384 219 ---
657-4MO --- --- --- --- --- --- --- --- 219 --- --- 219 ---
N
667 --- --- --- --- --- --- --- --- --- --- 254 --- ---
667MO --- --- --- --- --- --- --- --- 219 219 384 219 ---
667-4MO --- --- --- --- --- --- --- --- 219 --- --- 219 ---
Inches
657, -4 0.00 1.00 1.00 1.50 1.50 1.50 1.50 1.50 1.50 --- --- 1.50 ---
B
667, -4 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 --- 1.50 ---
C 11.38 13.12 13.12 16.00 18.62 21.12 16.00 18.62 21.12 18.62 25.00 21.12 28.69
D 2.125 2.125 2.8125 2.8125 2.8125 2.8125 3.5625 3.5625 3.5625 3.5625 5 5 5(2)
657 17.31 19.62 21.56 25.94 25.81 --- 28.44 28.44 33.06 --- 42.31 36.94 NOTE 3
657-4 --- --- --- --- --- --- --- --- 39.12 --- --- 42.88 ---
657MO 17.31 19.62 21.56 25.94 25.81 --- 28.44 28.44 38.44 --- 46.56 41.62 NOTE 4
E
667 18.81 22.56 23.38 30.25 29.44 --- 30.88 30.88 36.75 34.70 49.50 39.50 73.12
667-4 --- --- --- --- --- --- --- --- 42.12 --- --- 45.00 ---
667MO 18.81 22.56 23.38 30.25 29.44 --- 30.88 30.88 45.81 43.76 54.81 49.00 92.38
657 4.75 6.44 6.44 7.94 7.94 --- 7.94 7.94 12.31 --- 8.94 12.31 ---
Hc
667 4.69 4.75 5.38 6.25 6.25 --- 6.25 6.25 11.25 6.25 --- 11.25 ---
Hs --- 11.19 11.25 14.75 14.75 --- 14.88 14.88 11.50 11.50 11.94 11.50 15.78
Jc 6.75 8.75 8.75 8.75 8.75 14.00 8.75 8.75 14.00 8.75 14.00 14.00 ---
Js --- 12.00 12.00 14.00 14.00 --- 14.00 14.00 17.00 17.00 17.00 17.00 16.00
657, -4 8.38 8.75 10.69 11.44 11.44 15.56 13.94 13.94 16.00 --- 17.12 18.88 17.75
K
667, -4 7.62 8.83 9.62 12.19 12.19 --- 12.81 12.81 14.75 14.75 17.00 16.50 17.75
657, -4 --- 8.88 9.75 12.06 12.06 --- 14.56 14.56 17.56 --- 19.81 20.75 NOTE 5
M
667, -4 --- 8.44 9.75 14.25 14.25 --- 14.88 14.88 17.56 17.56 19.81 20.75 82.88
657 --- --- --- --- --- --- --- --- --- --- 10.00 --- ---
657MO --- --- --- --- --- --- --- --- 8.62 --- 15.12 8.62 ---
657-4MO --- --- --- --- --- --- --- --- 8.62 --- --- 8.62 ---
N
667 --- --- --- --- --- --- --- --- --- --- 10.00 --- ---
667MO --- --- --- --- --- --- --- --- 8.62 8.62 15.12 8.62 ---
667-4MO --- --- --- --- --- --- --- --- 8.62 --- --- 8.62 ---
1. MO = Manual operator.
2. Also available with 7 inch boss.
3. With group 1 springs, E=1959 mm (77.12 inch). With group 2 springs, E=1497 mm (58.94 inch).
4. With group 1 springs, E=2345 mm (92.31 inch). With group 2 springs, E=1883 mm (74.12 inch).
5. With group 1 springs, M=2103 mm (82.81 inch). With group 2 springs, M=1654 mm (65.12 inch).

12
Product Bulletin
61.1:657
August 2009 657 and 667 Actuators

AU6713-D/DOC AU6713-D/DOC
A0171-2/DOC
40A8196/DOC

657, 667, 657, 667, ALL TYPES


657-4, AND 667-4 657-4, AND 667-4 SIZES 70, 80, 87, AND 657 AND 667
SIZES 30 THROUGH 87 SIZES 30 THROUGH 87 667 SIZE 76 SIZE 100

Figure 9. Dimensions (also see table 8)

Ordering Information 8. Seismic requirements, if critical


When ordering, specify:
9. Ambient temperature range
Application
Actuator and Positioner
1. On-off or throttling service
Be sure to specify: actuator type number; whether a
2. Input signal range positioner is required; whether a top-mounted
handwheel is required; and whether an adjustable
3. Maximum supply pressure up or down travel stop is required. Refer to the
Specifications section. Review the information under
4. Valve body type and size with which the actuator each specification and in the referenced tables and
will be used figures. Specify the desired choice wherever there is
a selection to be made.
5. Valve plug travel
Valve Body and Accessories
6. Actuator thrust required with actuator stem both
fully retracted and fully extended Refer to the separate valve body bulletin and
bulletins covering accessories for ordering
7. Stroking time requirements, if critical information.

13
Product Bulletin
61.1:657
657 and 667 Actuators August 2009

Specifications
Standard Operating Pressure Range(1) Signal Connections
657 and 667: J0.2 to 1.0 bar (3 to 15 psig) or Sizes 30 - 60 and 667 Size 76: 1/4 NPT internal
J0.4 to 2.0 bar (6 to 30 psig) Sizes 70 and 87: 1/2 NPT internal
657-4 and 667-4: 0.2 to 1.9 bar (3 to 27 psig) Size 80
667 Size 76: J0.4 to 2.0 bar (6 to 30 psig) or J0 657: 3/4 NPT internal with 1/4 NPT internal
to 3.1 bar (0 to 45 psig) bushing
667: 1/2 NPT internal with 1/4 NPT internal
bushing
Maximum Travel Size 100: 1 NPT internal with 1/4 NPT internal
bushing
See table 1
Effective Diaphragm Area
Output Indication See table 1
Stainless steel disk or pointer and graduated
scale Construction Materials (refer to figure 2)
Diaphragm Casing
Sizes 30 - 87: Steel
Stroking Speed Size 80: JCast iron or Jsteel
Dependent on actuator size, travel, spring rate, Size 100: JCast aluminum
initial spring compression, and supply pressure. If Diaphragm
stroking speed is critical, consult your Emerson Sizes 30 - 87: JNitrile on nylon, JSilicone on
Process Management sales office polyester
Size 100: Nitrile on polyester
Diaphragm Plate
Maximum Allowable Thrust(2) 657 Sizes 30- 60, 100: JCast aluminum
657 Sizes 70 - 87: JCast iron or Jsteel
See table 1
667 Sizes 30 - 60, 100: JCast aluminum or
Jsteel
Operating Temperature Range(1) 667 Sizes 70 - 87: JCast iron or Jsteel
Actuator Spring: Steel
Standard Construction (Nitrile Elastomers): Spring Adjustor: Steel
-40 to 82_C (-40 to 180_F) Spring Seat: JSteel or Jcast iron
Optional Construction (Silicone Diaphragm): Actuator Stem: Steel
-40 to 149C (-40 to 300F) Travel Indicator: Stainless steel
Maximum Valve Packing Box Temperature: O-Rings: Nitrile
427_C (800_F) with cast iron yoke Seal Bushing: Brass
Stem Connector: Zinc-plated steel
Volumetric Displacement Yoke
Sizes 30 - 80: J Cast iron or J steel
See table 2 Size 100: Steel
- continued -

14
Product Bulletin
61.1:657
August 2009 657 and 667 Actuators

Specifications (continued)
Construction Materials for Cold Service Approximate Weight
[to -50_C (-58_F)] 657 and 667--all sizes
Yoke: Steel (Grade LCC) See table 3
Diaphragm: Silicone
O-Rings:(3) Ethylene Propylene
Bolting: Stainless Steel B8M Cl 2 Options
Stem Connector: Stainless Steel
Lubricant: Silicone JOversize signal connections, JPlastic yoke
covers, JWatertight yoke (sealed construction
Stem and Yoke Boss Diameters for certain applications where valve stem and
See table 1 packing must be protected)
1. The pressure and temperature limits in this bulletin and in any applicable standard or code limitation should not be exceeded.
2. Do not exceed the thrust limits in this bulletin.
3. Includes diaphragm casing seals, casing-mounted handjack on 657, seal bushing on 667.

Note
Neither Emerson, Emerson Process
Management, nor any of their affiliated
entities assumes responsibility for the
selection, use, or maintenance of any
product. Responsibility for the
selection, use, and maintenance of any
product remains with the purchaser
and end-user.

15
Product Bulletin
61.1:657
657 and 667 Actuators August 2009

Fisher and easy-e are marks owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co.
Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are
the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they
are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the
designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their affiliated
entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of
any product remains solely with the purchaser and end-user.

Emerson Process Management


Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com

EFisher
16 Controls International LLC 1990, 2009; All Rights Reserved
Bulletin 71.1:67C
March 2004

67C Series Instrument Supply Regulators


✰ Designed for Digital Instrumentation

✰ Optional Smart Bleed™ Construction


A 67CF Series filter

✰ Optional Stainless Steel Construction regulator shown with


optional pressure gauge

✰ Compact and Light Weight

✰ No Air Loss

✰ Easy Maintenance

✰ Optional Integral Filter


W7412

✰ Optional Internal Relief Valve

✰ Rugged Construction
A 67C Series instrument
supply regulator

W8438

A 67CF Series regulator used


as a supply regulator for
digital instrumentation

A 67CF Series regulator used as


W7426
a pilot supply regulator for the
Type 299H pressure regulator

W7423_1
D102656X012

www.FISHERregulators.com
Bulletin 71.1:67C

Introduction
The 67C Series regulators are typically used to provide constantly controlled, reduced pressures to pneumatic and
electropneumatic controllers and other instruments. These direct-operated regulators are suitable for most air or
gas applications. Other applications include providing reduced pressures to air chucks, air jets, and spray guns.

Features • Internal Relief—The Types 67CR, 67CSR, 67CFR,


• Compact—The 67C Series regulators are engi- and 67CFSR have an internal relief valve with a soft
neered for outstanding performance in a compact, seat for reliable shutoff with no discernible leakage.
light-weight package. These regulators are recommended for conserving
plant air.
• Panel Mounting—Panel mount construction
includes spring case with 1/4-inch NPT vent, • Smart Bleed™—Opens to exhaust downstream
handwheel adjusting screw, and mounting nut. pressure when inlet pressure drops below outlet
pressure. Recommended for deadend service.
• Instrument Supply Regulator—The Types 67CF,
67CFR, 67CFS, and 67CFSR provide a clean air • Integral Filter—The Types 67CF, 67CFR, 67CFS,
and 67CFSR have an integral filter ensuring clean
supply to a variety of pneumatic and electro-pneumatic
downstream air supply.
instrumentation.
• Ease of Maintenance—No special tools are
• Digital Instrument Supply Regulator—Designed
required to perform maintenance, and all maintenance
for the accuracy, repeatability, and hysteresis de-
can be performed with the regulator in the line. Filter
mands of digital instrumentation.
elements are easily replaced. The one-piece valve
• Pilot Supply Regulator—Improves the accuracy plug cartridge allows easy inspection and replacement.
of two-path control regulators by reducing inlet sensi- • Rugged Construction—The 67C Series regulators
tivity caused by fluctuating inlet pressures. are engineered for longer service life with minimal
• Pressure Loading Regulator—Provides accuracy maintenance requirements.
and improved performance in dirty steam service by • Second Outlet—Body side outlet for pressure
eliminating the need for a pilot regulator (see figure 3). gauge or other uses.
• Sour Gas Service Capability—NACE MR0175 and • Powder Paint Coating—Types 67C, 67CR, 67CF,
MR0103 compliant construction available. and 67CFR are powder paint coated, offering impact,
• Optional Stainless Steel Construction—The abrasion, and corrosion resistance. Stainless steel
Types 67CS, 67CSR, 67CFS and 67CFSR provide high regulators (Types 67CS, 67CSR, 67CFS and 67CFSR)
resistance to corrosion especially beneficial in offshore are not painted.
applications. • Corrosion Resistant Fasteners—Bolting and
• Full Usable Capacity—Fisher regulators are adjusting screw are double zinc-chromated for en-
laboratory tested. 100 percent of the published hanced corrosion resistance. Optional stainless steel
capacities can be used with confidence. bolting and adjusting screw are also available.

Table 1. Outlet Pressure Ranges and Control Spring Data

OUTLET PRESSURE RANGES, CONTROL SPRING DATA


Type
PSIG (bar) Color Material Part Number Wire Diameter, Inch (mm)
0 to 20 (0 to 1,4) green stripe GE07809T012 0.135 (3,43)
0 to 35 (0 to 2,4) silver T14059T0012 0.156 (3,96)
Music Wire
0 to 60 (0 to 4,1) blue stripe T14058T0012 0.170 (4,32)
67C, 67CR,
0 to 125 (0 to 8,6) red stripe T14060T0012 0.207 (5,26)
67CF, 67CFR
0 to 35 (0 to 2,4) silver stripe T14113T0012 0.156 (3,96)
0 to 60 (0 to 4,1) blue Inconel T14114T0012 0.172 (4,37)
0 to 125 (0 to 8,6) red T14115T0012 0.207 (5,26)
0 to 20 (0 to 1,4) green 10C1729X012 0.135 (3,43)
0 to 35 (0 to 2,4) silver stripe T14113T0012 0.156 (3,96)
67CS, 67CSR,
0 to 60 (0 to 4,1) blue Inconel T14114T0012 0.172 (4,37)
67CFS, 67CFSR
0 to 125 (0 to 8,6) red T14115T0012 0.207 (5,26)
0 to 150 (0 to 10,3) black 10C1730X012 0.250 (6,35)

2
Bulletin 71.1:67C
Specifications

Body Size, Inlet and Outlets Connection Style Smart Bleed™ Check Valve Setpoint
1/4-inch NPT 6 psi (0,4 bar) differential
Construction Materials Pressure Registration
See Table 2 Internal
(1)
Maximum Inlet Pressure (Body Rating) Drain Valve and Spring Case Vent Location
All except 67CS and 67CSR: 250 psig (17,2 bar) Aligned with inlet standard, other positions optional
Type 67CS and 67CSR: 400 psig (27,6 bar)
Regulator Temperature Capabilities
Outlet Pressure Ranges
With Nitrile (NBR)
See Table 1
Standard Bolting: -20 to 180°F (-29 to 82°C)
Maximum Emergency Outlet Pressure(1) Stainless Steel Bolting: -40 to 180°F (-40 to 82°C)
50 psi (3,4 bar) over outlet pressure setting With Fluoroelastomer (FKM):
0 to 300°F (-18 to 149°C)
Capacities
With Silicone (VMQ)(3) Diaphragm and Low
See Table 3 and Capacity Information section Temperature bolting: -60 to 180°F (-51 to 82°C)
Wide-Open Flow Coefficients With Gauges: -20 to 180°F (-29 to 82°C)
Main Valve: Cg: 11.7; Cv: 0.36; C1: 32.2; Type 67CF, 67CFR, 67CFS, and 67CFSR Filter
Internal Relief Valve: Cg: 1.45; Cv: 0.045; C1: 32.8 Capabilities
IEC Sizing Cooefficients Free Area: 12 times pipe area
Main Valve: XT: 0.66; FL: 0.89; FD: 0.50 Micron Rating: Cellulose Element: 40 microns
Glass Fiber Element: 5 microns
Accuracy Stainless Steel Element: 40 microns
Inlet Sensitivity: Less than 0.2 psig (0,014 bar)
Options
change in outlet pressure for every 25 psig
(1,72 bar) change in inlet pressure All Types
Repeatability: 0.1 psig (0,0069 bar)(2) • Handwheel adjusting screw
• Inlet screen
Air Consumption: testing repeatedly shows
• NACE MR0175(4) or NACE MR0103 construction
no discernible leakage
• Panel mount (includes spring case with 1/4-inch
Type 67CR, 67CSR, 67CFR, and 67CFSR Internal vent, handwheel, and panel mounting nut)
Relief Performance • Closing cap (available on spring case with
Low capacity for minor seat leakage only; other 1/4-inch NPT vent)
overpressure protection must be provided if inlet • Fluoroelastomer (FKM) elastomers for high
pressure can exceed the maximum pressure rating temperatures and/or corrosive chemicals
of downstream equipment or exceeds maximum • Silicone (VMQ) elastomers for cold temperatures
outlet pressure rating of the regulator. • Fixed Bleed Restriction
• Triple scale outlet pressure gauge (brass or
Approximate Unit Weight stainless steel)
Types 67C, 67CR, 67CF, and 67CFR: • Stainless steel stem on the valve plug
1 pound (0,5 kg) • Tire valve or pipe plug in second outlet
Types 67CS and 67CSR: Type 67CFR only
2.5 pounds (1,2 kg) • Smart Bleed™ internal check valve
Types 67CFS and 67CFSR: Types 67CF and 67CFR only
4 pounds (1,8 kg) • Stainless steel drain valve

1. The pressure/temperature limits in this bulletin and any applicable standard or code limitation should not be exceeded.
2. Repeatability is the measure of the regulator's ability to return to setpoint consistently when traveling from steady state to transient to steady state.
3. Silicone is not compatible with hydrocarbon gas.
4. Product complies with the material requirements of NACE MR0175. Environmental limits may apply.

3
Bulletin 71.1:67C

TYPE 67CR OR 67CSR TYPE 67CF OR 67CFS

TYPE 67C OR 67CS

INLET PRESSURE W7433

OUTLET PRESSURE
ATMOSPHERIC PRESSURE TYPE 67CFR OR 67CFSR SMART BLEED™ OPTION
TYPE 67CFR ONLY
Figure 2. 67C Series Operational Schematics

Table 2. 67C Series Construction Materials


TYPE
MATERIAL
67C and 67CR 67CF and 67CFR 67CS and 67CSR 67CFS and 67CFSR
Body and
Aluminum (ASTM B85/Alloy 380) CF8M/CF3M Stainless steel
Spring Case
Bottom Plate 316 Stainless steel --- 316 Stainless Steel ---
Pusher Post and Valve
Polyester resin
Cartridge
Upper Spring Seat Zinc-plated Steel 316 Stainless steel
Lower Spring Seat,
Chromate conversion coated aluminum 316 Stainless steel
Diaphragm Plate
Control Spring Plated Steel or Inconel (NACE) Inconel
Brass stem with Nitrile plug,
316 Stainless steel stem with
Valve Plug Aluminum stem with Nitrile or Fluoroelastomer plug, or
Nitrile or Fluoroelastomer plug
Stainless steel stem with Nitrile or Fluoroelastomer plug
Valve Spring Stainless steel or Inconel (NACE) Inconel
Diaphragm
Nitrile, Fluoroelastomer, or Silicone(1)
and O-Rings
Soft Seat and Gaskets Nitrile or Fluoroelastomer
Bolting, Adjusting
Zinc-plated steel or Stainless steel 316 Stainless steel
Screw, Locknut
Handwheel Zinc-plated steel screw with resin handwheel
316
Filter Retainer --- Plated Steel ---
Stainless steel
Cellulose, Glass fiber or
Filter Element --- ---
Glass fiber, or Stainless steel 316 Stainless steel
Brass or 316 Stainless Steel or
Drain Valve --- ---
Stainless steel 18-8 Stainless steel
Aluminum
Dripwell --- --- CF8M/CF3M Stainless steel
(ASTM B85/Alloy 380)
1. Silicone diaphragm only available with internal relief (67CR, 67CSR, 67CFR, 67CFSR).

