INTRODUCTION
This manual describes the body electrical system for the VDL SB200 Pulsar vehicle.
Electrical inputs and outputs referred to in this manual are based on a standard vehicle, and may
change according to customer specifications. Always refer to the customer node, fuse schedules and
drawings which are contract specific..

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 1 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
CONTENTS Page No.

1.) Electrical system………………………………………………………………….. 4-9


Figure 1: Electrical Control Systems Layout
Figure 2: Body Builder Looms Layout
Figure 3: MUX Electrical Panel O/S Cove
Figure 4: MUX Electrical Panel N/S Mid Door Position
Figure 5: MUX Electrical Panel Drivers Overhead
Figure 6: Engine Bay Body Builder Connections
Figure 7: Rear Road Lighting Body Builder Connections
Figure 8: VDL Electrical Panel O/S Cove Front
Figure 9: VDL Electrical Panel O/S Cove Rear
Figure 10: Main VDL Power Distribution Panel O/S Cove Mid Position
2.) Wiring identification………………………………………………………………. 10-11
3.) Signal types……………………………………………………………………….. 12-14
Figure 11: H/S Digital I/P Example
Figure 12: L/S Digital I/P Example
Figure 13: H/S Digital O/P Example
Figure 14: L/S Digital O/P Example
4.) Program logic functions………………………………………………………….. 16-22
Figure 15: Time Chart
Figure 16: Step Sequence
5.) Fault diagnostic…………………………………………………………………… 23-24
Figure 17: Fault Diagnostic Logging In Program
Figure 18: Node Diagnostic Test 25
6.) Kibes runtime software Installation……………………………………………... 25
7.) Kibes runtime online test procedure……………………………………………. 26
8.) Kibes runtime program upload procedure……………………………………... 27
9.) Electrical system reboot procedure…………………………………………….. 28
10.) PC / CPU communications interface plug wiring……………………………..
Figure 19: PC/CPU Communication Interface Lead Wiring
11.) Electrical wiring descriptions and schematics
11.1) Body Power Distribution………………………………………………... 29
11.2) Optional Battery Master Switch………………………………………... 30
11.3) Emergency Switch Wiring………………………………………………. 31
11.4) Battery Protection System ……………………………………………… 32
11.5) CAN J1939 Network…………………………………………………….. 33
11.6) CPU ZRBD & K-Line Diagnostic Wiring………………………………. 34
11.7) CPU Wake Up Board…………………………………………………… 35
11.8) Node Power Supplies…………………………………………………... 36-37
11.9) Engine Hatch Switches…………………………………………………. 38
11.10) Hidden Start Switch……………………………………………………. 39
11.11) Cab Switch Base Layouts…………………………………………….. 40
11.12)-11.18) VDL Road Lighting…………………………………………….. 41-44
11.19) VDL Engine Inspection Lights………………………………………… 45
11.20) Cab Lighting……………………………………………………………. 46
11.21) Entrance Lighting………………………………………………………. 46
11.22) OS Interior Lights………………………………………………………. 47
Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 2 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
Contents (Continued……………………………)
11.23) NS Interior Lights………………………………………………………….. 47
11.24) Entrance Door Wiring…………………………………………………….. 48-49
11.25) Exit Door Wiring…………………………………………………………… 48-49
11.26) Halt Brake Request……………………………………………………….. 50
11.27) Manual Ramp Operation…………………………………………………. 50
11.28) Compak Powered Ramp…………………………………………………. 51
11.29) Kneeling Inhibit……………………………………………………………. 52
11.30) Heavac Heating System (Euro 4)……………………………………….. 53-54
11.31) Drivers Fan………………………………………………………………… 55
11.32) Drivers Heated Seat………………………………………………………. 55
11.33) Heated Front Screen……………………………………………………… 56
11.34) Heated Mirrors…………………………………………………………….. 56
11.35) Manual Destination……………………………………………………….. 57
11.36) Hanover Destination……………………………………………………… 57
11.37) Mobitech Destination……………………………………………………... 58
11.38) Generic CCTV Supplies………………………………………………….. 58
11.39) Bus To Base Radio Supplies…………………………………………….. 59
11.40) PA & Radio Supplies……………………………………………………… 59
11.41) PA & Radio Speaker Wiring……………………………………………... 60
11.42) Ticket Equipment Feeds…………………………………………………. 60
11.43) Washers & Wipers Wiring………………………………………………... 61
11.44) Bus Stopping Wiring……………………………………………………… 61
11.45) Forman Fire Suppression System………………………………………. 62
11.46) Klaxon-Maple Attack Alarm……………………………………………… 62
11.47) Voice-Tech Attack Alarm…………………………………………………. 63
11.48) Multi-Tone Buzzer………………………………………………………… 63
11.49) Emergency Exits………………………………………………………….. 64
11.50) Emergency Hammers…………………………………………………….. 64
11.51) Cyberlyne 1 Camera 1 Monitor System………………………………… 65
11.52) 21st Century Camera System…………………………………………… 65
11.53) Electrical System Layout…………………………………………………. 66
11.54) Electrical Spares Layout…………………………………………………. 67
11.55) Chassis Earth Wiring……………………………………………………... 68
11.56) Looms Layout……………………………………………………………… 69

