Professional Documents
Culture Documents
4 Monitoring Io Rev
4 Monitoring Io Rev
Monitoring I/O
1/
GE /
GE Proprietary Information - Privileged and Confidential
Objectives
2/
GE /
GE Proprietary Information - Privileged and Confidential
Overview
Local VS Remote I/O
General Purpose I/O
Turbine Specific I/O
Uploading from Controller
Forcing Logic and Analog signals
I/O Report
Drawings
3/
GE /
GE Proprietary Information - Privileged and Confidential
Remote and Local I/O
Supports 2 main types of
I/O – Local and Remote
4/
GE /
GE Proprietary Information - Privileged and Confidential
General Purpose I/O
Contact Inputs
Contact Outputs
RTD’s
TC’s
Analog Inputs
Analog Outputs
5/
GE /
GE Proprietary Information - Privileged and Confidential
Turbine Specific I/O
Servo
Vibration
Speed inputs
Primary Trip
Backup Trip
6/
GE /
GE Proprietary Information - Privileged and Confidential
Panel Layout Drawing
Location of
boards
01 case
1A1A Location
Type of board
and IOPacks
TBAIHIC
PAIC
7/
GE /
GE Proprietary Information - Privileged and Confidential
I/O Variables Report
Self Documenting Feature
Information allows us to t/s down to the T/B
and Screw.
Open the Component Editor for the MarkVIe
device
View
Reports
I/O Report
Variables Report
8/
GE /
GE Proprietary Information - Privileged and Confidential
I/O Variables Report -2
9/
GE /
GE Proprietary Information - Privileged and Confidential
I/O Variables Report -3
Explain details
Give an example
Exercise to re-enforce learning
10 /
GE /
GE Proprietary Information - Privileged and Confidential
TCP/IP Address for I/O Packs
The base addresses for I/O Packs
are –
R 192.168.1.x - Red
S 192.168.2.x - Black
T 192.168.3.x - Blue
Where X is the Pack number from
the hardware tab of the
configuration editor.
PAIC-21 ‘s T IONet address would
be 192.168.3.21
11 /
GE /
GE Proprietary Information - Privileged and Confidential
Configuring I/O Packs
12 /
GE /
GE Proprietary Information - Privileged and Confidential
Hardware Revisions
May be obtained through Component editor,
hardware tab, or IO Variables Report
13 /
GE /
GE Proprietary Information - Privileged and Confidential
Hardware Revisions -2
14 /
GE /
GE Proprietary Information - Privileged and Confidential
Redundancy Configuration
Controller Redundancy Configuration
15 /
GE /
GE Proprietary Information - Privileged and Confidential
Redundancy Configuration –2
IONet Redundancy
Configuration
16 /
GE /
GE Proprietary Information - Privileged and Confidential
Redundancy Configuration –3
I/O PACK
Redundancy
17 /
GE /
GE Proprietary Information - Privileged and Confidential
UDH Network Configuration
18 /
GE /
GE Proprietary Information - Privileged and Confidential
EGD Information
19 /
GE /
GE Proprietary Information - Privileged and Confidential
Forcing I/O Points
Must be
forced at
hardware
tab
Double
click on
green live
value
20 /
GE /
GE Proprietary Information - Privileged and Confidential
Forcing EGD Points
Select the
EGD Tab
Double Click
on live value
21 /
GE /
GE Proprietary Information - Privileged and Confidential
Viewing Forced Variables
In component editor
View
Forced Variables
Or <Control>+<Shift>+<f>
22 /
GE /
GE Proprietary Information - Privileged and Confidential
Viewing Forced Variables -2
23 /
GE /
GE Proprietary Information - Privileged and Confidential
Uploading from MarkVIe Device
Component Editor
Device
Upload
Follow the wizard’s questions.
Will first backup the device that was open by
creating G1_date as a new device added to the
system.
Then uploads from controller to device G1.
File>Compare Devices shows differences.
24 /
GE /
GE Proprietary Information - Privileged and Confidential
Lab #3
25 /
GE /
GE Proprietary Information - Privileged and Confidential