4
Bulletin 71.1:67C
Principle of Operation (figure 2) leakage only. Other overpressure protection must be
provided if the maximum inlet pressure can exceed the
Downstream pressure is registered internally on the maximum pressure rating of the downstream equipment
lower side of the diaphragm. When the downstream or exceeds maximum outlet pressure rating of the
pressure is at or above the set pressure, the valve plug Type 67CR, 67CSR, 67CFR, or 67CFSR regulator.
is held against the orifice and there is no flow through
the regulator. When demand increases, downstream
pressure drops slightly allowing the spring to extend,
Capacity Information
moving the stem down and the valve plug away from Table 3 shows the air regulating capacities of the
the orifice. This allows flow through the regulator. 67C Series regulators at selected inlet pressures and
outlet pressure settings. Flows are shown in scfh
Internal Relief (Types 67CR, 67CSR, (at 60°F and 14.7 psia) and in m³/h(n) (at 0°C and
1,01325 bar) of air.
67CFR, and 67CFSR)
If for some reason, outside of normal operating Note
conditions, the downstream pressure exceeds the set The 67C Series regulators may be sized
point of the regulator, the force created by the for 100% flow using capacities as shown
downstream pressure will lift the diaphragm until the in table 3. It is not necessary to reduce
diaphragm is lifted off the relief seat. This allows flow published capacities.
through the token relief. The relief valve on the
Type 67CR, 67CSR, 67CFR, or 67CFSR is an elastomer To determine the equivalent capacities for other gases,
plug that prevents leakage of air from the downstream multiply the table capacity by the following appropriate
to atmosphere during normal operation, thereby conversion factor: 1.29 for 0.6 specific gravity natural
conserving plant air. gas, 0.810 for propane, 0.707 for butane, or 1.018 for
nitrogen. For gases of other specific gravities, divide
Smart Bleed™ Airset the table capacities by the square root of the appropri-
ate specific gravity. To find wide-open flow capacities
In some cases, it is desired to exhaust downstream
for relief sizing at any inlet pressure, perform one of
pressure if inlet pressure is lost or drops below the
the following procedures. Then, if necessary, convert
setpoint of the regulator. For example, if the regulator is
using the factors provided above.
installed on equipment that at times has no flow
demand but is expected to backflow on loss of inlet For critical pressure drops (absolute outlet pressure
pressure. The Type 67CFR can be ordered with the equal to or less than one-half of absolute inlet pres-
Smart Bleed™ option which includes an internal check sure), use the following formula:
valve for this application. During operation, if inlet
Q = (P1)(Cg)
pressure is lost, or decreases below the setpoint of the
regulator, the downstream pressure will back flow
For pressure drops lower than critical (absolute
upstream through the regulator and check valve. This
outlet pressure greater than one-half of absolute inlet
option eliminates the need for a fixed bleed downstream
pressure), use the following formula:
of the regulator, thereby conserving plant air.
520 ⎛ 3417 ∆P ⎞
Q= CgP1SIN ⎜⎜ ⎟ DEG
Overpressure Protection GT ⎝ C1 P1 ⎟⎠
The 67C Series regulators have maximum outlet where,
pressure ratings that are lower than their maximum
Q = gas flow rate, scfh
inlet pressure ratings. A pressure relieving or pressure
P1 = absolute inlet pressure, psia (P1 gauge + 14.7)
limiting device is needed if inlet pressure can exceed
the maximum outlet pressure rating. Refer to the Cg = gas sizing coefficient
Capacity Information section and the Wide-Open G = specific gravity of the gas
Coefficients for Relief Valve Sizing in the Specifica- T = absolute temperature of gas at inlet, °Rankine
tions on page 3 to determine the required relief valve C1 = flow coefficient (Cg ÷ Cv)
capacity. ∆P = pressure drop across the regulator, psi
Type 67CR, 67CSR, 67CFR, and 67CFSR regulators Then, if capacity is desired in normal cubic meters per
have a low capacity internal relief valve for minor seat hour (at 0°C and 1,01325 bar), multiply scfh by 0.0268.

5
Bulletin 71.1:67C
Table 3. Capacities
=OUTLET PRESSURE CAPACITIES IN SCFH (m3/h(n)) OF AIR
OUTLET
RANGE, SPRING PART INLET PRESSURE,
PRESSURE, Types 67C, 67CR, 67CS, and 67CSR Types 67CF, 67CFR, 67CFS, and 67CFSR
NUMBER AND COLOR, PSIG (bar)
PSIG (bar)
PSIG (bar) 10% Droop 20% Droop 10% Droop 20% Droop
50 (3,4) 250 (6,70) 430 (11,5) 250 (6,70) 430 (11,5)
75 (5,2) 340 (9,11) 610 (16,3) 300 (8,04) 690 (18,5)
100 (6,9) 430 (11,5) 800 (21,4) 330 (8,84) 1000 (26,8)
15 (1,0)
150 (10,3) 680 (18,2) 1200 (32,2) 400 (10,7) 1600 (42,9)
250 (17,2) 1300 (34,8) 1900 (50,9) 450 (12,1) 1800 (48,2)
400 (27,6)(2) 390 (10,5) 1850 (50,0) -- -- -- --
50 (3,4) 310 (8,31) 460 (12,3) 350 (9,38) 500 (13,4)
0 to 35 (0 to 2,4) 75 (5,2) 420 (11,3) 700 (18,8) 530 (14,2) 820 (22,0)
T14059T0012 (Silver) 100 (6,9) 620 (16,6) 940 (25,2) 750 (20,1) 1100 (29,5)
20 (1,4)
T14113T0012 150 (10,3) 960 (25,7) 1450 (38,9) 1400 (37,5) 1600 (42,9)
(Silver Stripe) 250 (17,2) 1550 (41,5) 2150 (57,6) 2550 (68,3) 2700 (72,3)
400 (27,6)(2) 1200 (32,2) 2750 (73,7) -- -- -- --
50 (3,4) 390 (10,5) 490 (13,1) 390 (10,5) 500 (13,4)
75 (5,2) 590 (15,8) 850 (22,8) 640 (17,1) 820 (22,0)
100 (6,9) 770 (20,6) 1150 (30,8) 840 (22,5) 1100 (29,5)
35 (2,4)
150 (10,3) 1200 (32,2) 1750 (46,9) 1450 (38,9) 1650 (44,2)
250 (17,2) 2200 (58,9) 2700 (72,3) 2450 (65,6) 2700 (72,3)
400 (27,6)(2) 2850 (76,4) 3450 (92,5) -- -- -- --
50 (3,4) 310 (8,31) 440 (11,8) 330 (8,84) 470 (12,6)
75 (5,2) 440 (11,8) 670 (18,0) 500 (13,4) 730 (19,6)
100 (6,9) 560 (15,0) 900 (24,1) 700 (18,8) 1000 (26,8)
35 (2,4)
150 (10,3) 780 (20,9) 1350 (36,2) 1050 (28,1) 1550 (41,5)
0 to 60 (0 to 4,1) 250 (17,2) 1450 (38,9) 2200 (59,0) 2000 (53,6) 2600 (69,7)
T14058T0012 400 (27,6)(2) 770 (20,6) 2500 (67,0) -- -- -- --
(Blue stripe)
T14114T0012 (Blue) 75 (5,2) 520 (13,9) 720 (19,3) 520 (13,9) 720 (19,3)
100 (6,9) 750 (20,1) 1050 (28,1) 770 (20,6) 1000 (26,8)
60 (4,1) 150 (10,3) 1100 (29,5) 1700 (45,6) 1100 (29,5) 1600 (42,9)
250 (17,2) 2050 (54,9) 2850 (76,4) 2450 (65,6) 2750 (73,7)
400 (27,6)(2) 3200 (85,8) 4300 (115) -- -- -- --
100 (6,9) 500 (13,4) 800 (21,4) 530 (14,2) 780 (20,9)
150 (10,3) 750 (20,1) 1200 (32,2) 780 (20,9) 1200 (32,2)
0 to 125 (0 to 8,6) 80 (5,5)
250 (17,2) 1200 (32,2) 2050 (54,9) 1250 (33,5) 2200 (58,9)
T14060T0012 400 (27,6)(2) 910 (24,4) 3700 (99,2) -- -- -- --
(Red stripe)
T14115T0012 (Red) 150 (10,3) 900 (24,1) 1250 (33,5) 900 (24,1) 1150 (30,8)
125 (8,6) 250 (17,2) 1560 (41,8) 2450 (65,6) 1650 (44,2) 2450 (65,6)
400 (27,6)(2) 2200 (59,0) 4350 (117) -- -- -- --
250 (17,2) 550 (14,7) 1200 (32,2) 550 (14,7) 1200 (32,2)
80 (5,5)
400 (27,6)(2) 400 (10,7) 1100 (29,5) -- -- -- --
0 to 150 (0 to 8,6)(1) 250 (17,2) 970 (26,0) 1800 (48,2) 1100 (29,5) 1800 (48,2)
135 (9,3)
10C1730X012 (Black) 400 (27,6)(2) 840 (22,5) 2350 (63,0) -- -- -- --
250 (17,2) 1100 (29,5) 1850 (49,6) 1100 (29,5) 1850 (49,6)
150 (10,3)
400 (27,6)(2) 940 (25,2) 2500 (67,0) -- -- -- --
1. Available for Types 67CS, 67CSR, 67CFS and 67CFSR only
2. Inlet pressures above 250 psig (17,2 bar) with a maximum of 400 psig (27,6 bar) only available on Types 67CS and 67CSR.

670 Series Panel-Mounted Loading connected to one or two gauges and a changeover
valve. A single gauge typically shows loading
Regulators (figure 4) pressure to the control valve. For more information
see bulletin 62.3:670.
The 670 Series panel-mounted loading regulators are
compact, rugged units used primarily for manually
loading pressure-balanced gas regulators and providing
manual control for diaphragm actuator control valves. Ordering Information
Applications include remote control of gas pressure to
burners in refineries, power plants, and various When ordering, complete the Ordering Guide on page
process furnaces. 12. Refer to the Specifications on page 3. Review the
description to the right of each specification and the
Three basic panels are available within the product information in each referenced table or figure. Specify
line, each having one 67C Series pressure regulator your choice whenever a selection is offered.

6
Bulletin 71.1:67C

67C SERIES
FILTER REGULATOR

UPSTREAM PRESSURE
LOADING PRESSURE
W7434
DOWNSTREAM PRESSURE TYPE 92P
STEAM REGULATOR

A 67C SERIES PRESSURE LOADING REGULATOR USED WITH THE TYPE 92P STEAM REGULATOR ELIMINATES THE NEED FOR A
PILOT REGULATOR. THIS PROVIDES HIGH ACCURACY AND IMPROVED PERFORMANCE IN DIRTY STEAM SERVICE.

Figure 3. 67C Series Regulator Used to Pressure Load a 92P Steam Regulator

1-GAUGE PANEL 2-GAUGE PANEL 2-GAUGE PANEL WITH


CHANGEOVER VALVE

Figure 4. 670 Series Typical Panel Layouts

7
Bulletin 71.1:67C
4.56 2.56
(116) (65)

2.92 0.50
(74) (13)
1.46
(37)

A
MAX
OUTLET
OPTIONAL GAUGE
CONNECTIONS
1/4-INCH NPT

INLET CONNECTION
1/4-INCH NPT

STANDARD DIMENSIONS

SIDE OUTLET
STANDARD DIMENSIONS
1/4-INCH NPT
FOR GAUGE OPTION 2.56
(65)
INCHES
(mm)
4.56 1.43
(116) (36)
CLOSING CAP
2.92
(74)

1.46
(37)

0.72-INCH (1,8 mm)


SPRING CASE
2.37 A
PANEL BOSS
(60) PANEL
MAX 0.12 TO 0.25
(3,0 TO 6,5)

A 1/4-INCH NPT VENT


MAX

D OUTLET
CONNECTIONS
C OPTIONAL GAUGE 1/4-INCH NPT

INLET CONNECTION
1/4-INCH NPT

SIDE OUTLET TAPPED


1/4-INCH NPT

DIMENSIONS FOR PANEL MOUNT OPTION WITH DIMENSIONS WITH CLOSING CAP
HAND WHEEL AND 1/4-INCH SPRING CASE VENT AND 1/4-INCH SPRING CASE VENT

DIMENSION WITH
STANDARD DIMENSIONS PANEL MOUNT OPTION WITH HANDWHEEL DIMENSIONS
TYPE CLOSING CAP
A B A A C D
67C , 67C R 3.50 (89) 1.51 (38) 4.60 (117) 4.69 (119) 1.08 (27) 2.33 (59)
67C S , 67C S R 4.13 (105) 1.62 (41) 4.93 (125) 5.00 (127) 1.14 (29) 2.65 (67)

Figure 5. Types 67C, 67CR, 67CS, and 67CSR Dimensions

8
Bulletin 71.1:67C
4.56
(116) 2.56
3.00
(65)
(76)
1.48 0.62
(38) (16)

3.50
(89)

INLET CONNECTION OUTLET


1/4-INCH NPT CONNECTIONS
1/4-INCH NPT
0.69
OPTIONAL GAUGE (18)

MOUNTING HOLES
3.50 FOR 5/16-INCH
(89) DIAMETER BOLTS

SIDE OUTLET
1/4-INCH NPT

2.25
(57)

B2699_A INCHES 2.87


(mm) (73)
B2699_B
DIMENSIONS
FOR GAUGE OPTION STANDARD DIMENSIONS

Figure 6. Types 67CF and 67CFR Dimensions

DRAIN VALVE
GAUGE

VENT POSITION 2 POSITION 4

DRAIN VALVE
VENT POSITION 1 POSITION 1 DRAIN VALVE
VENT POSITION 3 POSITION 3
(STANDARD) (STANDARD)

INLET OUTLET
INLET OUTLET
GAUGE

VENT POSITION 4
DRAIN VALVE
POSITION 2
B2699_D
B2699_C

VENT POSITIONS DRAIN VALVE POSITIONS

Figure 7. 67C Series Vent and Drain Valve Positions

9
Bulletin 71.1:67C
4.56 2.56
(116) (65)
3.00
(76) 1.43
(36) CLOSING CAP

2.37
(60) 1.48
MAX PANEL (38)
0.12 TO 0.25 0.72-INCH (1,8 mm)
(3,0 TO 6,5) SPRING CASE
PANEL BOSS
4.78
4.69
(121)
(119)
MAX
1/4-INCH NPT VENT

2.41
(61)
1.14 INLET CONNECTION OUTLET
(29) 1/4-INCH NPT CONNECTIONS
1/4-INCH NPT

0.69
OPTIONAL GAUGE (18)

MOUNTING HOLES
3.50 FOR 5/16-INCH
(89) DIAMETER BOLTS

SIDE OUTLET TAPPED


1/4-INCH NPT

2.25
(57)
B2700_A
INCHES 2.87
(mm) (73)
B2700_B

DIMENSIONS FOR PANEL MOUNT OPTION


WITH HAND WHEEL AND 1/4-INCH SPRING CASE VENT DIMENSIONS FOR CLOSING CAP OPTION
WITH 1/4-INCH SPRING CASE VENT

Figure 8. Types 67CF and 67CFR Dimensions (continued)

SPACER
(FOR INSTALLING A 67CF SERIES
REGULATOR IN AN EXISTING
0.18
INSTALLATION IF THE MOUNTING
(4,57)
BOLTS ARE TOO LONG)

0.50 OD 0.32
(12.7) ID
(8.12)

B2697_B

SPACER OUTER DIAMETER SPACER WIDTH AND


INNER DIAMETER

B2697_A

Figure 9. Spacer Dimensions and Installation Schematic

10
Bulletin 71.1:67C
4.56 1.43
(116) (36)
3.00 2.56
(76) (65)
1.48 0.62 CLOSING
(38) (16) CAP

VENT 1/4 NPT

4.93
(125)

1/4-INCH NPT INLET


CONNECTION
1/4-INCH NPT
OUTLET
1.14 CONNECTIONS
(29)

0.69
(18)

4.00 MOUNTING HOLES


(102) FOR 5/16-INCH
OPTIONAL DIAMETER BOLTS
GAUGE

1/4-INCH NPT
INLET CONNECTION
2.25
(57)
INCHES 2.87
(mm) (73)

STANDARD DIMENSIONS (INCLUDING CLOSING CAP) STANDARD DIMENSIONS (INCLUDING CLOSING CAP)

2.37
(60)
MAX

5.00
(127)
4.13
MAXIMUM
(105)
MAXIMUM PANEL
0.12-0.25 2.65
(3-6,5) (67)

INCHES
(mm)

DIMENSIONS WITHOUT CLOSING CAP DIMENSIONS FOR PANEL MOUNT OPTION WITH HANDWHEEL

Figure 10. Types 67CFS and 67CFSR Dimensions

11
Bulletin 71.1:67C
Ordering Guide Spring Case Vent Location (Select One)
 Position 1 - Aligned with inlet (standard)***
Type (Select One)  Position 2
 Type 67C (aluminum without internal relief)***  Position 3
 Type 67CR (aluminum with internal relief)***  Position 4
 Type 67CS (stainless steel without internal relief)*** Fixed Bleed for Type 67CR, 67CSR, 67CFR, or 67CFSR (Optional)
 Type 67CSR (stainless steel with internal relief)***  Yes**
 Type 67CF (aluminum with filter and without internal relief)***
 Type 67CFR (aluminum with filter and internal relief)*** Smart Bleed™ Internal Check Valve Airset (Optional - 67CFR only)
 Type 67CFS (stainless steel with filter and without  Yes**
internal relief)*** Second Outlet (Select One)
 Type 67CFSR (stainless steel with filter and internal relief)***  Open (67C, 67CR, 67CF, 67CFR standard)***
 Plugged with pipe plug (67CS, 67CSR, 67CFS, 67CFSR
Quantity (Specify)
standard)***
Spring Case Style (Select One)  Tire Valve***
 Drilled hole vent (67C, 67CR, 67CF, 67CFR standard)***  Pressure Gauge (see below)
 1/4-inch NPT vent (67CS, 67CSR, 67CFS, 67CFSR standard)*** Triple Scale Pressure Gauge (Optional)
 Single hole panel mount***
 Brass Gauge or  Stainless Steel Gauge
Adjusting Screw (Select One)  0 to 30 psig/0 to 0.2 MPa/0 to 2 bar***
 Square head (67C, 67CR, 67CF, 67CFR standard)***  0 to 60 psig/0 to 0.4 MPa/0 to 4 bar***
 Square head with closing cap (67CS, 67CSR, 67CFS,  0 to 160 psig/0 to 1.1 MPa/0 to 11 bar***
67CFSR standard)*** NACE MR0175 Construction (Optional)(1)
 Handwheel***  Yes (not available with gauge)**
Outlet Pressure Range (Select One) 1. Product complies with the material requirements of NACE MR0175.
 0 to 20 psig (0 to 1,4 bar)*** Environmental limits may apply.
 0 to 35 psig (0 to 2,4 bar)*** NACE MR0103 Construction (Optional)
 0 to 60 psig (0 to 4,1 bar)***  Yes (not available with gauge)**
 0 to 125 psig (0 to 8,6 bar)***
 0 to 150 psig (0 to 10,3 bar) (67CS, 67CSR, 67CFS, 67CFSR Replacement Parts Kit (Optional)
only)***  Yes, send one replacement parts kit to match this order.
Diaphragm, O-Rings, and Valve Plug (Select One)
 Nitrile (NBR) (standard)***
 Fluoroelastomer (FKM)**
 Silicone (VMQ) diaphragm, O-rings, and nitrile valve plug*
Filter Material (Select One)
 Cellulose (40 microns)(67CF, 67CFR standard)***
 Glass (5 microns)*** Specification Worksheet
 Stainless steel (40 microns)(67CFS, 67CFSR standard)*** Application (Please designate units):
Drain Valve (Select One) Specific Use
 Brass (67CF, 67CFR standard)*** Line Size
 Stainless steel (67CFS, 67CFSR standard)*** Gas Type and Specific Gravity
Drain Valve Location (Select One) Gas Temperature
 Position 1 - Aligned with inlet (standard)*** Does the Application Require Overpressure Protection?
 Position 2  No  Yes, if so, which is preferred:
 Position 3  Relief Valve  Monitor Regulator  Shutoff Device
 Position 4 Is overpressure protection equipment selection assistance
desired?
Pressure (Please designate units):
Maximum Inlet Pressure (P1max)
Fisher Regulators Quick Order Guide Minimum Inlet Pressure (P1min)
Downstream Pressure Setting(s) (P2)
*** Standard - Readily Available for Shipment Maximum Flow (Qmax)
** Non-Standard - Allow Additional Time for Shipment Performance Required:
Accuracy Requirements?
Special Order, Constructed from Non-Stocked Parts. Need for Extremely Fast Response?
*
Consult Your Fisher Sales Representative for Availability. Other Requirements:
Availability of the product being ordered is determined by the component
with the longest shipping time for the requested construction.