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 3 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
1. Electrical System
The electrical system on the SB200 body is a multiplex system supplied by siemens V.D.O.
The multiplex control is based on a central processing unit (CPU), linked to three input/output mod-
ules (nodes), by a closed area network (CAN) communications line.
Each node is identified on the CAN communication line by using external links.
Each node sends input information from the vehicle electrical system ie. dash
switches etc to the CPU via the CAN communications link. The CPU processes the
information from the node inputs and via the CAN communication link switches on
the relevant output I.e. Interior light on the specified node.
The CPU processes the node I/O information using a software program written
on KIBES 2 software by Wrightbus personnel. This program is uploaded to the CPU
using a notebook PC via an RS232 communications link. The PC can also be used as a
real-time diagnostic tool by monitoring system functions on line.
The body electrical system is situated at three locations on the vehicle.
The main electrical centre (Fig 3) is behind the first off-side roof cove and contains
the CPU, diagnostic socket, CPU wake up board and multiplex node 2B-1.1. This
node controls the majority of functions located on the off-side of the vehicle. eg.
Interior lights, cab roof equipment, heated mirrors etc.
The second location (Fig 4) is in the door head above the Mid-exit door position on Near side
and contains multiplex node 2B-1.2 and an earth junction box. This multiplex node
controls the majority of functions located on the near side of the vehicle. eg. Door
spotlights, ramp functions, door controls etc.
The third location (Fig 5) is above the drivers overhead panel and contains
multiplex node 2B-2.1 & the main fuse board for body electrics. This multiplex node controls the ma-
jority of functions around the cab, dash and front end areas. I.e. Dash switches, ramp demister etc.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 4 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
Fig 2 – Looms Layout

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 5 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
Wrightbus electrical panel O/S containing multiplex node 2B-2.1, C.P.U, diagnostics socket, and wake
up board.

FIG 3

Earth Block

ZRBD CPU
Wake up board

Comm’s socket

Node 2B-2.1

Wrightbus multi-plex node 2B-1.2 at Mid Door Position.

FIG 4

Earth
Block

Node 2B-1.2

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 6 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
Wrightbus multi-plex node 2B-1.1 at Drivers Overhead.

FIG 5

Main Fuse Panel Node 2B-1.1 Relay Bases

Engine Bay connections BRCB, ELBK

FIG 6

BRCB
ELBK

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 7 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
Rear lights bodybuilder connectors BR01 and BR02 at Off Side Rear.

FIG 7

DAF IOU 1 / IOU 2 / VFC at O/S electrical panel

FIG 8

IOU 2

VFC

IOU 1 ABS

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 8 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
DAF IOU 3 / IOU 4 at O/S Rear electrical panel

FIG 9

IOU 3

IOU 4

Gear Box
Controller

VDL Main Distribution Power Panel O/S.

FIG 10

Main Distribution Panel At O/S Cove Position

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 9 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
2. WIRING IDENTIFICATION
Wrights multiplexed wiring looms are designed using only the three colours de-
tailed below, instead of multi-coloured cables.

Red - Battery Live Positives


Battery Master Positives
Ignition Positives

Black - Negative

White - Input and Output signals to multiplex nodes

There is also different terminology used for signals that are connected to and
from the multiplex nodes, fuse board and ancillary systems. These are detailed
below.

AIN - Analogue input


DIN - Digital input
DOT - Digital output
P+ - Direct Battery Positive Supply
P+30 - Battery Master Positive Supply
P+15 - Ignition Positive Supply

All red and white cables have a printed identifier, along the length of the cable,
with each cable having a specific identifier.

Red Wire
Power Supply P + 001
Identifiers

Positive Battery Live Cable Number

P +30 017

Positive Battery Master Cable Number

P +15 049

Positive Ignition Cable Number

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 10 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
White Wire
Input/Output
Identifiers

DIN 100 DOT 300

DIGITAL INPUT WIRE NUMBER DIGITAL OUTPUT WIRE NUMBER

AIN 200

ANALOGUE INPUT WIRE NUMBER

The wiring identification and colour arrangements described above are for use with the
Wrightbus body electrics only. VDL chassis electrics use a different numbering and
colour system. These can be found within VDL chassis drawings and documentation.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 11 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
3. SIGNAL TYPES
Digital Inputs
A Digital Input can be separated into two types:
1. High Switched (H/S) Digital Input Signal is received from a switch that closes to
+ 24v to activate the signal. The signal is active if the voltage is greater than 66%
of battery voltage, and inactive or dormant if less than this. NB. If a H/S input is
not switched on the pin at the node will float to approximately 12v. (See Fig14)

FIG 11

2. Low Switched (L/S) Digital Input is received from a switch that closes to ground
or battery negative to activate the signal. The signal is active if the voltage is less
than 33% of the battery voltage, and inactive or dormant above this. NB. If a L/S
input is not switched on the pin at the node will float to approximately 12v. (See
Fig15)

FIG 12

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 12 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
Digital Input Configuration.

For program operation it is necessary to assign each input to one of the two types explained
previously i.e. High side or low side.

To designate the input type a three character code is used.

The first character represents the Input logic state when the node receives an input greater
than 66% of Battery voltage i.e. 24 Volts approximately, the second character represents the
logic state when the node Input switch is open and floats to a voltage greater than 33% and
less than 66% of Battery voltage i.e. 12 Volts approximately and the third character represents
the logic state when the node receives an input voltage less than 33% of Battery voltage
i.e. 0 Volts approximately.

