125
Wet test voltage (1 min.) 460 kV
300
Dry lightning impulse voltage (BIL) 1050 kV
63
Dry switching impulse voltage (SIL) 850 kV
7
Arcing distance 2190 mm
Mimimum creepage distance 8200 mm
Cantilever test load 1 min. 4000 N
Max. angle of mounting from the vertical 90°
2 Maximum operating altitude 1000 m
MAX
150
Capacitor technology: resin impregnated paper
Housing insulator color: GREY RAL 7047
Conductor execution FLEXIBLE DRAW LEAD
arcing=2190mm
B 402
Positions on drawing
368 1 Top terminal
60
2 Housing insulator type: Composite
2146
2653
3 Flange (Al)
TO BE MACHINED
BY CUSTOMER 4 Test tap
2282
5 Eyebolt
6 Air outlet screw
7 Flexible Draw Lead
3887
400
N 12 HOLES
C 23
3
70
207
25
FLANGE HOLES
K=600
D
26
liability and is subject to change without notice. Reproduction, use or disclosure
65
201
depend on the technical and commercial circumstances. It is provided without
EARTHING SYSTEM
that it is complete or correct or will apply to any particular project. This will
4
to third parties, without express written authority, is strictly prohibited.
SCALE 3:20
© GE. All rights reserved. Information contained in this document is
15°
450
400
30°
E 6
15°
5
HD24501215245 RX810605-83 600 3986 310 AIR SIDE TINNED COPPER TERMINAL MIN.AMBIENT AIR TEMP. -25°C
Part Number Variant Number K (mm) L.Tot. (mm) Weight (kg) Notes
Type: PNR.245.1050.1250 Product Code:
B303 - [Bushing] - PNR
General Tolerance: General ISO 2768 - m K - -
Scale: 1:20 Description Created: 02/03/2020 Luca Cucchi
Quality Level: 3 Approved: 02/03/2020 Daniele PIROVANO
Design Authority: RPV Unit: mm TRANSFORMER BUSHING
Local Unit: RPV Format: A4 EC number: RX0002910C Sheet: 1/1
Drawing number Rev.
245 kV 1250 A
RXF00169-59 00
Creo/ProE
Our Quote N° Rev. Page n.
766 2 6/8
Ns. Offerta N° Rev. Pagina n.
Item 1
Pos.
Your Ref. 1
Vs. Rif.
Item 2
Pos.
Your Ref. 2
Vs. Rif.
Application N/A
PNR
Resin Impregnated Paper Bushing Superior Design
72,5 to 420 kV for Increased Efficiency
Compact, robust and reliable dry design.
The design, components and manufacturing technology of RIP bushings add up to an
average lifetime in excess of 30 years under normal operating conditions. Partial discharge-free up to double rated
nominal voltage
Installation Flexibility
Ease of transport, handling, storage and
installation; installation and operation are
possible in any position.
Seismic Solution
RIP bushings offer flexible retrofitting
possibilities without concern for seismic
withstand.
Imagination at work
PNR RIP Bushing 72,5 to 420 kV Application
PNR Components
Construction
1. HV terminal
2. Conductor
3. RIP condenser core
4. Polyurethane filling
5. Composite insulator
6. Test tap
7. Main flange
Name Plate
Each bushing is provided with a name plate containing complete
electrical data and its serial number in accordance with IEC/IEEE
requirements. The aluminium name plate is secured to the flange
with rivets and carries the following information:
2
GEGridSolutions.com
PNR RIP Bushing 72,5 to 420 kV Application
GEGridSolutions.com 3
GE Dry Bushings- Long life, Excellent Reliability
Flange Packing and Transportation
The flange is made of aluminum and equipped with lifting holes After testing and before packing, the bushing is cleared of any
and a power factor tap (tested at 3 kV for 60 s) and/or voltage tap, dust. Dry insulated bushings are easy to transport and handle.
on request. There is no risk of oil or gas leakage during handling.
Top Terminal
1.
The standard bushing top terminal is made of aluminium with no
surface treatment. On request, it can be supplied in tinned or
silvered copper. Draw-lead or draw-rod type bushings (rated
current up to 2,000 A) have a removable top terminal. This
terminal is connected to the copper inner terminal lug or the
draw rod by means of multi-blade contacts and is screwed to the
bushing head. In bottom-connected bushings, the inner non-
removable rod also acts as the top terminal.
2. 3. 4. 5.
1. Measurement electrode
2. Insulating bushing
3. Tap body
4. Gasket
5. Closing and grounding cap
GEGridSolutions.com
For more information please contact
IEC is a registered trademark of Commission Electrotechnique Internationale. IEEE is a registered
GE trademark of the Institute of Electrical Electronics Engineers, Inc.
Grid Solutions
GE and the GE monogram are trademarks of General Electric Company.
Worldwide Contact Center GE reserves the right to make changes to specifications of products described at any time without
notice and without obligation to notify any person of such changes.
Web: www.GEGridSolutions.com/contact
PNR-Brochure-EN-2019-07-Grid-PTR-0307. © Copyright 2019, General Electric Company. All rights
Phone: +44 (0) 1785 250 070 reserved.
Imagination at work