Fisher is a mark owned by Fisher Controls International, Inc., a business of Emerson Process Management. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the
property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express
or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Fisher does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Fisher product remains solely with the purchaser.

For information, contact Fisher:


Marshalltown, Iowa 50158 USA
McKinney, Texas 75070 USA
28320 Gallardon, France
40013 Castel Maggiore (BO), Italy
Sao Paulo 05424 Brazil
Singapore 128461

©Fisher Controls International, Inc., 2001, 2004; All Rights Reserved www.FISHERregulators.com
Product Bulletin
62.1:DVC6000(S1)
D103308X012
February 2009 FIELDVUE Digital Valve Controllers

Fisherr FIELDVUEt DVC6000, DVC6000 SIS,


and DVC6000f Series Digital Valve Controller
Dimensions
This supplemental bulletin includes dimensions for Installation
all Fisher FIELDVUE DVC6000 Series digital valve
controllers, including DVC6000 for HARTt
The DVC6010 / DVC6010 SIS / DVC6010f digital
applications, DVC6000 SIS for Safety Instrumented
valve controller is designed for yoke mounting to
System (SIS) Solutions, and DVC6000f for
sliding−stem actuators. DVC6020 / DVC6020 SIS /
FOUNDATIONt fieldbus.
DVC6020f digital valve controllers are designed for
mounting to rotary actuators or long−stroke
Refer to the appropriate product bulletin, listed in
sliding−stem actuators (over 4 inches travel).
Related Documents, for additional information about
DVC6030 / DVC6030 SIS / DVC6030f digital valve
these digital valve controllers.
controllers are designed for mounting on virtually
any quarter−turn actuator. Dimensions for
valve−mounted instruments are shown in figures 1,
2, and 3. Dimensions for remote mounted
instruments are shown in figures 4, 5, 6, 7, and 8.
Contents
Dimensions
DVC6010 / DVC6010 SIS / DVC6010f Digital
Valve Controller with Integrally The DVC6005 / DVC6005 SIS / DVC6005f base unit
Mounted Filter Regulator . . . . . . . . . . . . . . . . . 2 may be remote mounted on 2 inch pipestand or wall.
DVC6020 / DVC6020 SIS / DVC6020f Digital The remote−mount base unit connects to the
Valve Controller with Integrally DVC6015, DVC6025, or DVC6035 feedback unit
Mounted Filter Regulator . . . . . . . . . . . . . . . . . 3 mounted on the actuator. Feedback wiring and
DVC6030 / DVC6030 SIS / DVC6030f Digital pneumatic tubing to the control valve assembly must
Valve Controller with Integrally be connected in the field.
Mounted Filter Regulator . . . . . . . . . . . . . . . . . 4
DVC6005 / DVC6005 SIS / DVC6005f
Base unit;
Pipestand Mounted . . . . . . . . . . . . . . . . . . . . . 5 The digital valve controllers are loop powered and
Wall Mounted . . . . . . . . . . . . . . . . . . . . . . . . . . 6 do not require additional power. Electrical
DVC6015 Feedback Unit; Sliding−Stem connections are made in the terminal box.
Actuator Mounting up to
102 mm (4 inch) Travel . . . . . . . . . . . . . . . . . . . 6
DVC6025 Feedback Unit; Rotary and
Long−Stroke Sliding−Stem All pressure connections on the digital valve
Actuator Mounting . . . . . . . . . . . . . . . . . . . . . . . 7 controllers are 1/4 NPT internal connections. The
DVC6035 Feedback Unit; Rotary digital valve controller outputs are typically
Actuator Shaft Mounting . . . . . . . . . . . . . . . . . . 7 connected to the actuator inputs using 3/8−inch
Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 diameter tubing. Remote venting is available. D103308X012

www.Fisher.com
Product Bulletin
62.1:DVC6000(S1)
FIELDVUE Digital Valve Controllers February 2009

189.1
(7.44)
28.6 122.8
(1.13) (4.84)

2 MOUNTING HOLES
j 8.6 (0.34)

FEEDBACK
ARM

144.5
(5.69)

1/4−18 NPT
ACTUATOR OUTPUT CONN
CENTERLINE PLUGGED

1/2−14 NPT
148.7
CONDUIT CONN
(5.85)
BOTH SIDES

1/4−18 NPT
OUTPUT CONN A

FISHER 67CFR
1/4−18 NPT
SUPPLY CONN

210.7
(8.29)

3/8−18 NPT
VENT CONN

1/4−18 NPT
OUTPUT CONN B
201.8 mm
48B7710 Sht 1 / Doc. (7.94) (INCH)
19B3538−C
E0405−2 / IL

Figure 1. FIELDVUE DVC6010 / DVC6010 SIS / DVC6010f Digital Valve Controller with Integrally Mounted Filter Regulator

2
Product Bulletin
62.1:DVC6000(S1)
February 2009 FIELDVUE Digital Valve Controllers

MOUNTING
BRACKET

FEEDBACK
ARM
156.3
(6.16)
1/2−14 NPT
CONDUIT CONN
BOTH SIDES
1/4−18 NPT
OUTPUT
CONN A

FISHER 67CFR
1/4−18 NPT
SUPPLY CONN

234.7
(9.24)

95.3
(3.75)

157.7
(6.21)
1/4−18 NPT
OUTPUT CONN B
201.8
4 MOUNTING
(7.94)
HOLES
j 9.7 (0.38)

174.6
(6.88)

1/4−18 NPT
OUTPUT CONN
ACTUATOR PLUGGED
CENTERLINE 91.5 mm
(3.6) (INCH)

48B9596 Sht 1 / Doc


19B3557−C
E0406−2 / IL

Figure 2. FIELDVUE DVC6020 / DVC6020 SIS / DVC6020f Digital Valve Controller with Integrally Mounted Filter Regulator

3
Product Bulletin
62.1:DVC6000(S1)
FIELDVUE Digital Valve Controllers February 2009

FEEDBACK
ARM

125
(4.91) 1/2−14 NPT
CONDUIT CONN
BOTH SIDES

1/4−18 NPT
OUTPUT CONN A

FISHER 67CFR
1/4−18 NPT
210.7 SUPPLY CONN
(8.29)

3/8−18 NPT
VENT CONN

1/4−18 NPT 201.8


OUTPUT CONN B (7.94)

1/4−18 NPT
148.1 OUTPUT
(5.83) CONN
PLUGGED mm
214.7
(INCH)
(8.45)

48B9597 Sht 1 / Doc


19B3558−D
E0407−2 / IL

Figure 3. FIELDVUE DVC6030 / DVC6030 SIS / DVC6030f Digital Valve Controller with Integrally Mounted Filter Regulator

4
Product Bulletin
62.1:DVC6000(S1)
February 2009 FIELDVUE Digital Valve Controllers

63 193
(2.46) (7.60)

92
(3.62)

1/2−14 NPT CONDUIT


CONN BOTH SIDES

1/4−18 NPT 1/2−14 NPT


OUTPUT CONN A CONDUIT CONN
BOTH SIDES
151
(5.93)

234
(9.20)
1/4 −18 NPT
SUPPLY CONN

211
(8.29)

1/4−18 NPT
OUTPUT CONN B

10C1795−A / DOC
10C1796−A / DOC 3/8 −18 NPT mm
E1102
VENT CONN (INCH)

Figure 4. FIELDVUE DVC6005 / DVC6005 SIS / DVC6005f Base Unit; Pipestand Mounted

5
Product Bulletin
62.1:DVC6000(S1)
FIELDVUE Digital Valve Controllers February 2009

64
(2.50)

57
(2.25)

BRACKET LOCATION
FOR WALL MOUNTING

184
(7.23) 72
(2.82)

2 MOUNTING mm
10C1795−A / DOC HOLES 0.86 (0.34) (INCH)
10C1796−A / DOC
E1103

Figure 5. FIELDVUE DVC6005 / DVC6005 SIS / DVC6005f Base Unit; Wall Mounted

57
(2.25)

29
(1.13)

2 MOUNTING 97
HOLES CENTERLINE OF (3.81)
8.6 (0.34) ACTUATOR

19
(0.76)

138
(5.45)

121
(4.75)

1/2−14 NPT
CONDUIT CONN
65
(2.54)

175
(6.89) mm
(INCH)

10C1797−A
E0867−2 / IL

Figure 6. FIELDVUE DVC6015 Feedback Unit; Sliding−Stem Actuator Mounting up to 102 mm (4 inch) Travel

6
Product Bulletin
62.1:DVC6000(S1)
February 2009 FIELDVUE Digital Valve Controllers
9
(0.37)
4 MOUNTING
HOLES
9.7 (0.38)

175
94 (6.88)
(7.63)

1/2−14 NPT
CONDUIT
CONN

99
(3.90) 95
10
(0.38) (3.75)
10C1798−A
E0868−2 / IL

114
(4.50)

140
(5.52) mm
(INCH)

Figure 7. FIELDVUE DVC6025 Feedback Unit; Rotary and Long−Stroke Sliding−Stem Actuator Mounting

76
(3.00)

38
(1.50)

46
(1.83)

120 93
(4.72) (3.66)

4 MOUNTING
HOLES
103 1/2−14 NPT 67 46 1/4−20 UNC
(2.65) CONDUIT (2.65) (1.81)
CONN

135
mm
(4.07)
(INCH)
10C1799−A
E0869 / IL

Figure 8. FIELDVUE DVC6035 Feedback Unit; Rotary Actuator Shaft Mounting

7
Product Bulletin
62.1:DVC6000(S1)
FIELDVUE Digital Valve Controllers February 2009

Related Documents Note


D Bulletin 62.1:DVC6000—Fisher FIELDVUE
DVC6000 Digital Valve Controllers (D102758X012) Neither Emerson, Emerson Process
Management, nor any of their affiliated
D Bulletin 62.1:DVC6000 SIS—Fisher FIELDVUE entities assume responsibility for the
DVC6000 SIS Series Digital Valve Controllers for selection, use, or maintenance of any
Safety Instrumented System (SIS) Solutions product. Responsibility for the
(D102784X012) selection, use, and maintenance of any
D Bulletin 62.1:DVC6000f—Fisher FIELDVUE product remains with the purchaser
DVC6000f Digital Valve Controllers (D103199X012) and end−user.

All documents are available from your Emerson


Process Management sales office. Also visit our
website at www.FIELDVUE.com.

Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co.
Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. HART is a mark
owned by the HART Communication Foundation. FOUNDATION fieldbus is a mark owned by the Fieldbus Foundation. All other marks are the
property of their respective owners.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they
are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the
designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their affiliated
entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of
any product remains solely with the purchaser and end−user.

Emerson Process Management


Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com

EFisher
8 Controls International LLC 2008, 2009; All Rights Reserved
Product Bulletin
51.1:ED
D100017X012
June 2010 ED Valve

Fisherr ED, EAD, and EDR


Sliding-Stem Control Valves
Fisher ED, EAD, and EDR single-port control valves
shown in figures 1, 2, 3, and 4 have balanced valve
plugs, cage guiding, and metal-to-metal seating for
all general applications over a wide range of process
pressure drops and temperatures. These general
purpose, sliding-stem valves are used for either
throttling or on-off control of a wide variety of liquids
and gases.

The Fisher ED product line is available for a wide


range of applications, including sulfide and chloride
stress-cracking environments common to the oil and
gas production industries. To discuss available
constructions, contact your Emerson Process
Management sales office and include the applicable
codes and standards required for these
environments.

The easy-et Valve Family


ED, EAD, and EDR valves are part of the versatile
easy-e family of Fisher industrial control valves.
easy-e valves share the following characteristics:

D Multiple trim material choices

D Trim temperature capability with standard metal


seats to 427_C (800_F)
D FGM gaskets
D Interchangeable, restricted-capacity trims and
full-size trims match variable process flow demands W19163 / IL

Figure 1. Fisher ED Control Valve with 667 Actuator


D Different cage/plug styles provide particular
flow characteristics for highly-specialized
applications. The standard cage comes in three D Noise in gaseous service may be attenuated by
different flow characteristics: using Whisper Trimt I, Whisper Trim III (figure 10),
and WhisperFlot cages (figure 12)
D quick-opening
D linear D 316 stainless steel packing box parts are
D equal percentage standard (including packing flange, studs, and nuts)

www.Fisher.com
Product Bulletin
51.1:ED
ED Valve June 2010

Contents D Valve Plug Stability— Rugged cage guiding


Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 provides high valve plug stability, which reduces
C-seal Trim Description . . . . . . . . . . . . . . . . . . . . . 6 vibration and mechanical noise.
ENVIRO-SEALt and HIGH-SEAL
Packing Systems . . . . . . . . . . . . . . . . . . . . . . . . 6 D More Flow Capacity for Initial Investment—
Tables Streamlined flow passages in the the ED, EAD, and
EDR valves provide excellent capacities and flow.
C-seal Shutoff Classification . . . . . . . . . . . . 5
Available Constructions . . . . . . . . . . . . . . . . 6
D Balanced Valve Plug Construction—
Typical Combinations of
Balanced valve plug construction permits use of
Metal Trim Parts . . . . . . . . . . . . . . . . . . . . 7
smaller, lower-cost Fisher actuators. Also, trim
WhisperFlo Metal Trim Part Materials inventory costs are cut because dimensional
and Valve Body/Trim Temperature standardization permits use of most standard easy-e
Capabilities . . . . . . . . . . . . . . . . . . . . . . . . 8 trim parts.
Materials and Temperature Limits for
All Other Parts . . . . . . . . . . . . . . . . . . . . 11 D High-Temperature Capability with Class IV
Valve Body/Trim or Class V Shutoff—Use of multiple graphite piston
Temperature Capabilities . . . . . . . . . . . 14 rings (figure 2) permit Class IV shutoff up to 593_C
Bonnet Selection Guidelines . . . . . . . . . . . 15 (1100_F).
Maximum Flow Coefficients . . . . . . . . . . . 15 Use of C-seal trim (see figure 6) permits Class V
Metal Trim Parts (NACE) . . . . . . . . . . . . . . 16 shutoff up to 593_C (1100_F).
Port Diameters, Valve Plug Travel, and
Stem and Yoke Boss Diameters . . . . . 17 D Compliance with European Standards—
Bolting Materials and Temperature Limits Valves are available with dimensions specified by
(NACE) . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 EN/DIN standards. See figure 14.
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Coefficients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 D Sour Service Capability— Unless otherwise
noted, references are to NACE MR0175-2002.
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Optional materials are available to meet NACE
ENVIRO-SEAL Packing System
MR0103 and NACE MR0175 / ISO 15156. Material
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 39 requirements under these standards vary by edition
and year of issue; the specific standard must be
specified.

Features D Operating Economy—Increased wear


resistance provided by standard hardened stainless
D Compliance with the Clean Air Act—Optional steel trim means long service life.
ENVIRO-SEAL packing systems (figure 7) provide
an improved stem seal to help prevent the loss of D Maintenance Economy—The valve body can
process fluid. The ENVIRO-SEAL packing systems stay in the pipeline during removal of trim parts. The
feature PTFE, Graphite ULF, or Duplex packing with EDR valve also features easy valve access without
live-loading for reduced packing maintenance. removing the actuator.

2
Product Bulletin
51.1:ED
June 2010 ED Valve

CAGE GASKET
SHIM

DOUBLE
PISTON RINGS
(SMALLER SIZES
LOAD
HAVE TRIPLE
BONNET RING
PISTON RINGS)
GASKET

RESTRICTED
SPIRAL TRIM
WOUND ADAPTORS
GASKET

W09774 / IL

RESTRICTED TRIM
W33621 / IL

NPS 8 VALVE WITH OPTIONAL MULTIPLE PISTON RINGS


FOR CLASS IV SHUTOFF
(ALSO AVAILABLE IN OTHER SIZES)

STEM

PTFE V-RING
PACKING
BONNET GASKET

BALANCING PORT
SHIM
GRAPHITE PISTON RING

CAGE
SPIRAL
WOUND GASKET
VALVE PLUG

PIN

SEAT RING
GASKET
SEAT RING

W04514 / IL

STANDARD NPS 1 THROUGH 6 CONSTRUCTION

Figure 2. Fisher ED Sectional

3
Product Bulletin
51.1:ED
ED Valve June 2010

OPTIONAL LINER

W09695 / IL

W20025 / IL

Figure 3. Fisher EAD Sectional


Figure 4. Fisher EDR Sectional

W6980 / IL

WhisperFlo TRIM

W6851-1 / IL

Figure 5. Typical Valve with WhisperFlo Aerodynamic Trim

4
Product Bulletin
51.1:ED
June 2010 ED Valve
Table 1. C-seal Shutoff Classification
VALVE VALVE SIZE PORT DIAMETER ANSI/FCI LEAKAGE
CAGE STYLE
(PRESSURE RATING) NPS mm Inches CLASS
2-1/2 73 2.875 Eq. %, Linear,
Whisper I, Cav III, 1
3 87.3 3.4375 stage
3 73 2.875
Cav III, 2 stage
4 73 2.875
Eq. %, Linear,
73 2.875
4 Whisper I, Cav III, 1 V to 593_C (1100_F)
111.1 4.375
stage [for port diameters
ED Whisper III (A3, B3, from 73 through 203.2
(CL150-600) 136.5 5.375 C3, D3), Cav III, 2 mm (2.875 through
stage 8-inch) with optional
6 C-seal trim]
Eq. %, Linear,
177.8 7 Whisper I, Cav III, 1
stage
177.8 7 Cav III, 2 stage

8 Eq. %, Linear,
203.2 8 Whisper I, Cav III, 1
stage

STAKE THREAD
FLOW DOWN

PISTON
RING

RETAINER

C-SEAL
METAL
PLUG
SEAL(1) VALVE PLUG

FLOW UP

C-SEAL
NOTES: METAL
1. REVERSE THE ORIENTATION OF THE C-SEAL PLUG SEAL PLUG
FOR PROPER SHUTOFF WHEN VALVE IS USED IN A PROCESS SEAL(1)
WITH DIFFERENT FLUID FLOW DIRECTION.
A6869 / IL

Figure 6. C-seal Trim

5
Product Bulletin
51.1:ED
ED Valve June 2010

Table 2. Available Constructions


VALVE BODY MATERIAL AND END CONNECTION STYLE(1)
VALVE Carbon Steel, Alloy Steel, or Stainless Steel Valve Body Cast Iron Valve Body
VALVE SIZE,
RF or RTJ Flanged Butt- Socket CL125 CL250
NPS Screwed
CL150 CL300 CL600 welding Weld FF Flanged RF Flanged
1, 1-1/2, or 2 X X X X X X X X
ED
2-1/2, 3, 4, 6, or 8 --- X X X X --- X X
1 or 2 --- X X X X --- --- ---
EAD
3, 4, or 6 --- X X X X --- --- ---
1, 1-1/2, or 2 X X X X X X X X
EDR
2-1/2, 3, or 4 --- X X X X --- X X
X = Available Construction.
1. End connection style abbreviations: FF - Flat Faced, RF - Raised Face, RTJ - Ring Type Joint.