For the input type code


1 = Input On
0 = Input Off
E = Input Error

High Side inputs are shown in the table below.

Low Side inputs are shown in the table below.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 13 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
Digital Outputs
A Digital output can be separated into two types:

1. High Switched (H/S) Digital Output signal is active when it transmits a voltage of + 24v and
inactive when it is zero volts. Outputs have different ratings 10amp, 5amp, 3amp & 1amp
maximum loads, outputs can be linked to provide up to
15amps maximum load. (See Fig17)

FIG13

2. Low switched (L/S) Digital Output signal is active when it transmits a voltage of
zero volts and inactive when open circuit. Outputs have a rating of 1amp. (See

FIG 14

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 14 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
PWM outputs for Saloon Heating and Demister Motor Speed control.

PWM outputs operate at a basic frequency of 20 KHz. Via the program the frequency is
chopped to provide a variable speed signal to the motor controller. The frequency is altered
using a word value ranging from 250 - 0, 250 being motor stopped or 0% and 0 being full
speed or 100%.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 15 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
4. PROGRAM LOGIC FUNCTIONS
Various logic functions are used in the multiplex program. A brief description and explanation
of the most commonly used ones are given below.
1. 2 Input AND Gate

Truth Table

The number of inputs required can be extended to any number necessary.

2. 2 Input OR Gate

Truth Table

As with the AND gate number of inputs required can be extended to any number necessary.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 16 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
3. Inverter.

Truth Table

A solid Black Circle may be used on Inputs and Outputs of any module to indicate inversion,
without the need to draw a separate Inverter module.

4. RS Flip Flop
This module can be used in two ways, Set priority and Reset priority. The small square on
the right must be above the centre line for Set to have priority and below the centre line for
Reset to have priority.

Truth Table (Set Priority)

From the truth table for the Set Priority Flip Flop it can be seen that the output is set to 1
when S=1 and this is independent of the Reset State. I.e. X can be either “1” or “0”

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 17 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
From the truth table for the Reset Priority Flip Flop it can be seen that the output is set to 0
when R=1 and this is independent of the Set State.

5. Edge Recognition

Truth Table

If at the input a positive-going edge occurs the output gets true for one cycle.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 18 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
6. Clock Pulse

The Clock Pulse module causes a signal pulse at the output with the state true for time “t1”
and false for time “t2”, according to what is required.

7. Mono-Flop

When a true state occurs at the monoflop input, the module gives out a pulse for a period of
time “t”. If another positive edge occurs at the input when the output is still high then the
time “t” is set again.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 19 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
The Time chart (Fig 15) shows how the Output is held high for a time “t” from the time when
the last positive edge was received.

8. Edge-Delay

The Edge delay transfers the state true on the input to the output with a delay of time “t”.
The state false on the input is transferred to the output without delay.

From the time chart (fig19) it can be seen how the true input state is delayed by a time “t”
whereas the state false has no delay.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 20 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
9. Step sequence
If a sequence of events have to be controlled in a specific logical order a step sequence
facility may be used. Fig 16 shows a typical example of a Flowchart for a step sequence with an op-
tional branch.

The Flowchart for step sequence consists of the following elements.

Step Initialization.

This module is used to initialize the step sequence. At the first cycle this module is automatically acti-
vated and the outputs SO and Activation Output are set true.

Step Module

This module is used in sequence control and serves to activate the actions of a sequence
step. The activation output is set to the state of the signal input (SI). If a positive going edge
occurs at SI then SO is set true.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 21 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
Transition Module

The function of this module is to start the conditions belonging to the respective sequence
step depending on the state of the preceding step module. The result of the relevant transition
conditions is processed and the input is prepared for the next step module via the
output “SO”. If the Signal Input and the Transition Input are true then a pulse is rendered at
the activation output “SO”.
SO

Optional Branch Module

This module allows an optional branch in a sequence of operations. In this type of branching
all the following branches are initialized via the step module before the branching. The
branch where the transition condition is fulfilled first is selected for further program execution.
Hence the transition conditions can be used to initialize a specific sequence of events.

Optional Junction Module

This module must always be used together with the Optional Branch Module. Several
Branches of a sequence control system are joined and the program continues in one branch
after the junction. To activate the step module after the junction the last step of any branch
must have been performed and the transition condition belonging to the step module after
the junction must be fulfilled. The number of branches can be extended up to a maximum of
24.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 22 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
5. DIAGNOSTICS
Online Test Diagnostic - When and online test is carried out using a notebook PC all inputs
and outputs are displayed graphically, showing real time status of the entire electrical system.
In addition to this capability the following functions are also used.

