Climate & Noise

Control

Intelligent Climate Control

Supply Air Outlet or Exhaust Air Inlet

Control Damper
Climate & Noise Control
KEY CRITERIA

Comfort, Indoor Air


Quality

Individual Control

Balanced Temperature

Optimal Air Diffusion

Low Noise
Pressure Dependent Volume Control
EFFECTS

•Noisy system

•Inefficient Practice

•Imbalance Air V
Distribution

•Uncontrolled Climate

?
Current volumetric flow
is not measured and
dependent on inlet or
system pressure

Intelligent Climate Control


V

?
Pressure Independent Volume Control

D pV D pV

t t

Pressure Air Flow


Airflow Measurement

Rapid Average Pitot tube using log-tchebycheff rule


Airflow Measurement

D lmin . = 6 D

lmin = 2 ⋅ D

4 wh
lmin = 2.
π
VAQ, “The next generation VAV”

Low Leak
Motorised
Honeycomb Control
Mesh for Damper
Uniform Airflow

Wire-free
Climate fast acting
Control actuator

Intelligent Climate Control


Non Linear Calibration
• Since airflow is
non-linear.
100
• Function of duct
cross-sectional
80
area,

Velocity pressure (pa)


construction, and Incorrect
airflow value,
under-root of 60 450 cfm

velocity pressure.
• we follow non 40
linear
exponential Correct
20 airflow value,
calibration 620 cfm

routine and 0
algorithm rather
100
200
300
400
500
600
700
800
900
1000
than linearising
the airflow. Airflow (cfm)

VAQ, “The next generation VAV”


Flexibility in size and airflow

• It comes in site
specific size
requirement, to
match ducting
an additional
transition
piece is not
required.
• It comes in
exact airflow
requirement, to
suit your
requirement.

VAQ, “The next generation VAV”


Sound Attenuation not required
• Since there is no
reduction in area
for airflow
measurement.
• No additional
sound treatment is
required other
than what required
for ducting.
• Due to
architectural
constraints we do
not have enough
space to install
sound attenuator.

VAQ, “The next generation VAV”


Ease in Installation

• No additional
site fabrication
of matching
transition
piece is
required.
• Site fabricated
transition
pieces causes
huge amount
of leakages
and thus our
purpose of
energy saving
is defeated.
VAQ, “The next generation VAV”
Negligible Pressure Drop

• Since there is
no reduction in
area for airflow
measurement.
• We offer
negligible 8pa @ 5m/s

pressure drop
as compared
to any other
pressure
independent 40pa @ 5m/s

volume control
devices.
VAQ, “The next generation VAV”
Ease in Maintenance

• It comes in
standard
depth of 230
mm only, thus
we require less
access
area(trap door)
for
maintenance

less access area required

VAQ, “The next generation VAV”


Zone Regulation Device, Round

For Round
Supply Air
Outlets/Plenum

Wire-free
Zone
Regulation

Intelligent Climate Control


Zone Regulation Device, Rectangular

For Rectangular
Supply Air
Outlets/Plenum
Wire-free Zone
Regulation

Intelligent Climate Control


Room Module, Climate

10 cm
Effective
Individual
Climate Control

Portable cm
JACK-FREE E-Ink Display
4
offers Better
Visibility

Intelligent Climate Control


Wired Communication

•Required additional resources

•Daisy Chain Networking

•Baud Rate limited to 9600 bps, hence add unnecessary delay in communication

•If a single chain breaks, whole network will not work


Wireless Mesh Networks

•multi-hop wireless mesh network protocols

•Baud rate configured to 76800 bps, i.e. 8 times faster


than conventional system

•enable devices to send messages or transfer data to


and from each other

•Self-forming, self-optimizing and self-healing mesh


network
Wireless Mesh Networks
•Consist of thousands of devices or function
nodes and gateways, each node having full
router capability.

•Completely self configuring and self


healing,

•Utilizing LBT(Listen Before Transmit),


CRC(Cyclic Redundancy Check),
acknowledge and re transmission to ensure
packet integrity on data deliveries in each
network hop.

•Automatically routed the fastest and most Gateway


efficient way from the originating node to
the gateway. Router
Power of Mesh Networking
•Faster communication, Better data integrity allow us to provide better
controls with lesser delay for your critical application

24.2

24.025

23.85

23.675

23.5
10/10/2018 16:39:44 10/10/2018 17:02:55 10/10/2018 17:26:55 10/10/2018 18:39:40 10/10/2018 19:53:01

You might also like