C-seal Trim Description For applications requiring compliance with


environmental protection regulations, the unique
C-seal trim is available for valves with port diameters Fisher ENVIRO-SEAL packing system (figure 7) and
from 2.875 inches through 8 inches. a unique ENVIRO-SEAL bellows seal system
With C-seal trim, a balanced valve can achieve (figure 8) are offered. The emission control packing
high-temperature, Class V shutoff. Because the system keeps emission concentrations below the
C-seal plug seal is formed from metal (N07718 EPA 100 ppm requirement.
nickel alloy) rather than an elastomer, a valve
equipped with the C-seal trim can be applied in For an excellent stem seal in applications that are
processes with a fluid temperature of up to 593_C not environmentally-sensitive, the Fisher HIGH-SEAL
(1100_F). Graphite ULF packing system (figure 7) is offered.
The HIGH-SEAL packing system provides excellent
sealing at pressure/temperature ratings beyond
ENVIRO-SEAL limits. ENVIRO-SEAL systems may
ENVIRO-SEAL and HIGH-SEAL also be applied for excellent stem sealing in higher
Packing Systems pressure/temperature applications not requiring EPA
compliance.
ENVIRO-SEAL and HIGH-SEAL packing systems
offer exceptional sealing capabilities. They easily ENVIRO-SEAL packing systems, available with
install in your existing valves or can be purchased PTFE, Graphite ULF, or Duplex packing, and the
with new valves. These systems may help prevent HIGH-SEAL packing systems, Graphite ULF and
the loss of process fluid. The long operational life graphite composite, feature live-loading and unique
and reliability of these systems also reduces your packing-ring arrangements for long-term, consistent
maintenance costs and downtime. sealing performance.

6
Product Bulletin
51.1:ED
June 2010 ED Valve
Table 3. Typical Combinations of Metal Trim Parts(1) for all Valves Except Those for NACE Specification, Whisper Trim III, and
WhisperFlo Cages
Liner
Trim Designation Valve Plug Cage Seat Ring
(EAD Valve Only)
1 (standard for ED, EAD,
S41600 HT or
and EDR in all valve body materials S41600 HT CB7Cu-1 HT S41600 HT
CA15 HT(2)
except CF8M)
S31600
3 and 3H(3) with seat and guide hard faced with R30006 (alloy 6) R30006 (alloy 6) ---
CoCr-A hardfacing alloy
4(4) S31600 CB7Cu-1 HT S31600 S31600
S31600 with seat and guide
27 CF8M
hard faced with CoCr-A hardfacing alloy
with electroless R30006 (alloy 6) ---
S31600 with seat hard faced
28(5) nickel coating (ENC)
with CoCr-A hardfacing alloy
CF8M
29 (standard for CF8M
S31600 with electroless S31600 S31600
bodies in all designs)(5)
nickel coating (ENC)
S31600
37 and 37H(3) with seat and guide CB7Cu-1 HT R30006 (alloy 6)
hard faced with CoCr-A hardfacing alloy
1. Nonferrous-alloy combinations are also available. Consult your Emerson Process Managementt sales office for details.
2. CA15 is used for NPS 6 and 8 full-size and restricted-trim valves.
3. Trims 3H and 37H have clearances for high-temperature service.
4. Not for use with Whisper Trim I.
5. Not use with Whisper Trim I with 136 mm (5.375 inch) and larger ports.

Table 4. Whisper Trim III Metal Trim Part Materials and Body/Trim Temperature Capabilities (NPS 6 Fisher ED only)
MATERIAL
BAFFLE TEMPERATURE
TRIM
VALVE CAGE (FOR LEVEL SEAT BODY, BONNET CAPABILITY
DESIGNA- CAGE
PLUG RETAINER D3 CAGE RING & BONNET SPACER
TION _C _F
ONLY)
Min Max Min Max
301 (standard Carbon steel WCC carbon steel
for all body NACE with or WC9 chrome 29 343 20 650
materials S17400 HT S41600 HT electroless Steel 410 SST HT moly steel
except nickel coating
S31600) (ENC) CF8M (316 SST) 29 163 20 325
WCC carbon steel
301A S17400 HT S41600 WCC Nitrided Steel S41600 or WC9 chrome moly 232 427 450 800
steel
S31600 with Carbon steel S31600 with WCC carbon steel,
seat and guide NACE with seat hard 29 343 20 650
WC9 chrome moly steel
304 hard faced with S41600 HT electroless Steel faced with
CoCr-A hard- nickel coating CoCr-A hard-
CF8M (316 SST) 29 177 20 350
facing alloy (ENC) facing alloy
S31600 with Carbon steel S31600 with
S31600 with WCC carbon steel,
313 seat and guide NACE with seat hard
electroless WC9 chrome moly
(NACE hard faced with electroless Steel faced with 29 343 20 650
nickel coating steel, or
compatible)(1) CoCr-A hard- nickel coating CoCr-A hard-
(ENC) CF8M (316 SST)
facing alloy (ENC) facing alloy
S31600 with S31600 with WCC carbon steel or
seat and guide seat hard 29 260 20 500
Cr Ct Cr Ct WC9 chrome moly steel
315 hard faced with S31600 faced with
316 SST 316 SST
CoCr-A hard- CoCr-A hard-
CF8M (316 SST) 198 537(2) 325 1000(2)
facing alloy facing alloy
S31600 with S31600 WCC carbon steel 29 427 20 800
seat and guide with seat
318 WC9/Nitrided WC9/Nitrided WC9
hard-faced hard-faced
WC9 chrome moly steel 29 593 20 1100
with CoCr-A with CoCr-A
1. Level D3 cage cannot be certified to NACE. Use 316/ENC cage retainer instead.
2. May be used up to 593_C (1100_F) if manufacturing process controls carbon content to 0.04% minimum or 0.08% maximum.

7
Product Bulletin
51.1:ED
ED Valve June 2010

Table 5. WhisperFlo Metal Trim Part Materials and Valve Body/Trim Temperature Capabilities (NPS 4 and 6 Fisher ED only)
TRIM MATERIAL TEMPERATURE CAPABILITY
VALVE VALVE CAGE
DESIGNA- CAGE SEAT _C _F
BODY PLUG RETAINER
TION Min Max Min Max
901 WCC S41600 S41000 WCC ENC S41600 29 343 20 650
S31600/CoCrA
902 WCC Seat and S41000 WCC ENC S31600/CoCrA 29 343 20 650
Guide
S31600/CoCrA
915 WCC Seat and S41000/Nitride WCC/Nitride S31600/CoCrA 343 427 650 800
Guide
S31600/CoCrA
916 WC9 Seat and S41000/Nitride WC9/Nitride S31600/CoCrA 343 538 650 1000
Guide
S31600/CoCrA
926 WCC Seat and S41000 NACE WCC/NACE/ENC S31600/CoCrA 29 343 20 650
Guide
S31600/CoCrA
316
936 Seat and S31603/CRCT S31600/ENC S31600/CoCrA 198 343 325 650
CF8M
Guide
S31600/CoCrA
316
946 Seat and S31603/CRCT S31600/Nitride S31600/CoCrA 343 538 650 1000
CF8M
Guide

8
Product Bulletin
51.1:ED
June 2010 ED Valve

PACKING
BOX PACKING
STUD BOX
STUDS

SPRING

SPRINGS

ANTI-
EXTRUSION
PACKING
FOLLOWER RING
RING
PACKING

LANTERN VALVE
BONNET
RING

W85331

TYPICAL HIGH-SEAL PACKING SYSTEM W58033 / IL

WITH GRAPHITE ULF PACKING TYPICAL ENVIRO-SEAL PACKING SYSTEM


WITH PTFE PACKING

PACKING
BOX
STUD

SPRINGS

FOLLOWER

PACKING

W8532-1
W7018 / IL

TYPICAL ENVIRO-SEAL PACKING SYSTEM TYPICAL ENVIRO-SEAL PACKING SYSTEM


WITH GRAPHITE ULF PACKING WITH DUPLEX PACKING

Figure 7. ENVIRO-SEAL and HIGH-SEAL Packing Systems

9
Product Bulletin
51.1:ED
ED Valve June 2010

W58521 / IL

Figure 8. Cutaway of ENVIRO-SEAL Bellows Seal Bonnet and Internal Shroud, Showing Bellows

10
Product Bulletin
51.1:ED
June 2010 ED Valve
Table 6. Materials and Temperature Limits for All Other Parts
PART MATERIAL MATERIAL TEMPERATURE CAPABILITY
_C _F
Min Max Min Max
Cast iron valve
body Cap screws Steel SAE Grade 5 29 232 20 450

WCC, or WC9 Studs Steel SA-193-B7


valve body 29 427(1) 20 800(1)
Nuts Steel SA-194-2H
Body-to-bonnet Studs Steel SA-193-B7
bolting. See LCC valve body 46 343(1) 50 650(1)
Nuts Steel SA-194-2H
table 12
for NACE Studs Steel SA-193-B16
bolting WC9 valve body 29 566(1) 20 1050(1)
Nuts Steel SA-194-7
materials
and Studs Steel SA-193-B7 (NACE [non-exposed bolting])
temperature 48 427(1) 55 800(1)
Nuts Steel SA-194-2H (NACE [non-exposed bolting])
limits
CF8M Studs 304 stainless steel SA-320-B8
(316 SST) 198 38 325 100
valve body Nuts 304 stainless steel SA-194-8
Studs 316 stainless steel SA-193-B8M (strain hardened)
198 (2) 427(1) 325 (2) 800(1)
Nuts 316 stainless steel SA-194-8M
Piston ring Oxidizing service 46(3) 427 50(3) 800
Graphite (FMS 17F27)
Non-oxidizing service 46(3) 482 50(3) 900
Oxidizing service 46(3) 560 50(3) 1000
Graphite (FMS17F39)
Non-oxidizing service 46(3) 593 50(3) 1100
Valve plug stem S31600 (S20910, NACE Std.)
Pin (ED or EAD valve only) S31600 198(2) 593 325(2) 1100
Castle nut and cotter pin (EDR valve only) 18-8 stainless steel
Load ring (NPS 8 ED valve only) S17400 101 316 150 600
N06600 254 593 425 1100
N05500 204 260 400 500
Restricted trim adaptors Cast iron 73 232 100 450
WCC steel 29 427 20 800
S31600 198(2) 593 325(2) 1100
Seat ring, bonnet and cage gaskets FGM (standard) 198 593(4) 325 1100(4)
PTFE-coated N04400 73 149 100 300
Spiral wound gaskets N06600/graphite (FGM-standard) 198 593(4) 325 1100(4)
N04400/composition 73 232 100 450
These materials not
Shim S31600 limiting factors
N04400
Packing PTFE V-ring 40 232 40 450
(temperatures
shown are PTFE/composition 73 232 100 450
material
temperature Graphite ribbon/filament 198 538(6) 325 1000(6)
capabilities).
See table 8 for Graphite ribbon for high-temperature
proper bonnet oxidizing service 371 649 700 1200
selection.
Packing flange, studs and nuts when
used with standard bonnet S31600 198(2) 593(1) 325(2) 1100(1)

Packing follower, and packing spring(5) S31600


or lantern ring 198(2) 593 325(2) 1100
Packing box ring S31600
Extension Trims 1 &
37H S41600 29 427 20 800
bonnet
bushing Other trims S31600 198(2) 593 325(2) 1100
1. Lubricated nuts are standard.
2. May be used down to 254_C (425_F) if manufacturing process includes Charpy impact test.
3. This minimum is due to thermal expansion differential between piston ring and cage at low temperatures.
4. Except 427_C (800_F) on oxidizing service.
5. Spring is used only with single PTFE V-ring packing; lantern ring replaces spring in other packings.
6. Except 371_C (700_F) on oxidizing service.

11
Product Bulletin
51.1:ED
ED Valve June 2010

FLUID TEMPERATURE, _C
0 200 400
1500
FLUID TEMPERATURE, _C 100
1400
0 100 200
600 41.4
40 1200
80

PRESSURE DROP, BAR


37
35
500

PRESSURE DROP, PSI


PRESSURE DROP, BAR
1000
PRESSURE DROP, PSI

37H
30
1, 37, OR 29 3 2 60
400 25 800

300 20 600 40
1
15 1 OR 37H 2
200 4, 29
400
10
20
100
5 200
1 OR 29 4
0 0 0 0
100 0 100 200 300 400 500
100 0 100 200 300 400 500 600 700 800
20 450 20
FLUID TEMPERATURE, _F 50 FLUID TEMPERATURE, _F

WITH CL250B 1 WITH CL600 1


CAST IRON VALVE BODY WCC OR LCC STEEL VALVE BODY

FLUID TEMPERATURE, _C FLUID TEMPERATURE, _C


100 0 200 400 600 200 0 200 400 600

100 100
1400 1400

1200 1200
80 80

PRESSURE DROP, BAR


PRESSURE DROP, BAR
PRESSURE DROP, PSI

1000
PRESSURE DROP, PSI

1000
60 28 OR 29 3 60
800 1, 3, 800
37H
27
600 2 600 40
1, 3, 37 40

400 400

3H 20 20
200 200
2 29 4

0 0 0 0
200 0 400 800 1200 400 0 400 650 800 1200
20 410 1100 325
FLUID TEMPERATURE, _F
FLUID TEMPERATURE, _F

WITH CL600 1 WITH CL600 1


WC9 CHROME MOLY STEEL VALVE BODY 316 STAINLESS STEEL (CF8M) VALVE BODY

NOTES:
1 DO NOT EXCEED THE MAXIMUM PRESSURE AND TEMPERATURE FOR THE PRESSURE RATING OF
THE VALVE MATERIAL USED, EVEN THOUGH THE TRIMS SHOWN MAY HAVE HIGHER CAPABILITIES.
2 BE ESPECIALLY CAREFUL TO SPECIFY SERVICE TEMPERATURE IF TRIM 3 OR 37 IS SELECTED
AS DIFFERENT THERMAL EXPANSION RATES REQUIRE SPECIAL PLUG CLEARANCES. SPECIFY
TRIM 37H FOR TEMPERATURES ABOVE 210_C (410_F). SPECIFY TRIM 3H FOR TEMPERATURES
ABOVE 427_C (800_F).
3 TRIM 29 MAY BE USED UP TO 103 BAR (1500 PSI) WITH CLEAN, DRY GAS.
4 USE TRIM 27 INSTEAD OF TRIM 29 FOR NONLUBRICATING FLUIDS SUCH
AS SUPERHEATED STEAM OR DRY GASES BETWEEN 149 AND 316_C (300 AND 600_F).
B14707 / IL

Figure 9. Typical Trim Used for All Valves Except NPS 4 and 6 Fisher ED with Whisper Trim III Cage and WhisperFlo Cage

12
Product Bulletin
51.1:ED
June 2010 ED Valve

BONNET
SPACER

CAGE
RETAINER

W33322 / IL

Figure 10. Whisper Trim III Cage in NPS 6 Fisher ED Valve

FLUID TEMPERATURE, _C

0 200 400 600 FLUID TEMPERATURE, _C

1600 200 0 200 400 600

100 100
1400 1400

1200 1200
80 80

PRESSURE DROP, BAR


PRESSURE DROP, BAR
PRESSURE DROP, PSI

1000
PRESSURE DROP, PSI

1000 301A,
318
60 60
800 800
301, 301A,
318 315
600 40 600 40
304 OR 313
315
400 400
318
20 20
200 200

0 0 0 0
200 0 400 800 1200 400 0 400 650 800 1200
20 1050 325 20
FLUID TEMPERATURE, _F FLUID TEMPERATURE, _F

WITH CL600 WCC STEEL WITH CL600 1


OR WC9 CHROME MOLY BODY 316 STAINLESS STEEL (CF8M) BODY

NOTES:
1 DO NOT EXCEED THE MAXIMUM PRESSURE AND TEMPERATURE FOR THE PRESSURE RATING
OF THE BODY MATERIAL USED, EVEN THOUGH THE TRIM SHOWN MAY HAVE HIGHER CAPABILITIES.

A27034 / IL

Figure 11. Typical Trim Used for NPS 6 Fisher ED Valves with Whisper Trim III Cages

13
Product Bulletin
51.1:ED
ED Valve June 2010

Table 7. Valve Body/Trim Temperature Capabilities(1) For All Valves Except NPS 6 Fisher ED with Whisper Trim III Cage and NPS 4
and 6 ED with WhisperFlo Cage
MATERIAL
TEMPERATURE
VALVE BODY/BONNET(2) TRIM CAPABILITY
VALVE SIZE AND DESIGN
MATERIAL DESIGNATION
_C _F
Min Max Min Max
1, 3, 27, or 29 All 29 232 20 450
Cast iron 37 All 29 210 20 410
37H All 210 232 410 450
1 All 29 427 20 800
4 All 29 210 20 410
All (except limited to 338_C [640_F] for
27 29 343 20 650
WCC steel NPS 4 and 6)
29 All 29 149(4) 20 300(4)
37 All 29 210 20 410
37H All 210 427 410 800
1 or 3 All 29 427 20 800
All (except limited to 338_C [640_F] for
27 29 343 20 650
NPS 4 and 6)
WC9 chrome moly 29 All 29 149(4) 20 300(4)
steel
37 All 29 210 20 410
3H All 427 593 800 1100
37H All 210 427 410 800
1 All 29 343 20 650
4 All 46 210 50 410
All (except limited to 338_C [640_F] for
27 46 343 50 650
LCC steel NPS 4 and 6)
29 All 46 149(4) 50 300(4)
37 All 46 210 50 410
37H All 210 343 410 650
27 All 198(3) 343 325(3) 650
CF8M (316 198(3) 149(4) 325(3) 300(4)
28 All
stainless steel)
29 All 198(3) 149(4) 325(3) 300(4)
1. For metal trim parts only. Restricted trim and full-sized limits are the same.
2. Same material also used for bottom flange, if required.
3. May be used down to 254_C (425_F) if manufacturing process includes Charpy impact test.
4. Lubricating service allows usage to 316_C (600_F).

W7065 / IL
W6851-1 / IL

Figure 12. WhisperFlo Cage in NPS 4 and 6 Fisher ED Valve

14
Product Bulletin
51.1:ED
June 2010 ED Valve
Table 8. Bonnet Selection Guidelines
IN-BODY PROCESS TEMPERATURE LIMITS(1)
BONNET STYLE PACKING MATERIAL
_C _F
Plain: PTFE V-ring 18 to 232 0 to 450
J Standard for all valves through
NPS 6 valve body with 2-13/16 yoke PTFE/Composition 18 to 232 0 to 450
boss diameter
J Standard for NPS 6 and 8 valves in cast 18 to maximum shown 0 to maximum shown
iron and WCC steel bonnet material with Graphite ribbon/filament
in table 6 in table 6
3-9/16 yoke boss diameter
Style 1 Cast Extension: PTFE V-ring
46 to 427 50 to 800
J Standard for NPS 8 valves in S31600 PTFE/Composition
bonnet material with 3-9/16 yoke boss 46 to to maximum shown 50 to maximum shown
diameter Graphite ribbon/filament
in table 6 in table 6
Style 2 Cast Extension: PTFE V-ring
J Optional for NPS 2 through 4 valves with 101 to 427 150 to 800
2-13/16 inch yoke boss diameter PTFE/Composition
J Optional for NPS 6 and 8 valves
with 3-9/16 yoke boss diameter. Not 101 to maximum shown 150 to maximum shown
available for NPS 8 valve in S31600 Graphite ribbon/filament
in table 6 in table 6
bonnet material
For exceptional stem sealing capabilities. See
PTFE Bulletin 59.1:070, ENVIRO-SEAL Bellows Seal
ENVIRO-SEAL bellows seal bonnet Bonnets, for pressure/temperature ratings.
Graphite ULF
1. These in-body process temperatures assume an outside, ambient temperature of 21_C (70_F) and no insulation on the bonnet. When using any packing at low process temperatures,
a cast extension bonnet may have to be used to prevent packing damage which could result from the formation of valve stem frost. Material selection for trim and other components will
also be limiting factors.