Open Load Diagnostic - The output “smart switches” use a diagnostic current to check for
open load faults on the circuit, eg. fused sidelight lamp, in this case a fault input will be
switched on in the program to register that the output is open circuit. This will be logged by
a counter within the program. The fault input will switch off once the circuit is closed, eg.
lamp replaced. This can be used to register intermittent faults eg. lamp loose in holder
flashing on and off. (See Fig 17 for an example of open load fault logging within the program)

Short Circuit Diagnostic - The output “smart switches” will automatically shut themselves
down if a short circuit is detected, eg. frayed cable comes into contact with chassis, switching
themselves on again when the short circuit is removed. A short circuit fault will also switch
on a corresponding fault input which is registered in the same way as an open load fault. (See Fig 17)

Fig 17

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 23 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
External Node Diagnostic - On each node a 2W test lamp can be connected to plug C pin
10 to check the operational status of the node. The lamp will give a blink code ie. flash,
remain on constantly or not illuminate at all depending on node status. (See Fig 22 for explanation
of external node diagnostic)

Fig 18

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 24 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
6. KIBES RUNTIME SOFTWARE INSTALLATION PROCEDURE
1. Insert disk 1 & left click drive A:
2. Right click on INSTALL program & left click PROPERTIES
3. From INSTALL PROPERTIES window left click PROGRAM tab
4. In CMD LINE: box add ENG to end of command line
ie: command line should be A:\Install.bat ENG
5. Left click ADVANCED button
6. In ADVANCED PROGRAM SETTINGS window ensure that ONLY the PREVENT
MS-DOS-BASED PROGRAMS FROM DETECTING WINDOWS
check box is selected
7. Left click OK button
8. In INSTALL PROPERTIES window left click APPLY & OK
9. In windows explorer select A: drive, double click on INSTALL, after a few seconds a
DOS installation window will appear, follow on screen instructions
10. Set Kibes software to run in DOS ie. in PROPERTIES / PROGRAM / ADVANCED
select MS DOS mode

7. KIBES RUNTIME SOFTWARE ONLINE TEST


1. Select POSTPROCESSORS from the main menu and press ENTER.

2. Select ONLINE TEST from the Postprocessor menu and press ENTER.

3. The system will automatically download the program from the CPU and
enter the Online Test menu.

4. Select SEARCH SHEET NO. and press ENTER.

5. Insert the required sheet number as per the index and press ENTER.

6. Ensure the system is live by selecting RUN and pressing ENTER.

7. Whilst in run mode the user can page forwards and backwards using the F10 and F9
function keys respectively.

8. To EXIT press ESCAPE and select END.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 25 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
8. KIBES RUNTIME PROGRAM UPLOAD PROCEDURE
1. Insert the Program & Online Test Files disk in drive A.

2. Select POSTPROCESSORS from the main menu and press ENTER.

3. Select PROJECT TOOLS from the Postprocessor menu and press


ENTER.

4. Select OLT DATA REST from Postprocessor menu and press ENTER.

5. Ensure source directory is set at A:\ and press ENTER twice.

6. High light required program and press ENTER.

7. Select PLC PROG REST from Postprocessor menu and press enter, then
repeat steps 5 & 6

8. Once files are installed select END and ENTER.

9. Now choose COMMUNICATION from the Postprocessor menu.

10. Select LOAD PLC PROG and press ENTER twice.

11. Highlight required program and press ENTER.

12. System will upload data to the CPU.

13. To EXIT press ESCAPE and END.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 26 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
9. ELECTRICAL SYSTEM REBOOT PROCEDURE

After the Kibes Runtime Program Upload Procedure has been completed it is advisable to
Reboot the Electrical System. This procedure may also be required in the event of a System
Lock up. There are three different methods available that can be used to Reboot the System.
Procedure.

1. Ensure the CPU/PC Communications Interface lead is unplugged from the socket on
the vehicle.

2. Ensure Battery Master Switch is switched off.

3. Remove CPU Batt Live fuse from Fusebox (3A - see fuse schedule) and then replace
ensuring fuse is removed for at least 1 second.

OR

3. Unplug A Plug on the CPU for at least 1 Second


OR

3. Disconnect Positive Battery cable from positive terminal of Battery for at least 1
second. (This option will also reset the chassis Electrical system).

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 27 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
10. PC/CPU COMMUNICATIONS INTERFACE PLUG WIRING

Fig 19 shows the corresponding Pin No for each wire in the Communications Interface Lead

Fig 19

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 28 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11. WIRING DIAGRAMS

THIS SECTION CONTAINS ELECTRICAL SYSTEM WIRING DIAGRAMS,


MULTIPLEX NODE SCHEDULES, FUSE DIAGRAM & ANY ADDITIONAL
CUSTOMER INFORMATION

11.1 Body Power Distribution EWD-05100

The power to the Body Electrical System is supplied from the main VDL distribution board, which is located
above the 2nd O/S roof cove. Within the panel there is two fuse E320 & E406. E406 provides a 50A battery
live feed to the X12 & X34 studs of the main body fuse board above the drivers overhead. E320 provides a
100A battery master feed to the X56 & X78 studs of the main body fuse board. From here all power supplies
are distributed via the body looms of the vehicle.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 29 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.2 Optional Battery Master Switch EWD-05101

The above shows the optional lockable battery master switch which can be fitted onto the side console of
the vehicle to replace the VDL master switch fitted onto the dash. The wiring is simply extended to the side
console from the dash area for connection to the new switch.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 30 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.3 Emergency Switch Wiring EWD-05102

When the emergency switch is activated the vehicle will drop out the battery master supply to the vehicle. The
will also send a L/S 0v signal to pin 9 of the CPU wake up board which prevents the CPU from shutting down.
The Wake Up will also send a L/S 0v signal to Node 2.1/D11, turning on the O/S interior & cab spotlights via
the outputs shown above. To turn on the master switch again the emergency switch will need to be reset.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 31 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.4 Battery Protection System EWD-05103

