Report Cross Section TERM. OLHAL 4,3MM JST SRA-21T-4 CB 20AWG

You might also like

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 2

Terminal Crimping Report

TERMINAL OLHAL 4,3X0,5MM 0,3~0,75MM2 SRA-


SUPPLIER DATE 14/09/2023
21T-4
PN
PRODUCER Sample GREE WIRE SPEC 26/0.160 + 0.006 mm
CUSTOMER
SERIAL CB FLEXIVEL 20AWG UL1015
TER P/N SRA-21T-4 02004000200001 WIRE TYPE
NUMBER XYNIA
EQUIPMENT Terminal Analysis Measurement System

Name Standard Result Value


Conduction Height 1.60+0.05mm 1.619mm
Conduction Width 2.70+0.05mm Acceptable 2.71mm
Insulation Height 2.90+0.05mm 2.93mm
Insulation Width 3.30+0.05mm 3.33mm
Test results
Section Reduction Ratio NA NA 25>=x>=5
Compression Ratio NA 75<=x<=95
Cross coun 26
OK 26
Bending angle NA
NA x<=30.00Deg
Tensile test 70N Mín.
OK 142.56N

Appearance discrimination
1.Not honey comb shaped pressing or gap inside Yes [ ] No [ × ]

2.Distance between terminal wall and wings is too short Yes [ ] No [ × ]

3.Distance between terminal bottom and wings is too short Yes [ ] No [ × ]

4.Burr height exceeds material thickness Yes [ ] No [ × ]

5.Burr width exceeds 1/2 of material width Yes [ ] No [ × ]

6.Crimping area to terminal body distorted. Yes [ ] No [ × ]

7.Crimp wing claws not rolled symmetrically Yes [ ] No [ × ]

8.Crimping crack Yes [ ] No [ × ]

9.Crimping is not closed or Of stands width Yes [ ] No [ × ]

10.Single strands outside or single strands squeezes between


Yes [ ] No [ × ]
crimp wings

No items should be found in photo while a crimping is accepted

Remarks

Detection Test date 14/09/2023

Approve: Review by: Made by:


ANNE SANTOS ANNE SANTOS MOISES NOGUEIRA