Table 9. Maximum Flow Coefficients for Full-Sized Trim with


Equal Percentage Cage and Normal Flow Direction
Valve Valve Size, NPS Cv at Max. Valve Plug Travel
1 17.2
1-1/2 35.8
ED 2 59.7
2-1/2 99.4
3 136
4 224
6 394
8(1) 567
8(2) 819
1 18.5
2 48.1
with liner 3 149
4 152
6 336
EAD
1 19.0
2 47.2
without
3 148
liner
4 156
6 328
1 17.2
1-1/2 35.8
2 59.7
EDR
2-1/2 99.4
3 136
4 224
1. With 51 mm (2 inch) travel.
2. With 76 mm (3 inch) travel.

15
Product Bulletin
51.1:ED
ED Valve June 2010

Table 10. Metal Trim Part Materials for Compatibility with NACE MR0175 / ISO 15156 and MR0103 (Sour Service) Specifications,
Environmental Restrictions Apply, Refer to Standard. Contact your Emerson Process Management Sales Office for information on
NACE MR0175 / ISO 15156 and NACE MR0103.
Seat Ring Optional Valve Stem, Packing
for Standard Liner for Follower, Lantern
Trim Designation Valve Plug Cage Load Ring(1)
Metal Seat Metal Seat Ring, Packing Box
Construction (EAD only) Ring, and Pin
S31600 with
85(2) S31600 electroless nickel S31600 S31600
coating (ENC)
S31600
S31600 with
with seat hard S20910 (Valve Stem)
86(2) electroless nickel R30006 (alloy 6) ---
faced with CoCr-A S31600 N05500
coating (ENC)
hardfacing alloy (All Other Parts)
S31600
S31600 with
with seat and
87 electroless nickel R30006 (alloy 6) ---
guide hard faced
coating (ENC)
with CoCr-A hardfacing alloy
1. NPS 8 valve only.
2. Not use with Whisper Trim I with 136 mm (5.375 inch) and larger ports.

16
Product Bulletin
51.1:ED
June 2010 ED Valve
Table 11. Port Diameters, Valve Plug Travel, and Stem and Yoke Boss Diameters
MAX VALVE
PORT
VALVE SIZE, NPS PLUG STEM AND YOKE BOSS DIAMETERS
DIAMETER
TRAVEL
ED or EDR EAD Standard Optional
Restricted- Restricted- Stem Yoke Boss Stem Yoke Boss
Full-Sized Full-Sized
Capacity Capacity
Trim Trim mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch
Trim Trim
1 1-1/2 1 2 33.3 1.3125 19 0.75 9.5 3/8 54 2-1/8 12.7 1/2 71 2-13/16
--- 2 --- --- 33.3 1.3125 19 0.75 12.7 1/2 71 2-13/16 --- --- --- ---
1-1/2 --- 2 --- 47.6 1.875 19 0.75 9.5 3/8 54 2-1/8 12.7 1/2 71 2-13/16
--- 2-1/2 --- 3 47.6 1.875 19 0.75 1.7 1/2 71 2-13/16 --- --- --- ---
2 3 --- 4 58.7 2.3125 29 1.125 12.7 1/2 71 2-13/16 19.1 3/4 90 3-9/16
2-1/2 4 3 6 73.0 2.875 38 1.5 12.7 1/2 71 2-13/16 19.1 3/4 90 3-9/16
3 --- 4 --- 87.3 3.4375 38 1.5 12.7 1/2 71 2-13/16 19.1 3/4 90 3-9/16
87(3) 3.4375(3) 76(3) 3(3) 19.1 3/4 90 3-9/16
4 --- 6 --- 4.375
12.7 1/2 71 2-13/16
111.1 51 2 25.4 1 127 5
177.8(2) 7(2) 51(2) 2(2)
6(1) --- --- --- 25.4 1
136(3) 5.375(3) 76(3) 3(3)
19.1 3/4 90 3-9/16 or or 127 5
51 2 1-1/4
8(1) --- --- --- 203.2 8 31.8
76 3
1. Not available in EDR valve.
2. Standard-travel cages.
3. Whisper Trim III (NPS 6 ED) and WhisperFlo cages (NPS 4 and 6 ED).

Table 12. Bolting Materials and Temperature Limits for Compatibility with NACE MR0175-2002, NACE MR0175/ISO 15156, and
NACE MR0103. Environmental restrictions may apply
VALVE BODY TEMPERATURE
MATERIAL CAPABILITIES
BOLTING MATERIAL
_C _F
Min Max Min Max
Non-exposed bolting (Standard)
WCC and Studs Steel SA-193-B7
48(2) 427 55(2) 800
CF8M (316 SST) Nuts Steel SA-194-2H
Exposed bolting (Optional)
Requires Derating of Valve(1) When These Body-to-Bonnet Bolting Materials are Used
Studs Steel SA-193-B7M
WCC and CF8M 48(2) 427 55(2) 800
Nuts Steel SA-194-2HM
1. Derating is not required for CL300 valves. Derating may be required for valves rated at CL600. Contact your Emerson Process Management sales office for assistance in determining
the derating of valves when these body-to-bonnet bolting materials are used.
2. 29_C (20_F) with WCC valve body material.

17
Product Bulletin
51.1:ED
ED Valve June 2010

FLUID TEMPERATURE, _C FLUID TEMPERATURE, _C


100 0 100 200 300 400 200 0 200 400 600
1600 110 1600 110

100 100
1400 1400

1200 1200

PRESSURE DROP, BAR


80 80
PRESSURE DROP, PSI

PRESSURE DROP, PSI

PRESSURE DROP, BAR


1000 1000
60 86 60
800 800
86 87
87
600 40 600 40

400 400
20 20
200 200
2 85 2 85
0 0 0 0
200 100 0 100 200 300 400 500 600 700 400 0 400 650 800 1200
50 325 100
FLUID TEMPERATURE, _F
FLUID TEMPERATURE, _F

FOR STANDARD METAL SEATING WITH FOR STANDARD METAL SEATING WITH CL600 1
CL600 1 WCC OR LCC VALVE BODY 316 STAINLESS STEEL (CF8M) VALVE BODY
NOTES:
1 DO NOT EXCEED THE MAXIMUM PRESSURE AND TEMPERATURE FOR THE PRESSURE RATING
OF THE VALVE MATERIAL USED, EVEN THOUGH THE TRIM SHOWN MAY HAVE HIGHER CAPABILITIES.
2 USE TRIM 87 INSTEAD OF TRIM 85 FOR NONLUBRICATING FLUIDS SUCH
AS SUPERHEATED STEAM OR DRY GASES BETWEEN 149 AND 316_C (300 AND 600_F).
C05752 / IL

Figure 13. Typical Trim Used for NACE MR0175 / ISO 15156 and NACE MR0103. Environmental restrictions may apply

18
Product Bulletin
51.1:ED
June 2010 ED Valve

Table 13. Fisher ED and EDR Dimensions


A G (MAX)
VALVE Pressure Rating, End Connection Style(1)
SIZE,
NPS Scrd CL125 FF CL150 CL250 RF or BW or
CL300 RTJ CL600 RTJ PN16-40(2) PN63-100(2) ED EDR
or SW or 150 RF RTJ 300 RF CL600 RF
mm
1 210 184 197 197 210 210 210 160 230 60 119
1-1/2 251 222 235 235 248 251 251 200 260 71 116
2 286 254 267 267 282 286 289 230 300 78 133
2-1/2 --- 276 292 292 308 311 314 290 340 90 159
3 --- 298 311 317 333 337 340 310 380 97 168
4 --- 353 365 368 384 394 397 350 430 129 192
6 --- 451 464 473 489 508 511 480 550 162 ---
8 --- 543 556 568 584 610 613 600 650 191 ---
Inch
1 8.25 7.25 7.75 7.75 8.25 8.25 8.25 2.38 4.69
1-1/2 9.88 8.75 9.25 9.25 9.75 9.88 9.88 2.81 4.56
2 11.25 10.00 10.50 10.50 11.12 11.25 11.38 3.06 5.25
See See
2-1/2 --- 10.88 11.38 11.50 12.12 12.25 12.38 3.56 6.25
mm mm
3 --- 11.75 12.25 12.50 13.12 13.25 13.38 3.81 6.62
below below
4 --- 13.88 14.38 14.50 15.12 15.50 15.62 5.06 7.56
6 --- 17.75 18.25 18.62 19.25 20.00 20.12 5.50 ---
8 --- 21.38 21.88 22.38 23.00 24.00 24.12 7.50 ---
1. End connection style abbreviations: BW - Buttwelding, FF - Flat Faced, Scrd - Screwed, SW - Socketweld, RF - Raised Face, RTJ - Ring Type Joint.
2. Valves which meet EN flange standards and have EN face-to-face dimensions are available only from Europe. Valves which meet EN flange standards but not EN face-to-face
standards are available in the US. Consult your Emerson Process Management sales office.

MATCH LINE
MATCH LINE
FOR
FOR
ACTUATOR
ACTUATOR

G
G

1 1
B B

A A
10A7397B
AR4967a A09261 / IL
A09252 / IL

NOTES: ED VALVE BODY EDR VALVE BODY


A
1 B+
2

Figure 14. Fisher ED and EDR Dimensions (also see tables 13, 14, and 15)

19
Product Bulletin
51.1:ED
ED Valve June 2010

Table 14. Fisher ED and EDR Dimensions


D FOR PLAIN BONNET

VALVE ED EDR
SIZE, Stem Diameter Stem Diameter
NPS mm
9.5 12.7 19.1 25.4 or 31.8 9.5 12.7 19.1
1 127 149 --- --- 113 124 ---
1-1/2 124 146 --- --- 122 133 ---
2 --- 165 162 --- --- 148 140
2-1/2 --- 187 184 --- --- 157 152
3 --- 191 187 --- --- 167 159
4 --- 221 217 238 --- 198 191
6(1) --- --- 251 270 --- --- ---
6(2) --- --- 312 330 --- --- ---
8 --- --- 375(3) --- --- --- ---
Inch
3/8 1/2 3/4 1 or 1-1/4 3/8 1/2 3/4
1 5.00 5.88 --- --- 4.44 4.88 ---
1-1/2 4.88 5.75 --- --- 4.81 5.25 ---
2 --- 6.50 6.38 --- --- 5.81 5.50
2-1/2 --- 7.38 7.25 --- --- 6.31 6.00
3 --- 7.50 7.38 --- --- 6.56 6.25
4 --- 8.69 8.56 9.38 --- 7.81 7.50
6(1) --- --- 9.88 10.62 --- --- ---
6(2) --- --- 12.26 13.00 --- --- ---
8 --- --- 14.75(3) --- --- --- ---
1. All except Whisper Trim III and WhisperFlo cages.
2. Whisper Trim III and WhisperFlo cages.
3. Available only in cast iron or WCC steel for the stem diameter with plain bonnet.

Table 15. Fisher ED and EDR Dimensions


D FOR EXTENSION AND ENVIRO-SEAL BELLOWS SEAL BONNETS (ED ONLY)

VALVE Style 1 Ext. Bonnet Style 2 Ext. Bonnet ENVIRO-SEAL Bellows Seal Bonnet
SIZE, Stem Diameter Stem Diameter Stem Diameter
NPS mm
9.5 12.7 19.1 25.4 or 31.8 9.5 12.7 19.1 9.5 12.7 19.1
1 213 251 --- --- 303 319 --- 321 --- ---
1-1/2 210 248 --- --- 300 316 --- 317 --- ---
2 --- 267 --- --- --- 465 --- --- 384 ---
2-1/2 --- 289 272 --- --- 492 --- --- --- ---
3 --- 292 297 --- --- 495 487 --- 518 518
4 --- 322 327 370 --- 526 518 --- 541 ---
6(1) --- --- 357 402 --- --- 543 --- --- 573
6(2) --- --- 418 462 --- --- 604 --- --- ---
8 --- --- 421 450 --- --- 621 --- --- ---
Inch
3/8 1/2 3/4 1 or 1-1/4 3/8 1/2 3/4 3/8 1/2 3/4
1 8.38 9.88 --- --- 11.94 12.56 --- 12.62 --- ---
1-1/2 8.25 9.75 --- --- 11.81 12.44 --- 12.50 --- ---
2 --- 10.50 --- --- --- 18.31 --- --- 15.12 ---
2-1/2 --- 11.38 10.69 --- --- 19.38 --- --- --- ---
3 --- 11.50 11.69 --- --- 19.50 19.19 --- 20.38 20.38
4 --- 12.69 12.88 14.56 --- 20.69 20.38 --- 21.31 ---
6(1) --- --- 14.06 15.81 --- --- 21.38 --- --- 22.56
6(2) --- --- 16.44 18.19 --- --- 23.76 --- --- ---
8 --- --- 16.56 17.75 --- --- 24.44 --- --- ---
1. Standard-travel cages.
2. Whisper Trim III and WhisperFlo cages.

20
Product Bulletin
51.1:ED
June 2010 ED Valve
Table 16. Fisher EAD Dimensions
AA MATCH LINE
FOR
VALVE CL150 CL300 CL600 ACTUATOR
SIZE, End Connection Style(1)
NPS RF RTJ RF RTJ BW, SW or RF RTJ
mm
1 92 98 98 105 105 105
2 127 133 133 141 143 144
3 149 156 159 167 168 170 DD
4 176 183 184 197 197 198
6 225 232 237 244 254 256
Inch
1 3.62 3.88 3.88 4.12 4.12 4.12
2 5.00 5.25 5.25 5.56 5.62 5.69
AA
3 5.88 6.12 6.25 6.56 6.62 6.69 NOTE:
4 6.94 7.19 7.25 7.56 7.75 7.81 FOR DIMENSIONS OF
6 8.88 9.12 9.31 9.62 10.00 10.06 VALVES WITH EN (OR
OTHER) END CON-
1. End connection style abbreviations: BW - Buttwelding, FF - Flat Faced, Scrd -
Screwed, SW - Socketweld, RF - Raised Face, RTJ - Ring Type Joint. NECTIONS. CONSULT
YOUR EMERSON SALES
OFFICE. AA
AU6190A
A09272 / IL

Figure 15. Fisher EAD Dimensions


(also see tables 16 and 17)

Table 17. Fisher EAD Dimensions


DD
Plain Bonnet Style 1 Extension Bonnet Style 2 Extension Bonnet ENVIRO-SEAL
VALVE Bellows Seal
SIZE, Stem Diameter Bonnet
NPS
mm
9.5 12.7 19.1 25.4 or 31.8 9.5 12.7 19.1 9.5 12.7 19.1
Contact
1 111 133 --- --- 197 235 --- 291 305 --- your
2 98 121 --- --- 184 223 --- 278 291 --- Emerson
3 --- 149 146 --- --- 251 256 --- 454 --- sales office.
4 --- 140 137 --- --- 241 246 --- 445 437
6 --- 144 141 187 --- 246 251 --- 449 441
Inch ENVIRO-SEAL
Bellows Seal
3/8 1/2 3/4 1 or 1-1/4 3/8 1/2 3/4 3/8 1/2 3/4 Bonnet
1 4.38 5.25 --- --- 7.75 9.25 --- 11.44 12.00 ---
Contact
2 3.88 4.75 --- --- 7.25 8.75 --- 10.94 11.44 ---
your
3 --- 5.88 5.75 --- --- 9.88 10.06 --- 17.88 ---
Emerson
4 --- 5.50 5.38 --- --- 9.50 9.69 --- 17.50 17.19
sales office.
6 --- 5.69 5.56 7.38 --- 9.69 9.88 --- 17.69 17.38

21
Product Bulletin
51.1:ED
ED Valve June 2010

Coefficients
Table 18. Fisher EAD, Quick Opening Cage, With Liner
Quick Opening
With Liner Characteristic
Maximum Coeffs.
Port Diameter Flow for 6 Valve Opening—Percent of Total Travel
Valve Travel(1)
Coeffi- mm FL(3)
Size, NPS
cient (0.25 in)
mm Inches mm Inches 10 20 30 40 50 60 70 80 90 100
Travel(2)
Cv 14.2 5.14 9.24 13.1 16.2 18.8 20.9 22.4 23.4 24.0 24.0 0.90
1 33.3 0.3125 19 0.75 Kv 12.3 4.45 7.99 11.3 14.0 16.3 18.1 19.4 20.2 20.8 20.8 ---
XT 0.800 0.629 0.703 0.761 0.809 0.775 0.713 0.677 0.652 0.630 0.630 ---
Cv 29.4 8.77 17.1 26.2 36.1 45.4 53.4 59.3 63.6 67.3 70.7 0.76
47.6 1.875 19 0.75 Kv 25.4 7.59 14.8 22.7 31.2 39.3 46.2 51.3 55.0 58.2 61.2 ---
XT 0.573 0.480 0.513 0.568 0.570 0.577 0.589 0.628 0.618 0.656 0.656 ---
2
Cv 17.3 5.91 10.1 15.1 21.7 29.4 37.3 43.7 48.5 52.4 55.2 0.60
33.3 1.3125
(4) (4) 19 0.75 Kv 15.0 5.11 8.74 13.1 18.8 25.4 32.3 37.8 42.0 45.3 47.7 ---
XT 0.543 0.404 0.584 0.570 0.522 0.478 0.431 0.396 0.370 0.344 0.326 ---
Cv 30.6 24.2 47.2 77.8 108 133 148 159 171 181 183 0.76
73.0 2.875 38 1.5 Kv 26.5 20.9 40.8 67.3 93.4 115 128 138 148 157 158 ---
XT 0.540 0.517 0.534 0.504 0.545 0.582 0.636 0.651 0.616 0.575 0.569 ---
3
Cv 29.8 7.96 15.5 25.7 37.4 49.0 61.2 72.5 83.1 92.8 102 0.60
47.6 1.875
(4) (4) 19 0.75 Kv 25.8 6.89 13.4 22.2 32.4 42.4 52.9 62.7 71.9 80.3 88.2 ---
XT 0.576 0.549 0.624 0.603 0.541 0.525 0.482 0.452 0.422 0.391 0.349 ---
Cv 37.1 22.3 46.3 77.1 117 155 180 197 212 230 235 0.72
87.3 3.4375 38 1.5 Kv 32.1 19.3 40.0 66.7 101 134 156 170 183 199 203 ---
XT 0.580 0.616 0.547 0.537 0.531 0.529 0.575 0.629 0.635 0.609 0.620 ---
4
Cv 31.4 14.4 28.3 46.1 66.7 87.5 107 124 138 149 160 0.61
58.7 2.3125
(4) (4) 29 1.125 Kv 27.2 12.5 24.5 39.9 57.7 75.7 92.6 107 119 129 138 ---
XT 0.548 0.509 0.533 0.505 0.486 0.482 0.465 0.443 0.416 0.387 0.354 ---
Cv 50.0 39.8 84.0 150 219 279 332 379 420 435 435 0.71
111.1 4.375 51 2 Kv 43.3 34.4 72.7 130 189 241 287 328 363 376 376 ---
XT 0.578 0.597 0.599 0.577 0.581 0.581 0.578 0.565 0.527 0.533 0.533 ---
6
Cv 38.7 23.9 47.1 74.9 109 142 174 201 219 244 248 0.59
73.0 2.875
(4) (4) 38 1.5 Kv 33.5 20.7 40.7 64.8 94.3 123 151 174 189 211 215 ---
XT 0.353 0.353 0.353 0.353 0.353 0.356 0.352 0.353 0.352 0.353 0.354 ---
1. When using 655-EAD as a control valve for on-off service, the maximum travel for sizing purposes is 0.75 inch (19 mm).
2. When sizing self-operated regulators, use coefficients listed for 0.25 inch (6 mm) travel.
3. At 100% travel.
4. Restricted trim.