The battery protection system monitors the battery voltage. When the voltage drops below a predetermined
level, the guard cuts off the battery master solenoid. The battery guard can be reset by pressing the BPS re-
set switch on the drivers overhead, allowing battery master supply to be reconnected. To test the unit hold
the BPS Switch for 3 seconds to simulate the battery voltage dropping to a low value. NB: The BPS will not cut
off the battery master solenoid when the engine is running. The BPS is wired according to the above diagram.
The battery master switch wiring is broken through the BPS relay (mounted at 2nd O/S roof cove). The BPS
switch and warning light are mounted on the drivers overhead (carling switch & britax warning lamp). The

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 32 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.5 Body Electrical CAN J1939 Network EWD-05104

The above diagram shows the Closed Area Network (CAN) system used on the SB200 Body electrical system.
Each of the 3 nodes used has an individual twisted pair connection between their own location and the central
processing unit. The CPU is also linked to the VDL chassis electrics via a twisted pair connection, this is to en-
able the body and chassis to interface various signals between them. These signals are used for such opera-
tions as displaying warning lamps on the VDL dash and also for the VDL system to tell the body multi-plex sys-
tem such signals as gear selected, speed signal etc….. Euro 4 heating systems also have an interface with the
multi-plex system for controlling the water boost pump etc…...

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 33 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.6 CPU ZR2BD & K-Line Diagnostic EWD-05105

The SB200 has 2 communication sockets fitted for interfacing with the Body Multi-plex system. One is mounted
on the main electrical centre above the 2nd O/S cove with the second being mounted on the dash at the drivers
left hand side. Both are powered from the same fuse as shown above. The CPU power supplies are also shown
above with the 2 wake up signals required for CPU to operate being shown on the left hand side. These signals
are 24v high sides received from the CPU wake up board mounted beside the CPU. The wake up board is used
to allow the Multi-plex system to shut down when none of its functions are being used. A full description of the
wake up board is shown on next page.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 34 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.7 CPU Wake Up Board EWD-05106

Above shows the wiring of the CPU wake up board. This is an electronic unit which is used to control the start
up and shutting down of the body multi-plex system. The board is located on the main electrical centre above
the 2nd O/S roof cove. The basic principle of the unit is that when it receives an input it will provide a +24v
supply to pin A2 pr A4 of the ZR2-BD CPU and therefore start it up (wake up) If all the inputs are lost then the
wake up signal will be lost and therefore the CPU will shut down. The unit is capable of taking 8 inputs, 4 of
these are H/S 24v signals and 4 are L/S 0v signals (these are shown on left above). As the signals are also
required by the multi-plex system for program operation when the input is received the wake up board will
also forward the input onto the multi-plex system in the form of a L/S input to a node. When an input is active
to the wake up board a corresponding LED will light up on the board to symbol that the input is active. Not all
of the inputs shown are used on all contracts (check system schedule to check which are being used)

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 35 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.8 Node Power Supplies EWD-05109, EWD-05110, EWD-05111

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 36 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.8 Node Power Supplies (continued……………..)

For the fuse ratings of each individual group supply check system schedule fuse allocation for the specific con-
tract.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 37 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.9 Engine Hatch Switches EWD-05112

The engine hatch switch consists of a roller trip micro-switch mounted on the O/S of the engine bay. When the
engine hatch switch is closed the switch is activated. The SB200 has a plug mounted in the engine bay (BRCB
Plug), with 4 connections, pins 1 & 4 are used to tell the VDL electric system when the rear hatch is open and
prevent starting from the starter switch mounted on the dash. Pins 2 & 3 are used for connection of an addi-
tional emergency stop. This is usually mounted behind the coolant door at the O/S rear of the vehicle. The N/C
side of the hatch switch is used for input to the body multi-plex system for a hatch open signal.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 38 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.10 Hidden Start Switch EWD-05113

The hidden start switch is a optional feature which is used to give an audible and visual warning when the bus
has not been attempted to be started correctly. An additional Britax switch is fitted in the dash area, the wiring
from the VDL starter switch is broken through this. When the switch is not pressed the signal will go to the
multi-plex node as an input and this will cause the horn to sound. If the switch is pressed the VDL starter signal
will travel as normal and cause the vehicle to start if all the appropriate conditions are met.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 39 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.11 Cab Switch Base Layout EWD-05115

Above shows the pin arrangements for all the switch bases located within the drivers over-
head console. Depending on contract specification not all of these will be used. For more
Information check system schedule node allocations.
The switches used are of a 10-pin carling arrangement having both an illumination function
for when sidelights are turned on and also a status illumination for when the actual switch
has been activated.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 40 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.12—11.19 VDL Road Lighting

Road lighting is now controlled solely from the VDL chassis functions. At both the rear and
front of the vehicle VDL has supplied body builder connections to which wrightbus has
attached looms to supply the various feeds to the light positions at front and rear exterior of
the vehicle.

The wiring schematics contained in the following pages show the location of where each
light is fed from on the VDL electrical system. Not shown is the inputs etc…. Obtained from
the road lighting switches on the dash. More information on the wiring of the VDL system
can be found within their documentation.

