Professional Documents
Culture Documents
Laod Calculation
Laod Calculation
Laod Calculation
earthquake h 13.716
t 0.534542 sec
2512
Siffness (Y -
Floor
direction)
ki/Ki+1 Check,0.7 ki/(Ki+1+Ki+2+Ki+3)/3) Check,0.8
top 4922.541 - -
2nd 137227.441 27.87736 OK -
1st 196776.644 1.433945 OK -
Ground 212870.751 1.081789 OK 1.88421978095046 OK
Basement 1387887.228 6.519859 OK 7.6135550767964 OK
no dia no dia total
2 12 2 12 452.16