22
Product Bulletin
51.1:ED
June 2010 ED Valve

Table 19. Fisher EAD, Quick Opening Cage, Without Liner


Quick Opening
Without Liner Characteristic
Maximum Coeffs. for
Valve Port Diameter Flow Valve Opening—Percent of Total Travel
Travel(1) 6 mm
Size, Coeffi- FL(3)
(0.25 in)
NPS mm Inches mm Inches cient 10 20 30 40 50 60 70 80 90 100
Travel(2)
Cv 14.8 5.07 9.36 13.6 16.8 19.2 20.9 22.2 23.1 23.6 23.7 0.87
1 33.3 0.3125 19 0.75 Kv 12.8 4.39 8.10 11.8 14.5 16.6 18.1 19.2 20.0 20.4 20.5 ---
XT 0.757 0.638 0.753 0.753 0.766 0.736 0.703 0.670 0.650 0.640 0.636 ---
Cv 28.0 8.06 15.7 24.9 34.3 43.1 51.0 57.1 61.4 64.6 67.2 0.87
47.6 1.875 19 0.75 Kv 24.2 6.97 13.6 21.5 29.7 37.3 44.1 49.4 53.1 55.9 58.1 ---
XT 0.629 0.531 0.621 0.623 0.631 0.641 0.638 0.656 0.676 0.686 0.682 ---
2
Cv 17.2 6.02 10.4 15.4 20.9 27.1 33.7 38.5 41.7 44.2 45.6 0.71
33.3 1.3125
(4) (4) 19 0.75 Kv 14.9 5.21 9.00 13.3 18.1 23.4 29.2 33.3 36.1 38.2 39.4 ---
XT 0.573 0.470 0.541 0.570 0.575 0.563 0.526 0.510 0.492 0.476 0.470 ---
Cv 39.2 23.4 47.9 78.7 108 128 142 153 163 171 171 0.81
73.0 2.875 38 1.5 Kv 33.9 20.2 41.4 68.1 93.4 111 123 132 141 148 148 ---
XT 0.576 0.588 0.573 0.534 0.573 0.635 0.662 0.654 0.626 0.600 0.605 ---
3
Cv 29.1 8.27 15.9 25.6 36.0 46.8 56.4 64.6 72.1 79.3 86.1 0.72
47.6 1.875
(4) (4) 19 0.75 Kv 25.2 7.15 13.8 22.1 31.1 40.5 48.8 55.9 62.4 68.6 74.5 ---
XT 0.609 0.488 0.603 0.610 0.594 0.575 0.574 0.569 0.561 0.530 0.490 ---
Cv 39.0 23.9 48.2 80.3 118 151 178 195 209 223 223 0.76
87.3 3.4375 38 1.5 Kv 33.7 20.7 41.7 69.5 102 131 154 169 181 193 193 ---
XT 0.562 0.588 0.566 0.554 0.556 0.580 0.610 0.659 0.669 0.644 0.650 ---
4
Cv 30.9 13.6 27.0 43.9 62.5 80.6 96.0 109 120 127 133 0.73
58.7 2.3125
(4) (4) 29 1.125 Kv 26.7 11.8 23.4 38.0 54.1 69.7 83.0 94.3 104 110 115 ---
XT 0.608 0.593 0.614 0.582 0.578 0.587 0.590 0.576 0.547 0.533 0.513 ---
Cv 45.8 37.6 79.6 142 207 265 311 351 383 398 398 0.76
111.1 4.375 51 2 Kv 39.6 32.5 68.9 123 179 229 269 304 331 344 344 ---
XT 0.652 0.680 0.652 0.639 0.639 0.655 0.686 0.683 0.666 0.657 0.667 ---
6
Cv 35.4 21.8 43.1 71.5 103 130 154 173 188 198 206 0.74
73.0 2.875
(4) (4) 38 1.5 Kv 30.6 18.9 37.3 61.8 89.1 112 133 150 163 171 178 ---
XT 0.671 0.624 0.650 0.652 0.618 0.659 0.659 0.646 0.620 0.595 0.568 ---
1. When using 655-EAD as a control valve for on-off service, the maximum travel for sizing purposes is 19 mm (0.75 inch).
2. When sizing self-operated regulators, use coefficients listed for 6 mm (0.25 inch) travel.
3. At 100% travel.
4. Restricted trim.

23
Product Bulletin
51.1:ED
ED Valve June 2010

Table 20. Fisher EAD, Linear Cage, With Liner

With Liner - Flow Down Linear


Characteristic
Valve Maximum Flow
Port Diameter Valve Opening—Percent of Total Travel
Size, Travel Coeffi- FL(1)
NPS mm Inches mm Inches cient 10 20 30 40 50 60 70 80 90 100
Cv 2.71 5.17 8.14 10.7 13.0 15.2 17.2 19.1 20.7 22.0 0.90
1 33.3 1.3125 19 0.75 Kv 2.34 4.47 7.04 9.26 11.2 13.1 14.9 16.5 17.9 19.0 ---
XT 0.632 0.692 0.719 0.772 0.786 0.777 0.755 0.722 0.682 0.634 ---
Cv 3.77 6.94 11.3 16.1 21.0 26.7 33.1 40.1 46.8 53.8 0.82
47.6 1.875 19 0.75 Kv 3.26 6.00 9.77 13.9 18.2 23.1 28.6 34.7 40.5 46.5 ---
XT 0.665 0.675 0.663 0.642 0.627 0.616 0.617 0.607 0.633 0.661 ---
2
Cv 2.95 5.49 8.65 12.1 15.7 19.3 23.4 29.7 35.7 41.0 0.66
33.3 1.3125
(2) (2) 19 0.75 Kv 2.55 4.75 7.48 10.5 13.6 16.7 20.2 25.7 30.9 35.5 ---
XT 0.474 0.592 0.587 0.581 0.579 0.584 0.564 0.487 0.451 0.426 ---
Cv 10.3 24.0 38.8 54.3 69.8 86.5 102 124 141 155 0.80
73.0 2.875 38 1.5 Kv 8.91 20.8 33.6 47.0 60.4 74.8 88.2 107 122 134 ---
XT 0.630 0.623 0.618 0.598 0.599 0.591 0.619 0.603 0.614 0.614 ---
3
Cv 3.37 6.45 10.6 15.3 19.8 25.3 32.2 40.1 48.4 58.1 0.74
47.6 1.875
(2) (2) 19 0.75 Kv 2.92 5.58 9.17 13.2 17.1 21.9 27.9 34.7 41.9 50.3 ---
XT 0.630 0.682 0.693 0.665 0.663 0.637 0.600 0.588 0.569 0.548 ---
Cv 12.7 31.6 54.1 77.8 103 128 149 171 191 208 0.78
87.3 3.4375 38 1.5 Kv 11.0 27.3 46.8 67.3 89.1 111 129 148 165 180 ---
XT 0.677 0.638 0.596 0.590 0.552 0.548 0.573 0.594 0.613 0.627 ---
4
Cv 6.70 15.3 25.2 37.0 50.2 64.5 79.4 94.6 110 124 0.66
58.7 2.3125
(2) (2) 29 1.125 Kv 5.80 13.2 21.8 32.0 43.4 55.8 68.7 81.8 95.2 107 ---
XT 0.705 0.590 0.596 0.573 0.536 0.509 0.493 0.490 0.471 0.445 ---
Cv 25.4 53.6 83.0 113 146 179 218 263 309 350 0.78
111.1 4.375 51 2 Kv 22.0 46.4 71.8 97.7 126 155 189 227 267 303 ---
XT 0.670 0.666 0.666 0.659 0.631 0.627 0.623 0.624 0.630 0.617 ---
6
Cv 10.6 25.2 41.1 57.7 76.1 94.8 116 139 168 195 0.67
73.0 2.875
(2) (2) 38 1.5 Kv 9.17 21.8 35.6 49.9 65.8 82.0 100 120 145 169 ---
XT 0.445 0.443 0.448 0.445 0.445 0.445 0.443 0.448 0.442 0.444 ---
1. At 100% travel.
2. Restricted trim.

24
Product Bulletin
51.1:ED
June 2010 ED Valve

Table 21. Fisher EAD, Linear Cage, Without Liner

Without Liner - Flow Down Linear


Characteristic
Valve Port Maximum Flow Valve Opening—Percent of Total Travel
Size, Diameter Travel Coeffi- FL(1)
NPS mm Inches mm Inches cient 10 20 30 40 50 60 70 80 90 100
Cv 2.90 5.78 8.85 11.6 13.9 16.0 18.0 19.7 21.2 22.3 0.89
1 33.3 1.3125 19 0.75 Kv 2.51 5.00 7.66 10.0 12.0 13.8 15.6 17.0 18.3 19.3 ---
XT 0.778 0.704 0.699 0.736 0.745 0.747 0.730 0.699 0.664 0.624 ---
Cv 3.68 6.98 11.3 15.9 20.8 26.4 32.7 39.2 45.7 52.5 0.84
47.6 1.875 19 0.75 Kv 3.18 6.04 9.77 13.8 18.0 22.8 28.3 33.9 39.5 45.4 ---
XT 0.676 0.667 0.684 0.666 0.624 0.627 0.632 0.625 0.655 0.679 ---
2
Cv 3.01 5.45 8.95 12.5 15.9 19.1 23.3 28.4 33.2 37.6 0.73
33.3 1.3125
(2) (2) 19 0.75 Kv 2.60 4.71 7.74 10.8 13.8 16.5 20.2 24.6 28.7 32.5 ---
XT 0.790 0.768 0.661 0.618 0.608 0.611 0.582 0.545 0.535 0.516 ---
Cv 10.9 25.1 41.3 58.4 75.7 93.9 112 128 143 153 0.83
73.0 2.875 38 1.5 Kv 9.43 21.7 35.7 50.5 65.5 81.2 96.9 111 124 132 ---
XT 0.736 0.638 0.591 0.548 0.538 0.532 0.543 0.583 0.619 0.631 ---
3
Cv 3.61 6.92 11.1 15.5 20.6 26.4 33.2 41.4 50.1 60.2 0.78
47.6 1.875
(2) (2) 19 0.75 Kv 3.12 5.99 9.60 13.4 17.8 22.8 28.7 35.8 43.3 52.1 ---
XT 0.623 0.721 0.694 0.684 0.663 0.630 0.602 0.570 0.568 0.546 ---
Cv 14.0 33.8 56.3 80.2 104 127 148 169 185 201 0.81
87.3 3.4375 38 1.5 Kv 12.1 29.2 48.7 69.4 90.0 110 128 146 160 174 ---
XT 0.640 0.638 0.611 0.588 0.570 0.568 0.593 0.622 0.660 0.664 ---
4
Cv 7.02 15.7 25.7 36.9 48.6 60.9 72.9 84.6 97.2 108 0.76
58.7 2.3125
(2) (2) 29 1.125 Kv 6.07 13.6 22.2 31.9 42.0 52.7 63.1 73.2 84.1 93.4 ---
XT 0.712 0.626 0.625 0.597 0.587 0.577 0.590 0.604 0.580 0.566 ---
Cv 24.2 51.2 81.8 109 140 171 208 256 300 341 0.78
111.1 4.375 51 2 Kv 20.9 44.3 70.8 94.3 121 148 180 221 260 295 ---
XT 0.643 0.697 0.666 0.693 0.672 0.668 0.684 0.663 0.668 0.662 ---
6
Cv 10.2 22.8 36.6 52.1 68.0 84.5 102 124 147 168 0.74
73.0 2.875
(2) (2) 38 1.5 Kv 8.82 19.7 31.7 45.1 58.8 73.1 88.2 107 127 145 ---
XT 0.592 0.651 0.661 0.635 0.619 0.619 0.615 0.584 0.568 0.556 ---
1. At 100% travel.
2. Restricted trim.

25
Product Bulletin
51.1:ED
ED Valve June 2010

Table 22. Fisher EAD, Equal Percentage Cage, With Liner

With Liner - Flow Down Equal Percentage


Characteristic
Valve Port Maximum Flow Valve Opening—Percent of Total Travel
Size, Diameter Travel Coeffi- FL(1)
NPS mm Inches mm Inches cient 10 20 30 40 50 60 70 80 90 100
Cv 1.02 1.49 2.07 2.70 3.92 5.68 8.18 11.7 15.5 18.5 0.93
1 33.3 1.3125 19 0.75 Kv 0.882 1.29 1.79 2.34 3.39 4.91 7.08 10.1 13.4 16.0 ---
XT 0.902 0.902 0.820 0.740 0.741 0.737 0.738 0.734 0.742 0.739 ---
Cv 1.44 2.38 3.54 5.10 7.60 11.6 18.1 26.9 37.8 48.1 0.83
47.6 1.875 19 0.75 Kv 1.25 2.06 3.06 4.41 6.57 10.0 15.7 23.3 32.7 41.6 ---
XT 0.619 0.649 0.671 0.678 0.666 0.639 0.574 0.578 0.578 0.576 ---
2
Cv 0.792 1.28 1.84 2.56 3.78 5.66 8.64 13.3 19.9 27.6 0.75
33.3 1.3125
(2) (2) 19 0.75 Kv 0.685 1.11 1.59 2.21 3.27 4.90 7.47 11.5 17.2 23.9 ---
XT 0.648 0.654 0.682 0.659 0.683 0.661 0.592 0.534 0.479 0.468 ---
Cv 4.38 7.99 12.1 16.5 24.2 36.5 56.6 85.9 116 151 0.78
73.0 2.875 38 1.5 Kv 3.79 6.91 10.5 14.3 20.9 31.6 49.0 74.3 100 131 ---
XT 0.783 0.746 0.680 0.652 0.620 0.588 0.551 0.525 0.553 0.550 ---
3
Cv 1.31 2.28 3.48 5.05 7.58 11.9 18.2 26.7 38.4 50.5 0.78
47.6 1.875
(2) (2) 19 0.75 Kv 1.13 1.97 3.01 4.37 6.56 10.3 15.7 23.1 33.2 43.7 ---
XT 0.804 0.758 0.719 0.725 0.696 0.634 0.637 0.611 0.561 0.530 ---
Cv 2.31 0.470 7.45 11.3 17.8 28.7 47.9 77.5 112 152 0.81
87.3 3.4375 38 1.5 Kv 2.00 0.41 6.44 9.77 15.4 24.8 41.4 67.0 96.9 131 ---
XT 0.780 0.780 0.791 0.726 0.652 0.630 0.565 0.546 0.549 0.545 ---
4
Cv 2.24 3.67 5.44 7.81 11.7 17.9 27.6 41.9 62.6 86.3 0.73
58.7 2.3125
(2) (2) 29 1.125 Kv 1.94 3.17 4.71 6.76 10.1 15.5 23.9 36.2 54.1 74.6 ---
XT 0.630 0.668 0.662 0.672 0.659 0.610 0.593 0.574 0.500 0.456 ---
Cv 5.54 11.0 18.1 30.9 51.7 84.3 136 205 276 336 0.74
111.1 4.375 51 2 Kv 4.79 9.52 15.7 26.7 44.7 72.9 118 177 239 291 ---
XT 0.727 0.684 0.657 0.624 0.599 0.585 0.590 0.587 0.573 0.576 ---
6
Cv 1.32 3.73 7.20 11.1 17.5 27.6 43.4 67.8 102 147 0.74
73.0 2.875
(2) (2) 38 1.5 Kv 1.14 3.23 6.23 9.60 15.1 23.9 37.5 58.6 88.2 127 ---
XT 0.455 0.458 0.454 0.457 0.453 0.454 0.454 0.455 0.454 0.454 ---
1. At 100% travel.
2. Restricted trim.

26
Product Bulletin
51.1:ED
June 2010 ED Valve

Table 23. Fisher EAD, Equal Percentage Cage, Without Liner

Without Liner - Flow Down Equal Percentage


Characteristic
Valve Port Maximum Flow Valve Opening—Percent of Total Travel
Size, Diameter Travel Coeffi- FL(1)
NPS mm Inches mm Inches cient 10 20 30 40 50 60 70 80 90 100
Cv 1.08 1.62 2.20 2.96 4.18 6.04 8.74 12.5 16.5 19.0 0.91
1 33.3 1.3125 19 0.75 Kv 0.934 1.40 1.90 2.56 3.62 5.22 7.56 10.8 14.3 16.4 ---
XT 0.912 0.860 0.808 0.771 0.742 0.706 0.693 0.699 0.697 0.694 ---
Cv 1.67 2.60 3.82 5.43 7.79 12.2 18.9 27.4 37.8 47.2 0.85
47.6 1.875 19 0.75 Kv 1.44 2.25 3.30 4.70 6.74 10.6 16.3 23.7 32.7 40.8 ---
XT 0.680 0.690 0.702 0.725 0.707 0.619 0.622 0.621 0.619 0.623 ---
2
Cv 1.11 1.55 2.05 2.87 4.07 5.95 8.84 13.4 19.6 26.8 0.79
33.3 1.3125
(2) (2) 19 0.75 Kv 0.960 1.34 1.77 2.48 3.52 5.15 7.65 11.6 17.0 23.2 ---
XT 0.938 0.899 0.848 0.789 0.761 0.692 0.636 0.568 0.519 0.507 ---
Cv 4.59 8.29 12.0 16.9 25.0 37.7 57.3 85.1 121 148 0.80
73.0 2.875 38 1.5 Kv 3.97 7.17 10.4 14.6 21.6 32.6 49.6 73.6 105 128 ---
XT 0.779 0.744 0.715 0.684 0.630 0.582 0.583 0.579 0.578 0.580 ---
3
Cv 1.56 2.51 3.68 5.40 7.65 11.7 18.2 27.0 37.3 47.8 0.84
47.6 1.875
(2) (2) 19 0.75 Kv 1.35 2.17 3.18 4.67 6.62 10.1 15.7 23.4 32.3 41.3 ---
XT 0.834 0.807 0.768 0.718 0.756 0.723 0.679 0.627 0.615 0.615 ---
Cv 2.51 5.10 8.03 12.0 18.7 30.7 47.4 80.3 116 156 0.81
87.3 3.4375 38 1.5 Kv 2.17 4.41 6.95 10.4 16.2 26.6 41.0 69.5 100 135 ---
XT 0.890 0.770 0.744 0.701 0..696 0.637 0.668 0.572 0.566 0.565 ---
4
Cv 2.33 3.56 5.64 8.18 11.9 18.0 28.2 42.6 62.2 81.8 0.79
58.7 2.3125
(2) (2) 29 1.125 Kv 2.02 3.08 4.88 7.08 10.3 15.6 24.4 36.8 53.8 70.8 ---
XT 0.753 0.846 0.702 0.666 0.682 0.656 0.619 0.609 0.559 0.530 ---
Cv 5.51 10.9 17.9 30.2 50.5 82.0 133 200 269 328 0.78
111.1 4.375 51 2 Kv 4.77 9.43 15.5 26.1 43.7 70.9 115 173 233 284 ---
XT 0.705 0.701 0.663 0.646 0.612 0.604 0.606 0.605 0.596 0.604 ---
6
Cv 4.00 7.63 11.1 15.0 23.3 35.0 53.3 79.6 112 144 0.78
73.0 2.875
(2) (2) 38 1.5 Kv 3.46 6.60 9.60 13.0 20.2 30.3 46.1 68.9 96.9 125 ---
XT 0.670 0.698 0.725 0.731 0.637 0.629 0.599 0.597 0.573 0.571 ---
1. At 100% travel.
2. Restricted trim.