Below shows a basic block diagram of how the road lighting supplies are routed to the
various positions throughout the vehicle:

VDL IOU Unit


(check drawing for location)

VDL Looms

Body Builder Connection


(BBFR, BBFL, BBFT, BR01, BR02)

Body Looms

Road Lighting

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 41 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.12 VDL O/S & N/S Headlights EWD-05116

11.13 VDL O/S & N/S Front Sidelights EWD-05117

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 42 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.14 VDL O/S & N/S Rear Sidelights EWD-05118

11.15 VDL Brake Lights EWD-05119

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 43 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.16 VDL Indicators EWD-05120

11.17 VDL Fog Lights EWD-05121

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 44 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.18 VDL Reverse Light & Bleeper EWD-05122

Above shows the operation of the reverse warning system on the bus. When reverse gear is selected the VDL VFC sends a CAN signal out to
the body multi-plex telling it reverse selected. If ignition is on and the reverse bleeper over-ride not selected the reverse bleeper will be
powered via the output shown above. At same time the VDL electrics will also illuminate the reverse light via the IOU output shown.

This signal is used with master on and ignition on to activate the reverse bleeper to give an audible warning as well as a visual supplied by
the light. To over-ride the reverse bleeper an O/R switch is fitted on the dash. When pressed this will mute the bleeper for a total of 3 min-
utes when it will time out and activate the bleeper again. If the O/R is pressed before the 3 min interval the bleeper will sound again.

11.19 VDL Engine Inspection Lights EWD-05123

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 45 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.20 Cab Lighting EWD-05124

When the battery master switch, interior light master switch and sidelights are on and the front entrance door is not closed the cab spot
light will be illuminated as with the entrance lights via the output. Alternatively if the battery master switch, interior lights master switch and
the cab light switch are on the spotlight can be turned on independently of the sidelights or front entrance door. A dimmer switch can
added in series and mounted on the overhead for dimming of the cab light.

11.21 Entrance Lighting EWD-05125

The 1st NS light & shelf plate lights on the front door will be illuminated when the battery master switch, the ignition, and the sidelights are on
and the front door is not in the closed position. When the front entrance door is closed the lights will extinguish. A tube heater function is wired
on the entrance lights which will allow fast illumination of the light when the door is opened. The mid door shelf plate lights will be illuminated
as for the conditions above, except for the mid exit door being in the not closed position. When the mid exit door is closed the lights will be

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 46 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.22 OS Interior Lighting EWD-05126

The O/S lower deck interior lights will be illuminated when the battery master switch is on, the interior light master switch is on and the O/S
lower deck interior light switch is on. The lights will also illuminate in the event of the VDL emergency switch being activated, or the clean-
ers light switch being activated (dependant on spec)

11.23 NS Interior Lighting EWD-05127

The N/S interior lights will be illuminated when the battery master switch is on, the engine is running, the interior light master switch is on
and the N/S lower deck interior light switch is on. A 24v supply is given through DOT 402 for illuminating the lights.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 47 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.24 Entrance Door EWD-05128 (see next page……………….)

11.25 Exit Door EWD-05129 (see next page…………………)

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 48 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.24 Entrance Door Control (see previous EWD-05128)

The front entrance door is opened and closed by the push buttons on the side console (or optional
open footswitch). The door open push button switches a LS signal to the node input 2B-1.2/D9.
Power is applied to the door open solenoid by the node output 2B-1.2/E6 provided the following are
true

1. Speed < 5Kph (VDL CAN signal).


2. Battery master switch is on.

Once the front door is opened the reed switch in the door head switches LS to 2B-2.1/D7 and in turn
activates the door open lamp which is incorporated into the open push button, which is illuminated by
the LS output 2B-1.1/E13.
The door close push-button switches a LS signal to 2B-1.1/D10. Power will be supplied to the door
close solenoid by the node output 2B-1.2/E8 provided that the front door is not in the closed position.

11.25 Mid/Exit Door Control (see previous EWD-05129)

When the Mid exit door open push-button is pressed a LS signal is applied to the node input 2B-1.1/
D11. Power will be applied to the mid door open solenoid by node output 2B-1.2/E2 if the following
conditions are true

1. Speed < 5Kph (VDL CAN signal)


2. Handbrake is on (VDL CAN signal)
3. Battery Master on
4. Exit door override switch Not Activated.

Once the mid exit door is open the reed switch in the door head switches a LS signal to 2B-2.1/D8 via
the CPU wake up board and in turn activates the mid door open warning lamp from the LS output 2B-
1.1/E11. When the mid door is opened the door brake will be activated.
When the Mid exit door close push-button is pressed a LS signal is applied to the node input 2B-1.1/
D12. Power will be applied to the mid door close solenoid by node output 2B-1.2/E4 provided the fol-
lowing are true.

1. The Sensitive Edge is not tripped


2. The Battery Master is on.

If the sensitive edge is tripped when the doors are closing the close solenoid will be immediately de-
energised and the door open solenoid will be activated to open the doors.
If the Exit door security over ride switch is activated the doors will immediately start or try to close
regardless of any other input status, i.e sensitive edge, the door brake, door open and close push but-
tons will be over-ridden.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 49 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.26 Halt Brake Request EWD-05130

The halt brake will be activated on the chas-


sis when either the ramp is out or if the mid-
exit door is open (only mid-door vehicles) -
the body MUX will send a CAN message to
the VDL telling it to activate.