27
Product Bulletin
51.1:ED
ED Valve June 2010

Table 24. Fisher EAD, Whisper Trim I Cage

Whisper Trim I - Flow Up Linear


Characteristic
Valve Port Maximum Flow Valve Opening—Percent of Total Travel
Size, Diameter Travel Coeffi-
NPS mm Inches mm Inches cient 10 20 30 40 50 60 70 80 90 100
Cv 2.17 5.30 8.44 11.8 14.7 16.6 19.5 21.5 23.1 24.1
1 33.3 1.3125 19 0.75 Kv 1.88 4.58 7.30 10.2 12.7 14.4 16.9 18.6 20.0 20.8
XT 0.390 0.406 0.424 0.454 0.456 0.490 0.490 0.506 0.526 0.536
Cv 4.98 11.0 19.7 27.9 34.5 40.6 45.7 50.1 53.7 55.9
2 47.6 1.875 19 0.75 Kv 4.31 9.52 17.0 24.1 29.8 35.1 39.5 43.3 46.5 48.4
XT 0.670 0.633 0.403 0.330 0.322 0.327 0.343 0.359 0.372 0.386
Cv 12.4 30.4 48.3 67.6 84.2 95.2 112 123 132 138
3 73.0 2.875 38 1.5 Kv 10.7 26.3 41.8 58.5 72.8 82.3 96.9 106 114 119
XT 0.307 0.303 0.330 0.329 0.332 0.331 0.361 0.360 0.360 0.375
Cv 16.7 42.9 67.5 91.2 113 133 152 168 182 194
4 87.3 3.4375 38 1.5 Kv 14.4 37.1 58.4 78.9 97.7 115 131 145 157 168
XT 0.738 0.411 0.378 0.331 0.323 0.342 0.354 0.370 0.391 0.400
Cv 28.8 70.4 112 157 195 220 260 285 310 320
6 111.1 4.375 51 2 Kv 24.9 60.9 96.9 136 169 190 225 247 268 277
XT 0.303 0.331 0.361 0.330 0.330 0.360 0.360 0.390 0.391 0.403

28
Product Bulletin
51.1:ED
June 2010 ED Valve

Table 25. Fisher ED, CL125-600, Quick Opening Cage


Quick Opening
Quick Opening Characteristic
Port Maximum Flow Coeffs for
Valve Valve Opening—Percent of Total Travel
Size, Diameter Travel(1) Coeffi-
6 mm
FL(3)
(0.25 Inch)
NPS mm Inches mm Inches cient 10 20 30 40 50 60 70 80 90 100
Travel(2)
Cv 14.7 4.86 9.39 13.4 16.9 18.9 20.3 21.1 21.8 21.9 22.1 0.81
1 33.3 1.3125 19 0.75 Kv 12.7 4.20 8.12 11.6 14.6 16.3 17.6 18.3 18.9 18.9 19.1 ---
XT 0.703 0.556 0.744 0.724 0.666 0.626 0.584 0.566 0.549 0.554 0.556 ---
Cv 22.6 7.79 14.4 20.5 26.8 32.0 36.6 39.4 41.3 42.7 44.0 0.79
Kv 19.5 6.74 12.5 17.7 23.2 27.7 31.7 34.1 35.7 36.9 38.1 ---
47.6 1.875 19 0.75
XT 0.679 0.494 0.641 0.682 0.680 0.686 0.661 0.649 0.638 0.616 0.597 ---
1-1/2 Fd --- 0.22 0.28 0.32 0.34 0.35 0.36 0.36 0.36 0.36 0.36 ---
Cv 16.2 5.05 9.99 14.7 20.0 24.0 25.7 26.2 27.4 28.6 29.9 0.88
33.3 1.3125
(4) (4) 19 0.75 Kv 14.0 4.37 8.64 12.7 17.3 20.8 22.2 22.7 23.7 24.7 25.9 ---
XT 0.942 0.803 0.904 0.946 0.872 0.838 0.849 0.874 0.832 0.795 0.756 ---
Cv 29.7 13.4 26.8 39.9 51.3 62.9 70.6 73.7 75.6 76.8 77.6 0.77
Kv 25.7 11.6 23.2 34.5 44.4 54.4 61.1 63.8 65.4 66.4 67.1 ---
58.7 2.3125 29 1.125
XT 0.773 0.605 0.695 0.737 0.761 0.703 0.658 0.641 0.635 0.626 0.623 ---
2 Fd --- 0.24 0.30 0.33 0.35 0.36 0.36 0.36 0.36 0.36 0.36 ---
Cv 16.7 4.80 9.58 14.9 20.2 25.7 29.3 31.2 31.2 31.2 31.2 0.87
33.3 1.3125
(4) (4) 19 0.75 Kv 14.4 4.15 8.29 12.9 17.5 22.2 25.3 27.0 27.0 27.0 27.0 ---
XT 0.705 0.578 0.733 0.695 0.698 0.666 0.689 0.735 0.791 0.805 0.805 ---
Cv 33.4 20.9 39.6 58.8 74.2 84.9 97.0 103 106 108 109 0.81
Kv 28.9 18.1 34.3 50.9 64.2 73.4 83.9 89.1 91.7 93.4 94.3 ---
73.0 2.875 38 1.5
XT 0.635 0.601 0.684 0.738 0.767 0.744 0.689 0.669 0.658 0.660 0.652 ---
2-1/2 Fd --- 0.25 0.31 0.34 0.35 0.36 0.36 0.36 0.36 0.36 0.35 ---
Cv 25.3 7.83 15.2 22.8 31.0 40.0 48.3 54.9 60.3 66.4 71.2 0.86
47.6 1.875
(4) (4) 19 0.75 Kv 21.9 6.77 13.1 19.7 26.8 34.6 41.8 47.5 52.2 57.4 61.6 ---
XT 0.642 0.498 0.618 0.627 0.636 0.640 0.669 0.725 0.758 0.737 0.710 ---
Cv 43.6 27.2 52.2 77.9 99.5 124 140 149 154 158 161 0.77
Kv 37.7 23.5 45.2 67.4 86.1 107 121 129 133 137 139 ---
87.3 3.4375 38 1.5
XT 0.635 0.626 0.671 0.745 0.796 0.703 0.657 0.619 0.602 0.591 0.577 ---
3 Fd --- 0.22 0.29 0.32 0.34 0.35 0.36 0.36 0.36 0.36 0.36 ---
Cv 35.2 15.9 31.7 47.2 60.7 74.4 83.6 87.3 89.5 91.0 91.9 0.86
58.7 2.3125
(4) (4) 29 1.125 Kv 30.4 13.8 27.4 40.8 52.5 64.4 72.3 75.5 77.4 78.7 79.5 ---
XT 0.852 0.718 0.837 0.889 0.905 0.842 0.784 0.763 0.760 0.744 0.744 ---
-continued-

29
Product Bulletin
51.1:ED
ED Valve June 2010

Table 25. Fisher ED, CL125-600, Quick Opening Cage (continued)


Port Maximum Coeffs
Valve Flow for 6 mm Valve Opening—Percent of Total Travel
Diameter Travel(1)
Size, Coeffi- (0.25 FL(3)
NPS cient Inch)
mm Inches mm Inches 10 20 30 40 50 60 70 80 90 100
Travel(2)
Cv 45.9 37.7 75.0 125 163 193 220 238 247 251 251 0.79
Kv 39.7 32.6 64.9 108 141 167 190 206 214 217 217 ---
111.1 4.375 51 2
XT 0.607 0.623 0.689 0.733 0.764 0.762 0.723 0.689 0.669 0.683 0.694 ---
4 Fd --- 0.22 0.27 0.29 0.31 0.31 0.31 0.31 0.31 0.31 0.30 ---
Cv 39.8 25.0 47.2 70.1 88.5 101 116 123 127 129 130 0.89
73.0 2.875
(4) (4) 38 1.5 Kv 34.4 21.6 40.8 60.6 76.6 87.4 100 106 110 112 112 ---
XT 0.841 0.707 0.879 0.948 0.989 0.956 0.875 0.851 0.834 0.840 0.834 ---
Cv 92.0 73.6 150 232 306 353 389 416 441 451 460 0.82
Kv 79.6 63.7 130 201 265 305 336 360 381 390 398 ---
177.8 7 51 2
XT 0.660 0.664 0.651 0.667 0.694 0.722 0.742 0.728 0.723 0.719 0.710 ---
6 Fd --- 0.17 0.22 0.25 0.26 0.27 0.28 0.28 0.28 0.28 0.28 ---
Cv 64.9 52.3 101 150 199 247 284 310 329 345 358 0.87
111.1 4.375
(4) (4) 51 2 Kv 56.1 45.2 87.4 130 172 214 246 268 285 298 310 ---
XT 0.758 0.774 0.763 0.771 0.778 0.763 0.761 0.717 0.699 0.707 0.691 ---
Cv 108 80.3 188 290 389 480 554 615 658 705 744 0.87
8 203.2 8 51 2 Kv 93.4 69.5 163 251 336 415 479 532 569 610 644 ---
XT 0.653 0.670 0.628 0.679 0.731 0.766 0.806 0.829 0.859 0.863 0.866 ---
Cv 108 135 291 434 551 639 706 759 807 841 863 0.85
Kv 93.4 117 252 375 477 553 611 657 698 727 746 ---
8 203.2 8 76 3
XT 0.653 0.643 0.699 0.757 0.807 0.838 0.861 0.857 0.841 0.838 0.827 ---
Fd --- 0.19 0.24 0.26 0.27 0.28 0.28 0.28 0.28 0.28 0.27 ---
1. When using 655-ED or 655-ET as a control valve for on-off service, the maximum travel for sizing purposes is 19 mm (0.75-inch).
2. When using self-operated regulators, use coefficients listed for 6 mm (0.25-inch) travel.
3. At 100% travel.
4. Restricted trim.

Notes: The coefficients shown on this page are also appropriate


for EDR.

30
Product Bulletin
51.1:ED
June 2010 ED Valve

Table 26. Fisher ED, CL125-600, Linear Cage


Linear
Linear Characteristic
Valve Port Maximum Flow Valve Opening—Percent of Total Travel
Size, Diameter Travel(2) Coeffi- FL(1)
NPS mm Inches mm Inches cient 10 20 30 40 50 60 70 80 90 100
Cv 3.21 5.50 8.18 10.9 13.2 15.0 16.9 18.6 19.9 20.6 0.84
1 33.3 1.3125 19 0.75 Kv 2.78 4.76 7.08 9.43 11.4 13.0 14.6 16.1 17.2 17.8 ---
XT 0.340 0.644 0.494 0.509 0.532 0.580 0.610 0.629 0.628 0.636 ---
Cv 4.23 7.84 11.8 15.8 20.4 25.3 30.3 34.7 37.2 39.2 0.82
Kv 3.66 6.78 10.2 13.7 17.6 21.9 26.2 30.0 32.2 33.9 ---
47.6 1.875 19 0.75
XT 0.656 0.709 0.758 0.799 0.738 0.729 0.708 0.686 0.683 0.656 ---
1-1/2 Fd 0.30 0.37 0.41 0.44 0.44 0.41 0.38 0.35 0.34 0.34 ---
Cv 2.92 5.70 9.05 12.5 15.6 18.5 21.1 23.9 26.8 29.2 0.91
33.3 1.3125
(3) (3) 19 0.75 Kv 2.53 4.93 7.83 10.8 13.5 16.0 18.3 20.7 23.2 25.3 ---
XT 0.690 0.651 0.633 0.634 0.650 0.666 0.708 0.718 0.737 0.733 ---
Cv 7.87 16.0 24.9 33.4 42.1 51.8 62.0 68.1 70.6 72.9 0.77
Kv 6.81 13.8 21.5 28.9 36.4 44.8 53.6 58.9 61.1 63.1 ---
58.7 2.3125 29 1.125
XT 0.641 0.720 0.728 0.767 0.793 0.754 0.683 0.658 0.652 0.638 ---
2 Fd 0.30 0.35 0.36 0.37 0.37 0.36 0.35 0.35 0.34 0.33 ---
Cv 3.53 6.36 9.92 13.3 16.5 19.7 22.7 25.6 29.3 33.3 0.87
33.3 1.3125
(3) (3) 19 0.75 Kv 3.05 5.50 8.58 11.5 14.3 17.0 19.6 22.1 25.3 28.8 ---
XT 0.456 0.529 0.549 0.582 0.611 0.633 0.671 0.723 0.727 0.694 ---
Cv 9.34 21.6 35.5 49.5 62.7 74.1 83.6 93.5 102 108 0.81
Kv 8.08 18.7 30.7 42.8 54.2 64.1 72.3 80.9 88.2 93.4 ---
73.0 2.875 38 1.5
XT 0.680 0.660 0.644 0.669 0.674 0.706 0.716 0.687 0.658 0.641 ---
2-1/2 Fd 0.27 0.33 0.35 0.36 0.35 0.34 0.32 0.29 0.27 0.27 ---
Cv 4.10 8.09 12.3 16.7 21.1 26.8 33.7 41.3 49.2 57.0 0.84
47.6 1.875
(3) (3) 19 0.75 Kv 3.55 7.00 10.6 14.4 18.3 23.2 29.2 35.7 42.6 49.3 ---
XT 0.668 0.646 0.684 0.688 0.698 0.694 0.678 0.668 0.669 0.666 ---
Cv 14.5 32.9 52.1 70.4 88.5 105 118 133 142 148 0.82
Kv 12.5 28.5 45.1 60.9 76.6 90.8 102 115 123 128 ---
87.3 3.4375 38 1.5
XT 0.671 0.699 0.697 0.720 0.733 0.718 0.707 0.650 0.630 0.620 ---
3 Fd 0.26 0.32 0.35 0.36 0.36 0.36 0.36 0.28 0.29 0.30 ---
Cv 8.06 16.9 26.7 37.5 49.0 61.4 73.8 85.3 94.7 102 0.85
58.7 2.3125
(3) (3) 29 1.125 Kv 6.97 14.6 23.1 32.4 42.4 53.1 63.8 73.8 81.9 88.2 ---
XT 0.592 0.614 0.662 0.672 0.674 0.676 0.694 0.722 0.736 0.732 ---
Cv 23.3 50.3 78.1 105 127 152 181 203 223 236 0.82
Kv 20.2 43.5 67.6 90.8 110 131 157 176 193 204 ---
111.1 4.375 51 2
XT 0.691 0.714 0.720 0.731 0.764 0.757 0.748 0.762 0.732 0.688 ---
4 Fd 0.31 0.36 0.38 0.38 0.37 0.35 0.32 0.30 0.27 0.28 ---
Cv 9.77 22.6 37.2 51.8 65.7 77.5 87.5 97.9 107 113 0.84
73.0 2.875
(3) (3) 38 1.5 Kv 8.45 19.5 32.2 44.8 56.8 67.0 75.7 84.7 92.6 97.7 ---
XT 0.926 0.899 0.873 0.904 0.919 0.962 0.972 0.937 0.891 0.872 ---
-continued-

31
Product Bulletin
51.1:ED
ED Valve June 2010

Table 26. Fisher ED, CL125-600, Linear Cage (continued)


Valve Port Maximum Flow Valve Opening—Percent of Total Travel
Size, Diameter Travel(2) Coeffi- FL(1)
NPS mm Inches mm Inches cient 10 20 30 40 50 60 70 80 90 100
Cv 46.3 107 171 228 279 327 367 402 420 433 0.84
Kv 40.0 92.6 148 197 241 283 317 348 363 375 ---
177.8 7 51 2
XT 0.656 0.727 0.744 0.781 0.803 0.800 0.784 0.758 0.755 0.740 ---
6 Fd 0.21 0.26 0.29 0.30 0.31 0.31 0.31 0.28 0.28 0.28 ---
Cv 16.7 38.6 65.4 93.7 123 156 194 244 290 322 0.88
111.1 4.375
(3) (3) 51 2 Kv 14.4 33.4 56.6 81.1 106 135 168 211 251 279 ---
XT 0.762 0.698 0.675 0.684 0.681 0.660 0.676 0.657 0.685 0.703 ---
Cv 60.2 129 206 285 363 444 526 581 640 688 0.87
8(2) 203.2 8 51 2 Kv 52.1 112 178 247 314 384 455 503 554 595 ---
XT 0.704 0.721 0.657 0.651 0.683 0.713 0.740 0.801 0.821 0.839 ---
Cv 91.4 207 325 440 550 639 711 760 795 846 0.87
Kv 79.1 179 281 381 476 553 615 657 688 732 ---
8 203.2 8 76 3
XT 0.651 0.624 0.677 0.746 0.786 0.803 0.823 0.836 0.843 0.807 ---
Fd 0.23 0.28 0.30 0.31 0.31 0.31 0.31 0.31 0.31 0.31 ---
1. At 100% travel.
2. If coefficients listed above for the 8-inch linear cage with 51 mm (2-inch) travel are not sufficient for your application, consider using the quick opening cage. The 8-inch quick opening
cage with 51 mm (2-inch) travel has approximately a linear characteristic.
3. Restricted trim.

Notes: The coefficients shown on this page are also appropriate


for EDR.

32
Product Bulletin
51.1:ED
June 2010 ED Valve

Table 27. Fisher ED, CL125-600, Equal Percentage Cage, Flow Down
Equal Percentage
Equal Percentage Characteristic
Valve Port Maximum Flow Valve Opening—Percent of Total Travel
Size, Diameter Travel Coeffi- FL(1)
NPS mm Inches mm Inches cient 10 20 30 40 50 60 70 80 90 100
Cv 0.783 1.54 2.20 2.89 4.21 5.76 7.83 10.9 14.1 17.2 0.88
1 33.3 1.3125 19 0.75 Kv 0.677 1.33 1.90 2.50 3.64 4.98 6.77 9.43 12.2 14.9 ---
XT 0.766 0.614 0.587 0.667 0.672 0.687 0.743 0.760 0.733 0.667 ---
Cv 1.52 2.63 3.87 5.41 7.45 11.2 17.4 24.5 30.8 35.8 0.84
Kv 1.31 2.27 3.35 4.68 6.44 9.69 15.1 21.2 26.6 31.0 ---
47.6 1.875 19 0.75
XT 0.780 0.735 0.716 0.715 0.738 0.727 0.690 0.685 0.685 0.679 ---
1-1/2 Fd 0.64 0.63 0.63 0.64 0.46 0.45 0.30 0.31 0.35 0.38 ---
Cv 1.12 1.56 2.22 3.10 4.27 6.17 9.01 13.1 18.2 23.1 0.91
33.3 1.3125
(2) (2) 19 0.75 Kv 0.969 1.35 1.92 2.68 3.69 5.34 7.79 11.3 15.7 20.0 ---
XT 0.821 0.864 0.820 0.703 0.721 0.679 0.665 0.639 0.650 0.700 ---
Cv 1.66 2.93 4.66 6.98 10.8 16.5 25.4 37.3 50.7 59.7 0.85
Kv 1.44 2.53 4.03 6.04 9.34 14.3 22.0 32.3 43.9 51.6 ---
58.7 2.3125 29 1.125
XT 0.827 0.834 0.774 0.727 0.687 0.684 0.702 0.736 0.686 0.687 ---
2 Fd 0.41 0.50 0.53 0.58 0.37 0.32 0.27 0.26 0.29 0.31 ---
Cv 0.923 1.42 2.09 2.84 4.11 5.83 8.58 12.8 18.5 24.3 0.88
33.3 1.3125
(2) (2) 19 0.75 Kv 0.798 1.23 1.81 2.46 3.56 5.04 7.42 11.1 16.0 21.0 ---
XT 0.775 0.744 0.742 0.707 0.715 0.714 0.714 0.641 0.621 0.649 ---
Cv 3.43 7.13 10.8 15.1 22.4 33.7 49.2 71.1 89.5 99.4 0.84
Kv 2.97 6.17 9.34 13.1 19.4 29.2 42.6 61.5 77.4 86.0 ---
73.0 2.875 38 1.5
XT 0.778 0.702 0.678 0.677 0.658 0.654 0.661 0.665 0.661 0.660 ---
2-1/2 Fd 0.45 0.49 0.49 0.47 0.35 0.32 0.30 0.24 0.25 0.27 ---
Cv 1.57 2.57 3.82 5.44 7.64 11.5 18.2 26.7 35.1 43.9 0.89
47.6 1.875
(2) (2) 19 0.75 Kv 1.36 2.22 3.30 4.71 6.61 9.95 15.7 23.1 30.4 38.0 ---
XT 0.801 0.756 0.713 0.677 0.648 0.672 0.628 0.635 0.706 0.710 ---
Cv 4.32 7.53 10.9 17.1 27.2 43.5 66.0 97.0 120 136 0.82
Kv 3.74 6.51 9.43 14.8 23.5 37.6 57.1 83.9 104 118 ---
87.3 3.4375 38 1.5
XT 0.774 0.706 0.682 0.635 0.616 0.602 0.663 0.693 0.670 0.675 ---
3 Fd 0.52 0.63 0.68 0.39 0.36 0.29 0.26 0.28 0.30 0.32 ---
Cv 1.75 3.11 4.77 7.07 10.7 17.0 27.9 41.5 58.0 70.7 0.87
58.7 2.3125
(2) (2) 29 1.125 Kv 1.51 2.69 4.13 6.12 9.26 14.7 24.1 35.9 50.2 61.2 ---
XT 0.944 0.840 0.803 0.757 0.735 0.642 0.531 0.613 0.629 0.702 ---
Cv 5.85 11.6 18.3 30.2 49.7 79.7 125 171 205 224 0.82
Kv 5.06 10.0 15.8 26.1 43.0 68.9 108 148 177 194 ---
111.1 4.375 51 2
XT 0.731 0.650 0.643 0.645 0.632 0.625 0.672 0.742 0.737 0.716 ---
4 Fd 0.45 0.42 0.40 0.33 0.30 0.28 0.23 0.24 0.26 0.28 ---
Cv 3.82 7.65 11.4 16.9 25.5 38.2 60.5 85.7 105 112 0.89
73.0 2.875
(2) (2) 38 1.5 Kv 3.30 6.62 9.86 14.6 22.1 33.0 52.3 74.1 90.8 96.9 ---
XT 0.746 0.700 0.694 0.669 0.640 0.627 0.591 0.644 0.735 0.813 ---
-continued-