11.27 Manual Ramp EWD-05131

The manual ramp proximity sensor is powered by ignition feed through node output DOT 389, 2B-1.1/E16 and provides a signal to 2B-1.1/A17
when the manual ramp is deployed. The ramp out alarm will sound if the ignition is on, the handbrake is on and the ramp is out. The alarm is
powered by a HS from 2B-1.1/B6 and is activated by a negative supply from 2B-1.1/E3. Once the ramp is lifted from stowed position, the door
brake is activated.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 50 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.28 Compak Powered Ramp EWD-05132

This ramp is controlled using a Compak ramp controller and signals from the Wrightbus multiplexing system.
When the battery master switch and ignition are on power is applied to the ramp controller from DOT 409
(Node 2B-1.2/B4 & B6). A ramp authorisation signal is required for the ramp to deploy and this is provided by
output 2B-1.2/E1. The ramp authorisation signal is only provided when the handbrake is on, the exit door is
closed (mid door) or open (front door), the speed is less than 5Kph and Ignition is on. When the ramp out
switch is pressed and held a LS signal is applied to 2B-1.1/A21 and the ramp will deploy. Once the ramp is not
stowed, kneeling is inhibited and the door brake is activated. This will prevent the bus from moving even if the
handbrake is taken off. The ramp in switch will retract the ramp by initiating a LS signal to the input 2B-1.1/
A19. When the ramp is operating a buzzer will sound to indicate operation. When the ramp override switch is
activated the ramp controller power is isolated and the ramp can be manually deployed or retracted in the event
of an emergency.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 51 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.29 Kneeling Inhibit EWD-05133

Kneeling of the bus will only be permitted if the ramp is in the stowed position and the doors are open. If the
ramp is out or the doors are closed the body multi-plex system will send a CAN message telling the VDL to in-
hibit the kneeling.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 52 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.30 Heavac Heating System EWD-05134

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 53 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.30 Heavac Heating System EWD-05134 (continued…………….)

The heating system shown on the previous page details the new Euro 4 system as controlled
by Heavac. On Euro 3 vehicles saloon heating was controlled via the Siemens VDO MUX sys-
tem. On Euro 4 the heating controls and program are all contained within the Aranea
controller which is mounted in the Dash Area.

As can be seen from the wiring schematic the body builder has two interface points with the
system, these are as follows:

1/ Power connection to Heavac loom for providing supply to blowers and water pump
2/ CAN & Wake Up connection to Heavac loom for providing various signals to the Aranea
controller.

(Both these connections are found at top of ‘B’ pillar on O/S of the vehicle)

The demister unit will be standard on all vehicles, this will provide hot or cold air which can
then be independently switched between the front screen and driver. A button can also be
pressed to solely provide a demisting function. This arrangement is the same as Euro 3
Vehicles.

The saloon heating function will come as an option for this heating system. The Aranea con-
troller has two temperature set point controls which the driver can vary to increase or reduce
the saloon temperature. A digital display will show the driver what the saloon set point is.
The Aranea controller will send a PWM signal to the blowers to vary their speed depending
on the desired temperature. If pre-determined by the customer the temperature set point
can be preset by the body builder and the adjustment function disabled to prevent the driver
from varying the temperature set point of the saloon.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 54 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.31 Drivers Fan EWD-05135

11.32 Heated Drivers Seat EWD-05136

Provided the engine is running, the heated seat is activated by pressing the switch on the overhead console. The seat heating runs on a
timer and is activated for ten minutes. If the engine stops running before the ten minutes is up, the seat will immediately deactivate. The
seat receives a supply from 2B-1.1/A20 & A22
Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 55 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.33 Heated Front Screen EWD-05137

When the heated windscreen switch is pressed a signal is sent to the MUX . If the battery master switch and the engine is running, power
will be supplied to the heated windscreen relays from the node outputs 2B-1.1/E14 and provide power to the O/S screen and N/S screen.
The heated windscreen and signal unit are powered up for 10 minutes, and will not activate again unless the windscreen switch is pressed.

11.34 Heated Mirrors EWD-05138

Provided that the engine is running, the heated mirrors can be activated by pressing the momentary heated mirrors switch on the overhead. The
mirror heating runs on a timer, and is activated for ten minutes. If the engine stops running before the ten minutes is up, the heated mirrors will
immediately deactivate. The O/S mirror receives a supply from 2B-2.1/A14 and the N/S mirror receives a supply from 2B-1.2/A16.
Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 56 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.35 Manual Destination EWD-05139

Power is provided to each sign for illumination purposes. The condition where the light can come on is determined by the program. Most
common is to come on with master switch and sidelights. (see customer specification for correct operation)

11.36 Hanover Destination (LED) EWD-05140

The system consists of 3 signs (front, side & rear) each of which supplied with an battery master feed (varies with contract refer to fuse/node
schedule). A controller mounted in the overhead is connected with each sign via 2-core comms cables as shown. Each sign displays what the
controller is set to. The ERIC version controller has two signals (ignition & reverse as shown). When reverse selected a HS to controller is received
from 1.1/E14 which sets the signs to display ‘BUS REVERSING’. When the ignition is on and is turned off with master still on the controller starts a
15 minute power delay, which when timed out turns the signs off. To reset the master is turned off then on.

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 57 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.37 Mobitech Destination EWD-05141

Similar to the Hanover arrangement with signs front side and rear. In this case the signs can be either Smartblind or LED with power being
supplied from MUX as shown and the comms supplied a common connect box as shown above. A controller is mounted on the drivers over-
head and also has the 15 min delay when used with LED signs with the controller having an ignition feed and the signs having a master
feed.

11.38 Generic CCTV Supplies EWD-05142

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 58 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.39 Bus to Base Radio Supplies EWD-05143

11.40 PA & Radio Supplies EWD-05144

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 59 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.41 PA & Radio Speaker Wiring EWD-05145

11.42 Ticket Equipment Feeds EWD-05146

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 60 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.43 Washers & Wipers Control EWD-05147

The Washer & Wiper functions are controlled from the VDL chassis electrics as shown above. Body looms are attached to the body builder
connections supplied to supply the power to the parts.

11.44 Bus Stopping EWD-05148

If Ignition and Battery Master are on and the Exit and Entrance doors are both closed when a bell pus is activated then;
1. The Interior Bus Stopping Signs will illuminate and both saloon stop bells will ring for a 0.5 sec time period.
2. A Saloon Stop dash lamp will illuminate on the VDL dash display (small bell symbol)
3. At each push of a bell press the saloon dash lamp will flash off for a 0.5 sec time period.
The Interior Bus Stopping Signs and saloon stop dash lamp will remain latched on until either the front entrance door or mid exit door are
opened.
If the Wheelchair Bell Press or Mid door external wheel chair ramp call push button is activated the response will be as above except the
Wheel Chair stop dash lamp will be illuminated and the wheel chair cab bell will sound for 2 seconds.
Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 61 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.45 Forman Fire Suppression EWD-05149

Fire system is used to extinguish engine fires and to give audible warnings of engine overheating. The system is supplied with a Battery
Master feed as shown. The engine bay sensors monitor engine bay heat and the system will give a warning to the drivers speaker if over
heat is detected. Other function include pressure detection of bottle, if to low an audible warning will be given through the speaker also. A
fire wire is routed round the engine, when melted the extinguisher will release the foam into the engine bay.

11.46 Klaxon - Maple Attack Alarm EWD-05150

With the battery master switch on, the attack alarm can be activated by operating the switch on the drivers side console. This sets the alarm by
sending a LS signal to 2B-1.1/A15 via the CPU wake up board. The alarm can be reset by putting the switch on the drivers side console back to its
original position, which provides a LS signal to the system. (For push button and foot switch operation the same inputs and outputs are used, only

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 62 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.47 Voice-tech Attack Alarm EWD-05151

The alarm is set active by a LS input to 1.1/A15 via the CPU wake up board, this causes the speech unit to be powered up via DOT 366
giving a +24v supply out of 1.1/A18. At same a trigger signal consisting of a HS (1.1/E17) and LS (1.1/E18) sets the speech alarm active
sounding an audible alarm. To reset the system the attack switch is returned to normal state giving a LS signal via DIN 164 into 1.1/A13,
this cuts power to the speech unit.

11.48 Multi-tone Buzzer EWD-05152

The cab multi-tone sounder allows the emergency buzzer and wheel chair cab bell to be incorporated into a single unit. The unit is fed a HS sup-
ply from 2B-1.1/B6, and the emergency buzzer or wheelchair buzzer are sounded depending on a LS signal from 2B-1.1/E5 or 2B-1.1/E3 respec-
tively. See the relevant drawings for the use of the cab emergency buzzer (emergency hammers, emergency door open) and the wheelchair
buzzer (bus stopping).

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 63 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.49 Emergency Exits EWD-05153

When the Emergency door is opened a LS signal is applied to input 2B-2.1/D3 or if the emergency window is opened a LS signal is applied
to input 2B-2.1/D12. If either of these two emergency exits are opened a VDL door dash lamp will be illuminated via a CAN signal to the
VDL electrics and the emergency buzzer will sound via the low side output 2B-1.1/E3.

11.50 Emergency Hammers EWD-05154

When either of the emergency hammers are activated on O/S or N/S of the vehicle an emergency hammers dash lamp will be illuminated by a
CAN signal sent from the body MUX system to the VDL chassis electrics. The multi-tone buzzer will sound an emergency alarm for the duration of
the hammers being activated.
Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 64 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.51 Cyberlyne 1 Camera 1 Monitor System EWD-05155

11.52 21st Century Camera System EWD-05156

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 65 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.53 Electrical System Layouts EWD-05196

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 66 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.54 Electrical Spares Layout EWD-05197

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 67 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.55 Chassis Earth Wiring Layout EWD-05198

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 68 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005
11.56 Electrical Looms Layout EWD-05199

Customcare is the Customer Service Division of Wright Group,Galgorm, Fenaghy Road, Ballymena BT42 1PY, N. Ireland.
Page 69 Telephone: +44 (0) 28 2566 3005 Fax: +44 (0) 28 2563 0518 Web: www.customcare-eur.com Email: info@customcare-eur.com VDL SB200 Pulsar
©Wright Customcare Ltd - 2005