33
Product Bulletin
51.1:ED
ED Valve June 2010

Table 27. Fisher ED, CL125-600, Equal Percentage Cage, Flow Down (continued)
Valve Port Maximum Flow Valve Opening—Percent of Total Travel
Size, Diameter Travel Coeffi- FL(1)
NPS mm Inches mm Inches cient 10 20 30 40 50 60 70 80 90 100
Cv 12.9 25.8 43.3 67.4 104 162 239 316 368 394 0.85
Kv 11.2 22.3 37.5 58.3 90.0 140 207 273 318 341 ---
177.8 7 51 2
XT 0.688 0.680 0.682 0.709 0.700 0.720 0.736 0.744 0.780 0.778 ---
6 Fd 0.39 0.44 0.47 0.33 0.29 0.22 0.22 0.24 0.25 0.26 ---
Cv 5.40 10.1 15.8 26.7 45.2 71.2 111 169 232 274 0.88
111.1 4.375
(2) (2) 51 2 Kv 4.67 8.74 13.7 23.1 39.1 61.6 96.0 146 201 237 ---
XT 0.834 0.834 0.735 0.654 0.626 0.613 0.614 0.610 0.629 0.695 ---
Cv 18.5 38.0 58.4 86.7 130 189 268 371 476 567 0.85
8 203.2 8 51 2 Kv 16.0 32.9 50.5 75.0 112 163 232 321 412 490 ---
XT 0.727 0.623 0.600 0.588 0.580 0.587 0.599 0.611 0.671 0.724 ---
Cv 27.0 58.1 105 188 307 478 605 695 761 818 0.86
Kv 23.4 50.3 90.8 163 266 413 523 601 658 708 ---
8 203.2 8 76 3
XT 0.644 0.654 0.636 0.611 0.643 0.615 0.725 0.809 0.804 0.807 ---
Fd 0.28 0.26 0.23 0.20 0.17 0.22 0.24 0.25 0.25 0.26 ---
1. At 100% travel.
2. Restricted trim.

Notes: The coefficients shown on this page are also appropriate


for EDR.

34
Product Bulletin
51.1:ED
June 2010 ED Valve

Table 28. Fisher ED, CL125-600, Whisper Trim I Cage, Flow Up


Linear
Whisper Trim I Characteristic
Valve Port Maximum Flow Valve Opening—Percent of Total Travel
Size, Diameter Travel Coeffi-
NPS(1) mm Inches mm Inches cient 10 20 30 40 50 60 70 80 90 100
Cv 3.28 7.39 12.0 14.2 14.9 15.3 15.7 16.0 16.4 16.8
1 33.3 1.3125 19 0.75 Kv 2.84 6.39 10.4 12.3 12.9 13.2 13.6 13.8 14.2 14.5
XT 0.581 0.605 0.617 0.644 0.764 0.790 0.809 0.813 0.795 0.768
Cv 2.62 7.42 13.9 20.8 23.2 24.2 24.9 25.4 26.1 26.7
47.6 1.875 19 0.75 Kv 2.27 6.42 12.0 18.0 20.1 20.9 21.5 22.0 22.6 23.1
XT 0.892 0.766 0.632 0.498 0.614 0.771 0.876 0.919 0.901 0.894
1-1/2
Cv 3.12 7.36 13.0 18.5 20.7 21.4 21.8 23.1 23.9 25.2
33.3 1.3125
(2) (2) 19 0.75 Kv 2.70 6.37 11.2 16.0 17.9 18.5 18.9 20.0 20.7 21.8
XT 0.559 0.605 0.460 0.383 0.472 0.622 0.768 0.823 0.874 0.857
Cv 7.30 19.2 34.6 42.2 45.5 47.0 47.1 47.2 47.2 48.0
58.7 2.3125 29 1.125 Kv 6.31 16.6 29.9 36.5 39.4 40.7 40.7 40.8 40.8 41.5
XT 0.604 0.467 0.318 0.387 0.526 0.689 0.843 0.899 0.940 0.938
2
Cv 2.86 6.79 11.7 18.4 23.6 27.9 30.9 33.5 35.3 36.7
33.3 1.3125
(2) (2) 19 0.75 Kv 2.47 5.87 10.1 15.9 20.4 24.1 26.7 29.0 30.5 31.7
XT 0.672 0.755 0.547 0.386 0.358 0.377 0.398 0.431 0.470 0.483
Cv 12.2 32.6 49.7 54.4 55.9 59.8 64.0 67.7 71.4 74.0
73.0 2.875 38 1.5 Kv 10.6 28.2 43.0 47.1 48.4 51.7 55.4 58.6 61.8 64.0
XT 0.748 0.428 0.414 0.589 0.792 0.877 0.857 0.792 0.712 0.719
2-1/2
Cv 3.11 8.31 14.9 22.4 29.9 36.0 41.6 46.4 50.5 53.6
47.6 1.875
(2) (2) 19 0.75 Kv 2.69 7.19 12.9 19.4 25.9 31.1 36.0 40.1 43.7 46.4
XT 0.603 0.761 0.596 0.467 0.397 0.395 0.398 0.411 0.427 0.439
Cv 16.5 40.3 70.8 88.0 92.1 90.7 90.3 92.6 95.6 99.1
87.3 3.4375 38 1.5 Kv 14.3 34.9 61.2 76.1 79.7 78.5 78.1 80.1 82.7 85.7
XT 0.685 0.471 0.331 0.378 0.532 0.753 0.929 0.983 0.968 0.923
3
Cv 8.15 19.1 33.2 47.6 60.8 72.1 81.8 90.1 97.4 103
58.7 2.3125
(2) (2) 29 1.125 Kv 7.05 16.5 28.7 41.2 52.6 62.4 70.8 77.9 84.3 89.1
XT 0.720 0.660 0.500 0.439 0.406 0.412 0.437 0.472 0.504 0.510
Cv 33.9 76.6 117 135 137 137 141 149 157 169
111.1 4.375 51 2 Kv 29.3 66.3 101 117 119 119 122 129 136 146
XT 0.607 0.385 0.352 0.467 0.682 0.887 0.977 0.958 0.921 0.811
4
Cv 13.6 32.5 54.3 75.5 94.6 112 127 141 153 160
73.0 2.875
(2) (2) 38 1.5 Kv 11.8 28.1 47.0 65.3 81.8 96.9 110 122 132 138
XT 0.674 0.481 0.374 0.344 0.345 0.354 0.370 0.385 0.407 0.428
Cv 55.8 125 196 245 270 286 297 308 323 338
6 177.8 7 51 2 Kv 48.3 108 170 212 234 247 257 266 279 292
XT 0.294 0.323 0.286 0.322 0.406 0.494 0.579 0.644 0.673 0.662
Cv 100 226 337 436 502 581 641 655 659 681
76 3
(3) (3) Kv 86.5 195 292 377 434 503 554 567 570 589
XT 0.456 0.490 0.470 0.427 0.452 0.468 0.521 0.624 0.703 0.701
8 203.2 8
Cv 142 303 428 542 611 652 669 689 700 726
29 4 Kv 123 262 370 469 529 564 579 596 606 628
XT 0.549 0.450 0.436 0.441 0.513 0.624 0.707 0.709 0.729 0.718
1. NPS 6 easy-e valve-body with restricted Whisper Trim not available. Use EW valve body where this trim is desired.
2. Restricted trim.
3. Travel limited to 70 mm (2.75 inches) with Class IV ED valve plug.

Notes: The coefficients shown on this page are also appropriate for EDR.

35
Product Bulletin
51.1:ED
ED Valve June 2010

Table 29. Fisher ED, CL125-600, Whisper Trim III Cage, Flow Up
Linear
Whisper Trim III Characteristic(2)
Valve Port Maximum Flow Valve Opening—Percent of Total Travel
Size, Diameter Travel Coeffi- XT(1)
NPS mm Inches mm Inches cient Minimum(3) 20 30 40 50 60 70 80 90 100
A3 DP/P10.6
Cv 4.67 68.2 92.0 129 163 196 228 257 279 295 0.714
6 136.5 5.375 76 3
Kv 4.04 59.0 79.6 112 141 170 197 222 241 255 ---
B3 DP/P10.75
Cv 4.67 38.2 66.9 94.5 120 144 167 190 211 228 0.473
6 136.5 5.375 76 3
Kv 4.04 33.0 57.9 81.7 104 125 144 164 183 197 ---
C3 DP/P10.85
Cv 4.67 28.0 41.3 55.3 69.3 83.0 97.0 110 124 138 0.563
6 136.5 5.375 76 3
Kv 4.04 24.2 35.7 47.8 59.9 71.8 83.9 95.2 107 119 ---
D3 DP/P10.99
Cv 4.67 6.67 9.50 19.9 31.4 46.0 61.0 75.7 89.7 104 0.563
6 136.5 5.375 76 3
Kv 4.04 5.77 8.22 17.2 27.2 39.8 52.8 65.5 77.6 90.0 ---
1. This column lists XT factors for Whisper Trim III cages at 100% travel.
2. Level D exhibits an equal percentage characteristic for the first 38 mm (1.5 inches) of travel, then linear characteristic.
3. This coefficient is minimum rather than 10% open. Valves should not be required to throttle at less than the specified minimum coefficient for an extended period of time. Erosion
damage to the valve may result.

Notes: The coefficients shown on this page are also appropriate


for EDR.

36
Product Bulletin
51.1:ED
June 2010 ED Valve

Specifications
Available Configurations Maximum Pressure Drop(2)
ED: Single-port, globe-style control valve with Same as maximum inlet pressure for specific
cage guiding, balanced valve plug, and construction defined above, except where further
push-down-to-close valve plug action (figures 1 limited as follows:
and 2) All Valves Except Those with Whisper Trim III
EAD: Angle version of ED control valve, used to and WhisperFlo Cages: See figure 9.
facilitate piping or in applications where a Valves with Whisper Trim III Cages (NPS 6
self-draining valve is desired (figure 3) ED): See figure 11 except where further limited by
EDR: Same as ED control valve except with the following max n-P/P1 ratio(4)—0.60 for level
push-down-to-open valve plug action (figure 4) A3 cage, 0.75 for level B3 cage, 0.85 for level C3
cage, or 0.99 for level D3 cage
Valves for NACE MR0175 / ISO 15156 and
Valve Sizes
MR0103: See figure 13
See table 2
Shutoff Classifications per ANSI/FCI 70-2
and IEC 60534-4
End Connection Styles(1)(2) Class II: Standard with single graphite ring and
Cast Iron Valves. 33 through 203 mm (1.3125 through 8-inch) port
Flanged: ED, NPS 1 through 8, J CL125 flat-face size
or J CL250 raised-face flanges per ASME B16.1 Class III: Optional for valves with single graphite
Steel and Stainless Steel Valves. piston ring and 87 mm (3.4375 inch) or larger port
Flanged: J CL150, 300, or 600 raised-face (RF) diameter
or ring-type joint (RTJ) flanges per Class IV: For valves with multiple graphite piston
ASME B16.5 rings and 111 mm (4.375 inch) or larger port
Screwed or Socket Welding: NPS 1 through 2, diameter
consistent with ASME B16.11 Class V High-Temperature: For valves with port
Buttwelding: NPS 1 through 8 . diameters from 73 through 203.2 mm (2.875
Schedules 40 or 80 consistent with ASME B16.25 through 8-inch) with optional C-seal trim. See
table 1
Socket weld end connection style is not available
for EAD. Construction Materials
Also, see table 2 and figures 14 and 15
Valve Body, Bonnet, and Bonnet Spacer or
Bottom Flange, if used: J Cast iron, J WCC
Maximum Inlet Pressures and Temperatures(1)(2) carbon steel, J 316 stainless steel, J LCC
carbon steel, J WC9 chrome moly steel, or
As listed below, unless limited by maximum J other materials upon request
pressure drop or material temperature capabilities Valve Plug, Cage, and Metal Seating Parts.
Cast Iron Valves. All Valves Except Those with Whisper Trim III and
Flanged: Consistent with CL125B or 250B per WhisperFlo Cages: See table 3.
ASME B16.1 Valves with Whisper Trim III and WhisperFlo
Steel and Stainless Steel Valves. Cages (NPS 4 and 6 ED): See tables 4 and 5.
Flanged: Consistent with CL150, 300, and 600(3) Valves for NACE Specification: See table 10.
per ASME B16.34 Bellows Seal Assembly: J 316L stainless steel
Screwed or Welding: Consistent with CL600(3) per or J N04400
ASME B16.34 All Other Parts: See table 6
- continued -

37
Product Bulletin
51.1:ED
ED Valve June 2010

Specifications (continued)
Material Temperature Capabilities(2) See figure 8 for view of ENVIRO-SEAL bellows
Valve Body/Trim Combinations. seal bonnet. Also, see Bulletin 59.1:070,
All Valves Except Those with Whisper Trim III and ENVIRO-SEAL Bellows Seal Bonnets, for further
WhisperFlo Cages: See table 7. information
Valves with Whisper Trim III Cages (NPS 6 ED):
See table 4. Packing Arrangements
Valves with WhisperFlo Cages (NPS 4 and 6 ED): J Single PTFE V-ring (standard), J double
See table 5. arrangements, J leak-off arrangements,
All Other Parts: See table 6 J ENVIRO-SEAL packing system. See figure 7
for ENVIRO-SEAL configuration.
Flow Characteristics ENVIRO-SEAL Packing Systems in vacuum
Standard Cages: J Quick-opening, J linear, or service: Standard ENVIRO-SEAL packing
J equal percentage systems can be used in vacuum service with
Whisper Trim and WhisperFlo Cages: Linear packing rings in standard orientation. Do not
reverse the ENVIRO-SEAL PTFE packing rings.
See Bulletin 59.1:061, ENVIRO-SEAL Packing
Flow Directions
Systems for Sliding-Stem Valves, for further
ED or EAD: J Standard Cage--Normally down, information.
J Whisper Trim and WhisperFlo Cages—Always
up Approximate Weights
EDR: J Standard Cage--Normally up, J Whisper
NPS 1: 14 kg (30 lb)
Trim Cage—Always down
NPS 1-1/2: 20 kg (45 lb)
NPS 2: 39 kg (85 lb)
Flow Coefficients and Noise Level Prediction NPS 2-1/2: 45 kg (100 lb)
See table 9, the section titled Coefficients in this NPS 3: 57 kg (125 lb)
bulletin, and Catalog 12 NPS 4: 77 kg (170 lb)
NPS 6: 159 kg (350 lb)
Port Diameters and Valve Plug Travels NPS 8: 408 kg (900 lb)
See table 11
Additional Options
Yoke Boss and Stem Diameters J Seal welding of EDR valve body/bonnet joint
for temperatures above 232_C (450_F),
See table 11 J lubricator, J lubricator/isolating valve, J drilled
and tapped connection in extension bonnet for
Typical Bonnet Styles leak-off service, J valve body drain plug, J style
J Plain or J extension. See figures 14 and 15 for 3 fabricated extension bonnet made on order to a
standard dimensions. See table 8 for selection specific length for cryogenic service, J style NS
guidelines. bonnet for seismic service requirements,
J ENVIRO-SEAL bellows seal bonnet. See figure J packings suitable for nuclear service, J C-seal
14 for standard dimensions. trim for Class V high-temperature shutoff
1. EN (or other) ratings and end connections can usually be supplied; consult your Emerson Process Management sales office.
2. The pressure/temperature limits in this bulletin and in any applicable standard limitations should not be exceeded.
3. Certain bonnet bolting material selections may require a CL600 easy-e valve assembly to be derated. Contact your Emerson Process Management sales office for more information.
4. Limitation based on excessive noise increases if max nP/P1 ratio for a given cage level is exceeded.

38
Product Bulletin
51.1:ED
June 2010 ED Valve

ENVIRO-SEAL Packing System Specifications


Applicable Stem Diameters Anti-Extrusion Washer: Filled PTFE
Lantern Ring: S31600 (316 stainless steel)
J 9.5 mm (3/8 inches), J 12.7 (1/2), J 19.1 (3/4),
J 25.4 (1), and J 31.8 (1-1/4) diameter valve
Spring: J 17-7PH stainless steel or J N06600
Packing Box Flange: S31600
stems
Packing Follower: S31600 lined with carbon-filled
PTFE
Maximum Pressure/Temperature Limits(1) Packing Box Studs: Strain-hardened 316 stainless
To Meet the EPA Fugitive Emission Standard steel
of 100 PPM(2) Packing Box Nuts: 316 stainless steel SA194
For ENVIRO-SEAL PTFE and ENVIRO-SEAL Grade 8M
Duplex packing systems: full CL300 up to 232_C Graphite ULF Packing Systems.
(450_F) Packing Ring: Graphite rings
For ENVIRO-SEAL Graphite ULF packing system: Spring: J 17-7PH stainless steel or J N06600
104 bar (1500 psig) at 316_C (600_F) Packing Box Flange: S31600
Packing Follower: S31600 lined with carbon-filled
PTFE
Construction Materials
Packing Box Studs: Strain-hardened 316 stainless
PTFE Packing Systems. steel
Packing Ring and Lower Wiper: PTFE V-ring(3) Packing Box Nuts: 316 stainless steel SA194
Male and Female Adaptor Rings: Carbon-filled Grade 8M
PTFE V-ring
1. Refer to the valve specifications in this bulletin for pressure/temperature limits of valve parts. Do not exceed the pressure/temperature rating of the valve. Do not exceed any applicable code
or standard limitation.
2. The Environmental Protection Agency (EPA) has set a limit of 100 parts per million (ppm) for fugitive emissions from a valve in selected VOC (Volatile Organic Compound) services.
3. In vacuum service, reversing the ENVIRO-SEAL PTFE packing rings is not necessary.

39
Product Bulletin
51.1:ED
ED Valve June 2010

Note
Neither Emerson, Emerson Process
Management, nor any of their affiliated
entities assumes responsibility for the
selection, use, or maintenance of any
product. Responsibility for the
selection, use, and maintenance of any
product remains with the purchaser
and end user.

Fisher, easy-e, Whisper Trim, WhisperFlo, and ENVIRO-SEAL are marks owned by one of the companies in the Emerson Process Management
business division of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of
Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they
are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the
designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their affiliated
entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of
any product remains solely with the purchaser and end user.

Emerson Process Management


Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com

EFisher
40 Controls International LLC 1983, 2010; All Rights Reserved

You might also like